Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Circulation ; 148(25): 2029-2037, 2023 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-37886885

RESUMEN

BACKGROUND: In severely affected patients with catecholaminergic polymorphic ventricular tachycardia, beta-blockers are often insufficiently protective. The purpose of this study was to evaluate whether flecainide is associated with a lower incidence of arrhythmic events (AEs) when added to beta-blockers in a large cohort of patients with catecholaminergic polymorphic ventricular tachycardia. METHODS: From 2 international registries, this multicenter case cross-over study included patients with a clinical or genetic diagnosis of catecholaminergic polymorphic ventricular tachycardia in whom flecainide was added to beta-blocker therapy. The study period was defined as the period in which background therapy (ie, beta-blocker type [beta1-selective or nonselective]), left cardiac sympathetic denervation, and implantable cardioverter defibrillator treatment status, remained unchanged within individual patients and was divided into pre-flecainide and on-flecainide periods. The primary end point was AEs, defined as sudden cardiac death, sudden cardiac arrest, appropriate implantable cardioverter defibrillator shock, and arrhythmic syncope. The association of flecainide with AE rates was assessed using a generalized linear mixed model assuming negative binomial distribution and random effects for patients. RESULTS: A total of 247 patients (123 [50%] females; median age at start of flecainide, 18 years [interquartile range, 14-29]; median flecainide dose, 2.2 mg/kg per day [interquartile range, 1.7-3.1]) were included. At baseline, all patients used a beta-blocker, 70 (28%) had an implantable cardioverter defibrillator, and 21 (9%) had a left cardiac sympathetic denervation. During a median pre-flecainide follow-up of 2.1 years (interquartile range, 0.4-7.2), 41 patients (17%) experienced 58 AEs (annual event rate, 5.6%). During a median on-flecainide follow-up of 2.9 years (interquartile range, 1.0-6.0), 23 patients (9%) experienced 38 AEs (annual event rate, 4.0%). There were significantly fewer AEs after initiation of flecainide (incidence rate ratio, 0.55 [95% CI, 0.38-0.83]; P=0.007). Among patients who were symptomatic before diagnosis or during the pre-flecainide period (n=167), flecainide was associated with significantly fewer AEs (incidence rate ratio, 0.49 [95% CI, 0.31-0.77]; P=0.002). Among patients with ≥1 AE on beta-blocker therapy (n=41), adding flecainide was also associated with significantly fewer AEs (incidence rate ratio, 0.25 [95% CI, 0.14-0.45]; P<0.001). CONCLUSIONS: For patients with catecholaminergic polymorphic ventricular tachycardia, adding flecainide to beta-blocker therapy was associated with a lower incidence of AEs in the overall cohort, in symptomatic patients, and particularly in patients with breakthrough AEs while on beta-blocker therapy.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Femenino , Humanos , Adolescente , Masculino , Flecainida/efectos adversos , Incidencia , Estudios Cruzados , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/epidemiología , Antagonistas Adrenérgicos beta/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control
2.
Eur J Hum Genet ; 28(1): 17-22, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31534214

RESUMEN

Sudden cardiac death (SCD) is often associated with structural abnormalities of the heart during autopsy. This study sought to compare the diagnostic yield of postmortem genetic testing in (1) cases with structural findings of uncertain significance at autopsy to (2) cases with autopsy findings diagnostic of cardiomyopathy. We evaluated 57 SCD cases with structural findings at cardiac autopsy. Next-generation sequencing using a panel of 77 primary electrical disorder and cardiomyopathy genes was performed. Pathogenic and likely pathogenic variants were classified using American College of Medical Genetics (ACMG) consensus guidelines. In 29 cases (51%) autopsy findings of uncertain significance were identified whereas in 28 cases (49%) a diagnosis of cardiomyopathy was established. We identified a pathogenic or likely pathogenic variant in 10 cases (18%); in 1 (3%) case with non-specific autopsy findings compared with 9 (32%) cases with autopsy findings diagnostic of cardiomyopathy (p = 0.0054). The yield of genetic testing in SCD cases with autopsy findings consistent with cardiomyopathy is comparable with the yield in cardiomyopathy patients that are alive. Genetic testing in cases with findings of uncertain significance offers lower clinical utility than in cardiomyopathy, with lower yields than detected previously. This highlights the need for stringent evaluation of variant pathogenicity.


Asunto(s)
Cardiomiopatías/genética , Muerte Súbita Cardíaca/etiología , Genética Forense/normas , Pruebas Genéticas/normas , Adulto , Autopsia , Cardiomiopatías/epidemiología , Muerte Súbita Cardíaca/epidemiología , Femenino , Genética Forense/estadística & datos numéricos , Pruebas Genéticas/estadística & datos numéricos , Humanos , Masculino , Sensibilidad y Especificidad
3.
Eur Heart J ; 40(35): 2953-2961, 2019 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-31145795

RESUMEN

AIMS: In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), implantable cardioverter-defibrillator (ICD) shocks are sometimes ineffective and may even trigger fatal electrical storms. We assessed the efficacy and complications of ICDs placed in patients with CPVT who presented with a sentinel event of sudden cardiac arrest (SCA) while undiagnosed and therefore untreated. METHODS AND RESULTS: We analysed 136 patients who presented with SCA and in whom CPVT was diagnosed subsequently, leading to the initiation of guideline-directed therapy, including ß-blockers, flecainide, and/or left cardiac sympathetic denervation. An ICD was implanted in 79 patients (58.1%). The primary outcome of the study was sudden cardiac death (SCD). The secondary outcomes were composite outcomes of SCD, SCA, appropriate ICD shocks, and syncope. After a median follow-up of 4.8 years, SCD had occurred in three patients (3.8%) with an ICD and none of the patients without an ICD (P = 0.1). SCD, SCA, or appropriate ICD shocks occurred in 37 patients (46.8%) with an ICD and 9 patients (15.8%) without an ICD (P < 0.0001). Inappropriate ICD shocks occurred in 19 patients (24.7%) and other device-related complications in 22 patients (28.9%). CONCLUSION: In previously undiagnosed patients with CPVT who presented with SCA, an ICD was not associated with improved survival. Instead, the ICD was associated with both a high rate of appropriate ICD shocks and inappropriate ICD shocks along with other device-related complications. Strict adherence to guideline-directed therapy without an ICD may provide adequate protection in these patients without all the potential disadvantages of an ICD.


Asunto(s)
Reanimación Cardiopulmonar , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Desfibriladores Implantables/efectos adversos , Electrocardiografía , Estudios de Seguimiento , Adhesión a Directriz , Factores de Riesgo , Resultado del Tratamiento
4.
Int J Cardiol ; 241: 177-181, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28291620

RESUMEN

BACKGROUND: The increased risk of brady- and tachy-arrhythmias in the congenital heart disease (CHD) population means that cardiac rhythm management devices are often required at an early age and expose patients to device-related complications. The present study drew upon four decades of experience at a tertiary adult congenital heart disease ACHD center and aimed to investigate the indication for cardiac implantable electronic devices (CIEDs) and predictors of late device-related complication requiring re-intervention. METHODS: A retrospective review of pacing records of ACHD patients over forty years was carried out. The primary outcome measure was device related complication requiring re-intervention. RESULTS: Between 1970 and 2009, 238 structural CHD patients who received CIEDs with follow-up data were identified (structural group). As a comparator group, 98 patients with congenital conduction disease or long QT syndrome with a structurally normal heart (electrical group) were included in the study. During a mean follow-up of 9.6±8.5years, 72 (21%) patients (44 structural group, 28 electrical group) required ≥1 re-intervention due to device related complications. Multivariate analysis showed that age at the time of device implant was an independent predictor of late device-related complications (HR 0.77, 95% CI 0.60-0.98, p=0.04). Sub-analysis of the structural group showed that ACHD complexity (Bethesda guideline) was the only predictor late device-related complication in the structural group (HR 2.96, 95% CI: 1.67-5.26, p<0.01). CONCLUSION: Increasing age at device implant was inversely associated with late device-related complications. ACHD patients with complex anatomy are at increased risk of device-related complications at mid and long-term follow-up.


Asunto(s)
Estimulación Cardíaca Artificial/tendencias , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/terapia , Marcapaso Artificial/tendencias , Centros de Atención Terciaria/tendencias , Adolescente , Adulto , Estimulación Cardíaca Artificial/efectos adversos , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
5.
Circ Arrhythm Electrophysiol ; 7(5): 800-6, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25194972

RESUMEN

BACKGROUND: Sudden arrhythmic death syndrome defines a sudden unexpected and unexplained death despite comprehensive pathological and toxicological investigation. Previous studies have focused on evaluation of adult relatives. There is, however, a lack of data in children, leading to highly variable management. We sought to determine the clinical utility of cardiac evaluation in pediatric relatives of sudden arrhythmic death syndrome probands. METHODS AND RESULTS: Retrospective review was undertaken of pediatric patients with a family history of sudden arrhythmic death syndrome assessed from 2010 to 2013 in 2 centers. Clinical history, cardiac, and genetic investigations were assessed, including diagnoses made after evaluation of adult relatives. A total of 112 pediatric relatives from 61 families were evaluated (median age at presentation, 8 years; range, 0.5-16 years). A probable diagnosis was made in 18 (29.5%) families: Brugada syndrome, 13/18 (72%); long QT syndrome, 3/18 (17%); and catecholaminergic polymorphic ventricular tachycardia, 2/18 (11%). Genetic testing identified mutations in 20% of Brugada syndrome (2/10) and 50% of long QT syndrome (1/2) and catecholaminergic polymorphic ventricular tachycardia families (1/2) who were tested. Pediatric evaluation diagnosed 6/112 relatives (5.4%), increasing to 7% (6/85) if only first-degree relatives were assessed. The only useful diagnostic tests were the 12-lead and exercise electrocardiograms and ajmaline provocation test. The median duration of follow-up was 2.1 years (range, 0.2-8.2 years) with no cardiac events. CONCLUSIONS: The yield of evaluating pediatric relatives is significant and higher when focused on first-degree relatives and on conditions usually expressed in childhood. We propose a management pathway for these children.


Asunto(s)
Ajmalina , Antiarrítmicos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Adolescente , Adulto , Factores de Edad , Arritmias Cardíacas/mortalidad , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/mortalidad , Niño , Preescolar , Femenino , Predisposición Genética a la Enfermedad , Pruebas Genéticas , Humanos , Lactante , Londres , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/mortalidad , Masculino , Persona de Mediana Edad , Linaje , Fenotipo , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética , Taquicardia Ventricular/mortalidad , Factores de Tiempo , Adulto Joven
6.
Int J Cardiol ; 168(4): 3514-21, 2013 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-23701935

RESUMEN

BACKGROUND: Early recognition and accurate risk stratification are important in the management of arrhythmogenic right ventricular cardiomyopathy (ARVC). Identification of predictors of outcome by cardiovascular magnetic resonance (CMR) in patients undergoing evaluation for ARVC is limited. We investigated the predictive value of morphological abnormalities detected by CMR for major clinical events in patients with suspected ARVC. METHODS: We performed a longitudinal study on 369 consecutive patients with at least one criterion for ARVC. Abnormal CMR was defined by the presence of one of the following: increased right ventricular (RV) volumes, reduced RV ejection fraction, RV regional wall motion abnormalities, myocardial fatty infiltration, and myocardial fibrosis. The end-point was a composite of cardiac death, sustained ventricular tachycardia, ventricular fibrillation, and appropriate ICD discharge. RESULTS: Twenty patients met the composite end-point over a mean follow-up of 4.3±1.5 years. An abnormal CMR was an independent predictor of outcomes (p<0.001). The presence of multiple abnormalities heralded a particular high risk of events (HR 23.0, 95% CI 5.7-93.2, p<0.001 for 2 abnormalities; HR 35.8, 95% CI 9.7-132.6, p<0.001 for 3 or more abnormalities). The positive predictive value of an abnormal CMR study was 21.0% for an adverse event, whilst the negative predictive value of a normal CMR study was 98.8% over the follow-up period. CONCLUSIONS: CMR provides important prognostic information in patients under evaluation for ARVC. A normal study portends a good prognosis. Conversely, the presence of multiple abnormalities identifies a high risk group of patients who may benefit from ICD implantation.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Imagen por Resonancia Cinemagnética/métodos , Adulto , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
7.
Pediatr Cardiol ; 34(3): 760-3, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23086190

RESUMEN

A 6-year-old girl with evidence of a parahisian accessory pathway on a baseline electrocardiogram underwent successful catheter ablation using magnetic navigation. Magnetic remote controlled ablation eliminated the parahisian pathway with the first radiofrequency application. A second anterolaterally located concealed pathway was successfully ablated in the same session, resulting in exclusively atrioventricular nodal conduction bidirectionally (total fluoroscopy, 4 min; 25 µGy).


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter/métodos , Magnetismo/instrumentación , Síndrome de Wolff-Parkinson-White/cirugía , Ablación por Catéter/instrumentación , Niño , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Recuperación de la Función , Resultado del Tratamiento , Síndrome de Wolff-Parkinson-White/diagnóstico
8.
Eur Heart J ; 33(11): 1351-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22408031

RESUMEN

AIMS: This paper describes our clinical experience of using an entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) in children and adults. Maintaining lead integrity and long-term vascular access are critical challenges of ICD therapy, especially in younger patients. The S-ICD has considerable theoretical advantages in selected patients without pacing indications, particularly children and young adults. Although sensing in an S-ICD may be influenced by age, pathology, and posture, there are currently few published data on clinical sensing performance outside the setting of intra-operative testing or in younger patients. METHODS AND RESULTS: Patients were selected by a multi-disciplinary team on clinical grounds for S-ICD implantation from a broad population at risk of sudden arrhythmic death. Sixteen patients underwent implantation [median age 20 years (range 10-48 years)]. Twelve had primary electrical disease and four had congenital structural heart disease. There were no operative complications, and ventricular fibrillation (VF) induction testing was successful in all cases. During median follow-up of 9 months (range 3-15 months), three children required re-operation. Eighteen clinical shocks were delivered in six patients. Ten shocks in four patients were inappropriate due to T-wave over-sensing. Within the eight shocks for ventricular arrhythmia, three were delivered for VF, among which two had delays in detection with time to therapy of 24 and 27 s. CONCLUSION: The S-ICD is an important new option for some patients. However, these data give cause for caution in light of the limited published data regarding clinical sensing capabilities, particularly among younger patients.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Adolescente , Adulto , Estudios de Casos y Controles , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
9.
Circ Arrhythm Electrophysiol ; 5(1): 131-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22062797

RESUMEN

BACKGROUND: Improvement in outcome of infants born with congenital heart defects has been accompanied by an increasing frequency of late arrhythmias. Ablation is difficult because of multiple tachycardias in the presence of complex anatomy with limited accessibility. We report on remote-controlled ablation using magnetic navigation in conjunction with 3D image integration in patients with previous intra-atrial baffle procedures. METHODS AND RESULTS: Thirteen patients (8 male; age, 30.5±8 years) with supraventricular tachycardia (SVT) underwent catheter ablation. Group A had a medical history of a Mustard or Senning operation, whereas group B had undergone total cavopulmonary connection. A total of 26 tachycardias were treated in 17 procedures (median cycle length of 280 ms). Group A patients had more inducible SVTs than group B, and all index SVTs were located in the remainder of the morphological right atrium in all but 1 patient. Retrograde access through the aorta was performed and led to successful ablation, using magnetic navigation with a very low total radiation exposure (median of 3.8 minutes in group A versus 5.9 minutes in group B). Only 1 of 13 patients continued to have short-lasting SVTs despite 3 ablation procedures during a median follow-up time of >200 days. CONCLUSIONS: Remote-controlled catheter ablation by magnetic navigation in combination with accurate 3D image integration allowed safe and successful elimination of SVTs, using an exclusively retrograde approach, resulting in low radiation exposure for patients after intra-atrial baffle procedures (Mustard, Senning, or total cavopulmonary connection).


Asunto(s)
Ablación por Catéter/métodos , Atrios Cardíacos/inervación , Sistema de Conducción Cardíaco/cirugía , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Robótica/métodos , Taquicardia Supraventricular/cirugía , Adulto , Femenino , Estudios de Seguimiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/patología , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Taquicardia Supraventricular/diagnóstico , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
Circulation ; 115(13): 1738-46, 2007 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-17372177

RESUMEN

BACKGROUND: The right atrium late after the Fontan procedure is characterized by multiple complex arrhythmia circuits. We performed simultaneous electroanatomic and noncontact mapping to assess the accuracy of both systems to identify scar and arrhythmia. METHODS AND RESULTS: Mapping was performed in 26 patients aged 26.8+/-8.9 years, 18.7+/-4.4 years after Fontan surgery. The area and site of abnormal endocardium defined by electroanatomic mapping (bipolar contact electrogram <0.5 mV) were compared with those defined by noncontact mapping during sinus rhythm and by dynamic substrate mapping. Contact and reconstructed unipolar electrograms at a known distance from the multielectrode array, recorded by the noncontact system simultaneously at 452 endocardial sites, were compared for morphological cross correlation, timing difference, and amplitude. Mapping of arrhythmias was performed with both systems when possible. The median patient abnormal endocardium as defined by electroanatomic mapping covered 38.0% (range 16.7% to 97.8%) of the right atrial surface area, as opposed to 60.9% (range 21.3% to 98.5%) defined by noncontact mapping during sinus rhythm and 11.9% (range 0.4% to 67.3%) by dynamic substrate mapping. A significant decrease in electrogram cross correlation (P=0.003), timing (P=0.012), and amplitude (P=0.003) of reconstructed electrograms, but not of contact electrograms (P=0.742), was seen at endocardial sites >40 mm from the multielectrode array. Successful arrhythmia mapping by electroanatomic versus noncontact mapping was superior in 15 patients (58%), the same in 6 (23%), and inferior in 5 (19%; P=0.044). CONCLUSIONS: Electroanatomic mapping is the superior modality for arrhythmia mapping late after the Fontan procedure. Noncontact mapping is limited by a significant reduction in reconstructed electrogram correlation, timing, and amplitude >40 mm from the multielectrode array and cannot accurately define areas of scar and low-voltage endocardium.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Cateterismo Cardíaco/métodos , Cicatriz/fisiopatología , Diagnóstico por Computador/métodos , Endocardio/fisiopatología , Procedimiento de Fontan/efectos adversos , Atrios Cardíacos/fisiopatología , Imagenología Tridimensional/métodos , Adolescente , Adulto , Envejecimiento , Amiodarona/uso terapéutico , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Función del Atrio Derecho , Cateterismo Cardíaco/instrumentación , Ablación por Catéter , Cicatriz/patología , Terapia Combinada , Diagnóstico por Computador/instrumentación , Resistencia a Medicamentos , Electrocardiografía , Electrodos , Endocardio/patología , Femenino , Procedimiento de Fontan/métodos , Atrios Cardíacos/patología , Atrios Cardíacos/cirugía , Humanos , Imagenología Tridimensional/instrumentación , Masculino , Modelos Cardiovasculares , Tamaño de los Órganos , Periodo Posoperatorio , Presión , Circulación Pulmonar , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Taquicardia/tratamiento farmacológico , Taquicardia/etiología , Taquicardia/fisiopatología , Taquicardia/terapia , Vena Cava Superior/fisiopatología , Vena Cava Superior/cirugía
11.
Cardiol Young ; 15(4): 417-21, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16014191

RESUMEN

Congenital anomalies of the tricuspid valve, and/or its supporting apparatus, leading to severe tricuspid regurgitation are rare. Although well tolerated in early childhood, long-standing and progressive volume loading of the right heart leads to symptoms of decreased exercise tolerance, and may predispose to arrhythmias in the long term. We report three cases of severe tricuspid regurgitation related to anomalies of the cords supporting the antero-superior leaflet of the tricuspid valve. Shortened cords leading to tethering of the leaflet were seen in two cases, and hypoplasia of the leaflet in the other. In all cases, the regurgitant jet was directed posteriorly towards the coronary sinus and atrial septum. Surgical repair was possible in one case, while it proved necessary to replace the valve in a second. The third child is asymptomatic and under regular review.


Asunto(s)
Cuerdas Tendinosas/anomalías , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/anomalías , Niño , Cuerdas Tendinosas/diagnóstico por imagen , Cuerdas Tendinosas/patología , Progresión de la Enfermedad , Ecocardiografía Doppler en Color , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Índice de Severidad de la Enfermedad , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Insuficiencia de la Válvula Tricúspide/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...