Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Brachytherapy ; 22(6): 746-752, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37722989

RESUMEN

PURPOSE: We aimed to assess the clinical feasibility and advantages of using a novel hybrid brachytherapy technique by placing Freehand Interstitial Needles in addition to the Tandem and Ovoid applicator (FINITO) for the treatment of locally advanced cervical cancer (LAC). METHODS AND MATERIALS: A retrospective analysis was performed on two cohorts of patients with LACC treated at our institution: 29 patients in the FINITO group and 17 patients in the control group using T&O only approach. Clinical outcomes of interest included local control (LC), progression-free survival (PFS), overall survival (OS), and rates of acute and late toxicities. Kaplan-Meier methodology was used to estimate OS, PFS, and LC. Wilcoxon signed-rank test was used to compare the median values for dosimetry parameters. A p-value of ≤ 0.05 was considered statistically significant. All statistical analyses were performed using RStudio. RESULTS: At a median of 2 years there was no difference in rates of OS, PFS or LC between the FINITO and the control group of patients. The 2-year OS, PFS, and LC for the FINITO group were 59% (95% CI 34%-100%), 58% (95% CI 38%-89%), and 84% (95% CI 69%-100%), respectively. Late toxicities were significantly lower in the FINITO group for both gastrointestinal and genitourinary symptoms (p = 0.001 and 0.01, respectively) as compared to the T&O group. CONCLUSION: Based on the equivalent LC rate and lower toxicity profile, our FINITO technique appears to be an excellent alternative to the standard intracavitary brachytherapy in patients with advanced disease, especially in resource-limited settings.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Femenino , Humanos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/tratamiento farmacológico , Dosificación Radioterapéutica , Braquiterapia/métodos , Estudios Retrospectivos , Supervivencia sin Progresión
2.
Brachytherapy ; 21(2): 255-259, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35031255

RESUMEN

The treatment of borderline resectable (BR) pancreatic cancer is challenging and requires a multidisciplinary approach with chemotherapy, radiation and surgical resection. Despite using chemotherapy and radiotherapy in the neoadjuvant setting, achievement of negative surgical margins remains technically challenging. Positive margins are associated with increased local recurrences and worse overall survival and there are no standard options for treatment. The CivaSheet is an FDA-cleared implantable sheet with a matrix of unidirectional planar low-dose-rate (LDR) Palladium-103 (Pd-103) sources. The sources are shielded on one side with gold to spare radio-sensitive structures such as the bowel. The sheet can easily be customized and implanted at the time of surgery when there is concern for close or positive margins. The CivaSheet provides an interesting solution to target the region of close/positive margins after pancreatectomy. Here we discuss the physical properties, the dosimetry, clinical workflow and early patient outcomes with the CivaSheet in pancreatic cancer.


Asunto(s)
Braquiterapia , Neoplasias Pancreáticas , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Braquiterapia/métodos , Humanos , Terapia Neoadyuvante , Paladio/uso terapéutico , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/cirugía , Radioisótopos/uso terapéutico
3.
Brachytherapy ; 20(4): 771-780, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33994342

RESUMEN

PURPOSE: Implanted fiducial markers are a commonly used tool in delineating the CTV in high-dose-rate interstitial brachytherapy (HDR-ISBT) for gynecologic malignancy, but their reliability in gynacological sites is not well understood. These markers and interstitial applicators can experience interfractional motion due to organ swelling or other anatomical changes. The purpose of this study was to evaluate the spatial variation of these features. METHODS AND MATERIALS: The spatial positions of 50 implanted markers and 202 needles were tracked in 15 patients treated over 70 fractions of HDR brachytherapy. Marker and/or needle coordinates were extracted from CT images with contours and dose distributions. Automated analysis determined marker self-consistency and displacements between various elements of the implant. RESULTS: From start to end fraction, the relative positions of the markers experienced an average magnitude displacement of 4.5 ± 3.0 mm while the average displacement of the applicator tips was 11 ± 8 mm, relative to their respective centers of mass (CM). CONCLUSIONS: Markers implanted lateral and superior to the CTV experience greater drift than other implant locations.


Asunto(s)
Braquiterapia , Neoplasias de los Genitales Femeninos , Braquiterapia/métodos , Femenino , Marcadores Fiduciales , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Neoplasias de los Genitales Femeninos/radioterapia , Humanos , Agujas , Dosificación Radioterapéutica , Reproducibilidad de los Resultados
4.
Brachytherapy ; 20(1): 207-217, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32978081

RESUMEN

BACKGROUND: Margin negative resection in pancreatic cancer remains the only curative option but is challenging, especially with the retroperitoneal margin. Intraoperative radiation therapy (IORT) can improve rates of local control but requires specially designed facilities and equipment. This retrospective review describes initial results of a novel implantable mesh of uni-directional low dose rate (LDR) Pd-103 sources (sheet) used to deliver a focal margin-directed high-dose boost in patients with concern for close or positive margins. METHODS: Eleven consecutive patients from a single institution with resectable or borderline resectable pancreatic cancer with concern for positive margins were selected for sheet placement and retrospectively reviewed. Procedural outcomes, including the time to implant the device and complications, and clinical outcomes, including survival and patterns of failure, are reported. A dosimetric comparison of the LDR sheet with hypothetical stereotactic body radiotherapy (SBRT) boost is reported. RESULTS: One patient had a resectable disease, and 10 patients had a borderline resectable disease and underwent neoadjuvant treatment. Sheet placement added 15 min to procedural time with no procedural or sheet-related complications. At a median follow up of 13 months, 64% (n = 7) of patients are alive and 55% (n = 6) are disease-free. Compared to a hypothetical SBRT boost, the LDR sheet delivered a negligible dose to kidneys, liver, and spinal cord with a 50% reduction in max dose to the small bowel. CONCLUSION: This is the first report of the use of an implantable uni-directional LDR brachytherapy sheet in patients with resected pancreatic cancer with concern for margin clearance, with no associated toxicity and favorable clinical outcomes.


Asunto(s)
Braquiterapia , Neoplasias Pancreáticas , Braquiterapia/métodos , Estudios de Factibilidad , Humanos , Terapia Neoadyuvante , Paladio , Neoplasias Pancreáticas/radioterapia , Radioisótopos , Estudios Retrospectivos
5.
Brachytherapy ; 19(6): 783-786, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33168476

RESUMEN

PURPOSE: Gynecologic brachytherapy is an essential component in the curative treatment of cervical cancer. With the decline in brachytherapy utilization, gynecologic brachytherapy simulators are being used to provide a mechanism to enhance proficiency-based resident training. However, most models that have been used lack procedural fidelity as they are either repurposed from OB/GYN basic models or from physics phantoms. Therefore, we set out to develop a high-fidelity, ultrasound- and CT-compatible gynecologic brachytherapy training simulator. METHODS AND MATERIALS: Based on prior experience with gynecologic training simulators on the market, we developed a wish list for an ultrasound-compatible brachytherapy training model. A custom simulator was developed based on an existing pelvic ultrasound trainer. Features included a cervical os and endometrial canal as well as a palpable and hypoechoic cervical tumor. RESULTS: The model took about 3 months from the initial meeting with the developer to completion. The properties of the material were equivalent to water for ultrasound, CT, and also MRI and the model did not show signs of degradation after multiple tandem insertions. CONCLUSIONS: A high-fidelity ultrasound-compatible simulator was effectively developed and utilized to improve resident training to perform brachytherapy implants with a derivative benefit in the long term of improving survival for women with advanced gynecologic malignancies through having access to more proficient brachytherapists. Future directions include enhancing the model to allow for repetitive needle insertion and suturing for interstitial training as well as creating variations in anatomy (e.g., retroverted uterus, bulky tumors, etc.) for more advanced technical training.


Asunto(s)
Braquiterapia , Modelos Anatómicos , Fantasmas de Imagen , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia , Braquiterapia/métodos , Femenino , Humanos , Imagen por Resonancia Magnética , Entrenamiento Simulado , Materiales de Enseñanza , Ultrasonografía
6.
JAMA Oncol ; 6(1): 75-82, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31750868

RESUMEN

IMPORTANCE: Mastectomy is standard for recurrence of breast cancer after breast conservation therapy with whole breast irradiation. The emergence of partial breast irradiation led to consideration of its application for reirradiation after a second lumpectomy for treatment of recurrence of breast cancer in the ipsilateral breast. OBJECTIVES: To assess the effectiveness and adverse effects of partial breast reirradiation after a second lumpectomy and whether the treatment is an acceptable alternative to mastectomy. DESIGN, SETTING, AND PARTICIPANTS: The NRG Oncology/Radiation Therapy Oncology Group 1014 trial is a phase 2, single-arm, prospective clinical trial of 3-dimensional, conformal, external beam partial breast reirradiation after a second lumpectomy for recurrence of breast cancer in the ipsilateral breast after previous whole breast irradiation. The study opened on June 4, 2010, and closed June 18, 2013. Median follow-up was 5.5 years. This analysis used all data received at NRG Oncology through November 18, 2018. Eligible patients experienced a recurrence of breast tumor that was less than 3 cm and unifocal in the ipsilateral breast more than 1 year after breast-conserving therapy with whole breast irradiation and who had undergone excision with negative margins. INTERVENTIONS: Adjuvant partial breast reirradiation, 1.5 Gy twice daily for 30 treatments during 15 days (45 Gy), using a 3-dimensional conformal technique. MAIN OUTCOMES AND MEASURES: The main outcomes of the present study were the predefined secondary study objectives of recurrence of breast cancer in the ipsilateral breast, late adverse events (>1 year after treatment), mastectomy incidence, distant metastasis-free survival, overall survival, and circulating tumor cell incidence. RESULTS: A total of 65 women were enrolled, with 58 evaluable for analysis (mean [SD] age, 65.12 [9.95] years; 48 [83%] white). Of the recurrences of breast cancer in the ipsilateral breast, 23 (40%) were noninvasive and 35 (60%) were invasive. In all 58 patients, 53 (91%) had tumors 2 cm or smaller. All tumors were clinically node negative. A total of 44 patients (76%) tested positive for estrogen receptor, 33 (57%) for progesterone receptor, and 10 (17%) for ERBB2 (formerly HER2 or HER2/neu) overexpression. Four patients had breast cancer recurrence, with a 5-year cumulative incidence of 5% (95% CI, 1%-13%). Seven patients underwent ipsilateral mastectomies for a 5-year cumulative incidence of 10% (95% CI, 4%-20%). Both distant metastasis-free survival and overall survival rates were 95% (95% CI, 85%-98%). Four patients (7%) had grade 3 and none had grade 4 or higher late treatment adverse events. CONCLUSIONS AND RELEVANCE: For patients experiencing recurrence of breast cancer in the ipsilateral breast after lumpectomy and whole breast irradiation, a second breast conservation was achievable in 90%, with a low risk of re-recurrence of cancer in the ipsilateral breast using adjuvant partial breast reirradiation. This finding suggests that this treatment approach is an effective alternative to mastectomy.


Asunto(s)
Neoplasias de la Mama , Reirradiación , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Terapia Combinada , Femenino , Humanos , Mastectomía , Mastectomía Segmentaria , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/radioterapia , Recurrencia Local de Neoplasia/cirugía , Estudios Prospectivos
7.
Brachytherapy ; 18(6): 763-770, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31558353

RESUMEN

PURPOSE: The purpose of the study was to investigate the impact on dose distribution and radiobiological metrics of common high-dose-rate vaginal brachytherapy treatment parameters and to analyze multiinstitutional data for clinically significant impact on outcomes in early-stage endometrial cancer. METHODS AND MATERIALS: Treatment plans were created for all combinations of prescription parameters and used to quantify the dosimetric impact of each parameter and to estimate the dose delivered using common voxel-integrated radiobiological metrics. A rating system, based on risk grouping from GOG and PORTEC trials, was used to consolidate staging information into a cancer "aggressiveness" measure. Correlations between the rating, toxicity, disease recurrence, and plan parameters were investigated. RESULTS: When prescribing to 5 mm depth, the variation caused by the diameter was very large across all dose metrics, ranging from 51% to 175% increase with the most divergence in BEDmax. For surface prescription, changing the cylinder diameter from 4 cm to 2 cm caused the dose metrics of BEDmin, Dmin, and gBEUD (a = -3) to increase by 117%, 67%, and 52%, respectively. Prescription to 5-mm depth caused changes across all dose metrics of 260% compared with surface prescription for a 2-cm cylinder. Deeper prescription point (p = 0.005) and longer treatment length (p = 0.01) were correlated with increased stenosis rates. No correlation between recurrence and any plan parameter was found. CONCLUSIONS: Dramatic differences in dose distributions arise by small variations of plan parameters, with large impact on rates of vaginal stenosis, but no clear relation with local recurrence. To help radiation oncologists interpret the magnitude of these effects for their patients, we created a tool that allows comparison between dose and fractionation parameters.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias Endometriales/radioterapia , Estadificación de Neoplasias , Fraccionamiento de la Dosis de Radiación , Neoplasias Endometriales/diagnóstico , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad , Radiometría , Dosificación Radioterapéutica , Vagina
9.
Brachytherapy ; 17(4): 653-659, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29705049

RESUMEN

PURPOSE: Although brachytherapy increases the local control rate for cervical cancer, there has been a progressive decline in its use. Furthermore, the training among residency programs for gynecologic brachytherapy varies considerably, with some residents receiving little to no training. This trend is especially concerning given the association between poor applicator placement and decline in local control. Considering the success of proficiency-based training in other procedural specialties, we developed and implemented a proficiency-based cervical brachytherapy training curriculum for our residents. METHODS AND MATERIALS: Each resident placed tandem and ovoid applicators with attending guidance and again alone 2 weeks later using a pelvic model that was modified to allow for cervical brachytherapy. Plain films were taken of the pelvic model, and applicator placement quality was evaluated. Other evaluated metrics included retention of key procedural details, the time taken for each procedure and presession and postsession surveys to assess confidence. RESULTS: During the initial session, residents on average met 4.5 of 5 placement criteria, which improved to 5 the second session. On average, residents were able to remember 7.6 of the 8 key procedural steps. Execution time decreased by an average of 10.5%. Resident confidence with the procedure improved dramatically, from 2.6 to 4.6 of 5. Residents who had previously never performed a tandem and ovoid procedure showed greater improvements in these criteria than those who had. All residents strongly agreed that the training was helpful and wanted to participate again the following year. CONCLUSIONS: Residents participating in this simulation training had measurable improvements in the time to perform the procedure, applicator placement quality, and confidence. This curriculum is easy to implement and is of great value for training residents, and would be particularly beneficial in programs with low volume of cervical brachytherapy cases. Simulation programs could also be created for other technically challenging radiation oncology procedures.


Asunto(s)
Braquiterapia , Curriculum , Educación de Postgrado en Medicina/métodos , Internado y Residencia/métodos , Oncología Médica/educación , Fantasmas de Imagen , Neoplasias del Cuello Uterino/radioterapia , Femenino , Humanos , Encuestas y Cuestionarios
11.
Int J Radiat Oncol Biol Phys ; 99(1): 219-226, 2017 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-28816149

RESUMEN

PURPOSE: When brachytherapy doses are reported or added, biologically effective dose (BED) minimum dose covering 90% of the volume (D90) is used as if dose is delivered uniformly to the target. Unlike BED(D90), equivalent uniform BED (EUBED) and generalized biologically equivalent uniform dose (gBEUD) are quantities that integrate dose inhomogeneity. Here we compared BED(D90) and equivalent uniform BED (EUBED)/gBEUD in 3 settings: (1) 2 sites using tandem and ovoid (T&O) but different styles of implants; (2) 2 sites using different devices-T&O and tandem and ring (T&R)-and different styles; and (3) the same site using T&O and T&R with the same style. METHODS AND MATERIALS: EUBED and gBEUD were calculated for 260 fractions from 3 institutions using BED(α/ß = 10 Gy). EUBED uses an extra parameter α with smaller values associated with radioresistant tumors. Similarly, gBEUD uses a, which places variable emphasis on hot/cold spots. Distributions were compared using the Kolmogorov-Smirnoff test at 5% significance. RESULTS: For the 2 sites using T&O, the distribution of EUBED-BED(D90) was not different for values of α = 0.5 to 0.3 Gy-1 but was statistically different for values of α = 0.15 to 0.05 Gy-1 (P=.01, .002). The mean percentage differences between EUBED and BED(D90) ranged from 20% to 100% for α = 0.5 Gy-1 to 0.05 Gy-1. Using gBEUD-BED(D90), the P values indicate the distributions to be similar for a = -10 but to be significantly different for other values of a (-5, -1, 1). Between sites and at the same site using T&O versus T&R, the distributions were statistically different with EUBED/gBEUD irrespective of parameter values at which these quantities were computed. These differences indicate that EUBED/gBEUD capture differences between the techniques and applicators that are not detected by the BED(D90). CONCLUSIONS: BED(D90) is unable to distinguish between plans created by different devices or optimized differently. EUBED/gBEUD distinguish between dose distributions created by different devices and styles of implant and planning. This discrepancy is particularly important with the increased use of magnetic resonance imaging and hybrid devices, whereby one has the ability to create dose distributions that are significant departures from the classic pear.


Asunto(s)
Braquiterapia/métodos , Planificación de la Radioterapia Asistida por Computador , Efectividad Biológica Relativa , Neoplasias del Cuello Uterino/radioterapia , Algoritmos , Braquiterapia/normas , Femenino , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Planificación de la Radioterapia Asistida por Computador/normas , Estudios Retrospectivos , Estadísticas no Paramétricas
12.
Brachytherapy ; 16(5): 919-928, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28676428

RESUMEN

PURPOSE: To develop a consensus report for the quality practice of accelerated partial breast irradiation (APBI) using interstitial multicatheter brachytherapy (IMB). METHODS AND MATERIALS: The American Brachytherapy Society Board appointed an expert panel with clinical and research experience with breast brachytherapy to provide guidance for the current practice of IMB. This report is based on a comprehensive literature review with emphasis on randomized data and expertise of the panel. RESULTS: Randomized trials have demonstrated equivalent efficacy of APBI using IMB compared with whole breast irradiation for select patients with early-stage breast cancer. Several techniques for placement of interstitial catheters are described, and importance of three-dimensional planning with appropriate optimization is reviewed. Optimal target definition is outlined. Commonly used dosing schemas include 50 Gy delivered in pulses of 0.6-0.8 Gy/h using pulsed-dose-rate technique and 34 Gy in 10 fractions, 32 Gy in eight fractions, or 30 Gy in seven fractions using high-dose-rate technique. Potential toxicities and strategies for toxicity avoidance are described in detail. Dosimetric constraints include limiting whole breast volume that receives ≥50% of prescription dose to <60%, skin dose to ≤100% of prescription dose (≤60-70% preferred), chest wall dose to ≤125% of prescription dose, Dose Homogeneity Index to >0.75 (>0.85 preferred), V150 < 45 cc, and V200 < 14 cc. Using an optimal implant technique coupled with optimal planning and appropriate dose constraints, a low rate of toxicity and a good-to-excellent cosmetic outcome of ≥90% is expected. CONCLUSIONS: IMB is an effective technique to deliver APBI for appropriately selected women with early-stage breast cancer. This consensus report has been created to assist clinicians in the appropriate practice of APBI using IMB.


Asunto(s)
Braquiterapia/normas , Neoplasias de la Mama/radioterapia , Braquiterapia/efectos adversos , Braquiterapia/métodos , Mama/efectos de la radiación , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Consenso , Femenino , Humanos , Mamografía/métodos , Mamografía/normas , Mastectomía Segmentaria , Persona de Mediana Edad , Selección de Paciente , Traumatismos por Radiación/prevención & control , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Adyuvante/métodos , Radioterapia Adyuvante/normas , Radioterapia Guiada por Imagen/métodos , Radioterapia Guiada por Imagen/normas , Piel/efectos de la radiación , Estados Unidos
13.
Int J Radiat Oncol Biol Phys ; 98(5): 1028-1035, 2017 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-28721885

RESUMEN

PURPOSE: To determine the associated toxicity, tolerance, and safety of partial-breast reirradiation. METHODS AND MATERIALS: Eligibility criteria included in-breast recurrence occurring >1 year after whole-breast irradiation, <3 cm, unifocal, and resected with negative margins. Partial-breast reirradiation was targeted to the surgical cavity plus 1.5 cm; a prescription dose of 45 Gy in 1.5 Gy twice daily for 30 treatments was used. The primary objective was to evaluate the rate of grade ≥3 treatment-related skin, fibrosis, and/or breast pain adverse events (AEs), occurring ≤1 year from re-treatment completion. A rate of ≥13% for these AEs in a cohort of 55 patients was determined to be unacceptable (86% power, 1-sided α = 0.07). RESULTS: Between 2010 and 2013, 65 patients were accrued, and the first 55 eligible and with 1 year follow-up were analyzed. Median age was 68 years. Twenty-two patients had ductal carcinoma in situ, and 33 had invasive disease: 19 ≤1 cm, 13 >1 to ≤2 cm, and 1 >2 cm. All patients were clinically node negative. Systemic therapy was delivered in 51%. All treatment plans underwent quality review for contouring accuracy and dosimetric compliance. All treatment plans scored acceptable for tumor volume contouring and tumor volume dose-volume analysis. Only 4 (7%) scored unacceptable for organs at risk contouring and organs at risk dose-volume analysis. Treatment-related skin, fibrosis, and/or breast pain AEs were recorded as grade 1 in 64% and grade 2 in 7%, with only 1 (<2%) grade ≥3 and identified as grade 3 fibrosis of deep connective tissue. CONCLUSION: Partial-breast reirradiation with 3-dimensional conformal radiation therapy after second lumpectomy for patients experiencing in-breast failures after whole-breast irradiation is safe and feasible, with acceptable treatment quality achieved. Skin, fibrosis, and breast pain toxicity was acceptable, and grade 3 toxicity was rare.


Asunto(s)
Neoplasias de la Mama/radioterapia , Mama/efectos de la radiación , Carcinoma Intraductal no Infiltrante/radioterapia , Mastectomía Segmentaria , Recurrencia Local de Neoplasia/radioterapia , Traumatismos por Radiación/patología , Radioterapia Conformacional/efectos adversos , Reirradiación/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Femenino , Fibrosis/patología , Humanos , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/cirugía , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Estudios Prospectivos , Oncología por Radiación , Radioterapia Conformacional/métodos , Reoperación , Piel/patología , Piel/efectos de la radiación
14.
Brachytherapy ; 14(5): 613-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26092424

RESUMEN

PURPOSE: To present a novel method allowing fast volumetric optimization of tandem and ovoid high-dose-rate treatments and to quantify its benefits. METHODS AND MATERIALS: Twenty-seven CT-based treatment plans from 6 consecutive cervical cancer patients treated with four to five intracavitary tandem and ovoid insertions were used. Initial single-step optimized plans were manually optimized, approved, and delivered plans created with a goal to cover high-risk clinical target volume (HR-CTV) with D90 >90% and minimize rectum, bladder, and sigmoid D2cc. For the two-step optimized (TSO) plan, each single-step optimized plan was replanned adding a structure created from prescription isodose line to the existent physician delineated HR-CTV, rectum, bladder, and sigmoid. New, more rigorous dose-volume histogram constraints for the critical organs at risks (OARs) were used for the optimization. HR-CTV D90 and OAR D2ccs were evaluated in both plans. RESULTS: TSO plans had consistently smaller D2ccs for all three OARs while preserving HR-CTV D90. On plans with "excellent" CTV coverage, average D90 of 96% (91-102%), sigmoid, bladder, and rectum D2cc, respectively, reduced on average by 37% (16-73%), 28% (20-47%), and 27% (15-45%). Similar reductions were obtained on plans with "good" coverage, average D90 of 93% (90-99%). For plans with "inferior" coverage, average D90 of 81%, the coverage increased to 87% with concurrent D2cc reductions of 31%, 18%, and 11% for sigmoid, bladder, and rectum, respectively. CONCLUSIONS: The TSO can be added with minimal planning time increase but with the potential of dramatic and systematic reductions in OAR D2ccs and in some cases with concurrent increase in target dose coverage. These single-fraction modifications would be magnified over the course of four to five intracavitary insertions and may have real clinical implications in terms of decreasing both acute and late toxicities.


Asunto(s)
Braquiterapia/métodos , Carcinoma de Células Escamosas/radioterapia , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/prevención & control , Neoplasias del Cuello Uterino/radioterapia , Braquiterapia/efectos adversos , Carcinoma de Células Escamosas/diagnóstico por imagen , Colon Sigmoide/efectos de la radiación , Femenino , Humanos , Persona de Mediana Edad , Dosis de Radiación , Traumatismos por Radiación/etiología , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Recto/efectos de la radiación , Tomografía Computarizada por Rayos X , Vejiga Urinaria/efectos de la radiación , Neoplasias del Cuello Uterino/diagnóstico por imagen
15.
Int J Radiat Oncol Biol Phys ; 90(5): 1025-9, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25442036

RESUMEN

PURPOSE: To describe the long-term outcomes from a completed, multi-institutional phase 4 registry trial using the Contura multilumen balloon (CMLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer. METHODS AND MATERIALS: Three hundred forty-two evaluable patients were enrolled by 23 institutions between January 2008 and February 2011. All patients received 34 Gy in 10 fractions, delivered twice daily. Rigorous target coverage and normal tissue dose constraints were observed. RESULTS: The median follow-up time was 36 months (range, 1-54 months). For the entire patient cohort of 342 patients, 10 patients experienced an ipsilateral breast tumor recurrence (IBTR). Eight of these IBTR were classified as true recurrences/marginal miss (TRMM), and 2 were elsewhere failures (EF). Local recurrence-free survival was 97.8% at 3 years. For the entire cohort, 88% of patients had good to excellent overall cosmesis. The overall incidence of infection was 8.5%. Symptomatic seroma was reported in only 4.4% of patients. A separate analysis was performed to determine whether improved outcomes would be observed for patients treated at high-volume centers with extensive brachytherapy experience. Three IBTR were observed in this cohort, only 1 of which was classified as a TRMM. Local recurrence-free survival at high-volume centers was 98.1% at 3 years. Overall cosmetic outcome and toxicity were superior in patients treated at high-volume centers. In these patients, 95% had good to excellent overall cosmesis. Infection was observed in only 2.9% of patients, and symptomatic seroma was reported in only 1.9%. CONCLUSION: Use of the CMLB for APBI delivery is associated with acceptable long-term local control and toxicity. Local recurrence-free survival was 97.8% at 3 years. Significant (grade 3) toxicity was uncommon, and no grade 4 toxicity was observed. Treatment at high-volume centers was associated with decreased late toxicity.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Lobular/radioterapia , Recurrencia Local de Neoplasia , Braquiterapia/instrumentación , Neoplasias de la Mama/epidemiología , Instituciones Oncológicas , Carcinoma Ductal de Mama/epidemiología , Carcinoma Lobular/epidemiología , Catéteres , Supervivencia sin Enfermedad , Fraccionamiento de la Dosis de Radiación , Femenino , Estudios de Seguimiento , Hospitales de Alto Volumen , Humanos , Incidencia , Recurrencia Local de Neoplasia/epidemiología , Neoplasias Primarias Secundarias/epidemiología , Seroma/epidemiología , Resultado del Tratamiento
16.
Brachytherapy ; 13(5): 471-80, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25037911

RESUMEN

PURPOSE: This is a retrospective study in which we define multiple metrics for similarity and then inquire on the relationship between similarity and currently used dosimetric quantities describing preimplant and postimplant plans. METHODS AND MATERIALS: We analyzed a unique cohort of 94 consecutively performed prostate seed implant patients, associated with excellent dosimetric and clinical outcomes. For each patient, an ultrasound (US) preimplant and two CT postimplant (Day 0 and Day 30) studies were available. Measures for similarity were created and computed using feature vectors based on two classes of moments: first, invariant to rotation and translation, and the second polar-radius moments invariant to rotation, translation, and scaling. Both similarity measures were calibrated using controlled perturbations (random and systematic) of seed positions and contours in different size implants, thus producing meaningful numerical threshold values used in the clinical analysis. RESULTS: An important finding is that similarity, for both seed distributions and contours, improves significantly when scaling invariance is added to translation and rotation. No correlation between seed and contours similarity was found. In the setting of preplanned prostate seed implants using preloaded needles, based on our data, similarity between preimplant and postimplant plans does not correlate with either minimum dose to 90% of the volume of the prostate or analogous similarity metrics for prostate contours. CONCLUSIONS: We have developed novel tools and metrics, which will allow practitioners to better understand the relationship between preimplant and postimplant plans. Geometrical similarity between a preplan and an actual implant, although useful, does not seem to be necessary to achieve minimum dose to 90% of the volume of the prostate-good dosimetric implants.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Próstata/radioterapia , Humanos , Masculino , Modelos Estadísticos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Radiometría/métodos , Dosificación Radioterapéutica , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Ultrasonografía
18.
Int J Radiat Oncol Biol Phys ; 86(2): 264-9, 2013 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-23433798

RESUMEN

PURPOSE: Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. METHODS AND MATERIALS: Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥ 95% of the prescribed dose (PD) covering ≥ 95% of the target volume (TV); maximum skin dose ≤ 125% of the PD; maximum rib dose ≤ 145% of the PD; and V150 ≤50 cc and V200 ≤ 10 cc. RESULTS: Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P ≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. CONCLUSIONS: Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Catéteres , Braquiterapia/efectos adversos , Braquiterapia/métodos , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Dosificación Radioterapéutica , Carga Tumoral
19.
Brachytherapy ; 11(4): 292-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22464911

RESUMEN

PURPOSE: A Phase I/II protocol was conducted to examine the toxicity and efficacy of the combination of intensity-modulated radiation therapy (IMRT) with a single-fraction high-dose-rate (HDR) brachytherapy implant. METHODS AND MATERIALS: From 2001 through 2006, 26 consecutive patients were treated on the trial. The primary objective was to demonstrate a high rate of completion without experiencing a treatment-limiting toxicity. Eligibility was limited to patients with T stage ≤2b, prostate-specific antigen (PSA) ≤20, and Gleason score ≤7. Treatment began with a single HDR fraction of 6Gy to the entire prostate and 9Gy to the peripheral zone, followed by IMRT optimized to deliver in 28 fractions with a normalized total dose of 70Gy. Patients received 50.4Gy to the pelvic lymph node. The prostate dose (IMRT and HDR) resulted in an average biologic equivalent dose >128Gy (α/ß=3). Patients whose pretreatment PSA was ≥10ng/mL, Gleason score 7, or stage ≥T2b received short-term androgen ablation. RESULTS: Median followup was 53 months (9-68 months). There were no biochemical failures by either the American Society of Therapeutic Radiology and Oncology or the Phoenix definitions. The median nadir PSA was 0.32ng/mL. All the 26 patients completed the treatment as prescribed. The rate of Grade 3 late genitourinary toxicity was 3.8% consisting of a urethral stricture. There was no other Grade 3 or 4 genitourinary or gastrointestinal toxicities. CONCLUSIONS: Single-fraction HDR-boosted IMRT is a safe effective method of dose escalation for localized prostate cancer.


Asunto(s)
Adenocarcinoma/radioterapia , Braquiterapia/efectos adversos , Neoplasias de la Próstata/radioterapia , Traumatismos por Radiación/etiología , Radioterapia Conformacional/efectos adversos , Adenocarcinoma/complicaciones , Adenocarcinoma/patología , Anciano , Anciano de 80 o más Años , Braquiterapia/métodos , Terapia Combinada , Fraccionamiento de la Dosis de Radiación , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos , Neoplasias de la Próstata/complicaciones , Neoplasias de la Próstata/patología , Traumatismos por Radiación/diagnóstico , Radioterapia Conformacional/métodos , Resultado del Tratamiento
20.
Cancer ; 118(8): 1962-70, 2012 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-22009259

RESUMEN

In accelerated partial breast irradiation (APBI), the most commonly used fractionation schemes include 340 or 385 centigrays delivered in a twice daily administration. A further progression of the APBI literature has been the recent interest in extremely short courses of adjuvant radiotherapy, usually delivered by intraoperative radiotherapy techniques. This newer area of single-fraction radiotherapy approaches remains highly contentious. In particular, the recently reported TARGIT trial has been the subject of both praise and scorn, and a critical examination of the trial data and the underlying hypotheses is warranted. Short-term outcomes of the related Italian ELIOT approach have also been reported. Although the assumptions of linear quadratic formalism are likely to hold true in the range of 2 to 8 grays, equating different schedules beyond this range is problematic. A major problem of current single-fraction approaches is that the treatment doses are chosen empirically, or are based on tolerability, or on the physical dose delivery characteristics of the chosen technology rather than radiobiological rationale. This review article summarizes the current data on ultrashort courses of adjuvant breast radiotherapy and highlights both the promise and the potential pitfalls of the abbreviated treatment.


Asunto(s)
Neoplasias de la Mama/radioterapia , Dosificación Radioterapéutica , Radioterapia Adyuvante/métodos , Neoplasias de la Mama/cirugía , Terapia Combinada , Fraccionamiento de la Dosis de Radiación , Electrones/uso terapéutico , Femenino , Humanos , Periodo Intraoperatorio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...