1.
Anal Biochem ; 694: 115634, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39094782

RESUMEN

Lateral-flow immunoassays (LFAs) can be used to diagnose urinary tract infections caused by Escherichia coli (E. coli) at the point of care. Unfortunately, urine samples containing dilute concentrations of E. coli can yield false negative results on LFAs. Our laboratory was first to implement aqueous two-phase systems (ATPSs) to preconcentrate samples into smaller volumes prior to their application on LFAs. This is achieved by manipulating the ratio of the volume of the top phase to that of the bottom phase (volume ratio; VR) and concentrating biomarkers in the bottom phase which, when applied to LFAs in fixed volumes, leads to corresponding improvements in sensitivity. This work is the first demonstration that the same LOD can be achieved irrespective of the VR when the entire bottom phase is added to LFAs. A custom 3D-printed device was also developed to decrease liquid handling steps. Across different VRs expected from patient urine variability, this diagnostic workflow successfully detected E. coli concentrations down to 2 × 105 colony-forming units (cfu) mL-1 in synthetic urine, demonstrating consistent 10-fold improvements in sensitivity compared to trials conducted without ATPS preconcentration. This method successfully addresses the variability of patient samples while remaining easy to use at the point of care.

2.
Soft Matter ; 18(42): 8147-8156, 2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36254668

RESUMEN

In this work, we present a novel point-of-care hydrogel-based diagnostic device for the rapid detection of elevated bicarbonate levels in serum for the diagnosis of mild to severe cases of metabolic alkalosis. Our system consists of hydrogel beads composed of calcium alginate and the nonionic polymer dextran. This assay utilizes the reaction of sodium bicarbonate and citric acid to produce citrate, a metal chelator capable of competitively binding to calcium cations in the gel matrix to trigger hydrogel degradation. This results in successful detection of elevated bicarbonate concentrations in less than one hour. Specifically, critically high bicarbonate concentrations of 50, 45, and 40 mmol L-1 in human serum were detected in as little as 10, 15, and 20 min, respectively. To demonstrate the assay's feasibility for use in resource-limited settings, we developed a simple electronic device that achieved similar results and could be used by untrained individuals with no lab equipment and minimal power. To our knowledge, this is the first demonstration of the use of nonionic polymers to synthesize and improve the morphology of calcium alginate hydrogel beads using a simple processing method that involves minimal labor and equipment. The simplified bead synthesis protocol combined with the user-friendly device allows for the rapid detection of metabolic alkalosis at the point of care.


Asunto(s)
Alcalosis , Bicarbonatos , Humanos , Sistemas de Atención de Punto , Hidrogeles , Ácido Cítrico , Alginatos