Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(8)2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39194610

RESUMEN

Exercise-induced muscle injury is one of the most common types of sports injuries. Skeletal muscle troponin I (skTnI) serves as an ideal biomarker in assessing such injuries, facilitating timely detection and evaluation. In this study, we develop a fluorescent sandwich lateral flow immunoassay (LFIA) combined with a desktop analyzer for rapid detection of skTnI. Through optimizing the reaction system, the assay achieves a satisfying detection performance, reaching a limit of detection (LOD) of 0.5 ng/mL with a turnaround time of 15 min. The proposed detection platform offers portability, ease of use, and high sensitivity, which facilitates the monitoring of exercise-induced muscle injuries at the point of care. This feature is particularly advantageous for end users, enabling timely detection of sports-related injuries and ultimately enhancing prognosis and sports life.


Asunto(s)
Músculo Esquelético , Sistemas de Atención de Punto , Troponina I , Troponina I/sangre , Humanos , Inmunoensayo , Músculo Esquelético/lesiones , Biomarcadores/sangre , Técnicas Biosensibles , Límite de Detección
2.
Talanta ; 256: 124327, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36758506

RESUMEN

Upconversion nanoparticles (UCNPs)-based fluorescence probes have shown great potential in point-of-care testing (POCT) applications, due to UCNPs' features of high photostability and background-free fluorescence. Ceaseless improvements of UCNPs-probes have been carried out to increase detection sensitivity and to broaden detection range of UCNPs-based POCT. In this paper, we optimized UCNPs-probes by regulating probe density. The optimization was verified by a traditional lateral flow assay (LFA) platform for C-reactive protein (CRP) detection. Further, the optimized UCNPs-LFA integrating with a home-made benchtop fluorescence analyzer holds the capability to achieve high-performance POCT. Finally, nearly a 20 times sensitivity enhancement with a limit of detection of 0.046 ng/mL and a broad detection range of 0.2-300 ng/mL for CRP detection was obtained. Moreover, the optimized UCNPs-LFA was applied to detecting CRP in clinical serum samples and the detection results were consistent with the clinical test, validating its clinical practicability. The proposed optimization method is also expected to optimize other nanoparticles-based bio-probes for wider POCT application.


Asunto(s)
Nanopartículas , Límite de Detección , Colorantes Fluorescentes , Proteína C-Reactiva
3.
RSC Adv ; 10(64): 38847-38860, 2020 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-35518400

RESUMEN

With the development of modern society, we have witnessed a significant increase of people who join in sport exercises, which also brings significantly increasing exercise-induced muscle injuries, resulting in reduction and even cessation of participation in sports and physical activities. Although severely injured muscles can hardly realize full functional restoration, skeletal muscles subjected to minor muscle injuries (e.g., tears, lacerations, and contusions) hold remarkable regeneration capacity to be healed without therapeutic interventions. However, delayed diagnosis or inappropriate prognosis will cause exacerbation of the injuries. Therefore, timely diagnosis and prognosis of muscle injuries is important to the recovery of injured muscles. Here, in this review, we discuss the definition and classification of exercise-induced muscle injuries, and then analyze their underlying mechanism. Subsequently, we provide detailed introductions to both conventional and emerging techniques for evaluation of exercise-induced muscle injuries with focus on emerging portable and wearable devices for point-of-care testing (POCT). Finally, we point out existing challenges and prospects in this field. We envision that an integrated system that combines physiological and biochemical analyses is anticipated to be realized in the future for assessing muscle injuries.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...