Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Zhonghua Xue Ye Xue Za Zhi ; 45(8): 776-780, 2024 Aug 14.
Artículo en Chino | MEDLINE | ID: mdl-39307726

RESUMEN

Follicular lymphoma (FL) is highly heterogeneous with different histopathologic grades. Its biological characteristics and clinical management are different. This study retrospectively analyzed (18)F-FDG PET-CT metabolic parameters, clinical features, and their relationship with prognosis in 161 FL patients with different histopathological grades (grade 1-2, grade 3A, grade 3B) at the Shanxi Cancer Hospital. There were 93 cases in the grade 1-2 group, 40 cases in the grade 3A group, and 28 cases in the grade 3B group. The expression of LDH, CD10, EZH2, c-Myc, and CD37 proteins was correlated with histological grade (grade 1-2, grade 3A, and grade 3B) (all P values<0.05) . The SUVmax, TLG, TBR, and TLR for the three groups were different (all P values<0.05) . The optimal thresholds of SUVmax, MTV, TLG, TBR, and TLR for predicting FL disease progression were 8.32, 201.31, 2 342.55, 6.56, and 3.52, respectively, and the rate of disease progression increased in patients with higher thresholds (all P value<0.05) . ß(2)-MG (>2.3 µg/L) , Follicular lymphoma international prognostic index-1 (FLIPI-1) score (3-5 points) , negative CD37 expression, positive c-Myc expression, and TLG (>2 342.55 g) were all independent risk factors for PFS in the FL patients (HR=3.609, 2.509, 0.255, 3.506, 13.531, all P value<0.05) . (18)F-FDG PET-CT is a powerful complement to FL histopathological grading and the combination of the two may better predict the prognosis of FL patients.


Asunto(s)
Fluorodesoxiglucosa F18 , Linfoma Folicular , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Linfoma Folicular/patología , Linfoma Folicular/diagnóstico por imagen , Linfoma Folicular/diagnóstico , Pronóstico , Estudios Retrospectivos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Anciano de 80 o más Años
2.
Zhonghua Yi Xue Za Zhi ; 103(8): 566-571, 2023 Feb 28.
Artículo en Chino | MEDLINE | ID: mdl-36822867

RESUMEN

Objective: To explore the correlation between fluid load index and cardiovascular events in hemodialysis patients based on repeated body composition analyses. Methods: A prospective cohort study was conducted to collect the clinical data of patients undergoing maintenance hemodialysis (MHD) in the Department of Nephrology, Hangzhou Hospital of Traditional Chinese Medicine from July to September 2020. The pre-dialysis fluid overload (FO) index-overhydration (OH) was measured by bioelectrical impedance method, and the follow-up monitoring was conducted every 6 months. According to the baseline OH value, patients were divided into non-FO group (OH≤2.5 L) and FO group (OH>2.5 L). Moreover, according to the repeated measurements, the patients were divided into continuous non-FO group, continuous FO group and intermittent FO group. All patients were followed up until October 1, 2022, and the outcomes were recorded. The end point of follow-up was cardiovascular events. The cumulative incidence of cardiovascular events was calculated by the Kaplan-Meier method, and the risk factors of cardiovascular events were analyzed by Cox proportional hazards regression model. Results: A total of 289 patients were included, including 88 patients (30.4%) with FO and 201 patients (69.6%) with non-FO. There were 168 males (58.1%) and 121 (41.9%) females, with an average age of (58±13) years and an average follow-up time of (22.0±6.5) months. Kaplan-Meier analysis showed that the incidence of cardiovascular events in the baseline FO group was higher than that in the non-FO group (log-rank χ2=14.44, P<0.001). The incidence of cardiovascular events in both the continuous FO group and the intermittent FO group was higher than that in the continuous non-FO group (log-rank χ2=41.47, P<0.001; log-rank χ2=18.36, P<0.001). After adjustment for gender, age, comorbidities, and biochemical indicators, the incidence of cardiovascular events in the baseline FO group was 1.850 times of the non-FO group (95%CI: 1.046-3.271, P=0.034). The incidence of cardiovascular events in the continuous FO group was 4.679 times of the continuous non-FO group (95%CI: 2.189-10.002, P<0.001). The incidence of cardiovascular events in the intermittent FO group was 3.410 times of the continuous non-FO group (95%CI: 1.696-6.857, P=0.001). Conclusions: OH value measured by bioelectrical impedance can be used as an important reference index for clinical monitoring of cardiovascular events in MHD patients. Continuous chronic and intermittent exposures to FO are risk factors for cardiovascular events in hemodialysis patients.


Asunto(s)
Insuficiencia Cardíaca , Desequilibrio Hidroelectrolítico , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Diálisis Renal/efectos adversos , Factores de Riesgo , Desequilibrio Hidroelectrolítico/etiología , Insuficiencia Cardíaca/complicaciones , Composición Corporal
3.
Artículo en Chino | MEDLINE | ID: mdl-28558452

RESUMEN

Objective: Tailor-made notched music was applied to alleviate the symptoms of chronic idiopathic tinnitus and compared its effectiveness with other existing sound treatment of tinnitus. Methods: Subjects (n=43; ears=75 )were recruited during June 2015 to October 2016 from the out-patients of our hospital. These patients had chronic (longer than 6months) and idiopathic tinnitus, with or without significant sensorineural hearing loss. In the prospective design, the patients were randomly divided into group A (treated with tailor-made notched music) and group B (treated with analogous sound masking), and received the treatment for 3 months. The tinnitus scale, tinnitus questionnaire and audiological findings were evaluated before treatment, and at one month and three months after treatment started. Results: After onemonth of treatment, the effective rate between the two groups was 40.9% and 42.9%, there was no significant difference between the two groups (χ(2)= 0.017, P=0.897). The average VAS for patients in group A showed more decrease in group A than in group B(VAS: 1.8 vs. 0.8, the percentage : 29.5% vs. 13.6%), but there was no significant difference between the two groups (t=-1.450, P=0.155). After 3 months of treatment, the effective rates were 68.2% and 23.8%, respectively. There was significant difference between the two groups (χ(2)= 8.503, P=0.004). The difference of the VAS scores between the two groups was statistically significant (t=-3.263, P=0.002), and the VAS score of group A was less.After 3 months of treatment, there was significant decreaseinthe average tinnitus loudness for patients in group A(t=5.569, P<0.01), and there was no significant changein group B(t=-0.953, P=0.374). There was also significant decreasein the scores of tinnitus handicap inventory (THI) (F=7.334, P<0.05), loudness visual analog scale (VAS) (F=20.48, P<0.001), and the proportion of patients with moderate to severe tinnitus(χ(2)=11.289, P<0.05) in the group A, and there was no significant change in group B(F=2.198, F=0.989, χ(2)=1.651; P=0.120, P=0.378, P=0.438>0.05). Conclusions: Our resultssuggest that long-term normalized listening to tailor-made notched music, can significantly reduce the perceived tinnitus loudness in varying degrees and improve the quality of life of patients. The effects and possible mechanism of this method were discussedin this paper.


Asunto(s)
Musicoterapia , Acúfeno/terapia , Enfermedad Crónica , Femenino , Pérdida Auditiva Sensorineural , Humanos , Masculino , Estudios Prospectivos , Calidad de Vida , Sonido , Encuestas y Cuestionarios , Resultado del Tratamiento , Escala Visual Analógica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...