Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Comput Assist Tomogr ; 40(5): 692-700, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27560010

RESUMEN

PURPOSE: The aim of this study was to investigate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in evaluation of blood flow changes related to transarterial chemoembolization (TACE) and radiofrequency ablation (RFA) procedures in patients with hepatocellular carcinoma (HCC) lesions. METHODS: Fifty-four patients, with biopsy-proven HCC, who underwent TACE or RFA, were evaluated, 1 month after treatment, with upper abdominal MRI examination. Multiplanar T2-weighted, T1-weighted, and dynamic contrast-enhanced sequences were acquired. Dedicated perfusion software (T1 Perfusion Package, Viewforum; Philips Medical Systems, The Netherlands) was used to generate color permeability maps. After placing regions of interest in normal hepatic parenchyma, in successfully treated lesions, and in area of recurrence, the following perfusion parameters were calculated and statistically analyzed: relative arterial, venous, and late enhancement; maximum enhancement; maximum relative enhancement, and time to peak. RESULTS: Twenty-one of 54 patients had residual disease, and perfusion parameters values measured within tumor tissue were: relative arterial enhancement median, 42%; relative venous enhancement median, 69%; relative late enhancement median, 57.7%; maximum enhancement median, 749.6%; maximum relative enhancement median, 69%; time to peak median, 81.1 seconds. As for all the evaluated parameters, a significant difference (P < 0.05) was found between residual viable tumor tissue and effective treated lesions. CONCLUSIONS: Dynamic contrast-enhanced MRI represents a complementary noninvasive tool that may offer quantitative and qualitative information about HCC lesions treated with TACE and RFA.


Asunto(s)
Carcinoma Hepatocelular/fisiopatología , Carcinoma Hepatocelular/terapia , Circulación Hepática , Neoplasias Hepáticas/fisiopatología , Neoplasias Hepáticas/terapia , Angiografía por Resonancia Magnética/métodos , Anciano , Velocidad del Flujo Sanguíneo , Carcinoma Hepatocelular/diagnóstico por imagen , Ablación por Catéter/métodos , Quimioembolización Terapéutica/métodos , Medios de Contraste , Femenino , Gadolinio DTPA , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
2.
Eur J Radiol ; 85(1): 268-273, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26526900

RESUMEN

PURPOSE: To compare radiation dose, image quality and diagnostic performance of low dose CT enterography (CTE) protocol combined with iterative reconstruction algorithm (iDose(4)) with standard dose CTE in follow-up of patients with known Crohn's disease (CD). MATERIALS AND METHOD: Thirty-six patients (12 females), with CD underwent a low-dose CTE scan during single venous phase on 256 MDCT scanner, with the following parameters: 120 kV, automated mAs dose-modulation, slice thickness 2mm and iDose(4) iterative reconstruction algorithm. A control group of thirty-seven patients underwent standard dose CTE examination on the same CT scanner. Two radiologists, blinded to clinical and pathological findings, independently evaluated in each scan, HU values in bowel wall and any presence of CD activity features and disease complications. Image noise and diagnostic quality were evaluated using a 4-point scale. Dose-length product (DLP) and CT-dose-index (CTDI) were recorded and data from both examinations were compared and statistically analyzed. RESULTS: Low-dose CTE protocol showed high diagnostic quality in assessment of Crohn's disease obtaining significantly (p ≤ 0.001) lower values of DLP and CTDI (604.98 mGy*cm and 12.29 mGy) as compared to standard dose examinations (974.85 mGy*cm and 19.71 mGy), with an overall dose reduction of 37.6%. Noise resulted slightly higher in iDose(4) images (SD=15.97) than in standard dose ones (SD=13.61) but this difference was not statistically significant (p=0.064). CONCLUSION: Low-dose CTE combined with iDose(4) reconstruction algorithm offers high quality images with significant reduction of radiation dose, and therefore can be considered a useful tool in the management of CD patients, considering their young age and the frequent imaging follow-up required.


Asunto(s)
Algoritmos , Enfermedad de Crohn/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Femenino , Estudios de Seguimiento , Humanos , Intestinos/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
3.
Gastroenterol Res Pract ; 2015: 630273, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26064093

RESUMEN

Purpose. To assess the diagnostic accuracy of dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSCE-MRI) in differentiation between benign and malignant liver lesions by assessment of tumoral perfusion parameters. Methods Materials. Seventy-three patients with known focal liver lesions, including 45 benign (16 FNH, 27 angiomas, and 2 abscesses) and 28 malignant ones (17 metastases, 9 HCCs, and 2 cholangiocarcinoma) underwent 1.5 T MRI upper abdominal study, with standard protocol that included dynamic contrast-enhanced sequences. On dedicated workstation, time-intensity curves were determined and the following perfusion parameters were calculated: relative arterial, venous and late enhancement (RAE, RVE, RLE), maximum enhancement (ME), relative enhancement (RE), and time to peak (TTP). Results. All diagnoses were established either by histopathology or imaging follow-up. Perfusion mean values calculated in benign lesions were RAE 33.8%, RVE 66.03%, RLE 80.63%, ME 776.00%, MRE 86.27%, and TTP 146.95 sec. Corresponding perfusion values calculated in malignant lesions were RAE 22.47%, RVE 40.54%, RLE 47.52%, ME 448.78%, MRE 49.85%, and TTP 183.79 sec. Statistical difference (p < 0.05) was achieved in all the perfusion parameters calculated, obtaining different cluster of perfusion kinetics between benign and malignant lesions. Conclusions. DSCE-MRI depicts kinetic differences in perfusion parameters among the different common liver lesions, related to tumour supply and microvascular characteristics.

4.
World J Radiol ; 7(12): 509-20, 2015 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-26753066

RESUMEN

AIM: To assess the clinical diagnostic value of functional imaging, combining quantitative parameters of apparent diffusion coefficient (ADC) and standardized uptake value (SUV)max, before and after chemo-radiation therapy, in prediction of tumor response of patients with rectal cancer, related to tumor regression grade at histology. METHODS: A total of 31 patients with biopsy proven diagnosis of rectal carcinoma were enrolled in our study. All patients underwent a whole body (18)FDG positron emission tomography (PET)/computed tomography (CT) scan and a pelvic magnetic resonance (MR) examination including diffusion weighted (DW) imaging for staging (PET1, RM1) and after completion (6.6 wk) of neoadjuvant treatment (PET2, RM2). Subsequently all patients underwent total mesorectal excision and the histological results were compared with imaging findings. The MR scanning, performed on 1.5 T magnet (Philips, Achieva), included T2-weighted multiplanar imaging and in addition DW images with b-value of 0 and 1000 mm²/s. On PET/CT the SUVmax of the rectal lesion were calculated in PET1 and PET2. The percentage decrease of SUVmax (ΔSUV) and ADC (ΔADC) values from baseline to presurgical scan were assessed and correlated with pathologic response classified as tumor regression grade (Mandard's criteria; TRG1 = complete regression, TRG5 = no regression). RESULTS: After completion of therapy, all the patients were submitted to surgery. According to the Mandard's criteria, 22 tumors showed complete (TRG1) or subtotal regression (TRG2) and were classified as responders; 9 tumors were classified as non responders (TRG3, 4 and 5). Considering all patients the mean values of SUVmax in PET 1 was higher than the mean value of SUVmax in PET 2 (P < 0.001), whereas the mean ADC values was lower in RM1 than RM2 (P < 0.001), with a ΔSUV and ΔADC respectively of 60.2% and 66.8%. The best predictors for TRG response were SUV2 (threshold of 4.4) and ADC2 (1.29 × 10(-3) mm(2)/s) with high sensitivity and specificity. Combining in a single analysis both the obtained median value, the positive predictive value, in predicting the different group category response in related to TRG system, presented R(2) of 0.95. CONCLUSION: The functional imaging combining ADC and SUVmax in a single analysis permits to detect changes in cellular tissue structures useful for the assessment of tumour response after the neoadjuvant therapy in rectal cancer, increasing the sensitivity in correct depiction of treatment response than either method alone.

5.
Eur J Radiol ; 82(2): 234-40, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23122748

RESUMEN

PURPOSE: To evaluate the diagnostic performance of quantitative apparent diffusion coefficient (ADC) measurements, in the assessment of the therapeutic response to chemo-radiation therapy (CRT) in patients with locally advanced rectal cancer, by analyzing post CRT values of ADC, in relation to tumor regression grade (TRG) obtained by histopathologic evaluation of the rectal specimen. METHODS: This prospective study was approved by an Institutional Review Board, and informed consent was obtained from all patients. Thirty-one patients with locally advanced rectal cancer underwent pre and post CRT MR imaging at 1.5T. ADC values were measured in regions of interest (ROIs) drawn independently by two radiologists, blinded to the pathology results, on three slices of the pre and post CRT DW-MR image sets with the corresponding T2 weighted images (T2WI) available for anatomic reference. The two readers' measurements were compared for differences in ADC values, inter-observer variability (measured as the intraclass correlation coefficient; ICC) and the ADC distributions of responders vs non-responders. The diagnostic performance of ADC in the prediction of the response to CRT was evaluated by calculating the area under the ROC curve (AUC) and the optimal cut-off values. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were assessed. RESULTS: The two readers showed an overall strong agreement in measuring ADC values. For both readers, no differences in ADC pre-treatment measurements were observed between responders and non-responders. For reader 1, the post-CRT ADC and the ΔADC presented the higher AUC (0.823 and 0.803, respectively), while Δ%ADC provided the lower AUC value (0.682). The optimal cutoff point was 1.294 s/mm(2) for post-CRT measures (sensitivity=86.4%, specificity=66.7%, PPV=86.4%, NPV=66.7%), 0.500 for ΔADC (sensitivity=81.8%, specificity=66.7%, PPV=85.7%, NPV=60.0%) and 59.3% for Δ%ADC (sensitivity=63.4%, specificity=66.7, PPV=82.4%, NPV=42.9%). Similar results were observed for reader 2, with better performance obtained with the ADC post-CRT (AUC of 0.833) and an optimal cut off of 1.277 × 10(-3)s/mm(2). CONCLUSION: Post-CRT ADC measurements are reliable and reproducible and may be used as a non-invasive tool to evaluate response to therapy as post-CRT ADC values and ΔADC presented good diagnostic performance to select responder patients.


Asunto(s)
Algoritmos , Quimioradioterapia , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias del Recto/patología , Neoplasias del Recto/terapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA