Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 15(10)2022 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-35629475

RESUMEN

The availability of additive manufacturing enables the fabrication of cellular bone tissue engineering scaffolds with a wide range of structural and architectural possibilities. The purpose of bone tissue engineering scaffolds is to repair critical size bone defects due to extreme traumas, tumors, or infections. This research study presented the experimental validation and evaluation of the bending properties of optimized bone scaffolds with an elastic modulus that is equivalent to the young's modulus of the cortical bone. The specimens were manufactured using laser powder bed fusion technology. The morphological properties of the manufactured specimens were evaluated using both dry weighing and Archimedes techniques, and minor variations in the relative densities were observed in comparison with the computer-aided design files. The bending modulus of the cubic and diagonal scaffolds were experimentally investigated using a three-point bending test, and the results were found to agree with the numerical findings. A higher bending modulus was observed in the diagonal scaffold design. The diagonal scaffold was substantially tougher, with considerably higher energy absorption before fracture. The shear modulus of the diagonal scaffold was observed to be significantly higher than the cubic scaffold. Due to bending, the pores at the top side of the diagonal scaffold were heavily compressed compared to the cubic scaffold due to the extensive plastic deformation occurring in diagonal scaffolds and the rapid fracture of struts in the tension side of the cubic scaffold. The failure in struts in tension showed signs of ductility as necking was observed in fractured struts. Moreover, the fractured surface was observed to be rough and dull as opposed to being smooth and bright like in brittle fractures. Dimple fracture was observed using scanning electron microscopy as a result of microvoids emerging in places of high localized plastic deformation. Finally, a comparison of the mechanical properties of the studied BTE scaffolds with the cortical bone properties under longitudinal and transverse loading was investigated. In conclusion, we showed the capabilities of finite element analysis and additive manufacturing in designing and manufacturing promising scaffold designs that can replace bone segments in the human body.

2.
Materials (Basel) ; 15(9)2022 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-35591643

RESUMEN

Bone-related defects that cannot heal without significant surgical intervention represent a significant challenge in the orthopedic field. The use of implants for these critical-sized bone defects is being explored to address the limitations of autograft and allograft options. Three-dimensional cellular structures, or bone scaffolds, provide mechanical support and promote bone tissue formation by acting as a template for bone growth. Stress shielding in bones is the reduction in bone density caused by the difference in stiffness between the scaffold and the surrounding bone tissue. This study aimed to reduce the stress shielding and introduce a cellular metal structure to replace defected bone by designing and producing a numerically optimized bone scaffold with an elastic modulus of 15 GPa, which matches the human's cortical bone modulus. Cubic cell and diagonal cell designs were explored. Strut and cell dimensions were numerically optimized to achieve the desired structural modulus. The resulting scaffold designs were produced from stainless steel using laser powder bed fusion (LPBF). Finite element analysis (FEA) models were validated through compression testing of the printed scaffold designs. The structural configuration of the scaffolds was characterized with scanning electron microscopy (SEM). Cellular struts were found to have minimal internal porosity and rough surfaces. Strut dimensions of the printed scaffolds were found to have variations with the optimized computer-aided design (CAD) models. The experimental results, as expected, were slightly less than FEA results due to structural relative density variations in the scaffolds. Failure of the structures was stretch-dominated for the cubic scaffold and bending-dominated for the diagonal scaffold. The torsional and bending stiffnesses were numerically evaluated and showed higher bending and torsional moduli for the diagonal scaffold. The study successfully contributed to minimizing stress shielding in bone tissue engineering. The study also produced an innovative metal cellular structure that can replace large bone segments anywhere in the human body.

3.
Adv Sci (Weinh) ; 9(20): e2200370, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35524640

RESUMEN

Insufficient availability of molten salt corrosion-resistant alloys severely limits the fruition of a variety of promising molten salt technologies that could otherwise have significant societal impacts. To accelerate alloy development for molten salt applications and develop fundamental understanding of corrosion in these environments, here an integrated approach is presented using a set of high-throughput (HTP) alloy synthesis, corrosion testing, and modeling coupled with automated characterization and machine learning. By using this approach, a broad range of CrFeMnNi alloys are evaluated for their corrosion resistances in molten salt simultaneously demonstrating that corrosion-resistant alloy development can be accelerated by 2 to 3 orders of magnitude. Based on the obtained results, a sacrificial protection mechanism is unveiled in the corrosion of CrFeMnNi alloys in molten salts which can be applied to protect the less unstable elements in the alloy from being depleted, and provided new insights on the design of high-temperature molten salt corrosion-resistant alloys.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...