Eur J Oral Sci ; 131(5-6): e12949, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37593975

RESUMEN

Radiographic findings from long-term studies of periodontitis treatment have rarely been reported. Although bone destruction is a prominent feature of periodontitis, the long-term effect on alveolar bone levels of different treatment strategies, with or without adjunctive metronidazole (MTZ), has not been reported. We investigated the 5-year radiographic outcome of therapy in patient groups treated with conventional scaling and root planing (SRP) or same-day full-mouth disinfection (FDIS), with or without adjunctive MTZ. Following a 3-month oral hygiene phase, 184 periodontitis patients were randomly allocated to one of four treatment regimens: (i) FDIS+MTZ; (ii) FDIS+placebo; (iii) SRP+MTZ; or (iv) SRP+placebo. Following active treatment, patients received biannual maintenance. In total, 161 patients (87.5%) completed the 5-year follow-up examination, at which the radiographic bone level (RBL), clinical attachment level, probing pocket depth, presence of plaque, and bleeding were recorded again. At the 5-year follow up examination, minor radiological bone loss was observed in the intervention groups FDIS+placebo, SRP+MTZ, and SRP+placebo; by contrast, the FDIS+MTZ group did not show any change in RBL. Full-mouth disinfection did not generally perform better than conventional SRP performed over a period of 2 to 4 weeks.


Asunto(s)
Periodontitis Crónica , Periodontitis , Humanos , Periodontitis/diagnóstico por imagen , Periodontitis/terapia , Metronidazol/uso terapéutico , Raspado Dental , Aplanamiento de la Raíz , Higiene Bucal , Resultado del Tratamiento
2.
BMC Oral Health ; 15: 107, 2015 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-26350934

RESUMEN

BACKGROUND: The reproducibility of measurements on radiographs is influenced by the techniques by which the images as well as the measurements are obtained. Thus, bias resulting from errors in the image and/or image examinations at two points in time may result in wrongful registrations of true biological or pathological changes. The aim of the present study was to propose and evaluate an indirect radiological examination technique, by which bias, when measuring radiographic bone level, could be substantially reduced as compared to the technique using direct mm measurements. METHODS: A plugin to ImageJ was designed to reduce bias when measuring bone loss on radiographic images. In human dry mandibles, radiographic images of 20 teeth were obtained parallel with the tooth axis (alpha = 0) and at an angle of 30° deviation. The direct technique of measuring radiographic bone level (RBL) and the indirect, length-adjusted RBL were registered by four researchers in a double blinded fashion. RESULTS: When mean RBL measured at 0° angle was 7.0 mm, the corresponding mean RBL measured at 30° angle was 7.8 mm, signifying an 11.4% increase (p = 0.032), whereas the mean length-adjusted RBL increased by 0.6% (p = 0.9). CONCLUSIONS: This study showed that the use of the original, direct technique (ImageJ) resulted in markedly biased radiographic bone level at 30° angle, while the proposed indirect length-adjusted technique (ImageJ plugin) did not.


Asunto(s)
Pérdida de Hueso Alveolar/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Radiografía Dental Digital/métodos , Proceso Alveolar/diagnóstico por imagen , Sesgo , Método Doble Ciego , Humanos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Estudios Longitudinales , Mandíbula/diagnóstico por imagen , Radiografía Dental Digital/estadística & datos numéricos , Ápice del Diente/diagnóstico por imagen , Cuello del Diente/diagnóstico por imagen , Corona del Diente/diagnóstico por imagen