Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Heart Rhythm ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38925335

RESUMEN

BACKGROUND: Early recurrence of atrial tachyarrhythmias (ERAT) within 3 months of thermal ablation for atrial fibrillation (AF) is common and often considered transient. Pulsed field ablation (PFA) is a nonthermal energy source in which ERAT is not well described. OBJECTIVE: The purpose of this study was to analyze ERAT in patients with AF undergoing PFA in the Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF (PULSED AF) trial. METHODS: This analysis included 154 (52.4%) paroxysmal AF and 140 (47.6%) persistent AF who had ≥10 rhythm assessments during the 90-day blanking period. ERAT was defined as any instance of ≥30 seconds of AF, atrial flutter, or atrial tachycardia on transtelephonic monitoring (weekly and symptomatic) or ≥10 seconds on electrocardiography (at 3 months), both within 90 days. Late recurrence of atrial tachyarrhythmias (LRAT) was defined as observed atrial tachyarrhythmias between 90 days and 12 months. RESULTS: The overall prevalence of ERAT was 27.1% in patients with paroxysmal AF and 31.6% in patients with persistent AF. In patients with ERAT, 73% had ERAT onset within the first month of the procedure. The presence of ERAT was associated with LRAT in patients with paroxysmal AF (hazard ratio 6.4; 95% confidence interval 3.6-11.3) and patients with persistent AF (hazard ratio 3.8; 95% confidence interval 2.2-6.6). Yet, in 29.4% of patients with paroxysmal AF and 34.3% of patients with persistent AF with ERAT, LRAT was not observed. LRAT was positively correlated with the number of ERAT observations. CONCLUSION: ERAT after PFA predicted LRAT in patients with paroxysmal and persistent AF. However, the concept of a blanking period after PFA is still valid, as approximately one-third of patients with ERAT did not continue to have LRAT during follow-up and may not need reablation.

2.
Nat Med ; 30(8): 2303-2310, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38760584

RESUMEN

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/terapia , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Resultado del Tratamiento , Método Simple Ciego , Recurrencia
3.
J Drugs Dermatol ; 22(5): 496-501, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37133483

RESUMEN

Dermatologic surgeons are encountering more patients on antithrombotic agents. There are no established consensus guidelines for managing antithrombotic agents in the perioperative period. We provide an updated overview of antithrombotic agents in dermatologic surgery and management of such agents in the perioperative period with additional unique perspectives from cardiology and pharmacy. A literature search of PubMed and Google Scholar was performed to review the English-language medical literature. The landscape of antithrombotic therapy is changing with a notable rise in the use of direct oral anticoagulants (DOACs.) While no consensus guidelines exist, most studies recommend continuing antithrombotic therapy in the perioperative period with appropriate lab monitoring, when applicable. However, recent data suggest it is safe to hold DOACs in the perioperative period. As antithrombotic therapy evolves, the dermatologic surgeon needs to remain current with the most recent available data. Where data are limited, a multidisciplinary approach to managing these agents in the perioperative period is essential. J Drugs Dermatol. 2023;22(5): doi:10.36849/JDD.7456.


Asunto(s)
Cardiología , Fibrinolíticos , Humanos , Fibrinolíticos/efectos adversos , Anticoagulantes/efectos adversos , Procedimientos Quirúrgicos Dermatologicos/efectos adversos
4.
Am J Cardiol ; 197: 24-33, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37137251

RESUMEN

Data regarding the impact of pacing on outcomes after transcatheter aortic valve implantation (TAVI) is evolving especially with regards to pre-existing permanent pacemaker (PPM). We examined the impact of new and previous PPM on the clinical and hemodynamic outcomes after SAPIEN-3 TAVI. We included all consecutive patients who underwent transfemoral TAVI using SAPIEN-3 valve from 2015 to 2018 at our institution. Among 1,028 patients, 10.2% required a new PPM within 30 days, whereas 14% had a pre-existing PPM. The presence of either previous or new PPM had no impact on the 3-year mortality (log-rank p = 0.6) or 1-year major adverse cardiac and cerebrovascular events (log-rank p = 0.65). New PPM was associated with lower left ventricular (LV) ejection fraction (LVEF) at both 30 days (54.4 ± 11.3% vs 58.4 ± 10.1%, p = 0.001) and 1 year (54.2 ± 12% vs 59.1 ± 9.9%, p = 0.009) than no PPM. Similarly, previous PPM was associated with worse LVEF at 30 days (53.6 ± 12.3%, p <0.001) and 1 year (55.5 ± 12.1%, p = 0.006) than no PPM. Interestingly, new PPM was associated with lower 1-year mean gradient (11.4 ± 3.8 vs 12.6 ± 5.6 mm Hg, p = 0.04) and peak gradient (21.3 ± 6.5 vs 24.1 ± 10.4 mm Hg, p = 0.01), despite no baseline differences. Previous PPM was also associated with lower 1-year mean gradient (10.3 ± 4.4 mm Hg, p = 0.001) and peak gradient (19.4 ± 8 mm Hg, p <0.001) and higher Doppler velocity index (0.51 ± 0.12 vs 0.47 ± 0.13, p = 0.039). Moreover, 1-year LV end-systolic volume index was higher with new (23.2 ± 16.1 vs 20 ± 10.8 ml/m2, p = 0.038) and previous PPM (24.5 ± 19.7, p = 0.038) than no PPM. Previous PPM was associated with higher moderate-to-severe tricuspid regurgitation (35.3% vs 17.7%, p <0.001). There were no differences regarding the rest of the studied echocardiographic outcomes at 1 year. In conclusion, new and previous PPM did not affect 3-year mortality or 1-year major adverse cardiac and cerebrovascular events; however, they were associated with worse LVEF, higher 1-year LV end-systolic volume index, and lower mean and peak gradients on follow-up than no PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
5.
Am Heart J ; 259: 30-41, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36642226

RESUMEN

BACKGROUND: The impact of using direct-to-consumer wearable devices as a means to timely detect atrial fibrillation (AF) and to improve clinical outcomes is unknown. METHODS: Heartline is a pragmatic, randomized, and decentralized application-based trial of US participants aged ≥65 years. Two randomized cohorts include adults with possession of an iPhone and without a history of AF and those with a diagnosis of AF taking a direct oral anticoagulant (DOAC) for ≥30 days. Participants within each cohort are randomized (3:1) to either a core digital engagement program (CDEP) via iPhone application (Heartline application) and an Apple Watch (Apple Watch Group) or CDEP alone (iPhone-only Group). The Apple Watch Group has the watch irregular rhythm notification (IRN) feature enabled and access to the ECG application on the Apple Watch. If an IRN notification is issued for suspected AF then the study application instructs participants in the Apple Watch Group to seek medical care. All participants were "watch-naïve" at time of enrollment and have an option to either buy or loan an Apple Watch as part of this study. The primary end point is time from randomization to clinical diagnosis of AF, with confirmation by health care claims. Key secondary endpoint are claims-based incidence of a 6-component composite cardiovascular/systemic embolism/mortality event, DOAC medication use and adherence, costs/health resource utilization, and frequency of hospitalizations for bleeding. All study assessments, including patient-reported outcomes, are conducted through the study application. The target study enrollment is approximately 28,000 participants in total; at time of manuscript submission, a total of 26,485 participants have been enrolled into the study. CONCLUSION: The Heartline Study will assess if an Apple Watch with the IRN and ECG application, along with application-facilitated digital health engagement modules, improves time to AF diagnosis and cardiovascular outcomes in a real-world environment. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04276441.


Asunto(s)
Fibrilación Atrial , Embolia , Tromboembolia , Adulto , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Tromboembolia/diagnóstico , Tromboembolia/etiología , Tromboembolia/prevención & control , Hemorragia
6.
J Cardiovasc Electrophysiol ; 34(3): 693-699, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36640426

RESUMEN

INTRODUCTION: Contact force has been used to titrate lesion formation for radiofrequency ablation. Pulsed field ablation (PFA) is a field-based ablation technology for which limited evidence on the impact of contact force on lesion size is available. METHODS: Porcine hearts (n = 6) were perfused using a modified Langendorff set-up. A prototype focal PFA catheter attached to a force gauge was held perpendicular to the epicardium and lowered until contact was made. Contact force was recorded during each PFA delivery. Matured lesions were cross-sectioned, stained, and the lesion dimensions measured. RESULTS: A total of 82 lesions were evaluated with contact forces between 1.3 and 48.6 g. Mean lesion depth was 4.8 ± 0.9 mm (standard deviation), mean lesion width was 9.1 ± 1.3 mm, and mean lesion volume was 217.0 ± 96.6 mm3 . Linear regression curves showed an increase of only 0.01 mm in depth (depth = 0.01 × contact force + 4.41, R2 = 0.05), 0.03 mm in width (width = 0.03 × contact force + 8.26, R2 = 0.13) for each additional gram of contact force, and 2.20 mm3 in volume (volume = 2.20 × contact force + 162, R2 = 0.10). CONCLUSION: Increasing contact force using a bipolar, biphasic focal PFA system has minimal effects on acute lesion dimensions in an isolated porcine heart model and achieving tissue contact is more important than the force with which that contact is made.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Porcinos , Animales , Ablación por Catéter/métodos , Ablación por Radiofrecuencia/métodos , Pericardio , Catéteres , Irrigación Terapéutica
7.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36259719

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Medición de Resultados Informados por el Paciente
8.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378620

RESUMEN

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Arritmias Cardíacas , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
9.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36378803

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Humanos , Teorema de Bayes , Reproducibilidad de los Resultados , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Resultado del Tratamiento
10.
Heart Rhythm O2 ; 3(5): 466-473, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36340491

RESUMEN

Background: Implant site hematoma is a known complication of cardiac device procedures and can lead to major consequences. Objectives: To evaluate risk factors for hematoma and further understand the relationship between anticoagulant (AC), antiplatelet (AP) use, and hematoma development. Methods: We included 6800 patients from the WRAP-IT trial. To assess baseline and procedural characteristics associated with hematoma within the first 30 days postprocedure, a stepwise Cox regression model was implemented with minimal Akaike information criterion. Cox regressions were also used to evaluate AC/AP use and hematoma risk. Results: The overall rate of hematoma was 2.2%. The model identified 11 baseline and procedural characteristics associated with hematoma risk. AC use (hazard ratio [HR]: 2.44, P < .001), lower body mass index (HR: 1.06, P < .001), and history of valve surgery (HR: 2.11, P < .001) were associated with the highest risk. AP use, male sex, history of coronary artery disease, existing pocket, history of nonischemic cardiomyopathy, number of previous cardiac implantable electronic device (CIED) procedures, procedure time, and lead revision were associated with moderate risk. Antithrombotic use was high overall (86%) and AC+AP use was highly predictive of hematoma risk. Regardless of AC status, AP use was associated with an almost doubling of risk vs no AP (HR = 1.85, P = .0006) in the general cohort. Interruption of AC was associated with the lowest hematoma risk (HR = 2.35) while heparin bridging (HR = 4.98) and AP use vs no AP use (HR = 1.85) was associated with the highest hematoma risk. Conclusion: The results of this analysis highlight risk factors associated with the development of hematoma in patients undergoing CIED procedures and can inform antithrombotic management.

11.
Circ Arrhythm Electrophysiol ; 15(11): e010779, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36306341

RESUMEN

BACKGROUND: Difficulty of lead extraction does not track well with procedural complications, but several small retrospective studies have lead fibrosis on computed tomography as an important indicator of difficult lead extraction. The purpose of the present study was to apply a standardized gated cardiac computed tomography (CT) protocol to assess fibrosis and study it prospectively to examine the need for powered sheaths and risk outcomes. METHODS: We performed a prospective, blinded, multicenter, international study at high-volume lead extraction centers and included patients referred for transvenous lead extraction with at least one lead with a dwell time >1 year and ability to receive a cardiac CT. The degree of fibrosis (as measured by amount of lead adherence to vessel wall) was graded on a scale of 1 to 4 by dedicated CT readers in 3 zones (vein entry to superior vena cava, superior vena cava, and right atrium to lead tip). The primary outcome of the study was number of extractions requiring powered sheaths at zone 2 for each fibrosis group. RESULTS: A total of 200 patients were enrolled in the trial with 196 completing full gated CT and lead extraction analysis. The primary endpoint of powered sheath (laser and mechanical) sheath use was significantly higher in patients with higher fibrosis seen on CT (scores 3+4; 67.8%) at the zone 2 compared to patients with lower fibrosis (scores 1+2; 38.6%; P<0.001). There were 5 major complications with 3 vascular lacerations all occurring in zone 2 in the study. CONCLUSIONS: Gated, contrasted CT can predict the need for powered sheaths by identification of fibrosis but did not identify an absolute low-risk cohort who would not need powered sheaths. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03772704.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Vena Cava Superior , Estudios Retrospectivos , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Fibrosis
12.
Eur Heart J Open ; 2(2): oeac014, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35919121

RESUMEN

Aims: The 2021 European Society of Cardiology guidelines recommend early pacemaker implantation in pre-existing right bundle branch block (RBBB) patients who develop PR prolongation or QRS axis change after transcatheter aortic valve implantation (TAVI). We aimed to evaluate this recommendation in TAVI recipients with a balloon-expandable valve (BEV). Methods and results: We retrospectively reviewed 188 pre-existing RBBB patients without pre-existing permanent pacemaker (PPM) who underwent TAVI with a BEV at our institution in 2015-19. Patients who developed high-degree atrioventricular block (HAVB) during TAVI or within 24 h post-TAVI were excluded. Eligible patients were divided according to the guideline-directed criteria (ΔPR interval ≥20 ms and/or QRS axis change). Patients who met the criteria (n = 102, 54.3%), compared with those who did not (n = 86), had a higher prevalence of baseline right axis deviation and were more likely to have received a larger valve with greater oversizing. The 30-day delayed HAVB rate did not differ significantly between the groups (3.9% vs. 4.7%, P = 1.00; odds ratio = 0.84, 95% confidence interval = 0.20-3.45). There was also no significant difference in terms of death (5.0% vs. 8.4% at 1 year; overall log-rank P = 0.94) or a composite of death or PPM implantation (14.8% vs. 16.6% at 1 year; overall log-rank P = 0.94) during follow-up post-TAVI. The majority of PR prolongations (79.4%) and QRS axis changes (52.0%) regressed within the following 24 h. Conclusion: The present data did not demonstrate an association of significant changes in PR interval or QRS axis with heightened delayed HAVB risk in BEV recipients with pre-existing RBBB. Prospective studies are warranted to confirm these findings.

13.
J Cardiovasc Electrophysiol ; 33(9): 1994-2000, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35689504

RESUMEN

INTRODUCTION: Pulmonary venous (PV) electrical recovery underlies most arrhythmia recurrences after atrial fibrillation (AF) ablation. Little is known about procedural profiles and outcomes of patients with electrically silent PVs upon redo ablation for AF. METHODS: In a prospectively maintained registry, we enrolled 838 consecutive patients (2013-2016) undergoing redo ablation procedures. Ablation procedures targeted the PVs, the PV antra, and non-PV sites at operators' discretion. Procedural profiles and clinical outcomes were assessed. The primary outcome was freedom from AF after a 3-month blanking period. The secondary outcome was improvement in quality of life. RESULTS: Most patients undergoing redo AF ablation (n = 684, 82%) had PV reconnection while the remaining 154 (18%) had electrically silent PVs. Patients with recurrent AF and electrically silent PVs were older (66 vs. 64 years, p = .02), had more prior ablation procedures (median 2 IQR 1-3 vs 1 IQR 1-2 p = .001), were more likely to have non-paroxysmal AF (62% vs. 49%, p = .004) and atrial flutter (48% vs. 29%, p = .001) and had significantly larger left atrial volumes (89 vs. 81 ml, p = .003). Patients with silent PVs underwent a more extensive non-PV ablation strategies with antral extension of prior ablation sets in addition to ablation of the roof, appendage, inferior to the right PVs, peri-mitral flutter lines, cavotricuspid isthmus lines and ablation in the coronary sinus. Upon one year of follow-up, patients with electrically silent PVs were less likely to remain free from recurrent atrial arrhythmias (64% vs. 76%, p = .008). Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. CONCLUSION: Rhythm control with extensive ablation allowed maintenance of sinus rhythm in about two thirds of patients with silent PVs during redo AF ablation procedures. Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. This remains a challenging group of patients, highlighting the need to better understand non-PV mediated AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
15.
JACC Clin Electrophysiol ; 8(4): 498-510, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35450605

RESUMEN

OBJECTIVES: This study sought to examine the effect of the return electrode's surface area on bipolar RFA lesion size. BACKGROUND: Bipolar radiofrequency ablation (RFA) is typically performed between 2 3.5-mm tip catheters serving as active and return electrodes. We hypothesized that increasing the surface area of the return electrode would increase lesion dimensions by reducing the circuit impedance, thus increasing the current into a larger tissue volume enclosed between the electrodes. METHODS: In step 1, ex vivo bipolar RFA was performed between 3.5-mm and custom-made return electrodes with increasing surface areas (20, 80, 180 mm2). In step 2, ex vivo bipolar RFA was performed between 3.5-mm and 3.5-mm or 8-mm electrode catheters positioned perpendicular or parallel to the tissue. In step 3, in vivo bipolar RFA was performed between 3.5-mm and either 3.5-mm or 8-mm parallel electrode at the: 1) left ventricular summit; 2) interventricular septum; and 3) healed anterior infarction. RESULTS: In step 1, increasing the surface area of the return electrode resulted in lower circuit impedance (R = -0.65; P < 0.001), higher current (R = +0.80; P < 0.001), and larger lesion volume (R = +0.88; P < 0.001). In step 2, an 8-mm return electrode parallel to tissue produced larger and deeper lesions compared with a 3.5-mm return electrode (P = 0.014 and P = 0.02). Similarly, in step 3, compared with a 3.5-mm, bipolar RFA with an 8-mm return electrode produced larger (volume: 1,525 ± 871 mm3 vs 306 ± 310 mm3, respectively; P < 0.001) and more transmural lesions (88% vs 0%; P < 0.001). CONCLUSIONS: Bipolar RFA using an 8-mm return electrode positioned parallel to the tissue produces larger lesions in comparison with a 3.5-mm return electrode.


Asunto(s)
Ablación por Catéter , Ablación por Catéter/métodos , Electrodos , Diseño de Equipo , Ventrículos Cardíacos/cirugía , Humanos
16.
Am J Cardiol ; 168: 117-127, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35045936

RESUMEN

New-onset left bundle branch block (LBBB) is common after transcatheter aortic valve implantation (TAVI) but can resolve in the post-TAVI period. We sought to examine the incidence, predictors, and outcomes of early resolution of new-onset LBBB among TAVI recipients with a SAPIEN 3 (S3) valve. Among 1,203 S3-TAVI recipients without a pre-existing pacemaker or wide QRS complex at our institution between 2016 and 2019, we identified 143 patients who developed new-onset LBBB during TAVI and divided them according to the resolution or persistence of LBBB by the next day post-TAVI to compare high-degree atrioventricular block (HAVB) and permanent pacemaker (PPM) rates. Patients with resolved LBBB (n = 74, 52%), compared with those with persistent LBBB, were more often women and had a shorter QRS duration at baseline and post-TAVI, with a smaller S3 size and a shallower implantation depth. A multivariable logistic regression model demonstrated significant associations of post-TAVI QRS duration (per 10 ms increase, odds ratio = 0.60 [95% confidence interval = 0.44 to 0.82]) and implantation depth (per 1-mm-depth-increase, 0.77 [0.61 to 0.97]) with a lower likelihood of LBBB resolution. No patient with resolved LBBB developed HAVB within 30 days post-TAVI. Meanwhile, 8 patients (11.6%) with persistent LBBB developed HAVB. The 2-year PPM rate was significantly higher after persistent LBBB than after resolved LBBB (30.3% vs 4.5%, log-rank p <0.001), mainly driven by higher 30-day PPM rate (18.8% vs 0.0%). In conclusion, about half of new-onset LBBBs that occurred during S3-TAVI resolved by the next day post-TAVI without HAVB. In contrast, new-onset persistent LBBB may need follow-up with ambulatory monitoring within 30 days because of the HAVB risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Arritmias Cardíacas/complicaciones , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Marcapaso Artificial/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Heart Rhythm ; 19(3): 363-371, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34767985

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead monitoring diagnostic alerts facilitate the diagnosis of structural lead failure. OBJECTIVE: The purpose of this study was to prospectively study the performance of Medtronic ICD lead monitoring alerts. METHODS: A prespecified ancillary substudy, World-Wide Randomized Antibiotic Envelope Infection Prevention Trial, was conducted in patients with an ICD with all available alerts enabled. The investigators reported possible lead system events (LSEs), with or without an alert. An independent committee reviewed all data and classified events as lead failure, other LSE, or nonlead system events (NLEs). RESULTS: In 4942 patients who were followed for 19.4 ± 8.7 months, there were 124 alerts (65 LSEs, 59 NLEs) and 19 LSEs without an alert. Lead monitoring alerts had 100% sensitivity for the 48 adjudicated lead failures (95% confidence interval 92.6%-100%) and for 10 events adjudicated as either lead failure or connection issue. The positive predictive value of alerts for lead failure was 38.7% (48 of 124). For 34 pace-sense lead failures, an alert that incorporated oversensing was more sensitive than the pacing impedance threshold alert (33 patients [97.1%] vs 9 patients [26.5%]; P < .0001). However, the sensitivity was only 13.6% for lead dislodgments or perforations. Inappropriate shocks occurred in 2 patients with pace-sense lead failure (5.9%). No patient had unnecessary lead replacement for any of the NLEs. CONCLUSION: In this first real-world prospective study, lead monitoring alerts had 100% sensitivity for identifying lead failures. Although their positive predictive value was modest, no false-positive alerts resulted in an unnecessary lead replacement. For the diagnosis of pace-sense lead failure, an alert for oversensing was more sensitive than a pacing impedance threshold alert. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02277990.


Asunto(s)
Desfibriladores Implantables , Desfibriladores Implantables/efectos adversos , Impedancia Eléctrica , Falla de Equipo , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos
18.
Heart Rhythm ; 19(3): 381-388, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34801735

RESUMEN

BACKGROUND: Bradyarrhythmias leading to permanent pacemaker (PPM) implantation continue to be a complication after transcatheter aortic valve replacement (TAVR). OBJECTIVE: The purpose of this study was to assess the prevalence of bradyarrhythmias using an electrocardiographic (ECG) extended rhythm recording in patients pre- and post-TAVR and whether they can predict the need for PPM. METHODS: This was a prospective single-center study in patients undergoing TAVR. Patients received an ECG patch for 2 weeks pre-, immediately post-, and 2-3 months post-TAVR. Caring physicians were blinded to the results of the patch except when predefined urgent arrhythmias were detected. The main outcome was the need for PPM implantation after TAVR. RESULTS: We enrolled 110 patients, of whom 96 underwent TAVR and were included in the final analysis. Bradyarrhythmias, defined as a pause of 3 seconds or more, occurred in 5.2%, 12.7%, and 7% of patients pre-, immediately post-, and 2-3 months post-TAVR, respectively. PPM implantation occurred in 12 patients (12.5%), of whom 9 (9.4%) underwent implantation during their index hospitalization while 3 (3.1%) required implantation postdischarge for indications other than heart block. No patients required PPM after receiving an ECG patch 2-3 months post-TAVR. Significant baseline predictors for the need for PPM included the presence of right bundle branch block and increased QRS duration. Bradyarrhythmias detected by the ECG patch did not predict the need for PPM at either the index hospitalization or the follow-up period. CONCLUSION: Bradyarrhythmias are common and can be detected with extended ECG monitoring before and after TAVR; however, in our study they did not predict the need for PPM after TAVR (ClinicalTrials.gov identifier: NCT03180073).


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Cuidados Posteriores , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Bradicardia/diagnóstico , Bradicardia/epidemiología , Bradicardia/etiología , Electrocardiografía , Humanos , Marcapaso Artificial/efectos adversos , Alta del Paciente , Estudios Prospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Struct Heart ; 6(3): 100019, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37274547

RESUMEN

Background: In the absence of randomized data, an expert panel recently proposed an algorithm for conduction disturbance management in transcatheter aortic valve implantation (TAVI) recipients. However, external validations of its recommendations are limited. Methods: We retrospectively identified 808 patients without a pre-existing pacing device who underwent transfemoral TAVI with the Sapien 3 valve at our institution in 2018-2019. Patients were grouped based on pre-existing conduction disturbance and immediate post-TAVI electrocardiogram. Timing of temporary pacemaker (TPM) removal and hospital discharge were compared with those of the expert panel recommendations to evaluate the associated risk of TPM reinsertion and permanent pacemaker (PPM) implantation. Results: In most group 1 patients (no electrocardiogram changes without pre-existing right bundle branch block), the timing of TPM removal and discharge were concordant with those of the expert panel recommendations, with low TPM reinsertion (0.8%) and postdischarge PPM (0.8%) rates. In the majority of group 5 patients (procedural high-degree/complete atrioventricular block), TPM was maintained, followed by PPM implantation, compatible with the expert panel recommendations. In contrast, in groups 2-4 (pre-existing/new conduction disturbances), earlier TPM removal than recommended by the expert panel (mostly, immediately after procedure) was feasible in 97.5%-100% of patients, with a low TPM reinsertion rate (0.0%-1.8%); earlier discharge was also feasible in 50.0%-65.5%, with a low 30-day postdischarge PPM rate (0.0%-2.8%) and no 30-day death. Conclusions: Early TPM removal and discharge after TAVI appear safe and feasible in the majority of cases. These data may provide a framework for an early, streamlined hospital discharge plan for TAVI recipients, optimizing both cost savings and patient safety.

20.
Heart Rhythm ; 19(11): 1927-1945, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-37850602

RESUMEN

There are many challenges in the current landscape of electrophysiology (EP) clinical and translational research, including increasing costs and complexity, competing demands, regulatory requirements, and challenges with study implementation. This review seeks to broadly discuss the state of EP research, including challenges and opportunities. Included here are results from a Heart Rhythm Society (HRS) Research Committee member survey detailing HRS members' perspectives regarding both barriers to clinical and translational research and opportunities to address these challenges. We also provide stakeholder perspectives on barriers and opportunities for future EP research, including input from representatives of the U.S. Food and Drug Administration, industry, and research funding institutions that participated in a Research Collaboratory Summit convened by HRS. This review further summarizes the experiences of the heart failure and heart valve communities and how they have approached similar challenges in their own fields. We then explore potential solutions, including various models of research ecosystems designed to identify research challenges and to coordinate ways to address them in a collaborative fashion in order to optimize innovation, increase efficiency of evidence generation, and advance the development of new therapeutic products. The objectives of the proposed collaborative cardiac EP research community are to encourage and support scientific discourse, research efficiency, and evidence generation by exploring collaborative and equitable solutions in which stakeholders within the EP community can interact to address knowledge gaps, innovate, and advance new therapies.


Asunto(s)
Electrofisiología Cardíaca , Ecosistema , Investigación Biomédica Traslacional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...