1.
Front Cardiovasc Med ; 11: 1361761, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38572304

RESUMEN

Background and aims: Right phrenic nerve palsy is the most frequent complication of cryoballoon procedures. The SMARTFREEZE™ console (Boston Scientific, St. Paul, MN, USA) has integrated a new tool for diaphragm monitoring-the Diaphragm Movement Sensor; however, it has not been evaluated in clinical practice. We aimed to assess the diagnostic performance of the Diaphragm Movement Sensor based on compound motor action potential data recorded simultaneously. Methods: Thirty consecutive patients (mean age 63.2 ± 10.2 years) were included. We simultaneously recorded the compound motor action potential and the Diaphragm Movement Sensor during cryoapplications in the right pulmonary veins. The right phrenic nerve was paced at 60 per minute, 12 V and 2.9 ms. Compound motor action potential monitoring with a 30% decrease cutoff for the diagnosis of phrenic nerve threatening was considered the gold standard. The Diaphragm Movement Sensor decrease threshold was also set at 30%. Results: Considering compound motor action potential monitoring, phrenic nerve threatening occurred 11 times (in seven patients) among 84 cryoapplications (13.1%) at the right pulmonary veins. The sensitivity and specificity of the Diaphragm Movement Sensor were, respectively, 33% (95% CI: 7%-70%) and 49% (95% CI: 38%-61%; P < 0.001). The predictive positive and negative values for the Diaphragm Movement Sensor were, respectively, 7% (95% CI: 2%-20%) and 86% (95% CI: 72%-95%). The Diaphragm Movement Sensor gave an erroneous diagnosis in 44/84 cryoapplications (52.4%). Conclusions: The diagnostic performance of the Diaphragm Movement Sensor is low, and the relevance of its use in clinical practice may be debated.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38478165

RESUMEN

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

4.
Heart ; 109(5): 364-371, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-36396438

RESUMEN

OBJECTIVE: We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL). METHODS: Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation. Primary efficacy outcome was time to first recurrence of sustained (>30 s) symptomatic atrial arrhythmia (AF/AFL/atrial tachycardia) at 12 months as assessed by continuous monitoring with an implantable loop recorder. Primary safety outcome was a composite of death, stroke, tamponade requiring drainage, atrio-oesophageal fistula, pacemaker implantation, serious vascular complications or persistent phrenic nerve palsy. RESULTS: Trial recruitment was halted at 113 of the target 130 patients because of the SARS-CoV-2 pandemic (PVI, n=59; CTI ablation, n=54). Median age was 66 (IQR 61-71) years, with 98 (86.7%) men. At 12 months, the primary outcome occurred in 11 (18.6%) patients in the PVI group and 9 (16.7%) patients in the CTI group. There was no significant difference in the primary efficacy outcome between the groups (HR 1.11, 95% CI 0.46 to 2.67). AFL recurred in six (10.2%) patients in the PVI arm and one (1.9%) patient in the CTI arm (p=0.116). Time to occurrence of AF of ≥2 min was significantly reduced with cryoballoon PVI (HR 0.46, 95% CI 0.25 to 0.85). The composite safety outcome occurred in four patients in the PVI arm and three patients in the CTI arm (p=1.000). CONCLUSION: Cryoballoon PVI as first-line treatment for AFL is equally effective compared with standard CTI ablation for preventing recurrence of atrial arrhythmia and better at preventing new-onset AF. TRIAL REGISTRATION NUMBER: NCT03401099.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , COVID-19 , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Anciano , Femenino , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/epidemiología , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , COVID-19/complicaciones , SARS-CoV-2 , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Recurrencia
5.
J Interv Card Electrophysiol ; 66(2): 445-453, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35997848

RESUMEN

BACKGROUND: Very high power short duration (vHPSD) radiofrequency ablation (RFA) may reduce ablation times and improve patient tolerability, permitting pulmonary vein isolation (PVI) under mild conscious sedation (mCS) and promoting same day discharge (SDD). METHODS: First, a retrospective feasibility study was performed at 2 tertiary cardiac centres in the UK. Consecutive cases of first-time PVI using vHPSD ablation with 90 W lesions for up to 4 s were compared against cases performed using standard RF (sRF) and cryoballoon (Cryo) therapy. Subsequently, a prospective study of patients who had vHPSD or Cryo exclusively under mCS was undertaken. Questionnaires based on Likert and visual analogue scales (VAS) were used to measure anxiety, discomfort and pain. RESULTS: In total, 182 patients (59 vHPSD, 62 sRF and 61 Cryo) were included in the retrospective study, with 53 (90%) of vHPSD cases successfully performed under mCS. PVI ablation time in the vHPSD group (5.8 ± 1.7 min) was shorter than for sRF (16.5 ± 6.3 min, p < 0.001) and Cryo (17.5 ± 5.9 min, p < 0.001). Fifty-one vHPSD and 52 Cryo patients were included in the prospective study. PVI ablation time in the vHPSD group was shorter than for the Cryo group (6.4 ± 2.9 min vs 17.9 ± 5.7 min, p < 0.001), but overall procedure duration was longer (121 ± 39 min vs 95 ± 20 min, p < 0.001). There were no differences in the patient experience of anxiety, discomfort or pain. SDD rates were the same in both groups (61% vs 67%, p = 0.49). CONCLUSIONS: vHPSD RFA for PVI can be performed under mCS to achieve SDD rates comparable to cryoablation, without compromising patient experience.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Sedación Consciente , Resultado del Tratamiento , Evaluación del Resultado de la Atención al Paciente , Venas Pulmonares/cirugía
6.
Indian Pacing Electrophysiol J ; 22(4): 200-206, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35642824

RESUMEN

BACKGROUND: Ablation index (AI)-guided ablation for posterior wall isolation (PWI) using high-power, short-duration remains untested. We sought to evaluate the acute outcomes of AI-guided 50 W ablation vs. conventional ablation, and investigate the differences in relationship between contact force (CF), time and AI in both groups. METHODS: Consecutive patients undergoing first-time AI-guided ablation with PWI using either 50 W or 35-40 W ablation were enrolled. Acute procedural metrics and individual lesion level ablation data were compared between groups. RESULTS: 40 patients (50 W: n = 20, 35-40 W: n = 20) with atrial fibrillation were included. Total procedure time was significantly reduced with 50 W (120 vs. 143 mins, p = 0.004) and there was a trend toward decreased ablation time (22 vs. 28 mins, p = 0.052). First pass and acute success of PWI were comparable between the 50 W and 35-40 W groups (10 vs. 8 patients, p = 0.525 and 20 vs. 19 patients, p = 1.000, respectively). Individual lesion analysis of all 959 RF applications (50 W: n = 458, 35-40 W: n = 501) demonstrated that 50 W ablation led to lower ablation time per lesion (10.4 vs. 13.0s, p < 0.001), and increased AI (471 vs. 461, p < 0.001) and impedance drop (7.4 vs. 6.9ohms, p = 0.007). Excessive ablations (AI>600 for roof line; AI>500 elsewhere) were more frequently observed in the 50 W group (9.0% vs. 4.6%, p = 0.007). CF had very good discriminative capability for excessive ablation in both groups. At 50 W, limiting the CF to <10 g reduced the number of excessive ablations on the floor line and within the posterior box to 12% and 4%,respectively. Recurrence of atrial arrhythmias at 12 months were comparable between the groups. CONCLUSION: AI-guided 50 W RF ablation reduces the ablation time of individual lesions and total procedure time without compromising first pass and acute success rates of PWI or 12-month outcomes compared to conventional powers.

7.
Front Cardiovasc Med ; 9: 814026, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35211527

RESUMEN

BACKGROUND: Compound motor action potential (CMAP) monitoring is a common method used to prevent right phrenic nerve palsy during cryoballoon ablation for atrial fibrillation. OBJECTIVE: We compared recordings simultaneously obtained with surface and hepatic electrodes. METHODS: We included 114 consecutive patients (mean age 61.7 ± 10.9 years) admitted to our department for cryoballoon ablation. CMAP was monitored simultaneously with a hepatic catheter and a modified lead I ECG, whilst right phrenic nerve was paced before (stage 1) and during (stage 2) the right-sided freezes. If phrenic threat was detected with hepatic recordings (CMAP amplitude drop >30%) the application was discontinued with forced deflation. RESULTS: The ratio of CMAP/QRS was 4.63 (2.67-9.46) for hepatic and 0.76 (0.55-1.14) for surface (p < 0.0001). Signal coefficients of variation during stage 1 were 3.92% (2.48-6.74) and 4.10% (2.85-5.96) (p = 0.2177), respectively. Uninterpretable signals were more frequent on surface (median 10 vs. 0; p < 0.0001). For the 14 phrenic threats, the CMAP amplitude dropped by 35.61 ± 8.27% on hepatic signal and by 33.42 ± 11.58% concomitantly on surface (p = 0.5417). Our main limitation was to achieve to obtain stable phrenic capture (57%). CMAP monitoring was not reliable because of pacing instability in 15 patients (13.16%). A palsy occurred in 4 patients (3.51%) because cryoapplication was halted too late. CONCLUSION: Both methods are feasible with the same signal stability and amplitude drop precocity during phrenic threats. Clarity and legibility are significantly better with hepatic recording (sharper signals, less far-field QRS). The two main limitations were pacing instability and delay between 30% CMAP decrease and cryoapplication discontinuation.

8.
Europace ; 23(6): 878-886, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33693677

RESUMEN

AIMS: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. METHODS AND RESULTS: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35-40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35-40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions (n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35-40 W groups, respectively (P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W group (9.7% vs. 4.3%, P < 0.001). CONCLUSION: Ablation Index-guided 50 W AF ablation is as safe and effective as lower powers and results in reduced ablation and procedure times. Radiofrequency lesions are more likely to be therapeutic, but there is a higher risk of delivering excessive ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Benchmarking , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
9.
J Interv Card Electrophysiol ; 60(3): 427-432, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32385774

RESUMEN

PURPOSE: Treatment of typical atrial flutter (AFL) with cavo-tricuspid isthmus (CTI) ablation is associated with a high occurrence rate of new onset atrial fibrillation (AF) during follow-up. There are data to support the addition of pulmonary vein isolation (PVI) to CTI ablation in patients with both AF and AFL, but the role of cryoballoon PVI only, with no CTI ablation, in AFL patients with no prior documentation of AF has not been studied. METHODS: CRAFT is an international, prospective, randomised, open with blinded assessment, multicentre superiority study comparing radiofrequency CTI ablation and cryoballoon PVI in patients with typical AFL. Participants with typical AFL are randomised in a 1:1 ratio to either treatment arm, with patients randomised to PVI not receiving CTI ablation. Post-procedural cardiac monitoring is performed using an implantable loop recorder. The primary endpoint is time to first recurrence of sustained symptomatic atrial arrhythmia. Key secondary endpoints include (1) total arrhythmia burden at 12 months, (2) time to first episode of AF lasting ≥ 2 min, (3) time to recurrence of AFL or AT and (4) procedural and fluoroscopy times. The primary safety endpoint is the composite of death, stroke/transient ischaemic attack, cardiac tamponade requiring drainage, atrio-oesophageal fistula, requirement for a permanent pacemaker, serious vascular complications requiring intervention or delaying discharge and persistent phrenic nerve palsy lasting > 24 h. CONCLUSION: This study compares the outcomes of 2 different approaches to typical AFL-the conventional 'substrate'-based strategy of radiofrequency CTI ablation versus a novel 'trigger'-based strategy of cryoballoon PVI. TRIAL REGISTRATION: ( ClinicalTrials.gov ID: NCT03401099 ).


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
10.
Europace ; 20(5): 823-828, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28666317

RESUMEN

Aims: Leadless cardiac pacing has recently been proposed as alternative to conventional right ventricular (RV) pacing. With this approach, devices are directly screwed or fixed with tines in the RV wall, but the possible consequences on RV and tricuspid valve (TV) structure and function remain unknown. We thus conducted a study to evaluate this potential impact in chronically implanted patients. Methods and results: Repeated echocardiographic studies were performed prior to implantation, at discharge, and 2 months thereafter on all consecutive patients implanted with a leadless pacemaker at our centre between October 2014 and end-December 2015. Whenever possible, patients were evaluated in non-paced rhythm. Anatomical and functional parameters of RV, TV, and left cardiac structures were assessed. Overall, 23 patients (12 females, aged 85.2 ± 6.3 years) were included, with 14 implanted using Nanostim™ (Saint Jude Medical) and 9 with Micra™ (Medtronic). Indications for pacing were paroxysmal atrio-ventricular block in 12 patients, intermittent sinus bradycardia in 5, unexplained syncope in 3, and atrial fibrillation with slow ventricular rate in the remaining 3. The pacing percentage was 34 ± 42% at the last visit. Most devices were implanted in the septo-apical or mid-septal region. There were no significant changes in echocardiographic parameters observed. One patient developed significantly increased TV regurgitation, without abnormal leaflet motion or TV annulus size changes, suggesting it to be due to RV pressure changes. Conclusion: In patients chronically implanted with leadless pacemakers, there were no significant changes in heart structure and function observed, especially concerning the RV and TV.


Asunto(s)
Estimulación Cardíaca Artificial/efectos adversos , Ventrículos Cardíacos , Implantación de Prótesis , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Francia , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/etiología