Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Arthroscopy ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38697328

RESUMEN

PURPOSE: To create a metric for evaluating the degree of laterality of the patella's entry into the trochlea, the entry point-trochlear groove (EP-TG) angle, and to evaluate if this laterality is associated with recurrent patella instability. METHODS: The time frame of the study was January 2020 to February 2023. The inclusion criteria were patients treated by the senior author (J.P.F.) (with the exception of 2 patients who were treated by another provider at the institution who was aware of the study) who have been diagnosed with recurrent atraumatic patellar dislocations. Controls without knee pathology were selected from the New Mexico Decedent Imaging Database (NMDID). Simpleware ScanIP was used to create 3-dimensional (3D) models of the distal femurs from computed tomography scans. Anteroposterior images of these 3D models were uploaded to a custom EP-TG angle measuring tool. Three measurers used the tool to measure the EP-TG angle of the distal femurs. RESULTS: Twenty-eight patients were included for the recurrent dislocator group. Twenty-four decedents from the NMDID were selected for the control group, each with a left or right knee chosen randomly for measurement. A 1-sided Mann-Whitney U test, used to evaluate whether the recurrent dislocators had higher EP-TG angle values, yielded a P value <.001, demonstrating a high level of significance. A Bayesian mixed-effect model, used to determine how different the EP-TG angles are between the 2 groups, gave a posterior predictive interval of [11.93°, 19.12°] for the EP-TG angle shift of dislocators. The intraclass correlation coefficient was 0.648. CONCLUSIONS: The morphologic entry point of the patella into the proximal trochlea is more lateral in recurrent patella dislocators than in controls. This increased laterality can be measured by the EP-TG angle, which may be useful information for optimizing treatment of recurrent patella instability. LEVEL OF EVIDENCE: Level III, case control study.

2.
Int Orthop ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767711

RESUMEN

PURPOSE: Concurrent use of minus heads with tapered stems in total hip arthroplasty (THA) decreases the prosthetic range of motion (pROM). Three-dimensional preoperative templating can simulate the location of the impingement by taking the hip through a virtual pROM. This enables surgeons to simulate how modifying the type of implant, orientation, and position influences impingement. We hypothesized that CT-based modeling would result in a decrease in the pROM, thereby increasing the risk of impingement when minus heads are used. METHODS: Forty-three patients who underwent robotic-assisted primary THAs were included. Prosthetic head diameter (32/36-mm) and head length (minus/zero/plus) were the predictors. Maximum external rotation at full hip extension and internal rotation at 90° and 100° of flexion prior to prosthetic impingement were the outcome variables. A CT-based preoperative planning software was used for pROM estimation and impingement detection. RESULTS: Significant decreases in pROM were found for both head diameters as the head length decreased and was more pronounced in external rotation during full hip extension (changes of 2.8-3.4° for the 32-mm head and 1.6-2.8° for the 36-mm head (p = 0.00011)). The magnitude of loss in pROM when using a minus head was larger than the gain provided by a plus head in tapered stems (p < 0.0001). CONCLUSION: Head length affects the offset and pROM. When the use of minus heads or smaller heads is indicated, 3D preoperative templating for assessing postoperative pROM and impingement provides surgeons with options to consider alternate surgical plans offering additional assurance and protection from dislocation.

3.
Injury ; 55(6): 111532, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38614015

RESUMEN

BACKGROUND: Fixation of sustentaculum tali fractures is important to maintain the biomechanical function of the subtalar joint. A common method of fixation is securing the sustentacular fragment by way of a laterally based locking plate (LP). A medial approach with a single screw (MS) has been proposed as an alternative method of fixation. METHODS: Five pairs of formalin-preserved cadaveric ankles with the subtalar joint and interosseous ligaments intact ("osseous cadavers") and four pairs of fresh-frozen cadaveric ankles with soft-tissue preserved dissected from mid-tibia down ("soft tissue cadavers") were used in the study. The left ankle was randomly assigned to one of the two fixation methods (LP or MS), while the right ankle was the opposite. These same steps for fixation were repeated for six synthetic ankle models. All models were loaded with a body mass of 80 kg. Statistical differences between LP and MS stiffness were determined using a paired t-test in cadavers and un-paired t-tests in synthetic ankles. RESULTS: For osseous cadaveric ankles, LP demonstrated a mean stiffness of 232.95(SD: 59.96) N/mm, while MS was 239.72(SD:131.09) N/mm (p = 0.9293). For soft tissue cadaveric ankles, LP mean stiffness was 133.58(SD:37.84) N/mm, while MS was 134.88(SD:20.75) N/mm (p = 0.9578). For synthetic ankles, LP mean stiffness was 220.40(SD:81.93) N/mm, while MS was 261.50(SD:100.21) N/mm (p = 0.6116). CONCLUSIONS: Across all three models, there was no significant difference between LP and MS methods. Retrospective observational studies are recommended to assess patient outcomes from each of the methods.


Asunto(s)
Placas Óseas , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Articulación Talocalcánea/cirugía , Articulación Talocalcánea/fisiopatología , Astrágalo/cirugía , Astrágalo/lesiones , Fracturas de Tobillo/cirugía , Fracturas de Tobillo/fisiopatología , Masculino
4.
Cureus ; 16(2): e55136, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38558586

RESUMEN

INTRODUCTION: The selection of the most optimal fixation method for fractures of the distal femur, whether intramedullary nail (NL), lateral locking plate (PL), or nail/plate (NP) is not always clear. This study retrospectively evaluates surgical patients with distal femur fractures and introduces a pilot study using cluster analysis to identify the most optimal fracture fixation method for a given fracture type. METHODS: This is a retrospective cohort study of patients 18 years and older with an isolated distal femur fracture who presented to our Level-1 trauma center between January 1, 2012, and December 31, 2022, and obtained NL, PL, or NP implants. Patients with polytrauma and those without at least six months of follow-up were excluded. A chart review was used to obtain demographics, fracture classification, fixation method, and postoperative complications. A cluster analysis was performed. The following factors were used to determine a successful outcome: ambulatory status pre-injury and 6-12 months postoperatively, infection, non-union, mortality, and implant failure. RESULTS: A total of 169 patients met inclusion criteria. No statistically significant association between the fracture classification and fixation type with overall outcome was found. However, patients treated with an NP (n = 14) had a success rate of 92.9% vs only a 68.1% success rate in those treated with a PL (n = 116) (p = 0.106). The most notable findings in the cluster analysis (15 total clusters) included transverse extraarticular fractures demonstrating 100% success if treated with NP (n = 6), 50% success with NL (n=2), and 78.57% success with PL fixation (n=14). NP constructs in complete articular fractures demonstrated success in 100% of patients (n = 5), whereas 77.78% of patients treated with NL (n = 9) and 61.36% of those treated with PL (n = 44). CONCLUSIONS: Plate fixation was the predominant fixation method used for distal third femur fractures regardless of fracture classification. However, NP constructs trended towards improved success rates, especially in complete intraarticular and transverse extraarticular fractures, suggesting the potential benefit of additional fixation with these fractures. Cluster analysis provided a heuristic way of creating patient profiles in patients with distal third femur fractures. However, a larger cohort study is needed to corroborate these findings to ultimately develop a clinical decision-making tool that also accounts for patient specific characteristics.

5.
3D Print Med ; 10(1): 10, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38564090

RESUMEN

BACKGROUND: Femoral head avascular necrosis (AVN), or death of femoral head tissue due to a lack of blood supply, is a leading cause of total hip replacement for non-geriatric patients. Core decompression (CD) is an effective treatment to re-establish blood flow for patients with AVN. Techniques aimed at improving its efficacy are an area of active research. We propose the use of 3D printed drill guides to accurately guide therapeutic devices for CD. METHODS: Using femur sawbones, image processing software, and 3D modeling software, we created a custom-built device with pre-determined drill trajectories and tested the feasibility of the 3D printed drill guides for CD. A fellowship trained orthopedic surgeon used the drill guide to position an 8 ga, 230 mm long decompression device in the three synthetic femurs. CT scans were taken of the sawbones with the drill guide and decompression device. CT scans were processed in the 3D modeling software. Descriptive statistics measuring the angular and needle-tip deviation were compared to the original virtually planned model. RESULTS: Compared to the original 3D model, the trials had a mean displacement of 1.440 ± 1.03 mm and a mean angle deviation of 1.093 ± 0.749º. CONCLUSIONS: The drill guides were demonstrated to accurately guide the decompression device along its predetermined drill trajectory. Accuracy was assessed by comparing values to literature-reported values and considered AVN lesion size. This study demonstrates the potential use of 3D printing technology to improve the efficacy of CD techniques.

6.
3D Print Med ; 10(1): 7, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38427157

RESUMEN

BACKGROUND: The extended trochanteric osteotomy (ETO) is a surgical technique utilized to expose the intramedullary canal of the proximal femur, protect the soft tissues and promote reliable healing. However, imprecise execution of the osteotomy can lead to fracture, soft tissue injury, non-union, and unnecessary morbidity. We developed a technique to create patient specific, 3D-printed cutting guides to aid in accurate positioning of the ETO and improve osteotomy quality and outcomes. METHODS: Patient specific cutting guides were created based on CT scans using Synopysis Simpleware ScanIP and Solidworks. Custom 3D printed cutting guides were tested on synthetic femurs with foam cortical shells and on cadaveric femurs. To confirm accuracy of the osteotomies, dimensions of the performed osteotomies were compared to the virtually planned osteotomies. RESULTS: Use of the patient specific ETO cutting guides resulted in successful osteotomies, exposing the femoral canal and the femoral stem both in synthetic sawbone and cadaveric testing. In cadaveric testing, the guides allowed for osteotomies without fracture and cuts made using the guide were accurate within 6 percent error from the virtually planned osteotomy. CONCLUSION: The 3D-printed patient specific cutting guides used to aid in ETOs proved to be accurate. Through the iterative development of cutting guides, we found that a simple design was key to a reliable and accurate guide. While future clinical trials in human subjects are needed, we believe our custom 3D printed cutting guide design to be effective at aiding in performing ETOs for revision total hip arthroplasty surgeries.

7.
Arthroplast Today ; 26: 101340, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38455865

RESUMEN

Background: In revision total knee arthroplasty, tibial cones have demonstrated improved longevity and reduced incidence of aseptic loosening. Several currently available "off-the-shelf" (OTS) cone systems may not have sizes to accommodate all patient bone morphologies. Methods: Computed tomographies from one hundred primary total knee arthroplasty patients and dimensions of 4 OTS cones were obtained. Press-fit stems were positioned in 3D tibia models to fit the diaphyseal trajectory. Cones were positioned around the stem at 1, 6, and 13 mm resections measured from the trough of the medial tibial plateau, simulating proximal tibial cuts and bone loss. Tibias were examined for cortical breaching following modeled cone preparation. Results: Increased rate of breaching was observed as size and depth of the cone increased. In 2/49 (4.1%) male and 19/46 (41.3%) female tibias, cones could not be positioned without breaching. No breaches were found in 22/49 (45.0%) male and 5/46 (10.9%) female tibias. For every 1 centimeter increase in patient height, odds of breaching decreased by 12% (odds ratio: 0.88, confidence interval: 0.84, 0.92). For every size increase in cone width, odds of breaching increased by 34% (odds ratio: 1.34, confidence interval: 1.28, 1.47). Placing cones deeper also increased breaching compared to the 1 mm cut. Conclusions: In revision total knee arthroplasty, smaller OTS or custom tibial cones may be needed to fit a patient's proximal tibial geometry. This is especially true in patients not accommodated by the OTS cone sizes we tested, which impacted shorter patients and/or those with substantial bone loss requiring more tibial resection and deeper cone placement. Use of smaller or custom tibial cones should be considered where indicated.

8.
J Arthroplasty ; 39(2): 514-519.e3, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37625464

RESUMEN

BACKGROUND: In total hip arthroplasty (THA), femoral offset restoration results in optimal biomechanics and range of motion (ROM) without bone-bone impingement. We hypothesized that differences in implant design features significantly affect bone-bone impingement risk in primary THA. METHODS: This retrospective computer simulation study included a cohort of 43 primary robotic arm-assisted THA. Considering sagittal pelvic tilt, we measured the maximum external rotation at 0° hip flexion and the maximum internal rotation at both 90° and 100° hip flexion before any bone-bone impingement occurred. To influence the offset, we included neutral or extended polyethylene liners, neutral or plus prosthetic heads, standard or high-offset stems, and stems with 132° or 127° neck angles. RESULTS: Extended polyethylene liner use resulted in decreased bone-bone impingement for both stems but also decreased prosthetic ROM in hip extension (mean -4.5 to 5°, range -10 to 0°) and hip flexion (mean -3 to 3.7°, range -10 to 0°) due to decreases in head diameter. Using a plus head or different stem offset/neck angle options resulted in either (1) no improvement in ROM (stem 1: 60%; stem 2: 28%) or (2) a paradoxical increase in bone-bone impingement (stem 1 with 127°: 19% and stem 2 with high offset option: 7%). CONCLUSION: Counterintuitively, a subset of patients experience a paradoxical increase in bone-bone impingement when transitioning from standard to high-offset or varus necks due to the pelvic and proximal femoral bone shape. For this group of patients, preoperative personalized 3-dimensional modeling may help guide implant choice for optimizing outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Simulación por Computador , Estudios Retrospectivos , Rango del Movimiento Articular , Polietileno
9.
Res Sq ; 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38106183

RESUMEN

Background: Femoral head avascular necrosis (AVN), or death of femoral head tissue due to a lack of blood supply, is a leading cause of total hip replacement for non-geriatric patients. Core decompression (CD) is an effective treatment to re-establish blood flow for patients with AVN. Techniques aimed at improving its efficacy are an area of active research. We propose the use of 3D printed drill guides to accurately guide therapeutic devices for CD. Methods: Using femur sawbones, image processing software, and 3D modeling software, we created a custom-built device with pre-determined drill trajectories and tested the feasibility of the 3D printed drill guides for CD. A fellowship trained orthopedic surgeon used the drill guide to position an 8 ga, 230 mm long decompression device in the three synthetic femurs. CT scans were taken of the sawbones with the drill guide and decompression device. CT scans were processed in the 3D modeling software. Descriptive statistics measuring the angular and needle-tip deviation were compared to the original virtually planned model. Results: Compared to the original 3D model, the trials had a mean displacement of 1.440±1.03 mm and a mean angle deviation of 1.093±0.749°. Conclusions: The drill guides were demonstrated to accurately guide the decompression device along its predetermined drill trajectory. Accuracy was assessed by comparing values to literature-reported values and considered AVN lesion size. This study demonstrates the potential use of 3D printing technology to improve the efficacy of CD techniques.

10.
Arthrosc Tech ; 12(10): e1853-e1858, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37942111

RESUMEN

Three-dimensional (3D) modeling and printing are increasingly used in the field of orthopaedic surgery for both research and patient care. One area where they are particularly helpful is in improving our understanding of the patellofemoral (PF) joint. Heretofore, morphological studies that use 3D models of the PF joint have primarily been based on computed tomography imaging data and thus do not incorporate articular cartilage. Here, we describe a method for creating 3D models of the articular surfaces of the PF joint based on magnetic resonance imaging. Models created using this technique can be used to improve our understanding of the morphology of the articular surfaces of the PF joint and its relationship to joint pathologies. Of particular interest is our finding of articular congruity in printed articular cartilage surfaces of dysplastic PF joints of recurrent patella dislocators.

11.
Clin Biomech (Bristol, Avon) ; 110: 106129, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37871506

RESUMEN

BACKGROUND: The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing. METHODS: First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains. FINDINGS: In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%. INTERPRETATION: The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Humanos , Reproducibilidad de los Resultados , Tornillos Óseos , Fenómenos Biomecánicos , Placas Óseas , Fracturas del Fémur/cirugía , Análisis de Elementos Finitos , Cadáver
12.
JBMR Plus ; 7(10): e10796, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37808393

RESUMEN

Degenerative osteoarthritis (OA) is recognized as an early-onset comorbidity of X-linked hypophosphatemia (XLH), contributing to pain and stiffness and limiting range of motion and activities of daily living. Here, we extend prior findings describing biochemical and cellular changes of articular cartilage (AC) in the phosphate-wasting environment of XLH to determine the impact of these changes on the biomechanical properties of AC in compression and potential role in the etiology of OA. We hypothesize that despite increased proteoglycan biosynthesis, disruption of the mineralized zone of AC impacts the mechanical properties of cartilage that function to accommodate loads and that therapeutic restoration of this zone will improve the mechanical properties of AC. Data were compared between three groups: wild type (WT), Hyp, and Hyp mice treated with calcitriol and oral phosphate. EPIC microCT confirmed AC mineral deficits and responsiveness to therapy. MicroCT of the Hyp subchondral bone plate revealed that treatment improved trabecular bone volume (BV/TV) but remained significantly lower than WT mice in other trabecular microstructures (p < 0.05). Microindentation AC studies revealed that, compared with WT mice, the mean stiffness of tibial AC was significantly lower in untreated Hyp mice (2.65 ± 0.95 versus 0.87 ± 0.33 N/mm, p < 0.001) and improved with therapy (2.15 + 0.38 N/mm) to within WT values. Stress relaxation of AC under compressive loading displayed similar biphasic relaxation time constants (Taufast and Tauslow) between controls and Hyp mice, although Tauslow trended toward slowed relaxation times. In addition, Taufast and Tauslow times correlated with peak load in WT mice (r = 0.80; r = 0.78, respectively), whereas correlation coefficient values for Hyp mice (r = 0.46; r = 0.21) improved with treatment (r = 0.71; r = 0.56). These data provide rationale for therapies that both preserve AC stiffness and recovery from compression. The Hyp mouse also provides unique insight into determinants of structural stiffness and the viscoelastic properties of AC in the progression of OA. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

13.
J Bone Miner Res ; 38(9): 1350-1363, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37436066

RESUMEN

Genome-wide association studies (GWASs) have advanced our understanding of the genetics of osteoporosis; however, the challenge has been converting associations to causal genes. Studies have utilized transcriptomics data to link disease-associated variants to genes, but few population transcriptomics data sets have been generated on bone at the single-cell level. To address this challenge, we profiled the transcriptomes of bone marrow-derived stromal cells (BMSCs) cultured under osteogenic conditions from five diversity outbred (DO) mice using single-cell RNA-seq (scRNA-seq). The goal of the study was to determine if BMSCs could serve as a model to generate cell type-specific transcriptomic profiles of mesenchymal lineage cells from large populations of mice to inform genetic studies. By enriching for mesenchymal lineage cells in vitro, coupled with pooling of multiple samples and downstream genotype deconvolution, we demonstrate the scalability of this model for population-level studies. We demonstrate that dissociation of BMSCs from a heavily mineralized matrix had little effect on viability or their transcriptomic signatures. Furthermore, we show that BMSCs cultured under osteogenic conditions are diverse and consist of cells with characteristics of mesenchymal progenitors, marrow adipogenic lineage precursors (MALPs), osteoblasts, osteocyte-like cells, and immune cells. Importantly, all cells were similar from a transcriptomic perspective to cells isolated in vivo. We employed scRNA-seq analytical tools to confirm the biological identity of profiled cell types. SCENIC was used to reconstruct gene regulatory networks (GRNs), and we observed that cell types show GRNs expected of osteogenic and pre-adipogenic lineage cells. Further, CELLECT analysis showed that osteoblasts, osteocyte-like cells, and MALPs captured a significant component of bone mineral density (BMD) heritability. Together, these data suggest that BMSCs cultured under osteogenic conditions coupled with scRNA-seq can be used as a scalable and biologically informative model to generate cell type-specific transcriptomic profiles of mesenchymal lineage cells in large populations. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


Asunto(s)
Ratones de Colaboración Cruzada , Células Madre Mesenquimatosas , Ratones , Animales , Ratones de Colaboración Cruzada/genética , Diferenciación Celular/genética , Transcriptoma/genética , Estudio de Asociación del Genoma Completo , Análisis de Expresión Génica de una Sola Célula , Células Cultivadas , Células Madre Mesenquimatosas/metabolismo , Osteogénesis/genética , Células del Estroma/metabolismo , Células de la Médula Ósea
14.
Blood Adv ; 7(17): 5156-5171, 2023 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-37417950

RESUMEN

Iron deficiency is a potent stimulator of fibroblast growth factor 23 (FGF23), a hormonal regulator of phosphate and vitamin D metabolism, that is classically thought to be produced by bone-embedded osteocytes. Here, we show that iron-deficient transmembrane serine protease 6 knockout (Tmprss6-/-) mice exhibit elevated circulating FGF23 and Fgf23 messenger RNA (mRNA) upregulation in the bone marrow (BM) but not the cortical bone. To clarify sites of Fgf23 promoter activity in Tmprss6-/- mice, we introduced a heterozygous enhanced green fluorescent protein (eGFP) reporter allele at the endogenous Fgf23 locus. Heterozygous Fgf23 disruption did not alter the severity of systemic iron deficiency or anemia in the Tmprss6-/- mice. Tmprss6-/-Fgf23+/eGFP mice showed green fluorescence in the vascular regions of BM sections and showed a subset of BM endothelial cells that were GFPbright by flow cytometry. Mining of transcriptomic data sets from mice with normal iron balance revealed higher Fgf23 mRNA in BM sinusoidal endothelial cells (BM-SECs) than that in other BM endothelial cell populations. Anti-GFP immunohistochemistry of fixed BM sections from Tmprss6-/-Fgf23+/eGFP mice revealed GFP expression in BM-SECs, which was more intense than in nonanemic controls. In addition, in mice with intact Tmprss6 alleles, Fgf23-eGFP reporter expression increased in BM-SECs following large-volume phlebotomy and also following erythropoietin treatment both ex vivo and in vivo. Collectively, our results identified BM-SECs as a novel site for Fgf23 upregulation in both acute and chronic anemia. Given the elevated serum erythropoietin in both anemic models, our findings raise the possibility that erythropoietin may act directly on BM-SECs to promote FGF23 production during anemia.


Asunto(s)
Anemia Ferropénica , Eritropoyetina , Animales , Ratones , Anemia Ferropénica/genética , Anemia Ferropénica/metabolismo , Médula Ósea/metabolismo , Modelos Animales de Enfermedad , Células Endoteliales/metabolismo , Eritropoyetina/genética , Eritropoyetina/metabolismo , Hierro , ARN Mensajero/genética , Regulación hacia Arriba
15.
Arthrosc Tech ; 12(3): e401-e406, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37013007

RESUMEN

Three-dimensional (3D) modeling and printing comprise an important tool for orthopaedic surgeons. One area in which 3D modeling has the potential to dramatically improve our understanding of biomechanical kinematics is pathologies of the patellofemoral joint, in particular trochlear dysplasia. We describe a method for creating 3D printed models of the patellofemoral joint, including computed tomography image acquisition, image segmentation, model creation, and 3D printing. The models created can help surgeons understand and plan surgery for recurrent patellar dislocations.

16.
J Arthroplasty ; 38(7): 1385-1391, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36709882

RESUMEN

BACKGROUND: Studies suggest that posterior hip precautions are unnecessary after total hip arthroplasty; however, many surgeons and patients choose to follow these precautions to some extent. In this study, we hypothesized that 20° of hip abduction would be sufficient to prevent impingement and dislocation in motions requiring hip flexion when using larger prosthetic heads (≥36 mm) when the acetabular implant is placed within a reasonable orientation (anteversion:15-25° and inclination: 40-60°). METHODS: Using a robotic hip platform, we investigated the effect of hip abduction on prosthetic and bony impingement in 43 patients. For the flexed seated position, anterior pelvic tilt angles of 10 and 20° were chosen, while anterior pelvic tilt angles of 70 and 90° were chosen for the bending forward position. An additional 10° of hip external rotation and 10 or 20° of hip internal rotation were also added to the simulation. One hip received a 32-mm head; otherwise, 36-, 40-mm, or dual-mobility heads were used. The study power was 0.99, and the effect size was 0.644. RESULTS: In 65% of the cases, bone-bone impingement between the calcar and anterior-inferior iliac spine was the main type of impingement. The absolute risk of impingement decreased between 0 and 16.3% in both tested positions with the addition of 20° hip abduction. CONCLUSION: With modern primary total hip arthroplasty stems (low neck diameter) and an overall acceptable cup anteversion angle, small degrees of hip abduction may be the only posterior hip precaution strategy required to lower the risk of dislocation among patients. Future studies can potentially investigate the concept of personalized hip precautions based on preoperative computer simulations, utilized implants, hip-spine relations, and final implant orientation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Enfermedades Óseas , Prótesis de Cadera , Luxaciones Articulares , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/cirugía , Simulación por Computador , Fémur/cirugía , Acetábulo/cirugía , Luxaciones Articulares/cirugía , Rango del Movimiento Articular , Enfermedades Óseas/cirugía , Articulación de la Cadera/cirugía
17.
Knee ; 40: 283-291, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36529046

RESUMEN

BACKGROUND: It is unclear howmetal augments,polyethylene (PE) liner thickness, and length of cemented stemcontribute to load transferwhen reconstructing uncontained tibial metaphyseal bone loss of Anderson Orthopedic Research Institute (AORI) Type II defects during revision total knee arthroplasty (rTKA).The aimof this study is to understand the impact of these three variableson load transfer through the tibial baseplate. For a fixed defect depth, we hypothesized that there is a particular combination of liner and augment thickness and stem length that minimizes bone stress, reducing the risk of aseptic loosening. METHODS: We conducted a finite element analysis (FEA) to model stresses at the bone-cement interface with different iterations of metal augments, PE liner thicknesses andfully-cemented stems lengths. RESULTS: For a 20 mm tibial defect, constructs with thicker metal augments and thinner polyethylene liners were superior. Constructswith a fully cemented stem further reduced bone stress on the tibial plateau. Bone stress was lowest when a 100 mm fully-cemented stem was used, while stems between 30 mm - 80 mm produced similar results. CONCLUSIONS: When addressing a tibial bone defect of AORI Type II in rTKA, our FEA model demonstrates that surgeons should opt to use the thickest metal augments in combination with afully-cemented stem with an added length of at least 30 mm, which allows for surgical flexibility together with the most stable construct.Our study is notably limited by lack of modeling of knee joint moments, which are important when considering micromotion, bone-implant interface and stem effectiveness.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Polietileno , Reoperación , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/cirugía , Metales , Diseño de Prótesis
18.
Geriatr Orthop Surg Rehabil ; 13: 21514593221141376, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36533207

RESUMEN

Introduction: Geriatric patients who suffer femoral neck fractures have high morbidity and mortality. Prophylactic fixation of the femoral neck is a potential avenue to reduce the incidence of femoral neck fractures. We studied 3 different implants traditionally used to stabilize the femoral neck: 6.5 mm cannulated screws (CANN), the femoral neck system (FNS) (Depuy Synthes), and the dynamic hip screw (DHS) (Depuy Synthes). Materials and Methods: Five osteoporotic Sawbone femurs were used for each model and a control group. Two scenarios were investigated: single leg stance to measure construct stiffness and lateral impact to measure construct stiffness, energy to fracture, and qualitative examination of fracture patterns. Stiffness for each femur and energy to fracture for the lateral impact scenario were calculated and compared between groups using one-way ANOVA. Results: DHS showed significantly higher stiffness than the other 2 implants and the control in single leg stance. In the lateral impact scenario, the DHS and CANN were significantly stiffer FNS and the control. Femurs implanted with CANN tended to fracture at the greater trochanter while FNS fractured in a transverse subtrochanteric pattern, and DHS fractured obliquely in the subtrochanteric region. Discussion: FNS and DHS experienced fracture patterns less amenable to surgical correction. CANN and DHS proved better able to resist external forces in the lateral fall scenario. CANN also proved better able to resist external forces in the single leg stance scenario and experienced a more amenable fracture pattern in the lateral fall scenario. Conclusions: FNS was less able to resist external forces compared with the other implants. This work informs the potential implications between the choice of implants that, although historically have not been used prophylactically, may be considered in the future for prophylactic stabilization of the femoral neck. Cadaveric study and clinical trials are recommended for further study.

19.
Geriatr Orthop Surg Rehabil ; 13: 21514593221135117, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36393901

RESUMEN

Introduction: Hip fractures cause significant morbidity and mortality for geriatric patients, and incidence is increasing as the population ages. Following a primary hip fracture, up to 20% may suffer a contralateral hip fracture within 5 years despite fracture risk reduction measures, including fall prevention and osteoporosis pharmacologic treatment. The aim of this study is to assess whether insertion of the Femoral Neck System (Depuy Synthes, West Chester, PA) into the contralateral proximal femur may strengthen the bone and decrease the incidence of contralateral hip fractures. Materials and Methods: ScanIP, an image processing software was used to produce 3-dimensional models of a cadaver femur with the implanted device. Models were meshed and exported to Abaqus for finite element analysis to evaluate the device's ability to reduce stress in the proximal femur. Results were analyzed for element-wise volume and von-Mises stresses. Results: The implant reduced peak stress and bone failure at all levels of bone quality. Specifically in osteoporotic bone, the implant decreased peak stress by 27%, proximal femur trabecular bone failure by 5% and cortical bone failure by 100% in the femoral neck. Conclusions: Our results from computer generated finite element analyses indicate that the Femoral Neck System may strengthen an osteoporotic proximal femur in the event of a lateral fall. Further investigation with expanded finite element analysis and cadaveric biomechanical studies are needed to validate these results.

20.
BMC Biomed Eng ; 4(1): 8, 2022 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-36153577

RESUMEN

BACKGROUND: Finite element modelling the material behavior of bone in-silico is a powerful tool to predict the best suited surgical treatment for individual patients. RESULTS: We demonstrate the development and use of a pre-processing plug-in program with a 3D modelling image processing software suite (Synopsys Simpleware, ScanIP) to assist with identifying, isolating, and defining cortical and trabecular bone material properties from patient specific computed tomography scans. The workflow starts by calibrating grayscale values of each constituent element with a phantom - a standardized object with defined densities. Using an established power law equation, we convert the apparent density value per voxel to a Young's Modulus. The resulting "calibrated" scan can be used for modeling and in-silico experimentation with Finite Element Analysis. CONCLUSIONS: This process allows for the creation of realistic and personalized simulations to inform a surgeon's decision-making. We have made this plug-in program open and accessible as a supplemental file.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...