Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
Diagnostics (Basel) ; 14(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38893599

RESUMEN

These images involved the case of a 51-year-old woman who had a history of chronic abdominal pain, iron deficiency, and diarrhoea but no blood or mucus in her stool. She had never undergone major abdominal surgery, and her past medical evaluation diagnosed her with celiac disease, leading to the adoption of a gluten-free diet alleviating most of her gastrointestinal symptoms. However, years later, her abdominal pain returned, so she underwent an abdominal ultrasound, revealing non-specific bowel loop dilation, and a weakly positive faecal occult blood test led to a colonoscopy. Despite many efforts to advance the scope beyond the transverse colon, colonoscopy was arduous and not complete, even after several changes in decubitus and abdominal compressions. Therefore, a virtual colonoscopy was conducted, revealing no intraluminal masses, but the entire colon was located on the left side of the abdomen. Indeed, the results showed sigma and that most of the colon was curled up in the small pelvis. This rare anatomical variant, known as "Mesenterium commune" (MC), is a type of gut malrotation that develops in childhood due to a lack of omphalomesenteric loop rotation during the embryonic period. This condition can lead to episodes of intestinal obstruction, potentially resulting in an acute abdomen and leading to surgical correction. Symptoms include chronic recurring abdominal pain, nausea, vomiting, and occasionally bloody stools. Few cases of this extremely rare condition have been reported in the literature so far.

5.
VideoGIE ; 8(12): 479-482, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38155825

RESUMEN

Video 1Multidisciplinary management of an intraprocedural endobronchial bleeding after EUS-guided transesophageal FNB of a pulmonary mass.

7.
VideoGIE ; 8(9): 367-369, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37719952

RESUMEN

Video 1Video showing a rare case of pedunculated ampulloma: imaging evaluation and resection technique.

8.
VideoGIE ; 8(8): 310-312, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37575144

RESUMEN

Video 1Case showing a complete intraperitoneal maldeployment of a lumen-apposing metal stent during EUS-guided gastro-entero-anastomosis for malignant gastric outlet obstruction, which was rescued through a retrieval with peritoneoscopy through natural orifice transluminal endoscopic surgery.

12.
Cancers (Basel) ; 15(9)2023 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-37174051

RESUMEN

BACKGROUND: The treatments for cancer palliation in patients with concomitant malignant biliary obstruction (MBO) and gastric outlet obstruction (MGOO) are still under investigation due to the lack of evidence available in the medical literature. We performed a systematic search and critical review to investigate efficacy and safety among patients with MBO and MGOO undergoing both endoscopic ultrasound-guided biliary drainage (EUS-BD) and MGOO endoscopic treatment. METHODS: A systematic literature search was performed in PubMed, MEDLINE, EMBASE, and the Cochrane Library. EUS-BD included both transduodenal and transgastric techniques. Treatment of MGOO included duodenal stenting or EUS-GEA (gastroenteroanastomosis). Outcomes of interest were technical success, clinical success, and rate of adverse events (AEs) in patients undergoing double treatment in the same session or within one week. RESULTS: 11 studies were included in the systematic review for a total number of 337 patients, 150 of whom had concurrent MBO and MGOO treatment, fulfilling the time criteria. MGOO was treated by duodenal stenting (self-expandable metal stents) in 10 studies, and in one study by EUS-GEA. EUS-BD had a mean technical success of 96.4% (CI 95%, 92.18-98.99) and a mean clinical success of 84.96% (CI 95%, 67.99-96.26). The average frequency of AEs for EUS-BD was 28.73% (CI 95%, 9.12-48.33). Clinical success for duodenal stenting was 90% vs. 100% for EUS-GEA. CONCLUSIONS: EUS-BD could become the preferred drainage in the case of double endoscopic treatment of concomitant MBO and MGOO in the near future, with the promising EUS-GEA becoming a valid option for MGOO treatment in these patients.

13.
J Gastroenterol Hepatol ; 38(4): 584-589, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36582040

RESUMEN

BACKGROUND AND AIM: Dedicated studies evaluating the impact of COVID-19 on outcomes of pancreatobiliary IgG4 related disease (IgG4-RD) patients are scarce. Whether COVID-19 infection or vaccination would trigger IgG4-RD exacerbation remains unknown. METHODS: Pancreatobiliary IgG4-RD patients ≥ 18 years old with active follow-up since January 2020 from nine referral centers in Asia, Europe, and North America were included in this multicenter retrospective study. Outcome measures include incidence and severity of COVID-19 infection, IgG4-RD disease activity and treatment status, interruption of indicated IgG4-RD treatment. Prospective data on COVID-19 vaccination status and new COVID-19 infection during the Omicron outbreak were also retrieved in the Hong Kong cohort. RESULTS: Of the 124 pancreatobiliary IgG4-RD patients, 25.0% had active IgG4-RD, 71.0% were on immunosuppressive therapies and 80.6% had ≥ 1 risk factor for severe COVID. In 2020 (pre-vaccination period), two patients (1.6%) had COVID-19 infection (one requiring ICU admission), and 7.2% of patients had interruptions in indicated immunosuppressive treatment for IgG4-RD. Despite a high vaccination rate (85.0%), COVID-19 infection rate has increased to 20.0% during Omicron outbreak in the Hong Kong cohort. A trend towards higher COVID-19 infection rate was noted in the non-fully vaccinated/unvaccinated group (17.6% vs 33.3%, P = 0.376). No IgG4-RD exacerbation following COVID-19 vaccination or infection was observed. CONCLUSION: While a low COVID-19 infection rate with no mortality was observed in pancreatobiliary IgG4-RD patients in the pre-vaccination period of COVID-19, infection rate has increased during the Omicron outbreak despite a high vaccination rate. No IgG4-RD exacerbation after COVID-19 infection or vaccination was observed.


Asunto(s)
COVID-19 , Enfermedad Relacionada con Inmunoglobulina G4 , Humanos , Adolescente , Estudios Retrospectivos , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19 , Estudios Prospectivos , Inmunoglobulina G , Vacunación , Hong Kong/epidemiología
16.
Gastrointest Endosc ; 96(5): 780-786, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35690150

RESUMEN

BACKGROUND AND AIMS: OverStitch devices (OverStitch and OverStitch Sx; Apollo Endosurgery, Inc, Austin, Tex, USA) are used for a wide range of applications. A European registry was created to prospectively collect technical and clinical data regarding both systems to provide procedural outcomes and to find correlation between procedural characteristics and outcomes. This study shows the initial results of the first 3 years of the registry. METHODS: Patients who underwent endoscopic suturing from January 2018 to January 2021 at 9 centers were enrolled. Data regarding the disease treated,suturing pattern and outcomes were registered. Technical feasibility (success reaching the target area), technical success (success placing sutures), and clinical success (complete resolution of the clinical issue) were recorded and analyzed. RESULTS: During the study period, 137 patients (57.7% men) were enrolled with 100% technical feasibility rate. Endoscopic suturing was successfully performed in 136 cases (16.7% with OverStitch Sx), obtaining a technical success rate of 99.3%. No adverse events were recorded. Overall clinical success was 89%. Mucosal defects were sutured in 32 patients (100% clinical success). Leaks/fistulas were treated in 23 patients (64.7% clinical success). The clinical success of stent fixations (n = 38) was 85%. Perforations (n = 22) were repaired with a clinical success of 94.7%. No significant correlation between location, suture pattern or number, and the success was found, except in case of fistulas where fistulas <1 cm treated by a continuous suture were more likely to achieve clinical success in the follow-up (P < .001). CONCLUSIONS: OverStitch-based suturing is technically feasible regardless of site and method of suturing, with no cases of failure. The overall technical success rate of 99.3% and the clinical outcome success rate of 89% demonstrate that OverStitch technology provides reliable suturing with clinical advantages, especially with fistulas <1 cm.


Asunto(s)
Técnicas de Sutura , Suturas , Masculino , Humanos , Femenino , Estudios Prospectivos , Endoscopía/métodos , Sistema de Registros , Resultado del Tratamiento
17.
Eur J Gastroenterol Hepatol ; 34(7): 757-762, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35482928

RESUMEN

BACKGROUND AND AIM: Intraparenchymal lung masses inaccessible through bronchoscopy or endobronchial ultrasound guidance pose a diagnostic challenge. Furthermore, some fragile or hypoxic patients may be poor candidates for transbronchial approaches. Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/FNB) offers a potential diagnostic approach to lung cancers adjacent to the esophagus. We aimed to evaluate the feasibility, accuracy, and safety of trans-esophageal EUS-FNA/FNB for tissue sampling of pulmonary nodules. METHODS: We retrospectively analyzed data from patients with pulmonary lesions who underwent EUS-FNA/FNB between March 2015 and August 2021 at eight Italian endoscopic referral centers. RESULTS: A total of 47 patients (36 male; mean age 64.47 ± 9.05 years) were included (22 EUS-FNAs and 25 EUS-FNBs). Overall diagnostic accuracy rate was 88.9% (76.3-96.2%). The sensitivity and diagnostic accuracy were superior for EUS FNB sampling versus EUS-FNA (100% vs. 78.73%); P = 0.05, and (100% vs. 78.57%); P = 0.05, respectively. Additionally, sample adequacy was superior for EUS-FNB sampling versus EUS-FNA (100% vs. 78.5%); P = 0.05. Multivariate logistic regression analysis for diagnostic accuracy showed nodule size at the cutoff of 15 mm (OR 2.29, 1.04-5.5, P = 0.05) and use of FNB needle (OR 4.33, 1.05-6.31, P = 0.05) as significant predictors of higher diagnostic accuracy. There were no procedure-related adverse events. CONCLUSION: This study highlights the efficacy and safety of EUS-FNA/FNB as a minimally invasive procedure for diagnosing and staging peri-esophageal parenchymal lung lesions. The diagnostic yield of EUS-FNB was superior to EUS-FNA.


Asunto(s)
Neoplasias Pancreáticas , Anciano , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/efectos adversos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Endosonografía/efectos adversos , Humanos , Pulmón , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/patología , Estudios Retrospectivos
19.
World J Gastrointest Endosc ; 14(2): 77-84, 2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35316982

RESUMEN

Exposed endoscopic full-thickness resection (EFTR), with or without laparoscopic assistance, is an emergent natural orifice transluminal endoscopic surgery technique with promising safety and efficacy for the management of gastrointestinal submucosal tumors (SMTs) arising from the muscularis propria (MP), especially of the gastric wall. To date, evidence concerning duodenal exposed EFTR is lacking, mainly due to both the technical difficulty involved because of the special duodenal anatomy and concerns about safety and effectiveness of transmural wall defect closure. However, given the non-negligible morbidity and mortality associated with duodenal surgery, the recent availability of dedicated endoscopic tools for tissue-approximation capable to realize full-thickness defect closure could help in promoting the adoption of this endosurgical technique among referral centers. The aim of our study was to review the current evidence concerning exposed EFTR with or without laparoscopic assistance for the treatment of MP-arising duodenal SMTs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...