Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Br J Ophthalmol ; 98(1): 40-5, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24169657

RESUMEN

AIMS: To determine if 'Defocus Incorporated Soft Contact' (DISC) lens wear slows childhood myopia progression. METHODS: A 2-year double-blind randomised controlled trial was carried out in 221 children aged 8-13 years, with myopia between -1.00 and -5.00 Dioptres (D) and astigmatism ≤1.00 D. Subjects were randomly assigned to the DISC (n=111) or single vision (SV; n=110) contact lens group. DISC lenses incorporated concentric rings, which provided an addition of +2.50 D, alternating with the normal distance correction. Refractive error (cycloplegic autorefraction) and axial length were measured at 6-month intervals. Differences between groups were analysed using unpaired t test. RESULTS: In total, 128 children completed the study, n=65 in the DISC group and n=63 in the SV group. Myopia progressed 25% more slowly for children in the DISC group compared with those in the control group (0.30 D/year; 95% CI -0.71 to -0.47 vs 0.4 D/year; 95% CI -0.93 to -0.65, p=0.031). Likewise, there was less axial elongation for children in the DISC versus SV groups (0.13 mm/year; 95% CI 0.20 to 0.31 vs 0.18 mm/year; 95% CI 0.30 to 0.43, p=0.009). Treatment effect correlated positively with DISC lens wearing time (r=0.342; p=0.005). Indeed, myopia in children who wore the DISC lenses for five or more hours/day progressed 46% (mean difference=-0.382 D, p=0.001; 95% CI -0.59 to -0.17) less than those in the SV group. CONCLUSIONS: The daily wearing of DISC lens significantly slowed myopia progression and axial elongation in Hong Kong schoolchildren. The findings demonstrated that simultaneous clear vision with constant myopic defocus can retard myopia progression.


Asunto(s)
Lentes de Contacto Hidrofílicos , Miopía/prevención & control , Adolescente , Longitud Axial del Ojo/fisiología , Niño , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Hong Kong , Humanos , Masculino , Miopía/fisiopatología , Estudios Prospectivos , Refracción Ocular/fisiología
2.
Ophthalmic Physiol Opt ; 34(1): 89-93, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24325438

RESUMEN

PURPOSE: The aim of the study was to evaluate the level of agreement between the 'Representative Value' (RV) of refraction obtained from the Shin-Nippon NVision-K 5001 instrument with values calculated from individual measurement readings using standard algebraic methods. METHODS: Cycloplegic autorefraction readings for 101 myopic children aged 8-13 years (10.9 ± 1.42 years) were obtained using the Shin-Nippon NVision-K 5001. Ten autorefractor measurements were taken for each eye. The spherical equivalent (SE), sphere (Sph) and cylindrical component (Cyl) power of each eye were calculated, firstly, by averaging the 10 repeated measurements (Mean SE, Mean Sph and Mean Cyl), and secondly, by the vector representation method (Vector SE, Vector Sph and Vector Cyl). These calculated values were then compared with those of RV (RV SE, RV Sph and RV Cyl) provided by the proprietary software of the NVision-K 5001 using one-way analysis of variance (anova). The agreement between the methods was also assessed. RESULTS: The SE of the subjects ranged from -5.37 to -0.62 D (mean ± SD, = -2.89 ± 1.01 D). The Mean SE was in exact agreement with the Vector SE. There were no significant differences between the RV readings and those calculated using non-vectorial or vectorial methods for any of the refractive powers (SE, p = 0.99; Sph, p = 0.93; Cyl, p = 0.24). The (mean ± SD) differences were: RV SE vs Mean SE (and also RV SE vs Vector SE) -0.01 ± 0.06 D; RV Sph vs Mean Sph, -0.01 ± 0.05 D; RV Sph vs Vector Sph, -0.04 ± 0.06 D; RV Cyl vs Mean Cyl, 0.01 ± 0.07 D; RV Cyl vs Vector Cyl, 0.06 ± 0.09 D. Ninety-eight percent of RV reading differed from their non-vectorial or vectorial counterparts by less than 0.25 D. CONCLUSION: The RV values showed good agreement to the results calculated using conventional methods. Although the formula used to calculate RV by the NVision-K 5001 autorefractor is proprietary, our results provide validation for the use of RV measurements in clinical practice and vision science research.


Asunto(s)
Movimientos Oculares/fisiología , Miopía/diagnóstico , Refracción Ocular/fisiología , Selección Visual/instrumentación , Adolescente , Análisis de Varianza , Niño , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...