1.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38457487

RESUMEN

AIMS: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS: Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION: Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.


Asunto(s)
Marcapaso Artificial , Realidad Virtual , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Diseño de Equipo , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos
2.
Heart Rhythm ; 21(7): 1047-1056, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38369037

RESUMEN

BACKGROUND: Patients with heart failure and a non-left bundle branch block (non-LBBB) QRS pattern have a limited response to biventricular pacing (BVP). OBJECTIVE: A personalized cardiac resynchronization therapy (CRT) implantation approach guided by real-time electrocardiographic imaging (ECGi) was studied. METHODS: Twenty patients with left ventricular ejection fraction (LVEF) ≤ 35%, QRS duration ≥ 120 ms, and non-LBBB [13 (65%) with right bundle branch block and 7 (35%) with intraventricular conduction delay] were recruited. During CRT implantation, right atrial, right ventricular, coronary sinus, His-bundle, and/or left bundle leads were inserted. The total activation time (TAT) with different pacing combinations were measured in real time during implantation by ECGi. The configuration producing the shortest TAT was chosen. Clinical response was defined as ≥1 New York Heart Association class improvement. Echocardiographic response was defined as left ventricular end-systolic volume reduction ≥ 15% and/or LVEF improvement ≥ 10% at 6 months. RESULTS: After ECGi-guided CRT implantation, LVEF improved from 26% ± 6% to 34% ± 11% (P < .01) and New York Heart Association class improved from 3.0 ± 0.5 to 2.0 ± 0.6 (P < .01). Both clinical and echocardiographic response rates were 70%. The ECGi approach resulted in better acute electrical resynchronization over BVP as measured by TAT reduction (40% vs 14%; P < .01). The percentage of TAT reduction was found to be a strong predictor for echocardiographic response (area under the curve for the receiver operating characteristic curve 0.91; 95% confidence interval 0.78-1.00). A strong positive correlation between percentage TAT reduction and percentage LVEF improvement (Pearson R = 0.70; P = .001) was found. CONCLUSION: ECGi-guided CRT implantation in patients with non-LBBB generates superior acute electrical resynchronization compared with BVP and is associated with favorable clinical and echocardiographic outcomes.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Electrocardiografía , Volumen Sistólico , Humanos , Masculino , Terapia de Resincronización Cardíaca/métodos , Femenino , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Anciano , Volumen Sistólico/fisiología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Persona de Mediana Edad , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología , Ecocardiografía/métodos , Estudios de Seguimiento