Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Orthopadie (Heidelb) ; 2024 Aug 22.
Artículo en Alemán | MEDLINE | ID: mdl-39172176

RESUMEN

BACKGROUND: Abnormal angular and torsional alignment of the lower extremities during growth are a common reason for consultation of a paediatrician or orthopaedist. There is often uncertainty about the pathological value of these abnormalities and the need for treatment, even among specialists. In the course of physiological growth and development processes, the axial and torsional alignment of the legs sometimes change considerably and in characteristic patterns. DIAGNOSTICS: The ability to assess whether abnormal angular or torsional alignments of the lower limb in the course of growth should still be regarded as normal or already as pathological, depending on age and gender, is essential for the treating physician and requires precise knowledge of the physiological development processes and the tolerable limits in all three spatial dimensions. TREATMENT: After careful explanation to the frequently concerned parents, a restrictive approach with observation of the spontaneous course of correction on the basis of regular clinical check-ups makes sense in the majority of cases. Pathological deviations from the physiological conditions are rare overall, can be idiopathic or of secondary origin and should be further clarified diagnostically using imaging procedures. As conservative measures are ineffective, pronounced angular and/or torsional deformities of the legs requiring treatment can only be corrected by surgical intervention, even in children and adolescents. The surgical treatment modalities available are varied and differ in terms of their invasiveness and complication profile, depending on the localization, type and severity of the deformity, as well as the age and possible concomitant diseases of the affected child or adolescent.

2.
Acta Orthop ; 95: 364-372, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007719

RESUMEN

BACKGROUND AND PURPOSE: Magnetically controlled motorized intramedullary lengthening nails (ILNs) can be employed for simultaneous correction of angular deformities of the distal femur and leg length discrepancy. This spares typical complications of external fixators but requires precise preoperative planning and exact intraoperative execution. To date, its results are insufficiently reported. We aimed to elucidate the following questions: (i) Is acute angular deformity correction and gradual femoral lengthening via a retrograde ILN a reliable and precise treatment option? (ii) What are the most common complications of treatment? METHODS: Acute angular deformity correction and subsequent gradual lengthening of the distal femur with retrograde ILN was retrospectively analyzed in 45 patients (median patient age: 15 years, interquartile range [IQR] 13-19 and median follow-up: 40 months, IQR 31-50). Outcome parameters were accuracy, precision, reliability, bone healing, and complications of treatment. RESULTS: The median distraction was 46 mm (IQR 29-49), median distraction and consolidation index 0.9 mm/day (IQR 0.7-1.0) and 29 days/cm (IQR 24-43), respectively. The median preoperative mechanical axis deviation (MAD) was 30 mm (IQR 23-39) in the varus cohort and -25 mm (IQR -29 to -15) in the valgus cohort and reduced to a mean of 8 mm (standard deviation [SD] 8) and -3 (SD 10), respectively. Accuracy, precision, and reliability of lengthening were 94%, 95% and 96%, respectively. Accuracy and precision of deformity correction were 92% and 89%, respectively. In total, 40/45 of patients achieved distraction with a difference of less than 1 cm from the initial plan and a postoperative MAD ranging from -10 mm to +15 mm. In 13/45 patients unplanned additional surgeries were conducted to achieve treatment goal with nonunion being the most frequent (4/45) and knee subluxation (3/45) the most severe complication. CONCLUSION: Acute deformity correction and subsequent lengthening of the distal femur with retrograde ILN is a reliable and accurate treatment achieving treatment goal in 89% but unplanned additional surgeries in 29% of patients should be anticipated.


Asunto(s)
Clavos Ortopédicos , Fémur , Diferencia de Longitud de las Piernas , Humanos , Diferencia de Longitud de las Piernas/cirugía , Diferencia de Longitud de las Piernas/etiología , Estudios Retrospectivos , Masculino , Femenino , Adolescente , Fémur/cirugía , Fémur/anomalías , Alargamiento Óseo/métodos , Alargamiento Óseo/instrumentación , Resultado del Tratamiento , Adulto Joven , Osteogénesis por Distracción/métodos , Osteogénesis por Distracción/efectos adversos , Estudios de Seguimiento
3.
Orthopadie (Heidelb) ; 52(9): 719-728, 2023 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-37561147

RESUMEN

For paediatric orthopaedic surgeons treating leg length discrepancy, knowledge of the available procedures and their options and limits is just as important as mastery of the very different surgical methods and implants, as well as the possible complications, in order to be able to advise and treat the children and adolescents and their parents comprehensively and in the best interests. Both the growth inhibiting procedures and the complex bone lengthening procedures require a great deal of experience to successfully guide patients and families through what is often a lengthy and sometimes complicated treatment process. Careful preoperative indications and planning, precise surgical techniques with suitable instruments and implants, and attentive postoperative check-ups are mandatory prerequisites for the desired therapeutic success.


Asunto(s)
Alargamiento Óseo , Ortopedia , Adolescente , Humanos , Niño , Pierna/cirugía , Alargamiento Óseo/efectos adversos , Diferencia de Longitud de las Piernas/cirugía , Prótesis e Implantes/efectos adversos
4.
Bone Joint Res ; 10(7): 425-436, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34269599

RESUMEN

AIMS: This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. METHODS: This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors' institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed. RESULTS: Adjacent to the nail's telescoping junction, osteolytic changes were observed in bi-planar radiographs of 20/57 segments (35%) after a mean of 9.5 months (95% confidence interval 7.2 to 11.9) after surgery. A total of 8/20 patients with osseous alterations (40%) reported rest and ambulation pain of the lengthened segment during consolidation. So far, 24 Stryde nails were retrieved and in 20 (83%) macroscopic corrosion was observed at the nail's telescoping junction. Before implant removal 11/20 radiographs (55%) of lengthened segments with these 20 nails revealed osteolysis. Implant retrieval analysis by means of SEM showed pitting and crevice corrosion. EDX detected chromium as the main metallic element of corrosion. CONCLUSION: Patients are exposed to the risk of implant-related osteolysis of unclear short- and long-term clinical consequences. The authors advocate in favour of an early implant removal after osseous consolidation. Cite this article: Bone Joint Res 2021;10(7):425-436.

5.
Acta Orthop ; 85(3): 293-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24758320

RESUMEN

BACKGROUND AND PURPOSE: The PRECICE intramedullary limb lengthening system uses a new technique with a magnetic rod and a motorized external remote controller (ERC) with rotational magnetic field. We evaluated the reliability and safety of the PRECICE system. METHODS: We compared our preliminary results with PRECICE in 24 patients (26 nails) with the known difficulties in the use of mechanical lengthening devices such as the ISKD. We used the Paley classification for evaluation of problems, obstacles, and complications. RESULTS: 2 nails were primarily without function, and 24/26 nails lengthened over the desired distance. Lengthening desired was 38 mm and lengthening obtained was 37 mm. There were 2 nail breakages, 1 in the welding seam and 1 because of a fall that occurred during consolidation. ERC usage was problematic mostly in patients with femoral lengthening. Adjustment of the ERC was necessary in 10 of 24 cases. 15 cases had implant-associated problems, obstacles were seen in 5 cases, and complications were seen in each of 4 cases. INTERPRETAION: The reliability of the PRECICE system is comparable to that of other intramedullary lengthening devices such as the ISKD. The motorized external remote controller and its application by the patients is a weak point of the system and needs strict supervision.


Asunto(s)
Alargamiento Óseo/instrumentación , Alargamiento Óseo/métodos , Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Tibia/cirugía , Adolescente , Adulto , Clavos Ortopédicos , Niño , Falla de Equipo , Equipos y Suministros , Femenino , Humanos , Incidencia , Magnetismo , Masculino , Seguridad del Paciente , Reproducibilidad de los Resultados , Adulto Joven
6.
J Pediatr Orthop ; 31(4): 393-401, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21572277

RESUMEN

BACKGROUND: In patients with multiple cartilaginous exostosis, distal ulnar osteochondromas frequently cause forearm deformities, with relative ulnar shortening, wrist joint deviation, and varus bowing. Progressive deformation often leads to pain, functional impairment, and cosmetic problems. Surgical ulnar lengthening is necessary to restore the carpal balance. The results of fixator-controlled ulnar lengthening were investigated in this study, using appropriate clinical and radiologic parameters and focusing on medium-term functional and structural outcomes. METHODS: Twelve children (3 boys, 9 girls; mean age 9.8 y) with multiple cartilaginous exostosis-induced ulnar shortening treated with fixator-controlled ulnar callotasis were evaluated retrospectively based on clinical and radiographic examinations preoperatively, after fixator removal, and at a follow-up investigation. Subjective symptoms and objective joint function were assessed clinically, whereas the extent of ulnar shortening, radial articular angle, carpal slip, and radial head dislocation were determined radiographically. RESULTS: The average follow-up period was 24.6 months. The mean ulnar shortening and radial articular angle improved significantly, from 14.3 mm or 38.7 degrees preoperatively to 1.7 mm or 25.6 degrees after fixator removal and showed a slight but significant increase to 5.2 mm or 30.1 degrees at the follow-up. Carpal slip and radial head dislocation remained unchanged. With the exception of radial abduction, no notable functional advancement was observed. One unintended ulnar overlengthening with a subsequent ulnocarpal impaction syndrome, one premature callus consolidation, and two fixator dislocations were noted. CONCLUSIONS: In agreement with literature reports, carpal balance can be restored over the medium term. However, mild recurrences of ulnar shortening and radial malformation were observed during further development. To prevent deformity progression in immature patients, surgery should be carried out early. The optimal timing of surgery needs to be calculated precisely to take advantage of the high remodeling potential and an acceptable degree of recurrent deformity. Ulnar lengthening is necessary, but overcorrection is inadvisable due to possible ulnocarpal impaction syndrome. As significant remodeling effects on the radius were observed, simultaneous radial correction procedures are not recommended a priori.


Asunto(s)
Exostosis Múltiple Hereditaria/cirugía , Antebrazo/cirugía , Osteogénesis por Distracción/métodos , Cúbito/cirugía , Adolescente , Niño , Preescolar , Exostosis Múltiple Hereditaria/complicaciones , Exostosis Múltiple Hereditaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Antebrazo/anomalías , Antebrazo/diagnóstico por imagen , Humanos , Masculino , Radiografía , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/patología , Estudios Retrospectivos , Cúbito/anomalías , Cúbito/diagnóstico por imagen
7.
Am J Sports Med ; 35(2): 228-34, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17099239

RESUMEN

BACKGROUND: This research was undertaken to determine whether there is a need for a second tibial tunnel in anatomic anterior cruciate ligament reconstruction. HYPOTHESIS: Anatomic two-bundle reconstruction with two tibial tunnels restores knee anterior tibial translation in response to 134 N and to 5-N.m internal tibial torque combined with 10-N.m valgus torque more closely to normal than does double-bundle reconstruction with one tibial tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: Ten cadaveric knees were subjected to a 134-N anterior tibial load at 0 degrees, 30 degrees, 60 degrees, and 90 degrees and to 5-N.m internal tibial torque and 10-N.m valgus torque at 15 degrees and 30 degrees. Resulting knee kinematics and in situ force in the anterior cruciate ligament or replacement graft were determined by using a robotic/universal force-moment sensor testing system for (1) intact, (2) anterior cruciate ligament-deficient, (3) double-bundle/one tibial tunnel, and (4) double-bundle/two tibial tunnels. RESULTS: Anterior tibial translation for the reconstruction with two tibial tunnels was significantly closer to that of the intact knee than was the reconstruction with one tibial tunnel at 0 degrees and 30 degrees of flexion (0 degrees = 3.82 vs 6.0 mm, P < .05; 30 degrees = 7.99 vs 11 mm, P < .05). The in situ force normalized to the intact anterior cruciate ligament for the reconstruction with two tibial tunnels was significantly higher than the in situ force of the reconstruction with one tibial tunnel (30 degrees = 89 vs 82 N, P < .05). With a combined rotatory load, the anterior tibial translation of specimens with a tibial two-tunnel technique was significantly lower than that of specimens with one tunnel (0 degrees = 5.7 vs 8.4 mm, P < .05; 30 degrees = 7.5 vs 9.5 mm, P < .05). CONCLUSIONS: Anatomic reconstruction with two tibial tunnels may produce a better biomechanical outcome, especially close to extension. CLINICAL RELEVANCE: At the time of initial fixation, there appears to be a small biomechanical advantage to the second tibial tunnel in the setting of two-bundle anterior cruciate ligament reconstruction.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Articulación de la Rodilla/fisiopatología , Tendones/trasplante , Tenodesis/métodos , Muslo , Tibia/cirugía , Anciano , Ligamento Cruzado Anterior/fisiopatología , Lesiones del Ligamento Cruzado Anterior , Cadáver , Humanos , Persona de Mediana Edad , Modelos Biológicos , Rango del Movimiento Articular/fisiología , Robótica , Soporte de Peso/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...