Artículo en Inglés | MEDLINE | ID: mdl-34990357

RESUMEN

We present an intravascular ultrasound (IVUS) transducer array designed to enable shear wave elasticity imaging (SWEI) of arteries for the detection and characterization of atherosclerotic soft plaques. Using a custom dicing fixture, we have fabricated single-element and axially-segmented array transducer prototypes from 4.6-Fr to 7.6-Fr piezoceramic tubes, respectively. Focused excitation of the array prototype at 4 MHz yielded a focal gain of 5× in intensity, for an estimated 60 mW/cm2 [Formula: see text] and 1.6-MPa negative peak pressure at 4.5-mm range in water. The single-element transducer generated a peak radial displacement of [Formula: see text] in a uniform elasticity phantom, with axial shear waves detectable by an external linear array probe up to 5 mm away from the excitation plane. In a vessel phantom with a soft inclusion, the array prototype generated peak displacements of 2.2 and [Formula: see text] in the soft inclusion and vessel wall regions, respectively. A SWEI image of the vessel phantom was reconstructed, with measured shear wave speed (SWS) of 1.66 ± 0.91 m/s and 0.97 ± 0.59 m/s for the soft inclusion and vessel wall regions, respectively. The array prototype was also used to obtain a SWEI image of an ex vivo porcine artery, with a mean SWS of 3.97 ± 1.12 m/s. These results suggest that a cylindrical intravascular ultrasound (IVUS) transducer array could be made capable of SWEI for atherosclerotic plaque detection in coronary arteries.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Fantasmas de Imagen , Transductores , Ultrasonografía
3.
Nanotheranostics ; 6(1): 62-78, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34976581

RESUMEN

Rationale: To assess treatment effects of 4 complementary miRNAs (miRNA-100/miRNA-122/antimiRNA-10b/antimiRNA-21) encapsulated in a biodegradable PLGA-PEG nanoparticle, administered by an ultrasound-guided microbubble-mediated targeted delivery (UGMMTD) approach in mouse models of hepatocellular carcinoma (HCC). Methods:In vitro apoptotic index was measured in HepG2 and Hepa1-6 HCC cells treated with various combinations of the 4 miRNAs with doxorubicin. Three promising combinations were further tested in vivo by using UGMMTD. 63 HepG2 xenografts in mice were randomized into: group 1, miRNA-122/antimiRNA-10b/antimiRNA-21/US/doxorubicin; group 2, miRNA-100/miRNA-122/antimiRNA-10b/antimiRNA-21/US/doxorubicin; group 3, miRNA-100/miRNA-122/antimiRNA-10b/US/doxorubicin; group 4, miRNA-122/anitmiRNA-10b/antimiRNA-21/doxorubicin; group 5, miRNA-100/miRNA-122/antimiRNA-10b/antimiRNA-21/doxorubicin; group 6, miRNA-100/miRNA-122/antimiRNA-10b/doxorubicin; group 7, doxorubicin only treatment; and group 8, without any treatment. Tumor volumes were measured through 18 days. H&E staining, TUNEL assay, and qRT-PCR quantification for delivered miRNAs were performed. Results:In vivo results showed that UGMMTD of miRNAs with doxorubicin in groups 1-3 significantly (P<0.05) delayed tumor growth compared to control without any treatment, and doxorubicin only from day 7 to 18. On qRT-PCR, levels of delivered miRNAs were significantly (P<0.05) higher in groups 1-3 upon UGMMTD treatment compared to controls. TUNEL assay showed that upon UGMMTD, significantly higher levels of apoptotic cell populations were observed in groups 1-3 compared to controls. Toxicity was not observed in various organs of different groups. Conclusions: UGMMTD of miRNA-100/miRNA-122/antimiRNA-10b/antimiRNA-21 combination improved therapeutic outcome of doxorubicin chemotherapy in mouse models of HCC by substantial inhibition of tumor growth and significant increase in apoptotic index.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , MicroARNs , Animales , Humanos , Ratones , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Microburbujas , MicroARNs/genética , Ultrasonografía Intervencional
4.
Phys Med Biol ; 67(1)2022 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-34933288

RESUMEN

Objective. Speed of sound has previously been demonstrated to correlate with fat concentration in the liver. However, estimating speed of sound in the liver noninvasively can be biased by the speed of sound of the tissue layers overlying the liver. Here, we demonstrate a noninvasive local speed of sound estimator, which is based on a layered media assumption, that can accurately capture the speed of sound in the liver. We validate the estimator using an obese Zucker rat model of non-alcoholic fatty liver disease and correlate the local speed of sound with liver steatosis.Approach.We estimated the local and global average speed of sound noninvasively in 4 lean Zucker rats fed a normal diet and 16 obese Zucker rats fed a high fat diet for up to 8 weeks. The ground truth speed of sound and fat concentration were measured from the excised liver using established techniques.Main Results. The noninvasive, local speed of sound estimates of the livers were similar in value to their corresponding 'ground truth' measurements, having a slope ± standard error of the regression of 0.82 ± 0.15 (R2= 0.74 andp< 0.001). Measurement of the noninvasive global average speed of sound did not reliably capture the 'ground truth' speed of sound in the liver, having a slope of 0.35 ± 0.07 (R2= 0.74 andp< 0.001). Decreasing local speed of sound was observed with increasing hepatic fat accumulation (approximately -1.7 m s-1per 1% increase in hepatic fat) and histopathology steatosis grading (approximately -10 to -13 m s-1per unit increase in steatosis grade). Local speed of sound estimates were highly correlated with steatosis grade, having Pearson and Spearman correlation coefficients both ranging from -0.87 to -0.78. In addition, a lobe-dependent speed of sound in the liver was observed by theex vivomeasurements, with speed of sound differences of up to 25 m s-1(p< 0.003) observed between lobes in the liver of the same animal.Significance.The findings of this study suggest that local speed of sound estimation has the potential to be used to predict or assist in the measurement of hepatic fat concentration and that the global average speed of sound should be avoided in hepatic fat estimation due to significant bias in the speed of sound estimate.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Animales , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Obesidad , Ratas , Ratas Zucker , Sonido , Ultrasonografía/métodos
5.
Artículo en Inglés | MEDLINE | ID: mdl-34723801

RESUMEN

Our previous methodology in local sound speed estimation utilized time delays measured by the cross correlation of delayed full-synthetic aperture channel data to estimate the average speed of sound. However, focal distortions in this methodology lead to biased estimates of the average speed of sound, which, in turn, leads to biased estimates of the local speed of sound. Here, we demonstrate the bias in the previous methodology and introduce a coherence-based average sound speed estimator that eliminates this bias and is computationally much cheaper in practice. Because this coherence-based approach estimates the average sound speed in the medium over an equally spaced grid in depth rather than time, we derive a refined model that relates the local and average speeds of sound as a function of depth in layered media. A fast, closed-form inversion of this model yields highly accurate local sound speed estimates. The root-mean-square (rms) error of local sound speed reconstruction in simulations of two-layer media is 4.6 and 2.5 m/s at 4 and 8 MHz, respectively. This work examines the impact of frequency, f -number, aberration, and reverberation on sound speed estimation. Phantom and in vivo experiments in rats further validate the coherence-based sound speed estimator.


Asunto(s)
Sonido , Animales , Frecuencia Cardíaca , Fantasmas de Imagen , Ratas , Ultrasonografía/métodos
6.
Artículo en Inglés | MEDLINE | ID: mdl-33141665

RESUMEN

Passive cavitation mapping (PCM) algorithms for diagnostic ultrasound arrays based on time exposure acoustics (TEA) exhibit poor axial resolution, which is in part due to the diffraction-limited point spread function of the imaging system and poor rejection by the delay-and-sum beamformer. In this article, we adapt a method for speed of sound estimation to be utilized as a cavitation source localization (CSL) approach. This method utilizes a hyperbolic fit to the arrival times of the cavitation signals in the aperture domain, and the coefficients of the fit are related to the position of the cavitation source. Wavefronts exhibiting poor fit to the hyperbolic function are corrected to yield improved source localization. We demonstrate through simulations that this method is capable of accurate estimation of the origin of coherent spherical waves radiating from cavitation/point sources. The average localization error from simulated microbubble sources was 0.12 ± 0.12mm ( 0.15 ± 0.14λ0 for a 1.78-MHz transmit frequency). In simulations of two simultaneous cavitation sources, the proposed technique had an average localization error of 0.2mm ( 0.23λ0 ), whereas conventional TEA had an average localization error of 0.81mm ( 0.97λ0 ). The reconstructed PCM-CSL image showed a significant improvement in resolution compared with the PCM-TEA approach.


Asunto(s)
Acústica , Microburbujas , Algoritmos , Sonido , Ultrasonografía
7.
Artículo en Inglés | MEDLINE | ID: mdl-33141666

RESUMEN

Passive cavitation mapping (PCM) techniques typically utilize a time-exposure acoustic (TEA) approach, where the received radio frequency data are beamformed, squared, and integrated over time. Such PCM-TEA cavitation maps typically suffer from long-tail artifacts and poor axial resolution with pulse-echo diagnostic arrays. Here, we utilize a recently developed PCM technique based on cavitation source localization (CSL), which fits a hyperbolic function to the received cavitation wavefront. A filtering method based on the root-mean-square error (rmse) of the hyperbolic fit is utilized to filter out spurious signals. We apply a wavefront correction technique to the signals with poor fit quality to recover additional cavitation signals and improve cavitation localization. Validation of the PCM-CSL technique with rmse filtering and wavefront correction was conducted in experiments with a tissue-mimicking flow phantom and an in vivo mouse model of cancer. It is shown that the quality of the hyperbolic fit, necessary for the PCM-CSL, requires an rmse < 0.05 mm2 in order to accurately localize the cavitation sources. A detailed study of the wavefront correction technique was carried out, and it was shown that, when applied to experiments with high noise and interference from multiple cavitating microbubbles, it was capable of effectively correcting noisy wavefronts without introducing spurious cavitation sources, thereby improving the quality of the PCM-CSL images. In phantom experiments, the PCM-CSL was capable of precisely localizing sources on the therapy beam axis and off-axis sources. In vivo cavitation experiments showed that PMC-CSL showed a significant improvement over PCM-TEA and yielded acceptable localization of cavitation signals in mice.


Asunto(s)
Microburbujas , Neoplasias , Acústica , Animales , Artefactos , Ratones , Fantasmas de Imagen
8.
Ultrasound Med Biol ; 47(2): 309-322, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33153807

RESUMEN

Ultrasound and microbubble (USMB)-mediated drug delivery is a valuable tool for increasing the efficiency of the delivery of therapeutic agents to cancer while maintaining low systemic toxicity. Typically, selection of USMB drug delivery parameters used in current research settings are either based on previous studies described in the literature or optimized using tissue-mimicking phantoms. However, phantoms rarely mimic in vivo tumor environments, and the selection of parameters should be based on the application or experiment. In the following study, we optimized the therapeutic parameters of the ultrasound drug delivery system to achieve the most efficient in vivo drug delivery using fluorescent semiconducting polymer nanoparticles as a model nanocarrier. We illustrate that voltage, pulse repetition frequency and treatment time (i.e., number of ultrasound pulses per therapy area) delivered to the tumor can successfully be optimized in vivo to ensure effective delivery of the semiconducting polymer nanoparticles to models of hepatocellular carcinoma. The optimal in vivo parameters for USMB drug delivery in this study were 70 V (peak negative pressure = 3.4 MPa, mechanical index = 1.22), 1-Hz pulse repetition frequency and 100-s therapy time. USMB-mediated drug delivery using in vivo optimized ultrasound parameters caused an up to 2.2-fold (p < 0.01) increase in drug delivery to solid tumors compared with that using phantom-optimized ultrasound parameters.


Asunto(s)
Carcinoma Hepatocelular/tratamiento farmacológico , Sistemas de Liberación de Medicamentos , Neoplasias Hepáticas/tratamiento farmacológico , Microburbujas/uso terapéutico , Ondas Ultrasónicas , Animales , Calibración , Carcinoma Hepatocelular/patología , Modelos Animales de Enfermedad , Femenino , Fluorescencia , Células Hep G2 , Humanos , Neoplasias Hepáticas/patología , Ratones , Necrosis , Trasplante de Neoplasias , Puntos Cuánticos , Terapia por Ultrasonido/instrumentación
9.
Cell Transplant ; 29: 963689720965478, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33028105

RESUMEN

We studied the paracrine function of mesenchymal stem cells (MSCs) derived from various sources in response to pulsed focused ultrasound (pFUS). Human adipose tissue (AD), bone marrow (BM), and umbilical cord (UC) derived MSCs were exposed to pFUS at two intensities: 0.45 W/cm2 ISATA (310 kPa PNP) and 1.3 W/cm2 ISATA (540 kPa PNP). Following pFUS, the viability and proliferation of MSCs were assessed using a hemocytometer and confocal microscopy, and their secreted cytokine profile determined using a multiplex ELISA. Our findings showed that pFUS can stimulate the production of immunomodulatory, anti-inflammatory, and angiogenic cytokines from MSCs which was dependent on both the source of MSC being studied and the acoustic intensity employed. These important findings set the foundation for additional mechanistic and validation studies using this novel noninvasive and clinically translatable technology for modulating MSC biology.


Asunto(s)
Células de la Médula Ósea/citología , Trasplante de Células Madre Mesenquimatosas/métodos , Células Madre Mesenquimatosas/citología , Ensayo de Inmunoadsorción Enzimática , Humanos , Microscopía Confocal
10.
Stem Cell Res Ther ; 11(1): 405, 2020 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-32948247

RESUMEN

BACKGROUND: The aim of this study was to examine the effect of a three-step approach that utilizes the application of adipose tissue-derived mesenchymal stem cells (AD-MSCs), encapsulation, and pulsed focused ultrasound (pFUS) to help the engraftment and function of transplanted islets. METHODS: In step 1, islets were co-cultured with AD-MSCs to form a coating of AD-MSCs on islets: here, AD-MSCs had a cytoprotective effect on islets; in step 2, islets coated with AD-MSCs were conformally encapsulated in a thin layer of alginate using a co-axial air-flow method: here, the capsule enabled AD-MSCs to be in close proximity to islets; in step 3, encapsulated islets coated with AD-MSCs were treated with pFUS: here, pFUS enhanced the secretion of insulin from islets as well as stimulated the cytoprotective effect of AD-MSCs. RESULTS: Our approach was shown to prevent islet death and preserve islet functionality in vitro. When 175 syngeneic encapsulated islets coated with AD-MSCs were transplanted beneath the kidney capsule of diabetic mice, and then followed every 3 days with pFUS treatment until day 12 post-transplantation, we saw a significant improvement in islet function with diabetic animals re-establishing glycemic control over the course of our study (i.e., 30 days). In addition, our approach was able to enhance islet engraftment by facilitating their revascularization and reducing inflammation. CONCLUSIONS: This study demonstrates that our clinically translatable three-step approach is able to improve the function and viability of transplanted islets.


Asunto(s)
Diabetes Mellitus Experimental , Trasplante de Islotes Pancreáticos , Islotes Pancreáticos , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Animales , Diabetes Mellitus Experimental/terapia , Ratones
11.
Ultrasound Med Biol ; 46(5): 1224-1234, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32081583

RESUMEN

Surgery to treat drug-resistant epilepsy can be quite effective but remains substantially underutilized. A pilot study was undertaken to test the feasibility of using a non-invasive, non-ablative, approach to produce focal neuronal loss to treat seizures in a rodent model of temporal lobe epilepsy. In this study, spontaneous, recurrent seizures were established in a mouse model of pilocarpine-induced status epilepticus. After post-status epilepticus stabilization, baseline behavioral seizures were monitored for 30 d. Non-invasive opening of the blood-brain barrier targeting the hippocampus was then produced by using magnetic resonance-guided, low-intensity focused ultrasound, through which a neurotoxin (quinolinic acid) administered intraperitoneally gained access to the brain parenchyma to produce focal neuronal loss. Behavioral seizures were then monitored for 30 d after this procedure, and brains were subsequently prepared for histologic analysis of the sites of neuronal loss. The average frequency of behavioral seizures in all animals (n = 11) was reduced by 21.2%. Histologic analyses along the longitudinal axis of the hippocampus revealed that most of the animals (n = 8) exhibited neuronal loss located primarily in the intermediate aspect of the hippocampus, while sparing the septal aspect. Two other animals with damage to the intermediate hippocampus also exhibited prominent bilateral damage to the septal aspect of the hippocampus. A final animal had negligible neuronal loss overall. Notably, the site of neuronal loss along the longitudinal axis of the hippocampus influenced seizure outcomes. Animals that did not have bilateral damage to the septal hippocampus displayed a mean decrease in seizure frequency of 27.7%, while those with bilateral damage to the septal hippocampus actually increased seizure frequency by 18.7%. The animal without neuronal loss exhibited an increase in seizure frequency of 19.6%. The findings indicate an overall decrease in seizure frequency in treated animals. And, the site of neuronal loss along the longitudinal axis of the hippocampus appears to play a key role in reducing seizure activity. These pilot data are promising, and they encourage additional and more comprehensive studies examining the effects of targeted, non-invasive, neuronal lesions for the treatment of epilepsy.


Asunto(s)
Epilepsia del Lóbulo Temporal/cirugía , Procedimientos Quirúrgicos Ultrasónicos , Animales , Barrera Hematoencefálica , Modelos Animales de Enfermedad , Epilepsia del Lóbulo Temporal/inducido químicamente , Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Epilepsia del Lóbulo Temporal/patología , Estudios de Factibilidad , Imagen por Resonancia Magnética , Masculino , Ratones , Microburbujas , Neuronas/patología , Pilocarpina , Proyectos Piloto
12.
Artículo en Inglés | MEDLINE | ID: mdl-31545716

RESUMEN

Intravascular acoustic radiation force impulse (IV-ARFI) imaging has the potential to identify vulnerable atherosclerotic plaques and improve clinical treatment decisions and outcomes for patients with coronary heart disease. Our long-term goal is to develop a thin, flexible catheter probe that does not require mechanical rotation to achieve high-resolution IV-ARFI imaging. In this work, we propose a novel cylindrical transducer array design for IV-ARFI imaging and investigate the feasibility of this approach. We present the construction of a 2.2-mm-long, 4.6-Fr cylindrical prototype transducer to demonstrate generating large ARFI displacements from a small toroidal beam, and we also present simulations of the proposed IV-ARFI cylindrical array design using Field II and a cylindrical finite-element model of vascular tissues and soft plaques. The prototype transducer was found to generate peak radial displacements of over [Formula: see text] in soft gelatin phantoms, and simulations demonstrate the ability of the array design to obtain ARFI images and distinguish soft plaque targets from surrounding, stiffer vessel wall tissue. These results suggest that high-resolution IV-ARFI imaging is possible using a cylindrical transducer array.


Asunto(s)
Catéteres , Diagnóstico por Imagen de Elasticidad/instrumentación , Transductores , Diseño de Equipo , Estudios de Factibilidad , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen , Placa Aterosclerótica/diagnóstico por imagen , Ultrasonografía Intervencional/instrumentación
13.
Adv Ther (Weinh) ; 3(12)2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33415184

RESUMEN

Spatially localized microbubble cavitation by ultrasound offers an effective means of altering permeability of natural barriers (i.e. blood vessel and cell membrane) in favor of nanomaterials accumulation in the target site. In this study, a clinically relevant, minimally invasive ultrasound guided therapeutic approach is investigated for targeted delivery of anticancer microRNA loaded PLGA-b-PEG nanoparticles to spontaneous hepatocellular neoplasia in a canine model. Quantitative assessment of the delivered microRNAs revealed prominent and consistent increase in miRNAs levels (1.5-to 2.3-fold increase (p<0.001)) in ultrasound treated tumor regions compared to untreated control regions. Immunohistology of ultrasound treated tumor tissue presented a clear evidence for higher amount of nanoparticles extravasation from the blood vessels. A distinct pattern of cytokine expression supporting CD8+ T cells mediated "cold-to-hot" tumor transition was evident in all patients. On the outset, proposed platform can enhance delivery of miRNA-loaded nanoparticles to deep seated tumors in large animals to enhance chemotherapy.

14.
Ultrasound Med Biol ; 46(3): 630-638, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31882169

RESUMEN

Pulsed focused ultrasound (pFUS) utilizes short cycles of sound waves to mechanically shake cells within tissues which, in turn, causes transient local increases in cytokines, growth factors and cell adhesion molecules. Although the effect of pFUS has been investigated in several different organs including the kidney, muscle and heart, its effect on the pancreas has not been investigated. In the present work, we applied pFUS to the rodent pancreas with the following parameters: 1.1-MHz frequency, 5-Hz pulse repetition frequency, 5% duty cycle, 10-ms pulse length, 160-s duration. Low-intensity pFUS had a spatial average temporal average intensity of 11.5 W/cm2 and a negative peak pressure of 3 MPa; high-intensity pFUS had a spatial average temporal average intensity of 18.5 W/cm2 and negative peak pressure of 4 MPa. Here we found that pFUS changed the expression of several cytokines while having no effect on the underlying tissue histology or health of pancreatic cells (as reflected by no significant change in plasma levels of amylase and lipase). Furthermore, we found that this effect on cytokine expression in the pancreas was acoustic intensity dependent; while pFUS at low intensities turned off the expression of several cytokines, at high intensities it had the opposite effect and turned on the expression of these cytokines. The ability to non-invasively manipulate the microenvironment of the pancreas using sound waves could have profound implications for priming and modulating this organ for the application of cellular therapies in the context of both regenerative medicine (i.e., diabetes and pancreatitis) and oncology (i.e., pancreatic cancer).


Asunto(s)
Páncreas/efectos de la radiación , Ondas Ultrasónicas , Animales , Femenino , Ratones , Páncreas/patología
15.
Sci Rep ; 9(1): 13416, 2019 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-31527773

RESUMEN

This study demonstrates that pulsed focused ultrasound (pFUS) therapy can non-invasively enhance the function and engraftment of pancreatic islets following transplantation. In vitro, we show that islets treated with pFUS at low (peak negative pressure (PNP): 106kPa, spatial peak temporal peak intensity (Isptp): 0.71 W/cm2), medium (PNP: 150kPa, Isptp: 1.43 W/cm2) or high (PNP: 212kPa, Isptp: 2.86 W/cm2) acoustic intensities were stimulated resulting in an increase in their function (i.e. insulin secretion at low-intensity: 1.15 ± 0.17, medium-intensity: 2.02 ± 0.25, and high-intensity: 2.54 ± 0.38 fold increase when compared to control untreated islets; P < 0.05). Furthermore, we have shown that this improvement in islet function is a result of pFUS increasing the intracellular concentration of calcium (Ca2+) within islets which was also linked to pFUS increasing the resting membrane potential (Vm) of islets. Following syngeneic renal sub-capsule islet transplantation in C57/B6 mice, pFUS (PNP: 2.9 MPa, Isptp: 895 W/cm2) improved the function of transplanted islets with diabetic animals rapidly re-establishing glycemic control. In addition, pFUS was able to enhance the engraftment by facilitating islet revascularization and reducing inflammation. Given a significant number of islets are lost immediately following transplantation, pFUS has the potential to be used in humans as a novel non-invasive therapy to facilitate islet function and engraftment, thereby improving the outcome of diabetic patients undergoing islet transplantation.


Asunto(s)
Diabetes Mellitus Experimental/terapia , Supervivencia de Injerto , Trasplante de Islotes Pancreáticos/métodos , Islotes Pancreáticos/fisiología , Ultrasonografía/métodos , Animales , Glucemia/metabolismo , Secreción de Insulina , Islotes Pancreáticos/efectos de la radiación , Masculino , Ratones , Ratones Endogámicos C57BL
16.
J Control Release ; 309: 1-10, 2019 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-31326463

RESUMEN

In this study, we designed and validated a platform for ultrasound and microbubble-mediated delivery of FDA-approved pegylated poly lactic-co-glycolic acid (PLGA) nanoparticles loaded with anticancer microRNAs (miRNAs) to deep tissues in a pig model. Small RNAs have been shown to reprogram tumor cells and sensitize them to clinically used chemotherapy. To overcome their short intravascular circulation half-life and achieve controlled and sustained release into tumor cells, anticancer miRNAs need to be encapsulated into nanocarriers. Focused ultrasound combined with gas-filled microbubbles provides a noninvasive way to improve the permeability of tumor vasculature and increase the delivery efficiency of drug-loaded particles. A single handheld, curvilinear ultrasound array was used in this study for image-guided therapy with clinical-grade SonoVue contrast agent. First, we validated the platform on phantoms to optimize the microbubble cavitation dose based on acoustic parameters, including peak negative pressure, pulse length, and pulse repetition frequency. We then tested the system in vivo by delivering PLGA nanoparticles co-loaded with antisense-miRNA-21 and antisense-miRNA-10b to pig liver and kidney. Enhanced miRNA delivery was observed (1.9- to 3.7-fold increase) as a result of the ultrasound treatment compared to untreated control regions. Additionally, we used highly fluorescent semiconducting polymer nanoparticles to visually assess nanoparticle extravasation. Fluorescent microscopy suggested the presence of nanoparticles in the extravascular compartment. Hematoxylin and eosin staining of treated tissues did not reveal tissue damage. The results presented in this manuscript suggest that the proposed platform may be used to safely and noninvasively enhance the delivery of miRNA-loaded nanoparticles to target regions in deep organs in large animal models.


Asunto(s)
Sistemas de Liberación de Medicamentos/instrumentación , Nanopartículas/química , Neoplasias/terapia , Copolímero de Ácido Poliláctico-Ácido Poliglicólico/química , ARN sin Sentido/administración & dosificación , Animales , Sistemas de Liberación de Medicamentos/métodos , Femenino , Terapia Genética , MicroARNs/genética , Microburbujas , Neoplasias/genética , ARN sin Sentido/genética , ARN sin Sentido/farmacocinética , Porcinos , Terapia por Ultrasonido/instrumentación , Terapia por Ultrasonido/métodos
SELECCIÓN DE REFERENCIAS