Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur J Prev Cardiol ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38916491

RESUMEN

AIM: Lipoprotein(a) [Lp(a)] has demonstrated its association with atherosclerosis and myocardial infarction. However, its role in the development of in-stent restenosis (ISR) after percutaneous coronary intervention (PCI) is not clearly established. The aim of this study is to investigate the association between Lp(a) and ISR. METHODS: A retrospective study of adult patients who underwent successful PCI between January 2006 and December 2017 at the three Mayo Clinic sites and had a preprocedural Lp(a) measurement was conducted. Patients were divided into two groups according to the serum Lp(a) concentration (high Lp(a) ≥50 mg/dl and low Lp(a) <50 mg/dl). Univariable and multivariable analyses were performed to compare risk of ISR between patients with high Lp(a) versus those with low Lp(a). RESULTS: A total of 1209 patients were included, with mean age 65.9 ±11.7 years and 71.8% were male. Median follow-up after baseline PCI was 8.8 (IQR 7.4) years. Restenosis was observed in 162 (13.4%) patients. Median serum levels of Lp(a) were significantly higher in patients affected by ISR versus non-affected cases: 27 (IQR 73.8) vs. 20 (IQR 57.5) mg/dL, p=0.008. The rate of ISR was significantly higher among patients with high Lp(a) versus patients with low Lp(a) values (17.0% vs 11.6%, p=0.010). High Lp(a) values were independently associated with ISR events (HR 1.67, 95%CI 1.18 to 2.37, p=0.004), and this association was more prominent after the first year following the PCI. CONCLUSION: Lipoprotein(a) is an independent predictor for long-term in-stent restenosis and should be considered in the evaluation of patients undergoing PCI.


The role of Lp(a) in the development of in-stent restenosis is not clearly established. In this study including 1209 patients who underwent successful percutaneous coronary intervention and had a preprocedural Lp(a) measurement between 2006 and 2017, the rates of restenosis were significantly higher among patients with high Lp(a) versus patients with low Lp(a) values and high Lp(a) concentrations were independently associated with restenosis events. Lp(a) should be considered as a risk factor for long term in-stent restenosis in the evaluation of patients undergoing percutaneous coronary intervention and assessed as a potential therapeutic target for reducing residual cardiovascular risk in this population.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...