Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Korean J Radiol ; 19(5): 832-837, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30174471

RESUMEN

Computed diffusion-weighted MRI is a recently proposed post-processing technique that produces b-value images from diffusion-weighted imaging (DWI), acquired using at least two different b-values. This article presents an argument for computed DWI for prostate cancer by viewing four aspects of DWI: fundamentals, image quality and diagnostic performance, computing procedures, and future uses.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Sensibilidad y Especificidad
2.
Placenta ; 64: 27-33, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29626978

RESUMEN

INTRODUCTION: Placenta previa (PP) is one of the most significant risk factors for adherent placenta (AP). The aim of this study was to evaluate the diagnostic efficacy of a novel scoring system for predicting AP in pregnant women with PP. METHODS: This prospective cohort study enrolled 175 women with PP. The placenta previa with adherent placenta score (PPAP score) is composed of 2 categories: (1) past history of cesarean section (CS), surgical abortion, and/or uterine surgery; and (2) ultrasonography and magnetic resonance imaging findings. Each category is graded as 0, 1, 2, or 4 points, yielding a total score between 0 and 24. When women with PP had PPAP score ≥8, they were considered to be at a high risk for AP and received placement of preoperative internal iliac artery occlusion balloon catheters. If they were found to have AP during CS, they underwent hysterectomy or placenta removal using advanced bipolar with balloon catheter occlusion. The predictive accuracy of PPAP score was evaluated. RESULTS: In total, 23 of the 175 women with PP were diagnosed as having AP, histopathologically or clinically. Twenty-one of 24 women with PPAP score ≥8 had AP, whereas two of 151 women with PPAP score <8 had AP. The scoring system yielded 91.3% sensitivity, 98.0% specificity, 87.5% positive predictive value, and 98.7% negative predictive value for predicting AP in women with PP. DISCUSSION: This prospective study demonstrated that PPAP scoring system may be useful for predicting AP in women with PP.


Asunto(s)
Placenta Previa/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Adulto , Cesárea/efectos adversos , Femenino , Humanos , Imagen por Resonancia Magnética , Complicaciones Posoperatorias/etiología , Embarazo , Estudios Prospectivos , Medición de Riesgo , Ultrasonografía Prenatal , Miomectomía Uterina/efectos adversos , Adulto Joven
3.
Jpn J Radiol ; 35(12): 707-717, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28983811

RESUMEN

PURPOSE: To investigate the impact of three-dimensional (3D) T2-weighted turbo spin-echo imaging (TSE-T2WI) with tissue-specific variable refocusing flip angle (TS-VRFA) on image quality and prostate cancer (PCa) detection and extraprostatic extension (EPE) evaluation compared to 2D TSE-T2WI and conventional 3D TSE-T2WI with volume isotropic TSE acquisition (VISTA). MATERIALS AND METHODS: Image data sets of 40 patients who underwent 3-T MRI before prostatectomy, including multiplane 2D T2WI, 3D T2WI with TS-VRFA and VISTA, and diffusion-weighted images were independently evaluated by two radiologists. The detectability of PCa and EPE of each sequence was assessed using areas by the receiver operating characteristic curve (AUC) analysis. Image quality measures and contrast ratios (CR) between cancerous lesions and non-cancerous regions for each T2WI were also evaluated. RESULTS: Overall image quality of TS-VRFA was better than that of VISTA and equivalent to 2D. The highest CR was obtained with TS-VRFA (P < 0.05). For both readers, no significances were observed in detectability for PCa detection between three sequences (P > 0.05). For both readers, there were no significant differences in AUC for EPE evaluation between three sequences (P > 0.05). CONCLUSION: 3D T2 WI using TS-VRFA could potentially replace multiplane 2D T2 WI for prostate cancer diagnosis with better image quality than VISTA.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Próstata/diagnóstico por imagen , Prostatectomía , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Int J Urol ; 23(7): 550-7, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27184019

RESUMEN

Digital rectal examination, serum prostate-specific antigen screening and transrectal ultrasound-guided biopsy are conventionally used as screening, diagnostic and surveillance tools for prostate cancer. However, they have limited sensitivity and specificity. In recent years, the role of multiparametric magnetic resonance imaging has steadily grown, and is now part of the standard clinical management in many institutions. In multiparametric magnetic resonance imaging, the morphological assessment of T2-weighted imaging is correlated with diffusion-weighted imaging, dynamic contrast-enhanced imaging perfusion and/or magnetic resonance spectroscopic imaging. Multiparametric magnetic resonance imaging is currently regarded as the most sensitive and specific imaging technique for the evaluation of prostate cancer, including detection, staging, localization and aggressiveness evaluation. This article presents an overview of multiparametric magnetic resonance imaging, and discusses the current role of multiparametric magnetic resonance imaging in the different fields of prostate cancer management.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Humanos , Biopsia Guiada por Imagen , Masculino
5.
J Magn Reson Imaging ; 44(3): 573-83, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26898236

RESUMEN

PURPOSE: To evaluate the interobserver variability and diagnostic performance of a developed magnetic resonance imaging (MRI)-based scoring system for invasive placenta previa. MATERIALS AND METHODS: Prenatal MR images of 70 women were retrospectively evaluated, 18 of whom were diagnosed with invasive placenta. The six MR features (dark band on T2 -weighted images, intraplacental abnormal vascularity, placental bulge, heterogeneous placenta, myometrial thinning, and placental protrusion sign) were scored on 5-point Likert scale separately, and the cumulative radiological score (CRS) was defined as the sum of each score. Two more experienced radiologists (readers A and B) and two less experienced residents (readers C and D) calculated the CRS. Interobserver variability was assessed by measuring the intraclass correlation coefficient. Diagnostic performance was evaluated by means of receiver operating characteristic (ROC) analysis. RESULTS: Interobserver variability for CRS was excellent for the more experienced radiologists (0.85), and good for all readers (0.72) and the less experienced residents (0.66). The area under the ROC curve (Az) and accuracy (Acc) for CRS were significantly higher or equivalent to those of other MR features for all readers (Az and Acc for reader A; CRS, 0.92, 91.4%; intraplacental T2 dark band, 0.83, P = 0.009, 81.4%, P = 0.03; intraplacental abnormal vascularity, 0.9, P = 0.3, 90.0%, P = 1.00; placental bulge, 0.81, P = 0.0008, 80.0%, P = 0.02; heterogeneous placenta, 0.85, P = 0.11, 74.3%, P = 0.002; myometrial thinning, 0.84, P = 0.06, 60.0%, P < 0.0001; placental protrusion sign, 0.81, P = 0.01, 81.4%, P = 0.26). CONCLUSION: This developed MRI-based scoring system demonstrated excellent or good interobserver variability, and good diagnostic performance for invasive placenta previa. J. Magn. Reson. Imaging 2016;44:573-583.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Variaciones Dependientes del Observador , Placenta Previa/diagnóstico por imagen , Placenta Previa/patología , Índice de Severidad de la Enfermedad , Adulto , Competencia Clínica , Femenino , Humanos , Aumento de la Imagen/métodos , Embarazo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
PLoS One ; 10(1): e0117411, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25629156

RESUMEN

BACKGROUND AND PURPOSE: To investigate the diagnostic performance of diffusion-weighted imaging (DWI) and contrast-enhanced imaging in combination with T2-weighted imaging (T2WI) for magnetic resonance imaging (MRI) evaluation of intrapelvic recurrence of gynecological malignancies. MATERIALS AND METHODS: Sixty-two patients with suspected intrapelvic recurrence of gynecological malignancies underwent pelvic MRI including T2WI DWI, and contrast-enhanced imaging. Diagnostic performance for detection of local recurrence, pelvic lymph node and bone metastases, and peritoneal lesions was evaluated by consensus reading of two experienced radiologists using a 5-point scoring system, and compared among T2WI with unenhanced T1-weighted imaging (T1WI) (protocol A), a combination of protocol A and DWI (protocol B), and a combination of protocol B and contrast-enhanced imaging (protocol C). Final diagnoses were obtained by histopathological examinations, radiological imaging and clinical follow-up for at least 6 months. Receiver operating characteristic (ROC) analysis and McNemar test were employed for statistical analysis. RESULTS: Locally recurrent disease, lymph node recurrence, peritoneal dissemination and bone metastases were present in 48.4%, 29.0%, 16.1%, and 6.5% of the patients, respectively. The patient-based sensitivity, specificity, accuracy, and area under the ROC curve (AUC) for detection of intrapelvic recurrence were 55.0, 81.8, 64.5% and 0.753 for protocol A, 80.0, 77.3, 79.0% and 0.838 for protocol B, and 80.0, 90.9, 83.9% and 0.862 for protocol C, respectively. The sensitivity, accuracy, and AUC were significantly better for protocols B and C than for protocol A (p<0.001). There was no significant difference between protocols B and C. CONCLUSION: MRI using a combination of DWI and T2WI gives comparatively acceptable results for assessment of intrapelvic recurrence of gynecological malignancies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de los Genitales Femeninos/patología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Recurrencia Local de Neoplasia/patología , Pelvis/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Jpn J Radiol ; 31(4): 286-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23329316

RESUMEN

We present a case of sclerosing Sertoli cell tumor of the testis that was examined preoperatively by magnetic resonance imaging. A 28-year-old male presented to the urology department of our hospital complaining of a painless mass in the right testicle that had been present for the past 2 years. Levels of the tumor markers AFP, hCG, and LDH were all within the standard ranges. T2-weighted MR images showed a well-demarcated lobular hypointensity 15 mm in size in the right testis. Contrast enhancement of this mass after gadolinium administration was homogeneous, with slightly stronger enhancement than the normal testis tissue. Tumor enucleation was performed, and the tumor was diagnosed as a sclerosing Sertoli cell tumor.


Asunto(s)
Imagen por Resonancia Magnética , Tumor de Células de Sertoli/diagnóstico , Neoplasias Testiculares/diagnóstico , Adulto , Humanos , Masculino , Esclerosis , Tumor de Células de Sertoli/patología , Tumor de Células de Sertoli/cirugía , Neoplasias Testiculares/patología , Neoplasias Testiculares/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...