Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Carbohydr Polym ; 332: 121907, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38431393

RESUMEN

Low-concentration alkali treatments at low temperatures facilitate the crystal transition of cellulose I to II. However, the transition mechanism remains unclear. Hence, in this study, we traced the transition using in situ solid-state 13C CP/MAS NMR, WAXS, and 23Na NMR relaxation measurements. In situ solid-state 13C CP/MAS NMR and WAXS measurements revealed that soaking cellulose in NaOH at low temperatures disrupts the intramolecular hydrogen bonds and lowers the crystallinity of cellulose. The dynamics of Na ions (NaOH) play a crucial role in causing these phenomena. 23Na NMR relaxation measurements indicated that the Na-ion correlation time becomes longer during the crystal transition. This transition requires the penetration of Na ions (NaOH) into the cellulose crystal and a reduction in Na-ion mobility, which occurs at low temperatures or high NaOH concentrations. The interactions between cellulose and NaOH disrupt intramolecular hydrogen bonds, inducing a conformational change in the cellulose molecules into a more stable arrangement. This weakens the hydrophobic interactions of cellulose, and facilitates the penetration of NaOH and water into the crystal, leading to the formation of alkali cellulose. Our findings suggest that a strategy to control NaOH dynamics could lead to the discovery of a novel preparation method for cellulose II.

2.
J Chromatogr A ; 1706: 464272, 2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37595418

RESUMEN

Recently, there has been a growing demand for miniaturized analytical instruments, including portable HPLC systems, that can enable rapid analysis in the field. This study aimed to develop chip-based separation/detection modules with replaceable detection units for constructing compact HPLC systems to minimize the dead volume. This module provides a tubing-free connection between the column and the detection unit. This study also built detection units for conductivity detection and ultraviolet-visible (UV-Vis) detection to cover a wide variety of inorganic and organic compounds. Furthermore, UV- and Vis-light-emitting diodes were employed for the absorbance detection unit. In addition, portable all-in-one HPLC systems and a handy HPLC system were constructed for ion chromatography and reversed-phase chromatography, demonstrating the successful separation and detection of inorganic ions and several organic compounds.


Asunto(s)
Cromatografía de Fase Inversa , Cromatografía Liquida , Cromatografía Líquida de Alta Presión , Conductividad Eléctrica
3.
ACS Omega ; 7(37): 33079-33086, 2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-36157756

RESUMEN

The translation of nanoparticles (NPs) from laboratory to clinical settings is limited, which is not ideal. One of the reasons for this is that we currently have limited ability to precisely regulate various physicochemical parameters of nanoparticles. This has made it difficult to rapidly perform targeted screening of drug preparation conditions. In this study, we attempted to broaden the range of preparation conditions for particle size-modulated poly(lactic-co-glycolic-acid) (PLGA) NP to enhance their applicability for drug delivery systems (DDS). This was done using a variety of organic solvents and a glass-based microfluidic device. Furthermore, we compared the PDMS-based microfluidic device to the glass-based microfluidic device in terms of the possibility of a wider range of preparation conditions, especially the effect of different solvents on the size of the PLGA NPs. PLGA NPs with different sizes (sub-200 nm) were successfully prepared, and three different types of taxanes were employed for encapsulation. The drug-loaded NPs showed size-dependent cytotoxicity in cellular assays, regardless of the taxane drug used.

4.
PLoS One ; 17(8): e0271050, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35925917

RESUMEN

The realization of poly (lactic-co-glycolic acid) nanoparticles (PLGA NPs) from laboratory to clinical applications remains slow, partly because of the lack of precise control of each condition in the preparation process and the rich selectivity of nanoparticles with diverse characteristics. Employing PLGA NPs to establish a large range of size-controlled drug delivery systems and achieve size-selective drug delivery targeting remains a challenge for therapeutic development for different diseases. In this study, we employed a microfluidic device to control the size of PLGA NPs. PLGA, poly (ethylene glycol)-methyl ether block poly (lactic-co-glycolide) (PEG-PLGA), and blend (PLGA + PEG-PLGA) NPs were engineered with defined sizes. Blend NPs exhibit the widest size range (40-114 nm) by simply changing the flow rate conditions without changing the precursor (polymer molecular weight, concentration, and chain segment composition). A model hydrophobic drug, paclitaxel (PTX), was encapsulated in the NPs, and the PTX-loaded NPs maintained a large range of controllable NP sizes. Furthermore, size-controlled NPs were used to investigate the effect of particle size of sub-200 nm NPs on tumor cell growth. The 52 nm NPs showed higher cell growth inhibition than 109 nm NPs. Our method allows the preparation of biodegradable NPs with a large size range without changing polymer precursors as well as the nondemanding fluid conditions. In addition, our model can be applied to elucidate the role of particle sizes of sub-200 nm particles in various biomedical applications, which may help develop suitable drugs for different diseases.


Asunto(s)
Nanopartículas , Neoplasias , Portadores de Fármacos/química , Humanos , Ácido Láctico/química , Microfluídica , Nanopartículas/química , Neoplasias/tratamiento farmacológico , Paclitaxel/uso terapéutico , Tamaño de la Partícula , Polietilenglicoles/química , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico-Ácido Poliglicólico
5.
Lab Chip ; 22(16): 2971-2977, 2022 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-35713150

RESUMEN

This paper is the first report of a non-competitive fluorescence polarization immunoassay (NC-FPIA) using a peptide as a tracer. The NC-FPIA can easily and quickly quantify the target after simply mixing them together. This feature is desirable for point-of-need applications such as clinical diagnostics, infectious disease screening, on-site analysis for food safety, etc. In this study, the NC-FPIA was applied to detect CD9, which is one of the exosome markers. We succeeded in detecting not only CD9 but also CD9 expressing exosomes derived from HeLa cells. This method can be applied to various targets if a tracer for the target can be prepared, and expectations are high for its future uses.


Asunto(s)
Péptidos , Polarización de Fluorescencia , Inmunoensayo de Polarización Fluorescente/métodos , Células HeLa , Humanos , Tetraspanina 29
6.
J Vis Exp ; (181)2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35404350

RESUMEN

The development of functional lipid nanoparticles (LNPs) is one of the major challenges in the field of drug delivery systems (DDS). Recently, LNP-based RNA delivery systems, namely, RNA-loaded LNPs have attracted attention for RNA therapy. In particular, mRNA-loaded LNP vaccines were approved to prevent COVID-19, thereby leading to the paradigm shift toward the development of next-generation nanomedicines. For the LNP-based nanomedicines, the LNP size is a significant factor in controlling the LNP biodistribution and LNP performance. Therefore, a precise LNP size control technique is indispensable for the LNP production process. Here, we report a protocol for size controlled LNP production using a microfluidic device, named iLiNP. siRNA loaded LNPs are also produced using the iLiNP device and evaluated by in vitro experiment. Representative results are shown for the LNP size, including siRNA-loaded LNPs, Z-potential, siRNA encapsulation efficiency, cytotoxicity, and target gene silencing activity.


Asunto(s)
COVID-19 , Nanopartículas , Humanos , Dispositivos Laboratorio en un Chip , Lípidos , Liposomas , ARN Interferente Pequeño/metabolismo , Distribución Tisular
7.
Biosens Bioelectron ; 198: 113832, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-34856516

RESUMEN

This study aimed to develop an electrochemical system for measuring blood ATP and lactate levels in a single format. The ratio of lactate to ATP levels was previously reported to provide an alternative illness severity score. Although severity evaluation is crucial to treat patients with acute disease admitted to intensive care units, no sensors are currently available to simply and rapidly measure ATP and lactate levels using the same detection method. Therefore, we constructed an integrated sensing system for ATP and lactate using enzymatic reactions and two sets of electrodes integrated into a chip connected to a single potentiostat operated by a microcontroller. The enzymatic system involves adenylate kinase, pyruvate kinase, and pyruvate oxidase for ATP, and lactate oxidase for lactate, both of which produce hydrogen peroxide. Multiplex enzyme-based reactions were designed to minimize the corresponding operations significantly without enzyme immobilization onto the electrodes. The system was robust in the presence of potentially interfering blood components, such as ascorbate, pyruvate, ADP, urate, and potassium ions. The ATP and lactate levels in the blood were successfully measured using the new sensor with good recoveries. The analytical results of blood samples obtained using our sensor were in good agreement with those using conventional methods. Integrating electrode-based analysis and a microcontroller-based system saved further operations, enabling the straightforward measurement of ATP and lactate levels within 5 min. The proposed sensor may serve as a useful tool in the management of serious infectious diseases.


Asunto(s)
Técnicas Biosensibles , Ácido Láctico , Adenosina Trifosfato , Electrodos , Humanos , Gravedad del Paciente
8.
Biosens Bioelectron ; 190: 113414, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34130087

RESUMEN

Antibody detection methods for viral infections have received broad attention due to the COVID-19 pandemic. In addition, there remains an ever-increasing need to quantitatively evaluate the immune response to develop vaccines and treatments for COVID-19. Here, we report an analytical method for the rapid and quantitative detection of SARS-CoV-2 antibody in human serum by fluorescence polarization immunoassay (FPIA). A recombinant SARS-CoV-2 receptor binding domain (RBD) protein labeled with HiLyte Fluor 647 (F-RBD) was prepared and used for FPIA. When the anti-RBD antibody in human serum binds to F-RBD, the degree of polarization (P) increases by suppressing the rotational diffusion of F-RBD. The measurement procedure required only mixing a reagent containing F-RBD with serum sample and measuring the P value with a portable fluorescence polarization analyzer after 15 min incubation. We evaluated analytical performance of the developed FPIA system using 30 samples: 20 COVID-19 positive sera and 10 negative sera. The receiver operating characteristic curve drawn with the obtained results showed that this FPIA system had high accuracy for discriminating COVID-19 positive or negative serum (AUC = 0.965). The total measurement time was about 20 min, and the serum volume required for measurement was 0.25 µL. Therefore, we successfully developed the FPIA system that enables rapid and easy quantification of SARS-CoV-2 antibody. It is believed that our FPIA system will facilitate rapid on-site identification of infected persons and deepen understanding of the immune response to COVID-19.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Anticuerpos Antivirales , Inmunoensayo de Polarización Fluorescente , Humanos , Pandemias , SARS-CoV-2
9.
ACS Omega ; 6(12): 8340-8345, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33817494

RESUMEN

Analytical methods with fluorescence detection are in widespread use for detecting low abundance analytes. Here, we report a simple method for fluorescence signal amplification utilizing a structure of an azide-unit pendant water-soluble photopolymer (AWP) in a microchannel. The AWP is a poly(vinyl alcohol)-based photocross-linkable polymer, which is often used in biosensors. We determined that the wall-like structure of the AWP (AWP-wall) constructed in a microchannel functioned as an amplifier of a fluorescence signal. When a solution of fluorescent molecules was introduced into the microchannel having the AWP-wall, the fluorescent molecules accumulated inside the AWP-wall by diffusion. Consequently, the fluorescence intensity inside the AWP-wall increased locally. Among the fluorescent molecules considered in this paper, 9H-(1,3-dichloro-9,9-dimethylacridin-2-one-7-yl) (DDAO) showed the highest efficiency of fluorescence signal amplification. We prepared a calibration curve for DDAO using the fluorescence intensity inside the AWP-wall, and the sensitivity was 5-fold that for the microchannel without the AWP-wall. This method realizes the improved sensitivity of fluorescence detection easily because the fluorescence signal was amplified only by injecting the solution into the microchannel having the AWP-wall. Furthermore, since this method is not limited to only the use of microchannel, we expect it to be applicable in various fields.

10.
ACS Sens ; 6(3): 1094-1102, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33660502

RESUMEN

The development of low-cost, user-friendly paper-based analytical devices (PADs) that can easily measure target chemicals is attracting attention. However, most PADs require manipulation of the sample using sophisticated micropipettes for quantitative analyses, which restricts their user-friendliness. In addition, immobilization of detection molecules to cellulose fibers is essential for achieving good measuring ability as it ensures the homogeneity of color development. Here, we have described a dip-type PAD that does not require pipette manipulation for sample introduction and immobilization of detection molecules to cellulose fibers and its application to ascorbic acid (AA) and pH assays. The PAD consisted of a dipping area and two channels, each with two detection zones. The developed PADs show color distribution in the two detection zones depending on the sample flow from the dipping area. In comparison with a PAD that has one detection zone at the end of the channel, our developed device achieved higher sensitivity (limit of detection (LOD), 0.22 mg/mL) and reproducibility (maximum coefficient of variation (CV), 2.4%) in AA detection. However, in pH detection, the reproducibility of the PAD with one detection zone at the end of the channel (maximum CV, 21%) was worse than that with two zones (maximum CV, 11%). Furthermore, a dipping time over 3 s did not affect color formation or calibration curves in AA detection: LODs at 3 and 30 s dipping time were 18 and 5.8 µg/mL, respectively. The simultaneous determination of AA and pH in various beverages was performed with no significant difference compared to results of the conventional method.


Asunto(s)
Colorimetría , Calibración , Límite de Detección , Reproducibilidad de los Resultados
11.
Anal Bioanal Chem ; 413(18): 4619-4623, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33547481

RESUMEN

Nowadays, the diagnosis of viral infections is receiving broad attention. We have developed a non-competitive fluorescence polarization immunoassay (NC-FPIA), which is a separation-free immunoassay, for a virus detection. H5 subtype avian influenza virus (H5-AIV) was used as a model virus for the proof of concept. The fluorescein-labeled Fab fragment that binds to H5 hemagglutinin was used for NC-FPIA. The purified H5-AIV which has H5 hemagglutinin was mixed with the fluorescein-labeled Fab fragment. After that, the degree of fluorescence polarization was measured with a portable FPIA analyzer. H5-AIV was successfully detected with an incubation time of 15 min. In addition, the portable FPIA analyzer enables performance of on-site NC-FPIA with a sample volume of 20 µL or less. This is the first research of detecting a virus particle by FPIA. This NC-FPIA can be applied to rapid on-site diagnosis of various viruses.


Asunto(s)
Inmunoensayo de Polarización Fluorescente/métodos , Subtipo H5N1 del Virus de la Influenza A/aislamiento & purificación , Gripe Aviar/virología , Animales , Pollos , Inmunoensayo de Polarización Fluorescente/instrumentación , Subtipo H5N1 del Virus de la Influenza A/genética , Reacción en Cadena de la Polimerasa , Sensibilidad y Especificidad
12.
Anal Chim Acta ; 1144: 85-95, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33453801

RESUMEN

Competitive immunoassays comprise the standard means of detecting small molecules. However, conventional methods using microwells are difficult to apply during point-of-care tests (POCT) because they require complicated handling and are time consuming. Although paper-based analytical devices (PAD) have received considerable focus because of their rapid and straightforward operation, only a few devices have been proposed for competitive immunoassays. Herein, we describe a novel universal PAD format with a 3-dimensional configuration for competitive immunoassays that rapidly and sensitively detects small molecules. The proposed device comprised a layered structure with uniform color formation and high capture efficiency between antigen and antibody that results in rapid and reproducible results. The device rapidly (90 s) assayed biotin as a model target, with a limit of detection (LOD) of 5.08 ng mL-1, and detected progesterone with an LOD of 84 pg mL-1 within 5 min. Moreover, sample volumes and reagent consumption rates were minimized. Thus, our device could be applied to competitive immunoassays of various small molecules in POCT.


Asunto(s)
Anticuerpos , Biotina , Inmunoensayo , Indicadores y Reactivos , Límite de Detección
13.
ACS Appl Bio Mater ; 4(2): 1783-1793, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-35014524

RESUMEN

Size-controlled lipid nanoparticle (LNP)-based DNA/RNA delivery is a leading technology for gene therapies. For DNA/RNA delivery, typically, a cationic lipid is used to encapsulate DNA/RNA into LNPs. However, the use of the cationic lipid leads to cytotoxicity. In contrast, noncationic NPs, such as exosomes, are ideal nanocarriers for DNA/RNA delivery. However, the development of a simple one-step method for the production of size-controlled noncationic NPs encapsulating DNA/RNA is still challenging because of the lack of electrostatic interactions between the cationic lipid and negatively charged DNA/RNA. Herein, we report a microfluidic-based one-step method for the production of size-controlled noncationic NPs encapsulating small interfering RNA (siRNA). Our microfluidic device, named iLiNP, enables the efficient encapsulation of siRNA, as well as control over the NP size, by varying the flow conditions. We applied this method to produce size-controlled exosome-like NPs. The siRNA-loaded exosome-like NPs did not show in vitro cytotoxicity at a high siRNA dosage. In addition, we investigated the effect of the size of the exosome-like NPs on the target gene silencing and found that the 40-50 nm-sized NPs suppressed target protein expression at a dose of 20 nM siRNA. The iLiNP-based one-step production method for size-controlled noncationic-NP-encapsulated RNA is a promising method for the production of artificial exosomes and functionally modified exosomes for gene and cell therapies.


Asunto(s)
Materiales Biocompatibles/química , Dispositivos Laboratorio en un Chip , Nanopartículas/química , ARN Interferente Pequeño/química , Exosomas/química , Células HeLa , Humanos , Ensayo de Materiales , Tamaño de la Partícula , Células Tumorales Cultivadas
14.
RSC Adv ; 11(3): 1430-1439, 2021 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35424092

RESUMEN

Sub 100 nm-sized lipid nanoparticles (LNPs) have been widely used in drug delivery systems (DDSs). The size of the LNPs is an important parameter for the DDS performance, such as biodistribution and gene silencing using siRNAs. However, the LNPs prepared by the conventional preparation method show a wide size distribution. To improve the LNP size distribution, we developed a microfluidic device, named the iLiNP™ device, in a previous study. This device could produce LNPs in the size range of 20 to 150 nm, but the size distribution of the large-sized LNPs needs to be further improved. From the viewpoint of the LNP formation process, a homogeneous and slow rate dilution of ethanol plays an important role in improving the large-size LNP size distribution. In this study, we developed a three-dimensional, symmetrically assembled microfluidic device named the 3D-iLiNP device with the aim of precise size control of large-sized LNPs. We designed the 3D-iLiNP device using a computational fluid dynamics simulation and demonstrated that the 3D-iLiNP device can improve the LNP size distribution. The gene silencing activity of four kinds of siRNA-loaded LNPs was investigated via in vitro and in vivo experiments to elucidate the effect of the LNP size distribution. The results revealed that the LNPs with a size between 90 and 120 nm showed higher gene silencing activity than those with other sizes. The 3D-iLiNP device is expected to improve DDS performance by precisely controlling the size of LNPs.

15.
ACS Appl Mater Interfaces ; 12(30): 34011-34020, 2020 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-32667806

RESUMEN

Microfluidic methodologies for preparation of lipid nanoparticles (LNPs) based on an organic solvent injection method enable precise size control of the LNPs. After preparation of LNPs, the organic solvent injection method needs some post-treatments, such as overnight dialysis or direct dilution with a buffer solution. LNP production using the microfluidic-based organic solvent injection method is dominated by kinetics rather than thermodynamics. Kinetics of ethanol removal from the inner and outer membranes of LNPs could induce a structural change in the membrane that could lead to fusion of LNPs. However, the effects of microfluidic post-treatment on the final size of LNPs have not been sufficiently understood. Herein, we investigated the effect of the post-treatment processes on the final product size of LNPs in detail. A simple baffle device and a model lipid system composed of a neutral phospholipid (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine, POPC) and cholesterol were used to produce the LNPs. We demonstrated that flow conditions of the post-treatment diluting the remaining ethanol in the LNP suspension affected the final product size of LNPs. Based on the findings, we developed an integrated baffle device composed of an LNP production region and a post-treatment region for a microfluidic-based LNP production system; this integrated baffle device prevented the undesirable aggregation or fusion of POPC LNPs even for the high-lipid-concentration condition. Finally, we applied our concept to small interfering RNA (siRNA) delivery and confirmed that no significant effects due to the continuous process occurred on the siRNA encapsulation efficiency, biological distribution, and knockdown activity. The microfluidic post-treatment method is expected to contribute to the production of LNPs for practical applications and the development of novel LNP-based nanomedicines.


Asunto(s)
Lípidos/química , Microfluídica , Nanopartículas/química , ARN Interferente Pequeño/metabolismo , Transfección/métodos , Animales , Colesterol/química , Factor VII/antagonistas & inhibidores , Factor VII/genética , Factor VII/metabolismo , Hepatocitos/citología , Hepatocitos/metabolismo , Hepatocitos/patología , Ratones , Ratones Endogámicos ICR , Microscopía Confocal , Fosfatidilcolinas/química , Interferencia de ARN , ARN Interferente Pequeño/química
16.
ACS Omega ; 5(28): 17199-17206, 2020 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-32715205

RESUMEN

Preparation of high-quality protein crystals is a major challenge in protein crystallography. Natural convection is considered to be an uncontrollable factor of the crystallization process at the ground level as it disturbs the concentration gradient around the growing crystal, resulting in lower-quality crystals. A microfluidic environment expects an imitated microgravity environment because of the small Gr number. However, the mechanism of protein crystal growth in the microfluidic device was not elucidated due to limitations in measuring the crystal growth process within the device. Here, we demonstrate the real-time measurement of protein crystal growth rates within the microfluidic devices by laser confocal microscopy with differential interference contrast microscopy (LCM-DIM) at the nanometer scale. We confirmed the normal growth rates in the 20 and 30 µm-deep microfluidic device to be 42.2 and 536 nm/min, respectively. In addition, the growth rate of crystals in the 20 µm-deep microfluidic device was almost the same as that reported in microgravity conditions. This phenomenon may enable the development of more accessible alternatives to the microgravity environment of the International Space Station.

17.
ACS Sens ; 5(5): 1287-1294, 2020 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-32283919

RESUMEN

Lithium carbonate is an effective medicine for the treatment of the bipolar disorder, but the concentration of lithium in the patient's blood must be frequently monitored because of its toxicity. To date, no colorimetric methods of lithium ion detection in whole blood without pretreatment have been reported. Here, we report a colorimetric paper-based device that allows point-of-care testing in one step. This device is composed of two paper-based elements linked to each other: a blood cell separation unit and a colorimetric detection unit. After a portion of whole blood has been placed on the end of the separation unit, plasma in the sample is automatically transported to the detection unit, which displays a diagnostic color. The key feature of this device is its simple, user-friendly operation. The limit of detection is 0.054 mM and the coefficient of variance is below 6.1%, which are comparable to those of conventional instruments using the same colorimetric reaction. Furthermore, we achieved high recovery (>90%) and reproducibility (<9.8%) with spiked human blood samples. Thus, the presented device provides an alternative method for the regular monitoring of lithium concentrations in the treatment of bipolar disorder by augmenting the coefficient of variation (maximum value, 6.1%).


Asunto(s)
Colorimetría , Litio , Humanos , Iones , Papel , Reproducibilidad de los Resultados
18.
Sens Actuators B Chem ; 316: 128160, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32322135

RESUMEN

A rapid, facile and selective detection of anti-H5 subtype avian influenza virus (AIV) antibody in serum by fluorescence polarization immunoassay (FPIA) was achieved. A fragment of recombinant H5 subtype AIV hemagglutinin was produced and labeled with fluorescein to use it as a labeled antigen in FPIA. This labeled antigen was mixed with anti-AIV sera (H1-H16 subtypes) and FP of the mixture was measured using a portable FP analyzer on a microdevice. It was found that FP increased in proportion to the concentration of anti-H5 AIV antibody (serum) and was significantly higher than FP obtained with the other sera. The selective detection of anti-H5 subtype AIV antibody was confirmed. The required volume of original sample was 2 µL and analysis time was within 20 min. This detection system realizes an efficient on-site diagnosis and surveillance of AIV.

19.
Chem Sci ; 11(34): 9072-9087, 2020 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-34094189

RESUMEN

Room-temperature (RT) protein crystallography provides significant information to elucidate protein function under physiological conditions. In particular, contrary to typical binding assays, X-ray crystal structure analysis of a protein-ligand complex can determine the three-dimensional (3D) configuration of its binding site. This allows the development of effective drugs by structure-based and fragment-based (FBDD) drug design. However, RT crystallography and RT crystallography-based protein-ligand complex analyses require the preparation and measurement of numerous crystals to avoid the X-ray radiation damage. Thus, for the application of RT crystallography to protein-ligand complex analysis, the simultaneous preparation of protein-ligand complex crystals and sequential X-ray diffraction measurement remain challenging. Here, we report an RT crystallography technique using a microfluidic protein crystal array device for protein-ligand complex structure analysis. We demonstrate the microfluidic sorting of protein crystals into microwells without any complicated procedures and apparatus, whereby the sorted protein crystals are fixed into microwells and sequentially measured to collect X-ray diffraction data. This is followed by automatic data processing to calculate the 3D protein structure. The microfluidic device allows the high-throughput preparation of the protein-ligand complex solely by the replacement of the microchannel content with the required ligand solution. We determined eight trypsin-ligand complex structures for the proof of concept experiment and found differences in the ligand coordination of the corresponding RT and conventional cryogenic structures. This methodology can be applied to easily obtain more natural structures. Moreover, drug development by FBDD could be more effective using the proposed methodology.

20.
ACS Omega ; 4(15): 16683-16688, 2019 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-31616851

RESUMEN

Avian influenza virus (AIV) infection, caused by influenza virus type A, is an infectious, acute respiratory disease of birds related to influenza outbreaks worldwide. The highly pathogenic AIV subtype H5N1 has crossed species barriers to infect mammals, including humans, with fatal outcomes and has received attention as a potential pandemic threat. A rapid and timely detection in poultry is vitally important to prevent the virus spread. Despite their great sensitivity, conventional detection methods such as real-time reverse transcription-polymerase chain reaction and the agar gel precipitation test are time-consuming and labor-intensive and require special training. In this work, an immunowall device was evaluated as an easier and faster way for detecting AIV H5-hemagglutinin (AIV H5-HA). For detection, fluorescence-labeled or enzyme-labeled antibody was employed as a labeling antibody in a sandwich immunoassay. Both were shown in this paper to be easier and faster assays for detection compared with the conventional enzyme-linked immunosorbent assay (ELISA) kit. In addition, high selectivity was achieved for AIV H5-HA detection after the evaluation of other different HA virus subtypes. The limit of detection was 0.23 ng/mL for the enzyme-labeled antibody. This value was equivalent to that of the conventional ELISA kit but 8 times faster (31 min compared to 260 min). The detection range was 0.23-100 ng/mL. The immunowall device with the enzyme-labeled antibody offers a rapid, sensitive, selective, and simple immunoassay system for future H5 AIV real sample detection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA