Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Front Cardiovasc Med ; 11: 1384222, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38911518

RESUMEN

Introduction: Intravascular imaging, especially optical coherence tomography (OCT), has significantly improved percutaneous coronary intervention (PCI), yet its routine clinical application faces challenges. This case series introduces the Gentuity® High-Frequency Optical Coherence Tomography (HF-OCT), a novel device designed to enhance intracoronary imaging with a significantly faster pullback and smaller catheter size, potentially offering enhanced navigability in complex lesions. We aimed to assess the image quality of Gentuity® HF-OCT in complex vessel conditions, as well as presenting a case series to illustrate the application of the device in various clinical scenarios. Methods: In this case series, we included all patients who underwent intracoronary HF-OCT imaging at our center. The primary endpoint was image quality assessed by clear image length (CIL). Image quality was assessed in relation to (1) lesion severity assessed by minimum lumen area (MLA); (2) vessel size, differentiating between larger (diameter ≥ 4 mm) and smaller vessel segments; (3) pre- vs. post-PCI conditions, and (4) vessel tortuosity, categorized into none, moderate, and severe. Results: Twenty-four HF-OCT runs from 14 patients were included. No significant differences in CIL were observed across lesion severity terciles (p = 0.449), between small and large vessel segments [mean CIL% difference 1.3%; confidence interval (CI), -9.3 to 11.8; p = 0.802], and pre- vs. post-PCI conditions (mean CIL difference -3.9 mm; CI, -14.0 to 6.1; p = 0.373). Vessel tortuosity significantly impacted image quality, with clear reductions in CIL observed in cases of moderate (74.8; CI, 73.5 to 76.0; vs. 63.9; CI, 56.2 to 71.5; p = 0.043) and severe tortuosity (74.8; CI, 73.5 to 76.0; vs. 65.0; CI, 62.1 to 67.9; p = 0.002) compared to vessels with no tortuosity. Overall, the HF-OCT demonstrated excellent catheter deliverability and crossability, with very satisfactory image quality and no significant adverse events. Conclusion: The Gentuity® HF-OCT is a new OCT device capable of navigating both small- and large-diameter vessels, with similar image quality, but vessel tortuosity seems to have an impact on image quality. It appears to be as usable as conventional OCT for pre-PCI diagnosis and OCT-guided PCI, potentially bringing additional benefits in terms of deliverability, lesion crossover and ease of use in routine clinical practice.

2.
Catheter Cardiovasc Interv ; 103(3): 417-424, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38297989

RESUMEN

BACKGROUND: Optimal stent deployment in left main (LM) bifurcation is paramount, and incomplete stent apposition may cause major adverse cardiac events (MACE). Bench studies show that the proximal optimization technique (POT) provides the best stent apposition. AIMS: We aimed to investigate the impact of POT on clinical outcomes in patients treated for unprotected LM (ULM) disease at our institution. METHODS: We identified 162 patients who underwent percutaneous coronary intervention (PCI) for ULM coronary disease in the Cardio-FR database. Out of these, 99 (61%) had undergone POT, while 63 patients were treated without POT. The primary outcome was the bifurcation-oriented composite endpoint (BOCE) of cardiac death, target-bifurcation myocardial infarction and target-bifurcation revascularization at maximal follow-up. RESULTS: Mean age was 76 years, and 69% presented with acute coronary syndrome. Mean follow-up was 2.25 years (822 days). The BOCE occurred in 43 (27%) of which 20 (20%) in the POT group and 23 (37%) in the no-POT group (p = 0.009). Cardiac death occurred in 15 (15%) patients in the POT- and 17 (27%) in no-POT group (p = 0.26). Target bifurcation revascularization occurred in 4 (4%) patients in the POT- and 6 (10%) patients in the no-POT group (p = 0.19). POT In the multivariate analysis, POT was the strongest parameter and was associated with BOCE, cardiac death, occurrence of any revascularization and all-cause mortality. CONCLUSION: The POT improves clinical outcomes. These findings strongly support the systematic use of POT in patients undergoing ULM-PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Resultado del Tratamiento , Muerte , Angiografía Coronaria , Factores de Riesgo
3.
Front Cardiovasc Med ; 10: 1270782, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38111894

RESUMEN

The chimney technique has been utilized to minimize the risk of coronary artery obstruction during valve-in-valve procedures. Here, we present a case involving an 89-year-old female patient with low coronary ostia, severe aortic regurgitation, and intractable heart decompensation caused by degenerated aortic bioprosthesis. The patient underwent a successful transcatheter aortic valve implantation procedure using the chimney technique in both coronary ostia.

4.
BMC Infect Dis ; 23(1): 81, 2023 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-36750785

RESUMEN

BACKGROUND: Mycoplasma salivarium is part of our commensal oral flora and readily resides in dental plaque. Although considered indolent, few case reports have documented its pathogenic potential in humans. To this day no case of Mycoplasma salivarium infectious endocarditis has ever been described. CASE PRESENTATION: Our report describes a challenging case of Mycoplasma salivarium endocarditis, with a patient presenting with oligoarticular joint swelling, and later on in the course of his disease developed signs of right-sided heart failure. The diagnosis was initially mistaken for septic gonarthritis and was later established on the basis of echocardiography and eubacterial PCR of joint fluid. CONCLUSION: This report describes a first documented case of Mycoplasma salivarium culture negative endocarditis that was successfully treated with targeted antimicrobial therapy. Specific antimicrobial therapy targeting Mycoplasma spp, lead to clinical improvement, with radiological regression of the lesion and the resolution of the serum inflammation biomarkers.


Asunto(s)
Endocarditis , Infecciones por Mycoplasma , Mycoplasma salivarium , Humanos , Válvula Mitral/patología , Infecciones por Mycoplasma/microbiología , Boca/microbiología
5.
Open Heart ; 9(2)2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36539292

RESUMEN

AIM: Percutaneous coronary interventions require an arterial approach and administration of antithrombotic drugs. This may lead to bleeding complications. The aim of this study was to test whether "The Secret" - a pagan prayer - is effective in reducing post-interventional bleeding. DESIGN: Randomised controlled trial. SETTING: Monocentric, tertiary care centre. PARTICIPANTS: From January to July 2022, 200 patients (aged >18 years) undergoing elective coronary angiography were included in the study. INTERVENTION: The intervention group received "The Secret" in addition to the normal procedure. The control group was treated according to standard practice. MAIN OUTCOME MEASURES: The primary outcome was the rate of in-hospital bleeding according to the Bleeding Academic Research Consortium (BARC) consensus definition. RESULTS: The rate of bleeding was similar in both groups ("The Secret" group vs control group) with 16% versus 14% (p=0.69) of BARC 1, 12% versus 13% (p=0.81) of BARC 2, and 0% versus 0% of BARC 3 and 5 (p=1.00). Most (76%) of the participants believed that "The Secret" would be efficient in preventing bleeding. CONCLUSIONS: This study demonstrates no effect on bleeding after percutaneous coronary procedures. A large majority of our study population believe that "The Secret" can have a positive effect on their hospital care.


Asunto(s)
Hemorragia , Intervención Coronaria Percutánea , Humanos , Hemorragia/etiología , Hemorragia/prevención & control , Hemorragia/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Medicina Tradicional
6.
Blood Press Monit ; 27(6): 402-407, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35950543

RESUMEN

AIMS: The purpose of this study is to evaluate the accuracy of the Senbiosys device in measuring blood pressure (BP) by photoplethysmography (PPG) in patients undergoing coronary angiography. METHODS: This is a substudy within the Senbiosys trial, which is a prospective, single-arm, single-center study, evaluating the accuracy of BP estimation of the Senbiosys device compared to invasive BP. Patients referred for coronary angiography underwent invasive BP measurement and simultaneously wore the Senbiosys ring. SBP and DBP estimations measured by the Senbiosys device were compared with invasive measurements. RESULTS: A total of 25 patients were included. Overall, 708 epochs with adequate PPG signal belonging to 17 patients were analyzed. A total of 84% of the SBP estimates and 99% of the DBP estimates have an absolute error of less than 10 mmHg compared with the invasive measurements. Mean difference was 2.3 ± 7.0 mmHg and 0.5 ± 3.5 mmHg for SBP and DBP, respectively. CONCLUSION: The Senbiosys device is accurate enough to determine BP in a selected population undergoing coronary angiography.


Asunto(s)
Determinación de la Presión Sanguínea , Dispositivos Electrónicos Vestibles , Humanos , Presión Sanguínea/fisiología , Angiografía Coronaria , Estudios Prospectivos , Fotopletismografía
7.
Catheter Cardiovasc Interv ; 99(3): 523-532, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34173699

RESUMEN

AIMS: To compare 5-year angiographic, optical coherence tomography (OCT), and clinical outcomes between patients treated with bioresorbable vascular scaffolds (BVS) and drug-eluting stents (DES). METHODS: The EverBio-2 trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) was a single-center, assessor-blinded, randomized controlled trial in which 240 patients were randomly allocated (1:1:1) to BVS, everolimus-eluting (EES) or biolimus-eluting (BES) DES. Clinical follow-up was scheduled up to 5 years. All patients, alive and who did not have repeat revascularization of the target lesion during follow-up were asked to return for angiographic follow-up at 5 years. RESULTS: Five-year angiographic follow-up was completed in 122 patients (51%) and OCT analysis was performed in 86 (36%) patients. In-stent late lumen loss was similar in both groups with 0.50 ± 0.38 mm in BVS versus 0.58 ± 0.36 mm in EES/BES, p = 0.20. Clinical follow-up was complete in 232 patients (97%) at 5 years. The rate of the device-oriented endpoint was 22% in the BVS and 18% in the EES/BES group (p = 0.49). The patient-oriented composite endpoint occurred in 40% of BVS- and 43% of EES/BES-treated patients (p = 0.72) at 5 years. No acute coronary syndrome due to stent thrombosis was detected after 2 years. Complete BVS strut resorption was observed at 5 years in the OCT subgroup. CONCLUSION: Five-year clinical outcomes were similar between BVS and DES patients as well as angiographic outcomes in a selected subgroup. However, a definitive conclusion cannot be drawn because the EverBio-2 trial was not powered for clinical and angiographic endpoints at 5 years of follow-up.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Stents Liberadores de Fármacos/efectos adversos , Everolimus/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sirolimus/efectos adversos , Stents , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento
8.
Front Cardiovasc Med ; 8: 620354, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34926595

RESUMEN

Background: The Academic Research Consortium have identified a set of major and minor risk factors in order to standardize the definition of a High Bleeding Risk (ACR-HBR). Aims: The aim of this study is to stratify the bleeding risk in patients included in the Cardio-Fribourg registry, according to the Academic Research Consortium for High Bleeding Risk (ACR-HBR) definition, and to report ischemic and hemorrhagic events at 2-year of clinical follow-up. Methods: Between 2015 and 2017, consecutive patients undergoing percutaneous coronary intervention were prospectively included in the Cardio-Fribourg registry. Patients were considered high (HBR) or low (LBR) bleeding risk depending on the ARC-HBR definition. Primary endpoints were hierarchical major bleeding events as defined by the Bleeding Academic Research Consortium (BARC) grade 3-5, and ARC patient-oriented major adverse cardiac events (POCE) at 2-year follow-up. Results: Follow-up was complete in 1,080 patients. There were 354 patients in the HBR group (32.7%) and 726 patients in the low-bleeding risk (LBR) group (67.2%). At 2-year follow-up, cumulative BARC 3-5 bleedings were higher in HBR (10.5%) compared to LBR patients (1.5%, p < 0.01) and the impact of HBR risk factors was incremental. At 2-year follow-up, POCE were more frequent in HBR (27.4%) compared to LBR group (18.2%, <0.01). Overall mortality was higher in HBR (14.0%) vs. LBR (2.9%, p < 0.01). Conclusions: ARC-HBR criteria appropriately identified a population at a higher risk of bleeding after percutaneous coronary intervention. An increased risk of bleeding is also associated with an increased risk of ischemic events at 2-year follow-up.

9.
Front Cardiovasc Med ; 8: 589426, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34660705

RESUMEN

Background: The Academic Research Consortium has identified a set of major and minor risk factors in order to standardize the definition of a high bleeding risk (ACR-HBR). Oral anticoagulation is a major criterion frequently observed. Aims: The objective of this study is to quantify the risk of bleeding in patients on oral anticoagulation with at least one additional major ACR-HBR criteria in the Cardio-Fribourg Registry. Methods: Between 2015 and 2017, consecutive patients undergoing percutaneous coronary intervention were prospectively included in the Cardio-Fribourg registry. The study population included patients with ongoing long-term oral anticoagulation (OAC) and planned to receive triple antithrombotic therapy. Patients were divided in two groups: patients on OAC with at least one additional major ACR-HBR criteria vs. patients on OAC without additional major ACR-HBR criteria. The primary endpoint was any bleeding during the 24-month follow-up. Secondary bleeding endpoint was defined as Bleeding Academic Research Classification (BARC) ≥3. Results: Follow-up was completed in 142 patients at high bleeding risk on OAC, of which 33 (23%) had at least one additional major ACR-HBR criteria. The rate of the primary endpoint was 55% in patients on OAC with at least one additional ACR-HBR criteria compared with 14% in patients on OAC without additional ACR-HBR criteria (hazard ratio, 3.88; 95%CI, 1.85-8.14; p < 0.01). Patients with additional major ACR-HBR criteria also experienced significantly higher rates of BARC ≥ 3 bleedings (39% at 24 months). Conclusion: The presence of at least one additional ACR-HBR criterion identifies patients on OAC who are at very high risk of bleeding after percutaneous coronary intervention.

10.
JACC Cardiovasc Interv ; 14(9): 952-960, 2021 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-33865734

RESUMEN

OBJECTIVES: The aim of this study was to investigate age-related outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) as assessed in a nationwide, prospective, multicenter cohort study. BACKGROUND: TAVR is the preferred treatment for elderly patients with severe aortic stenosis and is expanding into lower age groups. METHODS: Data from the SwissTAVI Registry were analyzed. Clinical outcomes were compared between patients 70 years of age or younger (n = 324), 70 to 79 years of age (n = 1,913), 80 to 89 years of age (n = 4,353), and older than 90 years of age (n = 507). Observed deaths were correlated with expected deaths in the general Swiss population using standardized mortality ratios. RESULTS: Between February 2011 and June 2018, 7,097 patients (mean age 82.0 ± 6.4 years, 49.6% women) underwent TAVR at 15 hospitals in Switzerland. Procedural characteristics were similar; however, older patients more often had discharge to the referring hospital or a rehabilitation facility after TAVR. Using adjusted analyses, a linear trend for mortality (30-day adjusted hazard ratio [HRadj]: 1.45; 95% confidence interval [CI]: 1.18 to 1.77; 1-year HRadj: 1.12; 95% CI: 1.01 to 1.24), cerebrovascular accidents (30-day HRadj: 1.35; 95% CI: 1.09 to 1.66; 1-year HRadj: 1.21; 95% CI: 1.02 to 1.45), and pacemaker implantation (30-day HRadj: 1.23; 95% CI: 1.12 to 1.34; 1-year HRadj: 1.19; 95% CI: 1.09 to 1.30) was observed with increasing age. Furthermore, standardized mortality ratios were 12.63 (95% CI: 9.06 to 17.58), 4.09 (95% CI: 3.56 to 4.74), 1.63 (95% CI: 1.50 to 1.78), and 0.93 (95% CI: 0.76 to 1.14) for TAVR patients in relation to the Swiss population <70, 70 to 79, 80 to 89 and ≥90 years of age, respectively. CONCLUSIONS: Increasing age is associated with a linear trend for mortality, stroke, and pacemaker implantation during early and longer-term follow-up after TAVR. Standardized mortality ratios were higher for TAVR patients younger than 90 years of age compared with expected rates of mortality in an age- and sex-matched Swiss population. (SWISS TAVI Registry; NCT01368250).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Femenino , Humanos , Masculino , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
Rev Med Suisse ; 17(728): 418-423, 2021 Mar 03.
Artículo en Francés | MEDLINE | ID: mdl-33656293

RESUMEN

SARS-CoV-2 affects the cardiovascular system triggering a proinflammatory response which results in direct and indirect myocardial injury. The objective of this article is to describe the underlying mechanisms and clinical implications.


Le système cardiovasculaire est largement affecté par le coronavirus SARS-CoV-2. La maladie à coronavirus 2019 (Covid-19) peut déclencher une réaction inflammatoire intense, responsable de lésions myocardiques directes et indirectes chez environ un quart des patients hospitalisés. L'objectif de cet article est de décrire les mécanismes sous-jacents aux atteintes cardiovasculaires et de discuter les potentielles implications cliniques.


Asunto(s)
COVID-19 , Enfermedades Cardiovasculares , Humanos , SARS-CoV-2
12.
Swiss Med Wkly ; 150: w20368, 2020 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-33211904

RESUMEN

Increased age impacts the first medical contact to revascularisation delay in patients with STEMI. Patients with shorter treatment delays (<90 minutes after first medical contact) have significantly lower major adverse cardiac events rates at 3 years.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/cirugía , Tiempo de Tratamiento , Resultado del Tratamiento
13.
JACC Case Rep ; 2(3): 497-498, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34317274

RESUMEN

Spontaneous recanalized coronary thrombi (SRCT), a rare and under-diagnosed entity, are old thrombus formations characterized by multiple communicating channels. We report the case of a 72-year-old female patient who presented with SRCT in the context of polycythemia vera. Optical coherence tomography (OCT) is the diagnostic method of choice. (Level of Difficulty: Intermediate.).

14.
Eur Heart J Case Rep ; 4(5): 1-4, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33426462

RESUMEN

BACKGROUND: Giant coronary artery aneurysms (CAAs) are rare and treatment strategies various, especially in the setting of a concomitant abdominal aortic aneurysm (AAA) which needs urgent repair. CASE SUMMARY: A 78-year-old Caucasian male was admitted for evaluation of a rapidly expanding AAA. In addition, computed tomography angiography revealed a 5 x 4 cm giant aneurysm of the right coronary artery. After interdisciplinary discussion, the patient underwent aorto-bi-iliac bypass grafting first. In a second step, CAA was successfully excluded and coronary artery bypass grafting of the right coronary artery was performed. DISCUSSION: Treatment strategy of CAA and timing of non-cardiac surgery is challenging. In order to minimize the overall risk of rupture interdisciplinary discussion is crucial. In our case, aorto-bi-iliac bypass grafting was safely performed, and the patient underwent successful CAA excision in a second step.

15.
Open Heart ; 5(1): e000624, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29344373

RESUMEN

Aims: To compare endothelium-dependent vasomotor function and vascular healing 15 months after implantation of two new-generation drug-eluting stents and biovascular scaffolds (BVS). Methods and results: A total of 28 patients previously treated with a SYNERGY stent (bioabsorbable polymer everolimus-eluting stents (BP-EES)), a PROMUS stent (persistent polymer everolimus-eluting stents (PP-EES)) or an ABSORB (BVS) underwent control coronary angiography, 15 months after implantation, coupled with optical coherence tomography imaging and supine bicycle exercise. Intracoronary nitroglycerin was administered after exercise testing. Coronary vasomotor response was assessed using quantitative coronary angiography at rest, during supine bicycle exercise and after nitroglycerin. The primary end point was the percent change in mean lumen diameter compared with baseline. Secondary end points were strut coverage and apposition.There were no significant differences in vasomotor response between the three treatment groups. Patients with PP-EES showed significant vasoconstriction of the proximal peristent segment at maximum exercise (P=0.02). BP-EES (2.7%, 95% CI 0 to 5.5) and BVS (3.2%, 95% CI 0 to 6.7) showed less uncovered struts than PP-EES (12.1%, 95% CI 2.9 to 21.3, P=0.02 and 0.09, respectively). Complete strut apposition was more frequently seen with BP-EES (99.6%, 95% CI 99.2 to 100) than with BVS (98.9%, 95% CI 98.2 to 99.6, P=0.04) or PP-EES (95.0%, 95% CI 91.6 to 98.5, P=0.001). Conclusion: BVS and thin strut BP-EES have a reassuring vasomotion profile, suggesting minimal endothelial dysfunction 15 months after implantation.

16.
JACC Cardiovasc Interv ; 10(12): 1215-1221, 2017 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-28579236

RESUMEN

OBJECTIVES: This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. BACKGROUND: Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. METHODS: The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. RESULTS: Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). CONCLUSIONS: The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/análogos & derivados , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
17.
Int J Cardiol ; 243: 121-125, 2017 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-28576627

RESUMEN

BACKGROUND: Data from randomized controlled trials have shown that the ABSORB BVS is non-inferior to Cobalt Chromium everolimus-eluting stents at 2years. METHODS & RESULTS: The EVERBIO II trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) is a single-center, assessor-blind, randomized controlled trial enrolling 240 patients with an allocation ration of 1:1:1 conducted at University and Hospital Fribourg, Switzerland. The studied devices were an everolimus-eluting persistent polymer stent (EES), a biolimus-eluting stent with bioabsorbable polymer (BES) and a fully bioresorbable vascular scaffold (BVS). Clinical end points collected at 9months, 12months, and 2years, were academic research consortium defined composites, device thrombosis and target-vessel revascularization. Clinical follow-up at 2years was available in 96% (N=77) of patients in the EES group, in 100% (N=80) in the BES and 99% (N=77) in the BVS group. The device-oriented composite end point of cardiac death, target-vessel myocardial infarction and target-lesion revascularization occurred in 13 (16%) patients treated with EES, in 7 (9%) patients treated with BES and in 16 (21%) patients treated with BVS. There was no significant difference when the metallic stents were compared to the BVS (p=0.12). There was one late scaffold thrombosis throughout the trial in the BVS group, and no definite stent thrombosis in either EES or BES treated patients. CONCLUSIONS: The current analysis shows no significant differences with regard to clinical outcomes at 2years between BVS and the best-in-class metallic DES. Event rates were numerically higher in BVS-treated patients. However, when BVS were compared to BES alone, the occurrence of device related adverse events was significantly increased.


Asunto(s)
Implantes Absorbibles/tendencias , Stents Liberadores de Fármacos/tendencias , Everolimus/administración & dosificación , Fibrinolíticos/administración & dosificación , Sirolimus/análogos & derivados , Andamios del Tejido/tendencias , Anciano , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
18.
Arch Cardiovasc Dis ; 110(6-7): 389-394, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28433509

RESUMEN

BACKGROUND: Transcarotid access is an alternative route for transcutaneous aortic valve implantation (TAVI) in patients with impossible transfemoral access. AIMS: We evaluated the safety, effectiveness and early and late clinical outcomes of CoreValve® implantation via the common carotid artery. METHODS: Eighteen patients (10 men, 8 women; mean age 84±5 years) at high surgical risk (mean EuroSCORE II 16±13%) with significant peripheral artery disease underwent TAVI via common carotid artery access under general anaesthesia. Mean aortic valve area was 0.64±0.13cm2 (0.36±0.07cm2/m2). RESULTS: At a mean follow-up of 605±352 days, two patients (11%) had died in hospital, on days 6 and 20, as a result of sepsis with multiorgan failure (n=1) or pneumonia (n=1). There were no perioperative deaths, myocardial infarctions or strokes. Perioperative prosthesis embolization occurred in one patient (6%), requiring implantation of a second valve. In-hospital complications occurred in four patients (23%): blood transfusion for transient significant bleeding at the access site in one patient (6%); permanent pacemaker implantation in two patients (11%); and pericardial drainage in one patient (6%). The rate of event-free in-hospital stay was 66%. Post-procedural echocardiography showed very good haemodynamic performance, with a mean gradient of 8±3mmHg. Moderate paravalvular leak was present in one patient (6%). Mean intensive care unit stay was 48±31h; mean in-hospital stay was 7±3 days. CONCLUSION: TAVI performed by transcarotid access in this small series of severely ill patients was associated with a low incidence of complications, which were associated with the procedure itself rather than the access route.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Arteria Carótida Común , Enfermedad Arterial Periférica/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Arteria Carótida Común/diagnóstico por imagen , Supervivencia sin Enfermedad , Estudios de Factibilidad , Femenino , Arteria Femoral/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Hemodinámica , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
19.
Am J Cardiol ; 118(2): 188-94, 2016 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-27239022

RESUMEN

We sought to compare operator radiation exposure during procedures using right femoral access (RFA), right radial access (RRA), and left radial access (LRA) during coronary angiography (CA) and percutaneous coronary intervention (PCI). Because of an increased incidence of long-term malignancy in interventional cardiologists, operator radiation exposure is of rising concern. This prospective study included all consecutive patients who underwent elective or emergency CA ± PCI from September 2014 to March 2015. The primary end point was operator radiation exposure, quantified as the ratio of operator cumulative dose (CD) and patient radiation reported as dose-area product (DAP) (CD/DAP). Secondary end points included CD, DAP, and fluoroscopy time (FT). Overall 830 procedures (457 CA [55%] and 373 PCI [45%]) were performed, 455 (55%) through RFA, 272 (33%) through RRA, and 103 (12%) through LRA. The CD/DAP was lower in RFA (0.09 µSv/Gycm(2) [0.02 to 0.20]) compared with RRA (0.47 µSv/Gycm(2) [0.25 to 0.75], p <0.001). The LRA showed lower CD/DAP compared with RRA (p <0.001). CD was significantly lower in RFA (3 µSv [1 to 7]) compared with RRA (12 µSv [6 to 29], p <0.001). The LRA showed lower CD compared with RRA (p <0.001). There were no significant differences in DAP among the 3 access sites. FT was similar for the 3 groups (RFA 7 ± 7, RRA 5 ± 5, LRA 6 ± 5 minutes, RFA vs RRA: p = 1, RFA vs LRA: p = 0.16, RRA vs LRA: p = 0.52). In conclusion, the use of RFA during CA ± PCI is associated with significantly lower operator radiation exposure compared with RRA. LRA is associated with significantly lower operator radiation exposure compared with RRA.


Asunto(s)
Cateterismo Cardíaco , Cardiólogos , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Exposición Profesional/estadística & datos numéricos , Intervención Coronaria Percutánea , Dosis de Radiación , Exposición a la Radiación/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Vasos Coronarios/cirugía , Femenino , Arteria Femoral , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Arteria Radial , Radiometría , Factores de Tiempo
20.
Open Heart ; 3(1): e000373, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26835145

RESUMEN

BACKGROUND: Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. OBJECTIVES: To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. DESIGN: This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. RESULTS: Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. CONCLUSIONS: Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...