J Arthroplasty ; 32(4): 1186-1191, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27998657

RESUMEN

BACKGROUND: Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. METHODS: Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. RESULTS: Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. CONCLUSION: This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene.


Asunto(s)
Prótesis de Cadera/efectos adversos , Osteólisis/etiología , Polietilenos/efectos adversos , Falla de Prótesis/etiología , Acetábulo , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Enfermedades de los Cartílagos , Reactivos de Enlaces Cruzados , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Polietileno , Diseño de Prótesis , Análisis Radioestereométrico , Tomografía Computarizada por Rayos X
3.
Clin Orthop Relat Res ; 473(2): 432-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25123239

RESUMEN

BACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES: The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS: At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS: This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Polietileno , Anciano , Reactivos de Enlaces Cruzados , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polietilenos , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico , Propiedades de Superficie
5.
J Bone Joint Surg Am ; 93(8): 716-22, 2011 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-21508278

RESUMEN

BACKGROUND: The use of highly cross-linked polyethylene is now commonplace in total hip arthroplasty. Hip simulator studies and short-term in vivo measurements have suggested that the wear rate of highly cross-linked polyethylene is significantly less than that of conventional ultra-high molecular weight polyethylene. However, long-term data to support its use are limited. The aim of this study was to compare the intermediate-term steady-state wear of highly cross-linked polyethylene compared with that of conventional ultra-high molecular weight polyethylene acetabular liners in a prospective, double-blind, randomized controlled trial with use of radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip replacements with either conventional ultra-high molecular weight polyethylene acetabular liners (Zimmer) or highly cross-linked polyethylene liners (Longevity; Zimmer). All patients received a cemented, collarless, polished, tapered femoral component (CPT; Zimmer) and an uncemented acetabular component (Trilogy; Zimmer). Clinical outcomes were assessed and the three-dimensional penetration of the head into the socket was determined for a minimum of seven years. Linear regression was used to calculate the steady-state wear rate following the creep-dominated penetration seen during the first year. RESULTS: At a minimum of seven years postoperatively, the mean total femoral head penetration was significantly lower in the highly cross-linked polyethylene group (0.33 mm; 95% confidence interval [CI], ±0.10 mm) than it was in the ultra-high molecular weight polyethylene group (0.55 mm; 95% CI, ±0.10 mm) (p = 0.005). The mean steady-state wear rate of highly cross-linked polyethylene was 0.005 mm/yr (95% CI, ±0.015 mm/yr), compared with 0.037 mm/yr (95% CI, ±0.019 mm/yr) for conventional ultra-high molecular weight polyethylene (p = 0.007). No patient in the highly cross-linked polyethylene group had a wear rate above the osteolysis threshold of 0.1 mm/yr, compared with 9% of patients in the ultra-high molecular weight polyethylene group. CONCLUSIONS: This study demonstrates that highly cross-linked polyethylene has a significantly lower steady-state wear rate compared with that of conventional ultra-high molecular weight polyethylene. Longer-term follow-up is required to determine if this will translate into improved clinical performance and longevity of these implants.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Polietileno , Adulto , Materiales Biocompatibles Revestidos , Método Doble Ciego , Análisis de Falla de Equipo , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Polietileno/química , Polietilenos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Propiedades de Superficie , Resultado del Tratamiento