Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 12243, 2024 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-38806607

RESUMEN

Stress shielding and aseptic loosening are complications of short stem total hip arthroplasty, which may lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective in reducing stress shielding, however, there is a lack of research on optimized porous distribution in stem's coating. This study aimed to optimize the distribution of the coefficient of friction of a metaphyseal femoral stem, aiming for reducing stress shielding in the proximal area. A finite element analysis model of an implanted, titanium alloy short-tapered wedge stem featuring a porous coating made of titanium was designed to simulate a static structural analysis of the femoral stem's behavior under axial loading in Analysis System Mechanical Software. For computational feasibility, 500 combinations of coefficients of friction were randomly sampled. Increased strains in proximal femur were found in 8.4% of the models, which had decreased coefficients of friction in middle medial areas of porous coating and increased in lateral proximal and lateral and medial distal areas. This study reported the importance of the interface between bone and middle medial and distal lateral areas of the porous coating in influencing the biomechanical behavior of the proximal femur, and potentially reducing stress shielding.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fémur , Análisis de Elementos Finitos , Fricción , Prótesis de Cadera , Titanio , Humanos , Fémur/fisiología , Porosidad , Artroplastia de Reemplazo de Cadera/métodos , Titanio/química , Estrés Mecánico , Diseño de Prótesis , Materiales Biocompatibles Revestidos/química , Fenómenos Biomecánicos , Aleaciones/química
2.
Materials (Basel) ; 17(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38473577

RESUMEN

Composites, and especially carbon-fiber-reinforced plastics (CFRPs), are increasingly used in the automotive, aerospace, and aviation industries, and as a result, CFRP production has increased dramatically, leading to a corresponding increase in waste. Landfills and the incineration of waste are likely to be restricted as a result of legislation, thus highlighting the need for efficient recycling methods for CFRPs. However, the recycling of CFRPs is very challenging, mainly due to the difficulty of removing their thermosetting matrix. This study reports a pre-screening of the solvolysis recycling process for CFRPs based on the mechanical properties of the recovered fibers. To this end, solvolysis tests were conducted on unidirectional CFRP samples under supercritical and subcritical conditions using acetone and water. The solvolysis tests were conducted for various conditions of temperature, pressure, and reaction time, without the use of any catalyst. Also, the loading rate (volume of solvent/volume of reactor) was constant. The efficiency of the recycling processes has been evaluated through a morphological and a mechanical characterization of the recovered fibers. In most cases, the decomposition efficiency of the epoxy resin, measured in terms of mass, ranged between 90 and 100%. Moreover, the scanning electron microscopy images of the recovered fibers showed negligible traces of resin residues and no detectable signs of physical damage or any changes in morphology with regard to diameter. Finally, the single-fiber tension tests revealed that that the recovered fibers retained more than 61% of their initial Young's modulus and 70% of their tensile strength.

3.
Materials (Basel) ; 17(2)2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38255529

RESUMEN

Thermoplastic composites are continuously replacing thermosetting composites in lightweight structures. However, the accomplished work on the fatigue behavior of thermoplastics is quite limited. In the present work, we propose a numerical modeling approach for simulating fatigue delamination growth and predicting the residual tensile strength of quasi-isotropic TC 1225 LM PAEK thermoplastic coupons. The approach was supported and validated by tension and fatigue (non-interrupted and interrupted) tests. Fatigue delamination growth was simulated using a mixed-mode fatigue crack growth model, which was based on the cohesive zone modeling method. Quasi-static tension analyses on pristine and fatigued coupons were performed using a progressive damage model. These analyses were implemented using a set of Hashin-type strain-based failure criteria and a damage mechanics-based material property degradation module. Utilizing the fatigue model, we accurately foretold the expansion of delamination concerning the cycle count across all interfaces. The results agree well with C-scan images taken on fatigued coupons during interruptions of fatigue tests. An unequal and unsymmetric delamination growth was predicted due to the quasi-isotropic layup. Moreover, the combined models capture the decrease in the residual tensile strength of the coupons. During the quasi-static tension analysis of the fatigued coupons, we observed that the primary driving failure mechanisms were the rapid spread of existing delamination and the consequential severe matrix cracking.

4.
J Orthop Surg Res ; 18(1): 542, 2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37507795

RESUMEN

BACKGROUND: Hip fractures are an increasingly common consequence of falls in older people that are associated with a high risk of death and reduced function. The vast majority of intertrochanteric fractures require surgical treatment to withstand early mobilization and weight bearing, which prevents complications due to prolonged bed rest and aids in fracture healing. METHODS: This study is compromised by two parts, the experimental study and the clinical part. In the first part, a standard 130° nail will be used with the appropriate lag screw(s) and dynamic distal locking in synthetic osteoporotic femurs and the transmission of forces in the proximal femur, measured by a cortical surface-strain distribution, will be evaluated using digital image correlation. Finite element parametric models of the bone, the nails and their interface will be also developed. Finite element computations of surface strains in implanted femurs, after being validated against biomechanical testing measurements, will be used to assist the comparison of the nails by deriving important data on the developed stress and strain fields, which cannot be measured through biomechanical testing. In the other part, will set up a prospective, randomized, comparative clinical study among the Gamma3 and IT cephalomedullary nailing, in order to investigate if there are any statistical important differences in the main radiological measurements and functional status in closed unstable intertrochanteric fractures (A21-3) in patients aged over 70 years old at the 24-week follow-up evaluation using patient reported disease-specific outcomes. DISCUSSION: This study will be the first to compare clinical, radiological and biomechanical measurements of the two different cephalomedullary nails. Our main hypothesis is that the IT nail would provide better radiological outcome and probably better clinical results than the Gama3 nail. Clinical trial registration International Standard Randomized Controlled Trial Number (ISRCTN): https://doi.org/10.1186/ISRCTN15588442 , registered on 19/4/2022.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Anciano , Anciano de 80 o más Años , Preescolar , Fijación Intramedular de Fracturas/métodos , Análisis de Elementos Finitos , Clavos Ortopédicos , Estudios Prospectivos , Tornillos Óseos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto
5.
Materials (Basel) ; 15(15)2022 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-35897540

RESUMEN

In the present work, a numerical model based on the cohesive zone modeling (CZM) approach has been developed to simulate mixed-mode fracture of co-consolidated low melt polyaryletherketone thermoplastic laminates by considering fiber bridging. A modified traction separation law of a tri-linear form has been developed by superimposing the bi-linear behaviors of the matrix and fibers. Initially, the data from mode I (DCB) and mode II (ENF) fracture toughness tests were used to construct the R-curves of the joints in the opening and sliding directions. The constructed curves were incorporated into the numerical models employing a user-defined material subroutine developed in the LS-Dyna finite element (FE) code. A numerical method was used to extract the fiber bridging law directly from the simulation results, thus eliminating the need for the continuous monitoring of crack opening displacement during testing. The final cohesive model was implemented via two identical FE models to simulate the fracture of a Single-Lap-Shear specimen, in which a considerable amount of fiber bridging was observed on the fracture area. The numerical results showed that the developed model presented improved accuracy in comparison to the CZM with the bi-linear traction-separation law (T-SL) in terms of the predicted strength of the joint.

6.
Materials (Basel) ; 15(10)2022 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-35629451

RESUMEN

In this paper, analytical and numerical models have been developed to compute the stress field and predict fracture of the aluminum/epoxy interface subjected to laser shock loading, in the frame of the investigation of the paint stripping process. An explicit finite element (FE) model combined with the cohesive zone modeling (CZM) method, an analytical stress analysis model, and a spall fracture model have been developed. The numerical model has been calibrated and validated against tests in terms of the stripping pattern, while the analytical models have been compared with the numerical model. The models were combined to generate computational tools for decreasing computational effort. The FE model with the CZM is the most accurate tool although it is the most computationally expensive. The spall fracture model gives trusted estimations of the spall strength of the interface which are very sensitive to the interface thickness and when incorporated into a continuum FE-based damage model can predict the stripping initiation faster than the FE model with the CZM. The analytical stress analysis model can be used to efficiently describe the shock wave propagation into the material system, but it can give only a rough estimation of the tensile stress at the epoxy, which when combined with the spall strength does not give reliable predictions of the stripping initiation. The three models require as input different material properties, some of which are very difficult to determine. Nevertheless, the availability of accurate material parameters and properties of the aluminum, the epoxy, and, especially, their interface can significantly improve the efficiency of the developed models.

7.
Sensors (Basel) ; 20(6)2020 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-32192068

RESUMEN

The increasing utilization of carbon fiber reinforced plastic (CFRP) in the aeronautical industry calls for a structural health monitoring (SHM) system for adhesively bonded CFRP joints. Optical glass fiber with inscribed fiber Bragg gratings (FBGs) is a promising technology for a SHM system. This paper investigates the intrusive effect of embedding optical glass fibers carrying FBGs on adhesive bond strength and adhesive layer thickness and quality. Embedding the optical glass fibers directly in the adhesive bond has the advantage of directly monitoring the targeted structure but poses the risk of significantly reducing the bond strength. Optical glass fibers with different cladding diameters (50, 80, 125 µm) and coating types (polyimide, with a thickness of 3-8 µm, and acrylate, with a thickness of ~35 µm) are embedded in structural and repair film adhesives here. Without embedded optical glass fibers, the film adhesives have an adhesive layer thickness of ~90 µm (structural) and ~100 µm (repair) after curing. The intrusive effect of the fiber embedding on the adhesive bond strength is investigated here with quasi static and fatigue single lap joint (SLJ) tensile shear tests. Also, the influence of hydrothermal aging procedures on the quasi static tensile shear strength is investigated. It is found that optical glass fibers with a total diameter (glass fiber cladding + coating) of ~145 µm significantly reduce the quasi static tensile shear strength and increase the adhesive layer thickness and number of air inclusions (or pores) in the structural film adhesive joints. In the repair adhesive joints, no significant reduction of quasi static tensile shear strength is caused by the embedding of any of the tested fiber types and diameters. However, an increase in the adhesive layer thickness is detected. In both adhesive films, no effect on the quasi-static tensile shear strength is detected when embedding optical glass fibers with total diameters <100 µm. The applied aging regime only affects the repair film adhesive joints, and the structural film adhesive joints show no significant reduction. A polyimide-coated 80 µm optical glass fiber is selected for fatigue SLJ tensile shear tests in combination with the more sensitive structural film adhesive. No significant differences between the S-N curves and tensile shear fatigue strength of the reference samples without embedded optical fibers and the samples carrying the polyimide-coated 80 µm optical glass fibers are detected. Thus, it is concluded that the influences of embedding optical glass fibers with total diameters <100 µm on the fatigue limit of the tested film adhesive joints is negligible.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...