Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Med Phys ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39012800

RESUMEN

BACKGROUND: Delivery variations during radiotherapy can cause discrepancies between planned and delivered dose distribution. These variations could arise from random and systematic offsets in certain machine parameters or systematic offsets related to the calibration process of the treatment unit. PURPOSE: The aim of this study was to present a novel simulation-based methodology to evaluate realistic delivery variations in three dimensions (3D). Additionally, we investigated the dosimetric impact of delivery variations for volumetric modulated arc therapy (VMAT) plans for different treatment sites and complexities. METHODS: Twelve VMAT plans for different treatment sites (prostate-, head & neck-, lung-, and gynecological cancer) were selected. The clinical plan used for the treatment of each patient was reoptimized to create one plan with reduced complexity (i.e., simple plan) and one of higher complexity (i.e., complex plan). This resulted in a total of 36 plans. Delivery variations were simulated by randomly introducing offsets in multi-leaf collimator position, jaw position, gantry angle and collimator angle simultaneously. Twenty simulations were carried out for each of the 36 plans, yielding 720 simulated deliveries. To explore the impact of individual offsets, additional simulations were conducted for each type of offset separately. A 3D dose calculation was performed for each simulation using the same calculation engine as for the clinical plan. Two standard deviations (2SD) of dose were determined for every voxel for 3D-spatial evaluations. The dose variation in certain DVH metrics, that is, D2% and D98% for the clinical target volume and five different DVH metrics for selected organs at risk, was calculated for the twenty simulated deliveries of each plan. For comparison, the effect of delivery variations was assessed by conducting measurements with the Delta4 phantom. RESULTS: The volume of voxels with 2SD above 1% of the prescribed dose was consistently larger for the complex plans in comparison to their corresponding simple and clinical plans. 2SDs larger than 1% were in many cases, found to accumulate outside the planning target volume. For complex plans, regions with 2SDs larger than 1% were detected also inside the high dose region, exhibiting, on average, a size six times larger volume, than those observed in simple plans. Similar results were found for all treatment sites. Variation in the selected DVH metrics for the simulated deliveries was generally largest for the complex plans with few exceptions. When comparing the 2SD distribution of the measurements with the 2SD distribution from the simulations, the spatial information showed deviations outside the PTV in both simulations and measurements. However, the measured values were, on average, 35% higher for the prostate plans and 10% higher for the head & neck plans compared to the simulated values. CONCLUSIONS: The presented methodology effectively quantified and localized dose deviations due to delivery offsets. The 3D analysis provided information that was undetectable using the analysis based on DVH metrics. Dosimetric uncertainties due to delivery variations were prominent at the edge of the high-dose region irrespective of treatment site and plan complexity. Dosimetric uncertainties inside the high-dose region was more profound for plans of higher complexity.

2.
Radiother Oncol ; 180: 109484, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36690303

RESUMEN

BACKGROUND AND PURPOSE: In cancer treatment precise definition of the tumor volume is essential, but despite development in imaging modalities, this remains a challenge. Here, pathological tumor volumes from the surgical specimens were obtained and compared to tumor volumes defined from modern PET/MRI hybrid imaging. The purpose is to evaluate mismatch between the volumes defined from imaging and pathology was estimated and potential clinical impact. METHODS AND MATERIALS: Twenty-five patients with head and neck squamous cell carcinoma were scanned on an integrated PET/MRI system prior to surgery. Three gross tumor volumes (GTVs) from the primary tumor site were delineated defined from MRI (GTVMRI), PET (GTVPET) and one by utilizing both anatomical images and clinical information (GTVONCO). Twenty-five primary tumor specimens were extracted en bloc, scanned with PET/MRI and co-registered to the patient images. Each specimen was sectioned in blocks, sliced and stained with haematoxylin and eosin. All slices were digitalized and tumor delineated by a head and neck pathologist. The pathological tumor areas in all slices were interpolated yielding a pathological 3D tumor volume (GTVPATO). GTVPATOwas compared with the imaging GTV's and potential mismatch was estimated. RESULTS: Thirteen patients were included. The mean volume of GTVONCOwas larger than the GTV's defined from PET or MRI. The mean mismatch of the GTVPATOcompared to the GTVPET, GTVMRIand GTVONCOwas 31.9 %, 54.5 % and 27.9 % respectively, and the entire GTVPATO was only fully encompassed in GTVONCO in 1 of 13 patients. However, after the addition of a clinical 5 mm margin the GTVPATO was fully encompassed in GTVONCO in 11 out of 13 patients. CONCLUSIONS: Despite modern hybrid imaging modalities, a mismatch between imaging and pathological defined tumor volumes was observed in all patients.A 5 mm clinical margin was sufficient to ensure inclusion of the entire pathological volume in 11 out of 13 patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Tomografía Computarizada por Rayos X , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carga Tumoral , Tomografía Computarizada por Rayos X/métodos , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Radiofármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...