1.
Invest Radiol ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747489

RESUMEN

PURPOSE: Intraoral coils (IOCs) in magnetic resonance imaging (MRI) significantly improve the signal-to-noise ratio compared with conventional extraoral coils. To assess the safety of IOCs, we propose a 2-step procedure to evaluate radiofrequency-induced heating of IOCs and compare maximum temperature increases in 3 different types of IOCs. METHODS: The 2-step safety assessment consists of electric field measurements and simulations to identify local hotspots followed by temperature measurements during MRI. With this method, 3 different coil types (inductively coupled IFC, transmit/receive tLoop, and receive-only tLoopRx) were tested at 1.5 T and 3 T for both tuned and detuned coil states. High SAR and regular MRI protocols were applied for 2 coil positions. RESULTS: The measured E field maps display distinct hotspots for all tuned IOCs, which were reduced by at least 40-fold when the IOCs were detuned. Maximum temperature rise was higher when the coils were positioned at the periphery of the phantom with the coil planes parallel to B0. When neither active nor passive detuning was applied, maximum temperature increase of ΔT = 1.3/0.5/1.8 K was found for IFC/tLoop/tLoopRx coils. Hotspots detected by E field measurements, and simulations were consistent. In the simulations, the results were different for homogeneous phantoms compared with full anatomical models. The 2-step test procedure is applicable to different coil types. CONCLUSIONS: The results indicate that a risk for radiofrequency-induced heating exists for tuned IOCs, so that adequate detuning circuits need to be integrated in the coils to ensure safe operation.

2.
Invest Radiol ; 57(3): 163-170, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34510099

RESUMEN

OBJECTIVES: Accurate visualization of dental root canals is vital for the correct diagnosis and subsequent treatment. This work assesses the improvement of a dedicated new coil for dental magnetic resonance imaging (MRI) in comparison to conventional ones in terms of signal-to-noise ratio (SNR) and visibility. MATERIALS AND METHODS: A newly developed intraoral flexible coil was used to display dental roots with MRI, and it provides improved sensitivity with a loop design and size adjusted to a single tooth anatomy. Ex vivo and in vivo measurements were performed on a 3 T clinical MR system, and results were compared with conventional head and surface coil images. Additional comparison was performed with a modified fast spin echo sequence and a constructive interference in steady-state sequence. RESULTS: Ex vivo, an SNR gain of 6.3 could be achieved with the intraoral flexible coil setup, and higher visibility down to 200 µm was possible, whereas the external loop coil is limited to 400 µm. In vivo measurements in a volunteer resulted in an SNR gain of up to 4.5 with an improved delineation of the root canals, especially for the branch tissue splitting of the mesial root canal into mesial-buccal and mesial-lingual. CONCLUSIONS: In summary, we showed the feasibility of implementing a wireless coil approach with readily available dental practice materials for sealing and placement. Highly improved MRI scans can be acquired within clinically feasible scan times, and this might provide additional medical findings to supplement available x-ray images.


Asunto(s)
Cavidad Pulpar , Imagen por Resonancia Magnética , Cavidad Pulpar/diagnóstico por imagen , Diseño de Equipo , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Relación Señal-Ruido
3.
J Magn Reson ; 319: 106825, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32947127

RESUMEN

In Magnetic Resonance Imaging (MRI), radio frequency (RF) coils of different forms and shapes are used to maximize signal-to-noise ratio (SNR). RF coils are designed for clinical applications and have dimensions comparable with the target body part to be imaged, and they perform best when loaded by human tissue majority of which have conductivity values higher than 0.5 S/m. However, they are not properly tuned and matched for samples having low conductivity such as solid samples with low water content. Moreover, for samples with low filling factor and low conductivity, the noise in MRI is dominated by RF coil losses. In this case, RF coil design can be optimized to improve image SNR. Here, a new software tool (Multi-parameter Analytical Method for B1 and SNR Analysis) MAMBA is presented to design and compare volume coils of birdcage, solenoid, and loop-gap design for these samples. The input parameters of the tool are the sample properties, the coil design and the hardware properties, of which a relative SNR is determined. For that, a figure of merit is calculated from the coil sensitivity, applied resonant frequency and the resistive losses of sample, coil and capacitive components. The tool was tested in an ancient Egyptian mummy head which represents an extreme case of MRI with short T2*. Two optimized birdcage coils were designed using MAMBA, constructed and compared to a commercial transmit receive head coil. Calculated relative SNR values are in good agreement with the measurements.