Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
J Trace Elem Med Biol ; 69: 126891, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34749033

RESUMEN

OBJECTIVE: To examine associations between local and systemic symptoms and the wear of the tin weld of Essure implants. DESIGN: study of a series of cases. SETTINGS: Two French hospitals. PARTICIPANTS: Eighteen patients explanted by hysterectomy and salpingectomy for removal of their Essure implants between September 2019 and July 2020, have had a common anatomopathological process. MAIN OUTCOME MEASURES: anatomopathological examination by optical microscopy and mineralogical analysis of the fallopian tube or uterine horn with scanning electron microscopy coupled with energy dispersive X-ray (SEM-EDX). Evaluation of local and systemic symptoms with a questionnaire. Examination of blood metal assays (nickel, chromium, and tin). RESULTS: anatomopathological examination highlights foreign body granulomas, fibrosis, adenomyosis, nonspecific inflammation, cysts and myomas in the Fallopian tubes, uterine horns, or both and mentions the presence of foreign bodies in seven cases. SEM-EDX analyses showed, systematically, the presence of tin particles integrated in the wall near the weld, generally in clusters, and with a size ranging from about one micron to several dozen microns. The questionnaire shows that the most frequent local symptoms were pelvic pain, urinary disorders, bleeding, and pains during intercourse. The most common systemic symptoms were: asthenia, visual disturbances, amnesia, giddiness, dorsal pains, headaches, and joint pains. The majority of local and systemic symptoms decreased after explantation, but sometimes incompletely. Before explantation, high levels of nickel, tin and chromium were observed in 11/17, 1/7 and 2/17 patients. After explantation, tin levels were high in 3/11 patients. CONCLUSIONS: our new anatomopathological process systematically demonstrates the presence of tin particles in tissue near the weld. These particles could be responsible for granulomatous inflammations as well as local symptoms. Many of the systemic symptoms are consistent with chronic organotin poisoning but further studies are needed to find out whether tin from the solder can be converted to organotin in the patients' bodies.


Asunto(s)
Trompas Uterinas , Esterilización Tubaria , Cromo , Femenino , Humanos , Níquel , Estaño
3.
J Biomech Eng ; 143(3)2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33067629

RESUMEN

The periodontal biomechanical environment is very difficult to investigate. By the complex geometry and composition of the periodontal ligament (PDL), its mechanical behavior is very dependent on the type of loading (compressive versus tensile loading; static versus cyclic loading; uniaxial versus multiaxial) and the location around the root (cervical, middle, or apical). These different aspects of the PDL make it difficult to develop a functional biomaterial to treat periodontal attachment due to periodontal diseases. This review aims to describe the structural and biomechanical properties of the PDL. Particular importance is placed in the close interrelationship that exists between structure and biomechanics: the PDL structural organization is specific to its biomechanical environment, and its biomechanical properties are specific to its structural arrangement. This balance between structure and biomechanics can be explained by a mechanosensitive periodontal cellular activity. These specifications have to be considered in the further tissue engineering strategies for the development of an efficient biomaterial for periodontal tissues regeneration.


Asunto(s)
Ligamento Periodontal , Fenómenos Biomecánicos
4.
Eur Cell Mater ; 37: 1-15, 2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30614513

RESUMEN

In the context of shoulder surgical replacement, a new generation of spherical interposition implants has been developed, with the implant being a mobile spacer rubbing against the glenoid cartilage and humeral bone cavity. The aim of the present study was to compare pyrocarbon (PyC) versus cobalt-chromium (CoCr) implants, regarding preservation and regeneration of the surrounding tissues. The effect of the biomaterials on chondrocytes was analysed in vitro. Murine primary chondrocytes were grown on discs made of PyC or CoCr using two culture media to mimic either cartilage-like or bone-like conditions (CLC or BLC). Chondrocytes did grow on PyC and CoCr without alteration in cell viability or manifestation of cytotoxicity. The tissue-like cell membranes grown under BLC were examined for the chondrocyte's ability to mineralise (by alizarin red matrix staining, calcium deposit and alkaline phosphatase activity) and for their mechanical properties (by rheological tests). For the chondrocytes grown under CLC and BLC, extracellular matrix components were analysed by histological staining and immunolabelling. Under CLC, PyC promoted type II collagen expression in chondrocytes, suggesting that they may generate a more cartilage-like matrix than samples grown on both CoCr and plastic control. In BLC, the tissue-like cell membranes grown on PyC were more mineralised and homogenous. The mechanical results corroborated the biological data, since the elastic modulus of the tissue-like cell membranes developed on the PyC surface was higher, indicating more stiffness. Overall, the results suggested that PyC might be a suitable biomaterial for spherical interposition implants.


Asunto(s)
Carbono/farmacología , Condrocitos/citología , Aleaciones de Cromo/farmacología , Prótesis e Implantes , Animales , Materiales Biocompatibles/farmacología , Huesos/citología , Calcificación Fisiológica/efectos de los fármacos , Cartílago/citología , Membrana Celular/efectos de los fármacos , Membrana Celular/metabolismo , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Condrocitos/efectos de los fármacos , Condrocitos/metabolismo , Matriz Extracelular/efectos de los fármacos , Matriz Extracelular/metabolismo , Ratones , Reproducibilidad de los Resultados , Reología
5.
Biochim Biophys Acta Gen Subj ; 1861(12): 3109-3119, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28899829

RESUMEN

BACKGROUND: Considering the importance of cellular mechanics in the birth and evolution of cancer towards increasingly aggressive stages, we compared nano-mechanical properties of non-tumoral (WPMY-1) and highly aggressive metastatic (PC-3) prostate cell lines both on cell aggregates, single cells, and membrane lipids. METHODS: Cell aggregate rheological properties were analyzed during dynamic compression stress performed on a homemade rheometer. Single cell visco-elasticity measurements were performed by Atomic Force Microscopy using a cantilever with round tip on surface-attached cells. At a molecular level, the lateral diffusion coefficient of total extracted lipids deposited as a Langmuir monolayer on an air-water interface was measured by the FRAP technique. RESULTS: At cellular pellet scale, and at single cell scale, PC-3 cells were less stiff, less viscous, and thus more prone to deformation than the WPMY-1 control. Interestingly, stress-relaxation curves indicated a two-step response, which we attributed to a differential response coming from two cell elements, successively stressed. Both responses are faster for PC-3 cells. At a molecular scale, the dynamics of the PC-3 lipid extracts are also faster than that of WPMY-1 lipid extracts. CONCLUSIONS: As the evolution of cancer towards increasingly aggressive stages is accompanied by alterations both in membrane composition and in cytoskeleton dynamical properties, we attribute differences in viscoelasticity between PC-3 and WPMY-1 cells to modifications of both elements. GENERAL SIGNIFICANCE: A decrease in stiffness and a less viscous behavior may be one of the diverse mechanisms that cancer cells adopt to cope with the various physiological conditions that they encounter.


Asunto(s)
Neoplasias de la Próstata/patología , Biomarcadores , Línea Celular Tumoral , Citoesqueleto/fisiología , Difusión , Elasticidad , Recuperación de Fluorescencia tras Fotoblanqueo , Humanos , Masculino , Microscopía de Fuerza Atómica , Persona de Mediana Edad , Metástasis de la Neoplasia , Estrés Mecánico , Viscosidad
6.
Eur Phys J E Soft Matter ; 37(8): 28, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25149067

RESUMEN

This study shows the interactions of charged particles with mixed supported lipid bilayers (SLB) as biomimetic pulmonary surfactants. We tested two types of charged particles: positively charged and negatively charged particles. Two parameters were measured: adsorption density of particles on the SLB and the diffusion coefficient of lipids by FRAPP techniques as a measure of interaction strength between particles and lipids. We found that positively charged particles do not adsorb on the bilayer, probably due to the electrostatic repulsion between positively charged parts of the lipid head and the positive groups on the particle surface, therefore no variation in diffusion coefficient of lipid molecules was observed. On the contrary, the negatively charged particles, driven by electrostatic interactions are adsorbed onto the supported bilayer. The adsorption of negatively charged particles increases with the zeta-potential of the particle. Consecutively, the diffusion coefficient of lipids is reduced probably due to binding onto the lipid heads which slows down their Brownian motion. The results are directly relevant for understanding the interactions of particulate matter with pulmonary structures which could lead to pulmonary surfactant inhibition or deficiency causing severe respiratory distress or pathologies.


Asunto(s)
Biomimética , Membrana Dobles de Lípidos/química , Material Particulado/química , Surfactantes Pulmonares/química , Electricidad Estática , Adsorción , Difusión , Movimiento (Física)
8.
Colloids Surf B Biointerfaces ; 80(2): 232-9, 2010 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-20634046

RESUMEN

We have investigated the mechanical and tribological properties of supported Dioleoyl phosphatidylcholine (DOPC) bilayers in different solutions: ultrapure water (pH 5.5), saline solution (150 mM NaCl, pH 5.8), Tris buffer (pH 7.2) and Tris saline buffer (150 mM NaCl, pH 7.2). Friction forces are measured using a homemade biotribometer. Lipid bilayer degradation is controlled in situ during friction tests using fluorescence microscopy. Mechanical resistance to indentation is measured by force spectroscopy with an atomic force microscope. This study confirms that mechanical stability under shear or normal load is essential to obtain low and constant friction coefficients. In ultrapure water, bilayers are not resistant and have poor lubricant properties. On the other hand, in Tris saline buffer, they fully resist to indentation and exhibit low (micro=0.035) and stable friction coefficient with no visible wear during the 50 min of the friction test. The unbuffered saline solution improves the mechanical resistance to indentation but not the lubrication. These results suggest that the adsorption of ions to the zwiterrionic bilayers has different effects on the mechanical and tribological properties of bilayers: higher resistance to normal indentation due to an increase in bilayer cohesion, higher lubrication due to an increase in bilayer-bilayer repulsion.


Asunto(s)
Iones/química , Membrana Dobles de Lípidos/química , Fosfolípidos/química , Fenómenos Biomecánicos , Microscopía de Fuerza Atómica , Microscopía Fluorescente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...