Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Pers Med ; 14(6)2024 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-38929839

RESUMEN

INTRODUCTION: Obstructive sleep apnea (OSA) is associated with an increased risk of hypertension, coronary artery disease, heart failure (HF), and atrial fibrillation (AF). MATERIALS AND METHODS: A total of 179 patients aged 34-81 years were included in the study. The median age was 63 years (interquartile range: 56-69 years). Of these patients, 105 (58.7%) were men, and 74 (41.3%) were women; there were cases of paroxysmal (n = 99), persistent (n = 64), and permanent AF (n = 16). All patients underwent investigations including respiratory sleep monitoring, echocardiography, and 24 h Holter electrocardiography monitoring. Statistical analyses were performed using IBM SPSS Statistics 26.0. RESULTS: OSA was detected in 131 (73.2%) patients. In patients with OSA, paroxysmal AF was commonest (n = 65), followed by persistent AF (n = 51) and permanent AF (n = 15). The patients with sleep apnea had increased body mass index (33.6 kg/m2; p = 0.02), waist circumference (114 cm; p < 0.001), and neck circumference (42 cm; p < 0.001) values. HF (OR 2.9; 95% CI: 1.4-5.9; p = 0.004) and type 2 diabetes (OR 3.6; 95% CI: 1.5-8.3; p = 0.001) were more common in patients with AF and OSA. The STOP-BANG scale (AUC = 0.706 ± 0.044; 95% CI: 0.619-0.792; p < 0.001) and the Berlin questionnaire (AUC = 0.699 ± 0.044; 95% CI: 0.614-0.785) had a higher predictive ability for identifying sleep apnea. CONCLUSIONS: Patients with AF demonstrate a high prevalence of OSA and an increased association with cardiovascular comorbidities. The STOP-BANG scale and the Berlin questionnaire can be used to screen for OSA in patients with AF.

2.
Tex Heart Inst J ; 49(5)2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36223224

RESUMEN

This report describes our experience with a 5-year-old girl who had an extremely rare presentation of a right atrial aneurysm and associated Wolff-Parkinson-White syndrome. Before being referred to our department, she underwent an ineffective radiofrequency ablation for repeated episodes of paroxysmal supraventricular tachycardia that were causing dizziness, palpitations, and chest discomfort. We resected the aneurysm with good results; she was doing well and was in normal sinus rhythm at the time of her 1-year follow-up visit.


Asunto(s)
Apéndice Atrial , Ablación por Catéter , Aneurisma Cardíaco , Síndrome de Wolff-Parkinson-White , Apéndice Atrial/cirugía , Preescolar , Femenino , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/diagnóstico por imagen , Atrios Cardíacos , Humanos , Síndrome de Wolff-Parkinson-White/complicaciones , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirugía
3.
Ann Pediatr Cardiol ; 14(1): 67-71, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33679063

RESUMEN

BACKGROUND: The pacemaker lead placement is presented as one of the most appropriate procedures in children with a complete atrioventricular block (AVB). Despite the fact that video-assisted thoracic surgery (VATS) for epicardial lead placement has demonstrated positive results as to the feasibility, safety, and efficacy in adults, its role in pacemaker implantation in children remains unclear. AIM: This study sought to assess the intermediate-term outcomes of video-assisted thoracoscopic pacemaker lead placement in children with complete AVB. MATERIALS AND METHODS: From May 2017 to November 2019, five children with complete AVB underwent minimally invasive left ventricular (LV) lead placements via thoracoscopic video assistance approach. The procedure was performed under complex intratracheal anesthesia with single-lung ventilation, all pacing parameters were evaluated in perioperative and follow-up periods. RESULTS: The median age of children at implantation was 3 years (range: 2 to 4 years), the median weight was 13 kg (range: 12-15 kg). All procedures were completed successfully, pacing thresholds for the active lead measured 0.3-1.1V, with R-wave amplitude of 8-18 mV and impedance of 560-1478 Ohm. CONCLUSION: Thoracoscopic pacemaker lead placement may provide a potential alternative to the transthoracic approach of epicardial lead placement in children with AVB.

4.
Biomed Res Int ; 2015: 591603, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26640789

RESUMEN

PURPOSE: The results of cryoballoon ablation (CBA) procedure have been mainly derived from studies conducted in experienced atrial fibrillation (AF) ablation centres. Here, we report on CBA efficacy and complications resulting from real practice of this procedure at both high- and low-volume centres. METHODS: Among 62 Russian centres performing AF ablation, 15 (24%) used CBA technology for pulmonary vein isolation. The centres were asked to provide a detailed description of all CBA procedures performed and complications, if encountered. RESULTS: Thirteen sites completed interviews on all CBAs in their centres (>95% of CBAs in Russia). Six sites were high-volume AF ablation (>100 AF cases/year) centres, and 7 were low-volume AF ablation. There was no statistical difference in arrhythmia-free rates between high- and low-volume centres (64.6 versus 60.8% at 6 months). Major complications developed in 1.5% of patients and were equally distributed between high- and low-volume centres. Minor procedure-related events were encountered in 8% of patients and were more prevalent in high-volume centres. Total event and vascular access site event rates were higher in women than in men. CONCLUSIONS: CBA has an acceptable efficacy profile in real practice. In less experienced AF ablation centres, the major complication rate is equal to that in high-volume centres.


Asunto(s)
Fibrilación Atrial/terapia , Instituciones Cardiológicas/estadística & datos numéricos , Ablación por Catéter/efectos adversos , Ablación por Catéter/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Complicaciones Posoperatorias , Federación de Rusia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...