Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Abdom Radiol (NY) ; 49(3): 964-974, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38175255

RESUMEN

PURPOSE: To evaluate robustness of a radiomics-based support vector machine (SVM) model for detection of visually occult PDA on pre-diagnostic CTs by simulating common variations in image acquisition and radiomics workflow using image perturbation methods. METHODS: Eighteen algorithmically generated-perturbations, which simulated variations in image noise levels (σ, 2σ, 3σ, 5σ), image rotation [both CT image and the corresponding pancreas segmentation mask by 45° and 90° in axial plane], voxel resampling (isotropic and anisotropic), gray-level discretization [bin width (BW) 32 and 64)], and pancreas segmentation (sequential erosions by 3, 4, 6, and 8 pixels and dilations by 3, 4, and 6 pixels from the boundary), were introduced to the original (unperturbed) test subset (n = 128; 45 pre-diagnostic CTs, 83 control CTs with normal pancreas). Radiomic features were extracted from pancreas masks of these additional test subsets, and the model's performance was compared vis-a-vis the unperturbed test subset. RESULTS: The model correctly classified 43 out of 45 pre-diagnostic CTs and 75 out of 83 control CTs in the unperturbed test subset, achieving 92.2% accuracy and 0.98 AUC. Model's performance was unaffected by a three-fold increase in noise level except for sensitivity declining to 80% at 3σ (p = 0.02). Performance remained comparable vis-a-vis the unperturbed test subset despite variations in image rotation (p = 0.99), voxel resampling (p = 0.25-0.31), change in gray-level BW to 32 (p = 0.31-0.99), and erosions/dilations up to 4 pixels from the pancreas boundary (p = 0.12-0.34). CONCLUSION: The model's high performance for detection of visually occult PDA was robust within a broad range of clinically relevant variations in image acquisition and radiomics workflow.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Resiliencia Psicológica , Humanos , Adenocarcinoma/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Radiómica , Flujo de Trabajo , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Automático , Estudios Retrospectivos
2.
PLoS One ; 18(11): e0294564, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38011131

RESUMEN

BACKGROUND: Pancreatic ductal adenocarcinoma (PDAC) is a lethal disease prone to widespread metastatic dissemination and characterized by a desmoplastic stroma that contributes to poor outcomes. Fibroblast activation protein (FAP)-expressing Cancer-Associated Fibroblasts (CAFs) are crucial components of the tumor stroma, influencing carcinogenesis, fibrosis, tumor growth, metastases, and treatment resistance. Non-invasive tools to profile CAF identity and function are essential for overcoming CAF-mediated therapy resistance, developing innovative targeted therapies, and improved patient outcomes. We present the design of a multicenter phase 2 study (clinicaltrials.gov identifier NCT05262855) of [68Ga]FAPI-46 PET to image FAP-expressing CAFs in resectable or borderline resectable PDAC. METHODS: We will enroll up to 60 adult treatment-naïve patients with confirmed PDAC. These patients will be eligible for curative surgical resection, either without prior treatment (Cohort 1) or after neoadjuvant therapy (NAT) (Cohort 2). A baseline PET scan will be conducted from the vertex to mid-thighs approximately 15 minutes after administering 5 mCi (±2) of [68Ga]FAPI-46 intravenously. Cohort 2 patients will undergo an additional PET after completing NAT but before surgery. Histopathology and FAP immunohistochemistry (IHC) of initial diagnostic biopsy and resected tumor samples will serve as the truth standards. Primary objective is to assess the sensitivity, specificity, and accuracy of [68Ga]FAPI-46 PET for detecting FAP-expressing CAFs. Secondary objectives will assess predictive values and safety profile validation. Exploratory objectives are comparison of diagnostic performance of [68Ga]FAPI-46 PET to standard-of-care imaging, and comparison of pre- versus post-NAT [68Ga]FAPI-46 PET in Cohort 2. CONCLUSION: To facilitate the clinical translation of [68Ga]FAPI-46 in PDAC, the current study seeks to implement a coherent strategy to mitigate risks and increase the probability of meeting FDA requirements and stakeholder expectations. The findings from this study could potentially serve as a foundation for a New Drug Application to the FDA. TRIAL REGISTRATION: @ClinicalTrials.gov identifier NCT05262855.


Asunto(s)
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Adulto , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/patología , Radioisótopos de Galio , Adenocarcinoma/tratamiento farmacológico , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/tratamiento farmacológico , Tomografía de Emisión de Positrones , Fibroblastos/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18/uso terapéutico , Estudios Multicéntricos como Asunto , Ensayos Clínicos Fase II como Asunto , Neoplasias Pancreáticas
3.
Gastroenterology ; 165(6): 1533-1546.e4, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37657758

RESUMEN

BACKGROUND & AIMS: The aims of our case-control study were (1) to develop an automated 3-dimensional (3D) Convolutional Neural Network (CNN) for detection of pancreatic ductal adenocarcinoma (PDA) on diagnostic computed tomography scans (CTs), (2) evaluate its generalizability on multi-institutional public data sets, (3) its utility as a potential screening tool using a simulated cohort with high pretest probability, and (4) its ability to detect visually occult preinvasive cancer on prediagnostic CTs. METHODS: A 3D-CNN classification system was trained using algorithmically generated bounding boxes and pancreatic masks on a curated data set of 696 portal phase diagnostic CTs with PDA and 1080 control images with a nonneoplastic pancreas. The model was evaluated on (1) an intramural hold-out test subset (409 CTs with PDA, 829 controls); (2) a simulated cohort with a case-control distribution that matched the risk of PDA in glycemically defined new-onset diabetes, and Enriching New-Onset Diabetes for Pancreatic Cancer score ≥3; (3) multi-institutional public data sets (194 CTs with PDA, 80 controls), and (4) a cohort of 100 prediagnostic CTs (i.e., CTs incidentally acquired 3-36 months before clinical diagnosis of PDA) without a focal mass, and 134 controls. RESULTS: Of the CTs in the intramural test subset, 798 (64%) were from other hospitals. The model correctly classified 360 CTs (88%) with PDA and 783 control CTs (94%), with a mean accuracy 0.92 (95% CI, 0.91-0.94), area under the receiver operating characteristic (AUROC) curve of 0.97 (95% CI, 0.96-0.98), sensitivity of 0.88 (95% CI, 0.85-0.91), and specificity of 0.95 (95% CI, 0.93-0.96). Activation areas on heat maps overlapped with the tumor in 350 of 360 CTs (97%). Performance was high across tumor stages (sensitivity of 0.80, 0.87, 0.95, and 1.0 on T1 through T4 stages, respectively), comparable for hypodense vs isodense tumors (sensitivity: 0.90 vs 0.82), different age, sex, CT slice thicknesses, and vendors (all P > .05), and generalizable on both the simulated cohort (accuracy, 0.95 [95% 0.94-0.95]; AUROC curve, 0.97 [95% CI, 0.94-0.99]) and public data sets (accuracy, 0.86 [95% CI, 0.82-0.90]; AUROC curve, 0.90 [95% CI, 0.86-0.95]). Despite being exclusively trained on diagnostic CTs with larger tumors, the model could detect occult PDA on prediagnostic CTs (accuracy, 0.84 [95% CI, 0.79-0.88]; AUROC curve, 0.91 [95% CI, 0.86-0.94]; sensitivity, 0.75 [95% CI, 0.67-0.84]; and specificity, 0.90 [95% CI, 0.85-0.95]) at a median 475 days (range, 93-1082 days) before clinical diagnosis. CONCLUSIONS: This automated artificial intelligence model trained on a large and diverse data set shows high accuracy and generalizable performance for detection of PDA on diagnostic CTs as well as for visually occult PDA on prediagnostic CTs. Prospective validation with blood-based biomarkers is warranted to assess the potential for early detection of sporadic PDA in high-risk individuals.


Asunto(s)
Carcinoma Ductal Pancreático , Diabetes Mellitus , Neoplasias Pancreáticas , Humanos , Inteligencia Artificial , Estudios de Casos y Controles , Detección Precoz del Cáncer , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Carcinoma Ductal Pancreático/diagnóstico por imagen , Estudios Retrospectivos
4.
Pancreatology ; 23(5): 522-529, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37296006

RESUMEN

OBJECTIVES: To develop a bounding-box-based 3D convolutional neural network (CNN) for user-guided volumetric pancreas ductal adenocarcinoma (PDA) segmentation. METHODS: Reference segmentations were obtained on CTs (2006-2020) of treatment-naïve PDA. Images were algorithmically cropped using a tumor-centered bounding box for training a 3D nnUNet-based-CNN. Three radiologists independently segmented tumors on test subset, which were combined with reference segmentations using STAPLE to derive composite segmentations. Generalizability was evaluated on Cancer Imaging Archive (TCIA) (n = 41) and Medical Segmentation Decathlon (MSD) (n = 152) datasets. RESULTS: Total 1151 patients [667 males; age:65.3 ± 10.2 years; T1:34, T2:477, T3:237, T4:403; mean (range) tumor diameter:4.34 (1.1-12.6)-cm] were randomly divided between training/validation (n = 921) and test subsets (n = 230; 75% from other institutions). Model had a high DSC (mean ± SD) against reference segmentations (0.84 ± 0.06), which was comparable to its DSC against composite segmentations (0.84 ± 0.11, p = 0.52). Model-predicted versus reference tumor volumes were comparable (mean ± SD) (29.1 ± 42.2-cc versus 27.1 ± 32.9-cc, p = 0.69, CCC = 0.93). Inter-reader variability was high (mean DSC 0.69 ± 0.16), especially for smaller and isodense tumors. Conversely, model's high performance was comparable between tumor stages, volumes and densities (p > 0.05). Model was resilient to different tumor locations, status of pancreatic/biliary ducts, pancreatic atrophy, CT vendors and slice thicknesses, as well as to the epicenter and dimensions of the bounding-box (p > 0.05). Performance was generalizable on MSD (DSC:0.82 ± 0.06) and TCIA datasets (DSC:0.84 ± 0.08). CONCLUSION: A computationally efficient bounding box-based AI model developed on a large and diverse dataset shows high accuracy, generalizability, and robustness to clinically encountered variations for user-guided volumetric PDA segmentation including for small and isodense tumors. CLINICAL RELEVANCE: AI-driven bounding box-based user-guided PDA segmentation offers a discovery tool for image-based multi-omics models for applications such as risk-stratification, treatment response assessment, and prognostication, which are urgently needed to customize treatment strategies to the unique biological profile of each patient's tumor.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Masculino , Humanos , Persona de Mediana Edad , Anciano , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Redes Neurales de la Computación , Neoplasias Pancreáticas/diagnóstico por imagen , Carcinoma Ductal Pancreático/diagnóstico por imagen , Conductos Pancreáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...