Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38856953

RESUMEN

AIMS: Impaired vision is an additional risk factor in elderly for falls. We investigated the hypothesis that treadmill (TM) walking affects visual function in both healthy elderly and those with early-moderate visual dysfunction due to glaucoma. METHODS: Thirty healthy controls (HC) aged 64-83 years and 18 glaucoma patients (GLA) aged 62-82 years participated in this cross-sectional study. The impact of TM-walking on visual function was assessed binocularly for (i) best-corrected visual acuity (BCVA) with and without crowding effect, (ii) contrast sensitivity (CS), and (iii) and visual field (mean deviation, VF-MD). Visual function was tested while participants were standing or during TM-walking for 2 speed conditions: (i) fast walking at their preferred speed and (ii) walking at a fixed speed of 3.5 km/h. RESULTS: GLA, most with early-moderate VF loss, performed equally well as HC. Independent of GROUP, an impact of SPEED on visual functions was statistically evident with large statistical effect size for (i) both types of BCVA with a mean loss of 0.02-0.05 logMAR (η2 = 0.41) and (ii) VF-MD with mean loss of 1 dB (η2 = 0.70), but not for CS. CONCLUSIONS: Here, we introduce a paradigm for the assessment of visual function during walking. We provide proof-of-concept that our approach allows for the identification of walking induced visual function loss, i.e., a deterioration of BCVA and VF-sensitivity during TM-walking in both groups. It is therefore of promise for the investigation of the relation of vision impairment and mobility, ultimately the increased frequency of falls in advanced glaucoma.

2.
Br J Ophthalmol ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38408856

RESUMEN

BACKGROUND: Intraocular pressure (IOP) monitoring in glaucoma management is evolving with novel devices. We investigated the reproducibility of 24 hour profiles on two consecutive days and after 30 days of self-measurements via telemetric IOP monitoring. METHODS: Seven primary patients with open-angle glaucoma previously implanted with a telemetric IOP sensor in one eye underwent automatic measurements throughout 24 hours on two consecutive days ('day 1' and 'day 2'). Patients wore an antenna adjacent to the study eye connected to a reader device to record IOP every 5 min. Also, self-measurements in six of seven patients were collected for a period of 30 days. Analysis included calculation of hourly averages to correlate time-pairs of day 1 versus day 2 and the self-measurements vers day 2. RESULTS: The number of IOP measurements per patient ranged between 151 and 268 on day 1, 175 and 268 on day 2 and 19 and 1236 during 30 days of self-measurements. IOP time-pairs of automatic measurements on day 1 and day 2 were significantly correlated at the group level (R=0.83, p<0.001) and in four individual patients (1, 2, 6 and 7). IOP time-pairs of self-measurements and day 2 were significantly correlated at the group level (R=0.4, p<0.001) and in four individual patients (2, 5, 6 and 7). CONCLUSIONS: Twenty-four hour automatic measurements of IOP are correlated on consecutive days and, though to a lesser degree, with self-measurements. Therefore a virtual 24-hour IOP curve might be constructed from self-measurements. Both options provide an alternative to frequent in-office IOP measurements.

3.
Transl Vis Sci Technol ; 12(11): 31, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-38015169

RESUMEN

Purpose: To investigate gait kinematics during single- and dual-task walking in glaucoma patients compared with healthy controls. Methods: Nineteen glaucoma patients (10 females, 9 males) and 30 healthy controls (17 females, 13 males) participated in this cross-sectional study. Spatiotemporal gait parameters (e.g., stride length, velocity, minimum toe clearance [MTC]) were assessed using inertial measurement units (sampling frequency 100 Hz) during single-task walking and dual-task walking at a comfortable velocity. During dual-task walking, participants walked and concurrently performed different cognitive tasks in a random order: (i) reaction time task, (ii) N-Back-task, and (iii) letter fluency task with two difficulty levels, respectively. Repeated measures analyses of covariance (Group × Condition) were conducted to analyze the data. Results: A significant effect of group was found for the coefficient of variation (CoV) of the MTC, F(1,39) = 4.504, P = 0.040, \({\rm{\eta }}_{\rm{p}}^2\) = 0.104, with higher values in glaucoma patients. Based on the effect sizes, a main effect of group was also found for the MTC, F(1,39) = 2.668, P = 0.110, \({\rm{\eta }}_{\rm{p}}^2\) = 0.064, and the MTCCoV dual-task costs, F(1,38) = 3.225, P = 0.08, \({\rm{\eta }}_{\rm{p}}^2\) = 0.078, which was lower and higher, respectively, in glaucoma patients. Conclusions: The present study revealed a significantly higher MTC variability as well as medium effect sizes for a lower MTC and higher MTC dual-task costs in glaucoma patients compared with healthy controls, which might be related to a higher risk of falling owing to tripping. Translational Relevance: The minimum toe clearance might mirror disease-related changes in walking performance and might have prognostic value for assessing fall risk in glaucoma patients.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Femenino , Masculino , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Estudios Transversales , Marcha , Glaucoma/diagnóstico
4.
Front Integr Neurosci ; 17: 1158148, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37138797

RESUMEN

Introduction: The retina, a window into the brain, allows for the investigation of many disease-associated inflammatory and neurodegenerative changes affecting the central nervous system (CNS). Multiple sclerosis (MS), an autoimmune disease targeting the CNS, typically impacts on the visual system including the retina. Hence, we aimed to establish innovative functional retinal measures of MS-related damage, e.g., spatially resolved non-invasive retinal electrophysiology, backed by established morphological retinal imaging markers, i.e., optical coherence tomography (OCT). Methods: 20 healthy controls (HC) and 37 people with MS [17 without history of optic neuritis (NON) and 20 with (HON) history of optic neuritis] were included. In this work, we differentially assessed photoreceptor/bipolar cells (distal retina) and retinal ganglion cell (RGC, proximal retina) function besides structural assessment (OCT). We compared two multifocal electroretinography-based approaches, i.e., the multifocal pattern electroretinogram (mfPERG) and the multifocal electroretinogram to record photopic negative response (mfERG PhNR ). Structural assessment utilized peripapillary retinal nerve fiber layer thickness (pRNFL) and macular scans to calculate outer nuclear thickness (ONL) and macular ganglion cell inner plexiform layer thickness (GCIPL). One eye was randomly selected per subject. Results: In NON, photoreceptor/bipolar cell layer had dysfunctional responses evidenced by reduced mfERG PhNR -N1 peak time of the summed response, but preserved structural integrity. Further, both NON and HON demonstrated abnormal RGC responses as evidenced by the photopic negative response of mfERG PhNR (mfPhNR) and mfPERG indices (P < 0.05). Structurally, only HON had thinned retina at the level of RGCs in the macula (GCIPL, P < 0.01) and the peripapillary area (pRNFL, P < 0.01). All three modalities showed good performance to differentiate MS-related damage from HC, 71-81% area under curve. Conclusion: In conclusion, while structural damage was evident mainly for HON, functional measures were the only retinal read-outs of MS-related retinal damage that were independent of optic neuritis, observed for NON. These results indicate retinal MS-related inflammatory processes in the retina prior to optic neuritis. They highlight the importance of retinal electrophysiology in MS diagnostics and its potential as a sensitive biomarker for follow-up in innovative interventions.

5.
Br J Ophthalmol ; 107(10): 1425-1431, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35701079

RESUMEN

BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests. RESULTS: For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking. CONCLUSION: Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Presión Intraocular , Glaucoma de Ángulo Abierto/diagnóstico , Tonometría Ocular , Glaucoma/diagnóstico , Párpados , Músculos Oculomotores
6.
J Clin Med ; 11(8)2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35456248

RESUMEN

One of the most important functions of the retina-the enabling of perception of fast movements-is largely suppressed in standard automated perimetry (SAP) and kinetic perimetry (Goldmann) due to slow motion and low contrast between test points and environment. Rapid campimetry integrates fast motion (=10°/4.7 s at 40 cm patient-monitor distance) and high contrast into the visual field (VF) examination in order to facilitate the detection of absolute scotomas. A bright test point moves on a dark background through the central 10° VF. Depending on the distance to the fixation point, the test point automatically changes diameter (≈0.16° to ≈0.39°). This method was compared to SAP (10-2 program) for six subjects with glaucoma. Rapid campimetry proved to be comparable and possibly better than 10-2 SAP in identifying macular arcuate scotomas. In four subjects, rapid campimetry detected a narrow arcuate absolute scotoma corresponding to the nerve fiber course, which was not identified as such with SAP. Rapid campimetry promises a fast screening method for the detection of absolute scotomas in the central 10° visual field, with a potential for cloud technologies and telemedical applications. Our proof-of-concept study motivates systematic testing of this novel method in a larger cohort.

7.
Drugs ; 81(17): 2017-2033, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34724172

RESUMEN

OBJECTIVE: To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). METHODS: This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG or OHT and an open iridocorneal angle inferiorly in the study eye. Study eyes were administered 10 or 15 µg bimatoprost implant on day 1, week 16, and week 32, or twice-daily topical timolol maleate 0.5%. Primary endpoints were IOP and IOP change from baseline through week 12. Safety measures included treatment-emergent adverse events (TEAEs) and corneal endothelial cell density (CECD). RESULTS: Both 10 and 15 µg bimatoprost implant met the primary endpoint of noninferiority to timolol in IOP lowering through 12 weeks. Mean IOP reductions from baseline ranged from 6.2-7.4, 6.5-7.8, and 6.1-6.7 mmHg through week 12 in the 10 µg implant, 15 µg implant, and timolol groups, respectively. IOP lowering was similar after the second and third implant administrations. Probabilities of requiring no IOP-lowering treatment for 1 year after the third administration were 77.5% (10 µg implant) and 79.0% (15 µg implant). The most common TEAE was conjunctival hyperemia, typically temporally associated with the administration procedure. Corneal TEAEs of interest (primarily corneal endothelial cell loss, corneal edema, and corneal touch) were more frequent with the 15 than the 10 µg implant and generally were reported after repeated administrations. Loss in mean CECD from baseline to month 20 was ~ 5% in 10 µg implant-treated eyes and ~ 1% in topical timolol-treated eyes. Visual field progression (change in the mean deviation from baseline) was reduced in the 10 µg implant group compared with the timolol group. CONCLUSIONS: The results corroborated the previous phase 3 study of the bimatoprost implant. The bimatoprost implant met the primary endpoint and effectively lowered IOP. The majority of patients required no additional treatment for 12 months after the third administration. The benefit-risk assessment favored the 10 over the 15 µg implant. Studies evaluating other administration regimens with reduced risk of corneal events are ongoing. The bimatoprost implant has the potential to improve adherence and reduce treatment burden in glaucoma. CLINICALTRIALS. GOV IDENTIFIER: NCT02250651.


Asunto(s)
Antihipertensivos/uso terapéutico , Bimatoprost/uso terapéutico , Implantes de Medicamentos/uso terapéutico , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Hipertensión Ocular/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Antihipertensivos/administración & dosificación , Antihipertensivos/efectos adversos , Bimatoprost/administración & dosificación , Bimatoprost/efectos adversos , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Implantes de Medicamentos/administración & dosificación , Implantes de Medicamentos/efectos adversos , Femenino , Humanos , Presión Intraocular/efectos de los fármacos , Masculino , Persona de Mediana Edad , Soluciones Oftálmicas , Timolol/uso terapéutico , Adulto Joven
8.
Front Neurosci ; 15: 745886, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34566575

RESUMEN

Current initiatives to restore vision emphasize the need for objective assessments of visual field (VF) defects as pursued with functional magnetic resonance imaging (fMRI) approaches. Here, we compared population receptive field (pRF) mapping-based VF reconstructions to an fMRI method that uses more robust visual stimulation (on-off block design) in combination with individualized anatomy-driven retinotopic atlas-information (atlas-based VF). We investigated participants with sizable peripheral VF-deficits due to advanced glaucoma (n = 4) or retinitis pigmentosa (RP; n = 2) and controls (n = 6) with simulated scotoma. We obtained (1) standard automated perimetry (SAP) data as reference VFs and 3T fMRI data for (2) pRF-mapping [8-direction bar stimulus, fixation color change task] and (3) block-design full-field stimulation [8-direction drifting contrast patterns during (a) passive viewing (PV) and (b) one-back-task (OBT; reporting successions of identical motion directions) to probe the impact of previously reported task-related unspecific visual cortex activations]. Correspondence measures between the SAP and fMRI-based VFs were accuracy, assisted by sensitivity and specificity. We found an accuracy of pRF-based VF from V1 in patients [median: 0.62] that was similar to previous reports and increased by adding V2 and V3 to the analysis [0.74]. In comparison to the pRF-based VF, equivalent accuracies were obtained for the atlas-based VF for both PV [0.67] and, unexpectedly, the OBT [0.59], where, however, unspecific cortical activations were reflected by a reduction in sensitivity [0.71 (PV) and 0.35 (OBT)]. In conclusion, in patients with peripheral VF-defects, we demonstrate that previous fMRI procedures to obtain VF-estimates might be enhanced by: (1) pooling V1-V3 to enhance accuracy; (2) reporting sensitivity and specificity measures to increase transparency of the VF-reconstruction metric; (3) applying atlas-based procedures, if pRF-based VFs are not available or difficult to obtain; and (4) giving, counter-intuitively, preference to PV. These findings are expected to provide guidance to overcome current limitations of translating fMRI-based methods to a clinical work-up.

9.
Ophthalmologe ; 118(9): 885-892, 2021 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-34406461

RESUMEN

BACKGROUND: During the coronavirus disease 2019 (COVID-19) pandemic access to and utilization of ophthalmologic healthcare providers was partially restricted. OBJECTIVE: This article provides an overview of already available tele-ophthalmologic applications for better care during the pandemic as well as those still under development. MATERIAL AND METHODS: The study included an analysis of current scientific publications, analysis of unrestricted screening applications in smart device app stores as well as telemetric medical products specifically designed for home monitoring and discussion of the requirements of an integrated ophthalmologic video consultation. RESULTS: There is significant interest in tele-ophthalmologic applications and devices as evidenced by a rise in the number of relevant publications. Freely available screening tests for smart phones and tablets are as a rule currently not validated and show significant discrepancies from established standard tests. Telemetric medical devices show great potential for home monitoring in chronic ophthalmologic diseases but must first become established in the clinical routine. CONCLUSION: There is an unmet need for systematic analysis, development and validation of telemedical applications and medical products for ophthalmology in order to advantageously utilize the potential of telemedicine and to incorporate this into an ophthalmologic video consultation.


Asunto(s)
COVID-19 , Oftalmología , Telemedicina , Humanos , Pandemias , SARS-CoV-2
10.
Front Neurosci ; 15: 653632, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34381327

RESUMEN

In advanced retinitis pigmentosa with retinal lesions, the lesion projection zone (LPZ) in the early visual cortex can be driven during visual tasks, while it remains unresponsive during passive viewing. We tested whether this finding translates to advanced glaucoma, a major cause of acquired blindness. During visual stimulation, 3T fMRI scans were acquired for participants with advanced glaucoma (n = 4; age range: 51-72) and compared to two reference groups, i.e., advanced retinitis pigmentosa (n = 3; age range: 46-78) and age-matched healthy controls with simulated defects (n = 7). The participants viewed grating patterns drifting in 8 directions (12 s) alternating with uniform gray (12 s), either during passive viewing (PV), i.e., central fixation, or during a one-back task (OBT), i.e., reports of succeeding identical motion directions. As another reference, a fixation-dot task condition was included. Only in glaucoma and retinitis pigmentosa but not in controls, fMRI-responses in the lesion projection zone (LPZ) of V1 shifted from negative for PV to positive for OBT (p = 0.024 and p = 0.012, respectively). In glaucoma, these effects also reached significance in V3 (p = 0.006), while in V2 there was a non-significant trend (p = 0.069). The general absence of positive responses in the LPZ during PV underscores the lack of early visual cortex bottom-up plasticity for acquired visual field defects in humans. Trends in our exploratory analysis suggesting the task-dependent LPZ responses to be inversely related to visual field loss, indicate the benefit of patient stratification strategies in future studies with greater sample sizes. We conclude that top-down mechanisms associated with task-elicited demands rather than visual cortex remapping appear to shape LPZ responses not only in retinitis pigmentosa, but also in glaucoma. These insights are of critical importance for the development of schemes for treatment and rehabilitation in glaucoma and beyond.

11.
12.
Invest Ophthalmol Vis Sci ; 62(6): 8, 2021 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-33956052

RESUMEN

Purpose: To explore the effect of gaze direction and eyelid closure on intraocular pressure (IOP). Methods: Eleven patients with primary open-angle glaucoma previously implanted with a telemetric IOP sensor were instructed to view eight equally-spaced fixation targets each at three eccentricities (10°, 20°, and 25°). Nine patients also performed eyelid closure. IOP was recorded via an external antenna placed around the study eye. Differences of mean IOP between consecutive gaze positions were calculated. Furthermore, the effect of eyelid closure on gaze-dependent IOP was assessed. Results: The maximum IOP increase was observed at 25° superior gaze (mean ± SD: 4.4 ± 4.9 mm Hg) and maximum decrease at 25° inferonasal gaze (-1.6 ± 0.8 mm Hg). There was a significant interaction between gaze direction and eccentricity (P = 0.003). Post-hoc tests confirmed significant decreases inferonasally for all eccentricities (mean ± SEM: 10°: -0.7 ± 0.2, P = 0.007; 20°: -1.1 ± 0.2, P = 0.006; and 25°: -1.6 ± 0.2, P = 0.006). Eight of 11 eyes showed significant IOP differences between superior and inferonasal gaze at 25°. IOP decreased during eyelid closure, which was significantly lower than downgaze at 25° (mean ± SEM: -2.1 ± 0.3 mm Hg vs. -0.7 ± 0.2 mm Hg, P = 0.014). Conclusions: Our data suggest that IOP varies reproducibly with gaze direction, albeit with patient variability. IOP generally increased in upgaze but decreased in inferonasal gaze and on eyelid closure. Future studies should investigate the patient variability and IOP dynamics.


Asunto(s)
Técnicas Biosensibles/instrumentación , Párpados/fisiología , Fijación Ocular/fisiología , Glaucoma de Ángulo Abierto/diagnóstico , Presión Intraocular/fisiología , Telemetría/métodos , Tonometría Ocular/instrumentación , Anciano , Electrodos Implantados , Diseño de Equipo , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
13.
Ophthalmologe ; 118(9): 900-906, 2021 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-34032917

RESUMEN

BACKGROUND: Retinal pathologies affect the structure and function of post-retinal visual pathways. These post-retinal alterations bear the potential to obstruct the aim of innovative retinal treatment to restore visual function. OBJECTIVE: Current developments in the field of neuroimaging and the associated neurocomputational approaches enable a detailed assessment of this interrelationship. As a consequence, they open up the possibility to anticipate the success of treatment. METHODS: This review article demonstrates how innovations particularly in magnetic resonance imaging (MRI)-based anatomical, functional, and diffusion imaging can guide visual pathway assessments that are relevant for ophthalmological applications. RESULTS: Specific examples of retinal and visual pathway pathologies in the context of a detailed analysis of the visual pathway are described. CONCLUSION: A concept is introduced of how to translate the meaningful but technically and computationally challenging neuroimaging procedures into a clinical setting in order to effectively connect these procedures to innovative treatment approaches.


Asunto(s)
Imagen por Resonancia Magnética , Vías Visuales , Humanos , Neuroimagen , Retina/diagnóstico por imagen
14.
Br J Ophthalmol ; 105(5): 661-668, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32727728

RESUMEN

AIMS: (1) To test the feasibility of simultaneous steady-state pattern electroretinogram (ssPERG) and intraocular pressure (IOP) measurements with an implanted IOP sensor. (2) To explore the scope of this approach for detecting PERG changes during IOP manipulation in a model of lateral decubitus positioning (LDP; lateral position). METHODS: 15 healthy controls and 15 treated glaucoma patients participated in the study. 8 patients had an IOP sensor (Eyemate-IO, Implandata Ophthalmic Products GmbH) in the right eye (GLAIMP) and 7 had no sensor and with glaucoma in the left eye. (1) We compared PERGs with and without simultaneous IOP read-out in GLAIMP. (2) All participants were positioned in the following order: sitting1 (S1), right LDP (LDR), sitting2 (S2), left LDP (LDL) and sitting3 (S3). For each position, PERG amplitudes and IOP were determined with rebound tonometry (Icare TA01i) in all participants without the IOP sensor. RESULTS: Electromagnetic intrusions of IOP sensor read-out onto ssPERG recordings had, due to different frequency ranges, no relevant effect on PERG amplitudes. IOP and PERG measures were affected by LDP, for example, IOP was increased during LDR versus S1 in the lower eyes of GLAIMP and controls (5.1±0.6 mmHg, P0.025=0.00004 and 1.6±0.6 mmHg, P0.025=0.02, respectively) and PERG amplitude was reversibly decreased (-25±10%, P0.025=0.02 and -17±5%, P0.025, respectively). CONCLUSIONS: During LDP, both IOP and PERG changed predominantly in the lower eye. IOP changes induced by LDP may be a model for studying the interaction of IOP and ganglion-cell function.


Asunto(s)
Glaucoma/fisiopatología , Presión Intraocular/fisiología , Células Ganglionares de la Retina/fisiología , Telemedicina/instrumentación , Tonometría Ocular/instrumentación , Adulto , Anciano , Electrorretinografía , Diseño de Equipo , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Glaucoma/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
15.
Ophthalmologe ; 118(3): 239-247, 2021 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-32632493

RESUMEN

BACKGROUND: The main goals of glaucoma treatment are to preserve the visual function and maintain as high a quality of life as possible at a cost acceptable to society. Therefore, it is crucial to carefully observe each individual patient in order to determine an individual and personalized treatment approach. MATERIAL AND METHODS: This article summarizes the advantages and disadvantages of medicinal glaucoma treatment as well as traditional methods of glaucoma surgery, based on the current state of knowledge. The article explains the various mechanisms of action of new minimally invasive procedures, introduces the methods mostly commonly used in Germany and gives recommendations for preoperative care and postoperative follow-up. RESULTS/CONCLUSION: In addition to the plethora of medicinal glaucoma treatments and classical surgical procedures, new minimally invasive treatment alternatives have become available in the past few years. The latter are an option for an earlier surgical intervention, especially in naïve or previously treated patients who appear to be unsuitable for medicinal treatment.


Asunto(s)
Glaucoma , Trabeculectomía , Alemania , Glaucoma/tratamiento farmacológico , Glaucoma/cirugía , Humanos , Presión Intraocular , Mitomicina , Calidad de Vida , Estudios Retrospectivos , Resultado del Tratamiento
16.
Transl Vis Sci Technol ; 9(12): 7, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33200048

RESUMEN

Purpose: To compare the diagnostic performance and to evaluate the interrelationship of electroretinographical and structural and vascular measures in glaucoma. Methods: For 14 eyes of 14 healthy controls and 15 eyes of 12 patients with glaucoma ranging from preperimetric to advanced stages optical coherence tomography (OCT), OCT-angiography (OCT-A), and electrophysiological measures (multifocal photopic negative response ratio [mfPhNR] and steady-state pattern electroretinography [ssPERG]) were applied to assess changes in retinal structure, microvasculature, and function, respectively. The diagnostic performance was assessed via area-under-curve (AUC) measures obtained from receiver operating characteristics analyses. The interrelation of the different measures was assessed with correlation analyses. Results: The mfPhNR, ssPERG amplitude, parafoveal (pfVD) and peripapillary vessel density (pVD), macular ganglion cell inner plexiform layer thickness (mGCIPL) and peripapillary retinal nerve fiber layer thickness (pRNFL) were significantly reduced in glaucoma. The AUC for mfPhNR was highest among diagnostic modalities (AUC: 0.88, 95% confidence interval: 0.75-1.0, P < 0.001), albeit not statistically different from that for macular (mGCIPL: 0.76, 0.58-0.94, P < 0.05; pfVD: 0.81, 0.65-0.97, P < 0.01) or peripapillary imaging (pRNFL: 0.85, 0.70-1.0, P < 0.01; pVD: 0.82, 0.68-0.97, P < 0.01). Combined functional/vascular measures yielded the highest AUC (mfPhNR-pfVD: 0.94, 0.85-1.0, P < 0.001). The functional/structural measure correlation (mfPhNR-mGCIPL correlation coefficient [rs]: 0.58, P = 0.001; mfPhNR-pRNFL rs: 0.66, P < 0.001) was stronger than the functional-vascular correlation (mfPhNR-pfVD rs: 0.29, P = 0.13; mfPhNR-pVD rs: 0.54, P = 0.003). Conclusions: The combination of ERG measures and OCT-A improved diagnostic performance and enhanced understanding of pathophysiology in glaucoma. Translational Relevance: Multimodal assessment of glaucoma damage improves diagnostics and monitoring of disease progression.


Asunto(s)
Glaucoma , Tomografía de Coherencia Óptica , Angiografía , Electrorretinografía , Glaucoma/diagnóstico por imagen , Humanos , Fibras Nerviosas , Células Ganglionares de la Retina
17.
Exp Eye Res ; 200: 108242, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32926894

RESUMEN

The photopic negative response of the electroretinogram reflects retinal ganglion cell function and consequently aids diagnosis of optic nerve diseases including glaucoma. In this study, we assessed the efficacy of stimulation parameters for electroretinographic recordings of the multifocal photopic negative response (mfPhNR) for the detection of glaucoma and compared the diagnostic accuracy of electrophysiological, structural and functional measures of glaucoma. We compared the diagnostic performance of the mfPhNR for 6 different stimulation rates in a cohort of 24 controls, 10 glaucoma suspects (GLAS ) and 16 glaucoma participants (GLAG). A cross-modal comparison of the mfPhNR/b wave ratio was performed with the pattern electroretinogram (PERG), and the peripapillary retinal nerve fiber layer (pRNFL) thickness. These analyses were based on area under curves (AUC) obtained from receiver-operating-characteristics (ROC) and step-wise regression analyses. We found that compared to the other mfPhNR-conditions, the PhNR/b-wave ratio for the fastest stimulation condition had the highest AUC for GLAS (0.84, P = 0.008, 95%CI: 0.71- 0.98), while the other modalities, i.e., PERG-amplitude and pRNFL had AUCs of 0.78 (P= 0.039), and 0.74 (P < 0.05), respectively. For GLAG , the respective AUCs were 0.78 (P= 0.004), 0.85 (P< 0.001) and 0.87 (P< 0.001). pRNFL was the significant predictor for both mfPhNR/b-wave ratio [t (48) = 4, P = 0.0002] and for PERG amplitude [t (48) = 3.4, P = 0.001]. In conclusion, fast mfPhNR protocols outperform other multifocal PhNR protocols in the identification of glaucomatous damage especially for GLAS and thus aid the early detection of glaucoma, indicating its value as a surrogate marker of early stage ganglion cell dysfunction.


Asunto(s)
Electrorretinografía/métodos , Glaucoma de Ángulo Abierto/diagnóstico , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Campos Visuales/fisiología , Diagnóstico Precoz , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Curva ROC
19.
Am J Ophthalmol ; 209: 187-196, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31545953

RESUMEN

PURPOSE: The aim of this study was to investigate the safety and performance of the second generation of an implantable intraocular pressure (IOP) sensor in patients with primary open angle glaucoma (POAG). DESIGN: prospective, noncomparative, open-label, multicenter clinical investigation. METHODS: In this study, patients with POAG, regularly scheduled for cataract surgery, were implanted with a ring-shaped, sulcus-placed, foldable IOP sensor in a single procedure after intraocular lens implantation. Surgical complications as well as adverse events (AEs) during 12 months of follow-up were recorded. At each follow-up visit, a complete ophthalmic examination, including visual acuity, IOP, slit lamp examination, and dilated funduscopy as well as comparative measurements between Goldmann applanation tonometry and the EYEMATE-IO implant were performed. RESULTS: The EYEMATE-IO implant was successfully implanted in 22 patients with few surgical complications and no unexpected device-related AEs. All ocular AEs resolved quickly under appropriate treatment. Comparative measurements showed good agreement between EYEMATE-IO and Goldmann applanation tonometry (GAT) with an intraclass correlation coefficient (ICC(3,k)) of 0.783 (95% confidence interval [CI]: 0.743, 0.817). EYEMATE-IO measurements were higher than GAT, with a mean difference of 3.2 mm Hg (95% CI: 2.8, 3.5 mm Hg). CONCLUSIONS: The EYEMATE-IO sensor was safely implanted in 22 patients and performed reliably until the end of follow-up. This device allows for continual and long-term measurements of IOP.


Asunto(s)
Técnicas Biosensibles/instrumentación , Glaucoma de Ángulo Abierto/diagnóstico , Presión Intraocular/fisiología , Telemetría/métodos , Tonometría Ocular/instrumentación , Anciano , Electrodos Implantados , Diseño de Equipo , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Agudeza Visual
20.
Ophthalmologe ; 117(4): 376-378, 2020 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-31209569

RESUMEN

The diagnostic findings, therapy and course of disease are described for a case of central venous occlusion in Wyburn-Mason-Syndrome. The diagnosis was based on OCT, fluorescein angiography and cMRI. In addition, due to the macular edema an intravitreal injection with Ranibizumab was applied. The macular edema regressed and further Ranibizumab-injections as well as a panretinal laser-coagulation and possibly a cryocoagulation were planned. For a central venous occlusion with macular edema also in Wyburn-Mason-Syndrome an intravitreal anti-VEGF-inhibition leads to an improvement.


Asunto(s)
Oclusión de la Vena Retiniana , Inhibidores de la Angiogénesis , Angiografía con Fluoresceína , Humanos , Inyecciones Intravítreas , Edema Macular , Ranibizumab , Tomografía de Coherencia Óptica , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...