Artículo en Inglés | MEDLINE | ID: mdl-38573538

RESUMEN

BACKGROUND: The TactiFlex SE catheter (TFSE, Abbott) with a contact force (CF) sensor and a laser-cut irrigated-tip has recently become available but lacks a lesion quality marker. This study aimed to explore distinctions in lesion characteristics between the TFSE and the ThermoCool SmartTouch SurroundFlow catheter (STSF, Biosense Webster), which utilizes a porous irrigated tip, and to assess the most effective application settings for the TFSE. METHODS: Lesions were generated using varying settings of radiofrequency power (30-50 W), CF (10-20 g), application duration (10-40 s), and catheter orientation (perpendicular or parallel) in an ex vivo porcine model. Comparative analysis between the TFSE and STSF was conducted for lesion characteristics and incidence of steam pops using predictive models in regression analyses. RESULTS: Among 720 applications, the TFSE exhibited a significantly lower incidence of steam pops compared to the STSF (0.6% vs. 36.8%, P < 0.001). Moreover, coefficients of determination (R2) for the TFSE were higher than those for the STSF concerning lesion depth (0.710 vs. 0.541) and volume (0.723 vs. 0.618). The lesion size generated with the TFSE was notably smaller than that with the STSF under identical application settings. Additionally, to achieve a lesion depth ≥ 4.0 mm, the TFSE required an application duration 8-12 s longer than the STSF under similar settings. CONCLUSIONS: The TFSE demonstrated a lower incidence of steam pops and superior predictability in lesion size compared to the STSF. However, the TFSE necessitated a longer application duration than the STSF to achieve an adequate lesion size.

2.
Pacing Clin Electrophysiol ; 45(11): 1299-1302, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35675325

RESUMEN

Septal coronary artery fistula is a rare but concerning complication of left bundle branch area pacing (LBBAP). We report the case of an 82-year-old man who was indicated for cardiac resynchronization therapy and underwent LBBAP. The patient had no chest symptoms during or after implantation. Postoperative echocardiography demonstrated a new abnormal tunnel inside the interventricular septum (IVS) and shunt flow from the IVS toward the right ventricle. Coronary angiography confirmed a septal coronary artery fistula, which might have been formed by failed deep screw attempts. Since the shunt volume assessed by the Qp /Qs was small, the patient was treated conservatively.


Asunto(s)
Terapia de Resincronización Cardíaca , Fístula , Masculino , Humanos , Anciano de 80 o más Años , Fascículo Atrioventricular , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Bloqueo de Rama/diagnóstico , Estimulación Cardíaca Artificial/métodos , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía/métodos , Terapia de Resincronización Cardíaca/métodos
3.
JACC Clin Electrophysiol ; 8(1): 59-69, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34454880

RESUMEN

OBJECTIVES: This study aimed to compare acute hemodynamic improvements and responses to His bundle pacing (HBP) and conventional biventricular pacing (BVP). BACKGROUND: HBP can correct left bundle branch block (LBBB) and may be an alternative cardiac resynchronization therapy (CRT) to BVP. METHODS: Fourteen consecutive patients with heart failure (HF) and typical LBBB who required CRT were enrolled. The acute hemodynamic responses during HBP and BVP were compared using a micromanometer-tipped catheter inserted into the left ventricle (LV) before CRT. Each configuration was compared with AAI mode. A permanent HBP device was implanted when LBBB correction threshold was ≤1.5 V at 1.0 ms, and remaining patients were treated with BVP. Clinical and echocardiographic improvements were assessed during a 12-month follow-up period. RESULTS: The LV contractile index (positive maximal rate of LV pressure rise [dP/dtmax]) increased similarly during HBP and BVP (18.8% ± 6.4% vs 18.0% ± 10.2%; P = 0.810). LV relaxation indices (negative dP/dtmax and tau) were significantly improved during HBP compared with BVP (negative dP/dtmax: 14.3% ± 5.5% vs 3.1% ± 8.1%; P < 0.001; tau: 7.2% ± 4.3% vs -0.8% ± 8.1%; P = 0.001). Nine (64%) patients received permanent HBP devices, while 5 patients were treated with BVP. The New York Heart Association functional class, LV ejection fraction, LV end-systolic volume, and B-type natriuretic peptide level improved in patients treated with HBP and BVP (all P < 0.05 vs baseline). Patients treated with HBP exhibited earlier and greater improvements of the LV ejection fraction and LV end-systolic volume than did those with BVP. CONCLUSIONS: HBP improves systolic function and LV relaxation in patients with HF and LBBB. CRT via HBP produced earlier and greater clinical responses than BVP.


Asunto(s)
Bloqueo de Rama , Insuficiencia Cardíaca , Fascículo Atrioventricular , Bloqueo de Rama/terapia , Electrocardiografía , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Resultado del Tratamiento
4.
Pacing Clin Electrophysiol ; 44(11): 1907-1917, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34520042

RESUMEN

BACKGROUND: Permanent His-bundle pacing (HBP) is effective and safe; however, the success rate of HBP is low, especially in patients with infranodal block. This study aimed to assess the efficacy and feasibility of HBP implantation using an electrophysiological guided approach targeting a distal His-bundle electrogram (HBE) in patients with atrioventricular block (AVB). METHODS: Thirty-four consecutive patients with AVB (infranodal block in 28 patients) who underwent HBP were enrolled. During implantation, we attempted to target the distal part of the HBE (distal HBE) beyond the block site based on unipolar mapping. The His-capture threshold was evaluated for 1 year after implantation. RESULTS: HBP was achieved in 26 patients and in 21 patients (75%) with infranodal block. Detection of distal HBE was significantly higher in the successful HBP group than in the HBP failure group (65.4% vs. 0%, p = .001). Among 15 patients with intra-Hisian block, 14 patients (93%) successfully achieved HBP with distal HBE detection. During the 1-year follow-up period, an increase in His-capture threshold by ≥1.0 V at 1.0 ms occurred in five (19.2%) of 26 patients. The increased His-capture threshold group exhibited significantly less detection of distal HBE (20% vs. 76.2%; odds ratio 0.078, 95% confidence interval 0.07-0.87, p = .038) and a higher His-capture threshold at implantation (2.0 ± 1.1 V vs. 1.1 ± 0.9 V; odds ratio 1.702, 95% confidence interval 1.025-2.825, p = 0.04) than the non-increased His-capture threshold group. CONCLUSION: HBP implantation guided by distal HBE approach may be feasible with subsequent stable pacing in patients with intra-Hisian and atrioventricular nodal block.


Asunto(s)
Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Técnicas Electrofisiológicas Cardíacas , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino
5.
Pacing Clin Electrophysiol ; 43(11): 1412-1416, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32548908

RESUMEN

Evaluations of His bundle pacing (HBP) lead location at autopsy examination have been rarely reported. We report an autopsy case of a 98-year-old man who underwent HBP implantation due to atrioventricular block and heart failure. Although selective HBP was achieved with an acceptable threshold, the stimulus-to-QRS interval was relatively longer without correction of the right bundle-branch block. A macroscopic examination revealed that the HBP lead was inserted on the ventricular side passing through the anteroseptal commissure of the tricuspid valve. Transthyretin cardiac amyloidosis may affect the distal conduction system resulting in a long stimulus-to-QRS interval during selective HBP.


Asunto(s)
Bloqueo Atrioventricular/terapia , Fascículo Atrioventricular/fisiopatología , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Anciano de 80 o más Años , Amiloidosis/diagnóstico , Autopsia , Cardiomiopatías/diagnóstico , Electrocardiografía , Resultado Fatal , Humanos , Masculino
6.
Circ J ; 84(7): 1118-1123, 2020 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-32448844

RESUMEN

BACKGROUND: Integrated device diagnostics, Triage-HF, is useful in risk stratifying patients with heart failure (HF), but its performance for Japanese patients remains unknown. This is a prospective study of Japanese patients treated with a cardiac resynchronization therapy defibrillator (CRT-D), with a Medtronic OptiVol 2.0 feature.Methods and Results:A total of 320 CRT-D patients were enrolled from 2013 to 2017. All received HF treatment in the prior 12 months. Following enrollment, they were followed every 6 months for 48 months (mean, 22 months). Triage-HF-stratified patients at low, medium and high risk statuses at every 30-day period, and HF-related hospitalization occurring for the subsequent 30 days, were evaluated and repeated. The primary endpoint was to assess Triage-HF performance in predicting HF-related hospitalization risk. All device data were available for 279 of 320 patients (NYHA class II or III in 93%; mean left ventricular ejection fraction, 31%). During a total of 5,977 patient-month follow-ups, 89 HF-related hospitalization occurred in 72 patients. The unadjusted event numbers for Low, Medium and High statuses were 19 (0.7%), 42 (1.6%) and 28 (4.1%), respectively. Relative risk of Medium to Low status was 2.18 (95% CI 1.23-3.85) and 5.78 (95% CI 3.34-10.01) for High to Low status. Common contributing factors among the diagnostics included low activity, OptiVol threshold crossing, and elevated night heart rate. CONCLUSIONS: Triage-HF effectively stratified Japanese patients at risk of HF-related hospitalization.


Asunto(s)
Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/diagnóstico , Telemetría/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Japón , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Vigilancia de Productos Comercializados , Estudios Prospectivos , Medición de Riesgo , Resultado del Tratamiento , Triaje
7.
Pacing Clin Electrophysiol ; 37(11): 1544-52, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25113752

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) improves cardiac function, but CRT recipients with advanced heart failure (HF) do not always respond well. Because the best parameters for the prediction of CRT response are not established, we investigated whether improvement of invasive left ventricular (LV) hemodynamic diastolic parameters could identify CRT responders. METHODS: A total of 34 consecutive patients (age, 69 ± 9 years; 70% men) who received CRT devices for HF were assessed as to whether acute invasive hemodynamic parameters with and without CRT function could predict LV volume responders. RESULTS: These patients demonstrated an improvement in LV dP/dtmax (11.1 ± 11.7%), LV dP/dtmin (4.6 ± 12.1%), and tau (3.7 ± 11.6%) by biventricular pacing. Nineteen patients (55%) were classified as CRT responders, which was defined by a >15% decrease in LV end-systolic volume (ESV) at the 6-month follow-up evaluation. The area under the receiver operator characteristic curve to detect CRT volume response was 0.93 for the shortening of tau, which was superior to any other hemodynamic parameter. The multivariate analysis revealed that this improvement in tau was the strongest predictive factor for identifying CRT volume responders. Of note, the magnitude of tau shortening during biventricular pacing was significantly correlated with the reduction in LVESV at the 6-month follow-up evaluation. CONCLUSIONS: The extent of acute improvement in LV isovolumic relaxation time, as assessed by tau, was associated with favorable response to CRT. The assessment of invasive diastolic function could provide valuable information about CRT volume response.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hemodinámica , Función Ventricular Izquierda , Anciano , Diástole , Femenino , Humanos , Masculino , Proyectos Piloto , Pronóstico
8.
J Interv Card Electrophysiol ; 41(1): 83-90, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25027177

RESUMEN

INTRODUCTION: A difference in the lesion formation between open irrigated-tip (OITC) and non-irrigated 4-mm-tip catheters (NITC) may result in a difference in the dimension of the pulmonary vein (PV) ostia after PV isolation of atrial fibrillation (AF). This study evaluated the difference using intracardiac echocardiography (ICE) before and immediately after an extensive encircling PV isolation (EPVI) with an OITC and with an NITC. METHODS AND RESULTS: We studied 100 consecutive patients (OITC group, 54; NITC group, 46) who received EPVI. Changes in the vessel, lumen, and wall thickness areas of the PVs were evaluated at the PV ostia by ICE. There were no significant differences in the baseline characteristics and acute success rate of the EPVI between the OITC and NITC groups. The energy delivered to achieve EPVI was higher in the OITC group than that in the NITC group (34,967 ± 13,222 J vs. 28,300 ± 10,614 J; p=0.01). After the ablation, the reduction in the vessel and lumen cross-sectional areas was significantly smaller in the OITC group than that in the NITC group (-9.05 ± 28.4 % vs. -21.2 ± 28.8 %, p<0.001; -8.76 % vs. -17.7 ± 26.9 %, p=0.003). The wall thickness area slightly decreased in the OITC group, but increased in the NITC group (-2.96 ± 38.4 % vs. 10.5 ± 76.6 %, p=0.591). During a median follow-up of 234 days, there was no significant difference in the AF recurrence after the initial ablation procedure between the two groups. CONCLUSION: Greater PV ostial narrowing occurred with the NITC than OITC immediately after the EPVI. PV ostial wall edema was noted with only the NITC. These findings suggested that an OITC might reduce any acute PV narrowing and wall edema as compared with an NITC.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/patología , Ecocardiografía Transesofágica/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/patología , Ondas de Radio , Recurrencia , Resultado del Tratamiento
9.
J Cardiol ; 64(5): 347-52, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24679906

RESUMEN

BACKGROUND: Acute stent recoil has been often observed following stent delivery balloon deflation in coronary arteries and the recoil rate varies by stent design. Accordingly, the purpose of the present study was to evaluate the impact of stent designs on acute stent recoil after new generation drug-eluting stent implantation. METHODS AND RESULTS: A total of 154 lesions [56 treated with biolimus-eluting stent (BES), 46 with cobalt chromium everolimus-eluting stent (CoCr-EES), and 52 with platinum chromium everolimus-eluting stent (PtCr-EES)] were evaluated. Quantitative coronary angiography was used to measure the minimal lumen diameter (MLD). MLD1 was defined as a MLD of complete expansion of the last stent delivery balloon at the highest pressure. MLD2 was defined as a MLD immediately after the last stent delivery balloon deflation. Acute stent recoil was determined by the calculation as (MLD1-MLD2)/MLD1. Acute stent recoil was significantly higher in the CoCr-EES group versus the BES group and PtCr-EES group (10.1 ± 6.9%, 6.7 ± 5.5%, and 6.5 ± 4.8%, respectively, p = 0.01). Multivariate linear regression analysis demonstrated that the use of CoCr-EES and the number of stent delivery balloon inflations were independent predictors of acute stent recoil (r = 0.26, ß = 0.21, p = 0.01 and r = -0.51, ß = -0.58, p < 0.01, respectively). CONCLUSION: Acute stent recoil occurred more frequently with the CoCr-EES compared with both BES and PtCr-EES. Strategies with multiple balloon inflation might be needed to overcome this recoil phenomenon.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea , Diseño de Prótesis , Aleaciones de Cromo , Femenino , Humanos , Masculino , Compuestos de Platino , Estudios Retrospectivos , Acero Inoxidable
10.
Circ J ; 78(3): 601-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24366102

RESUMEN

BACKGROUND: The relationship between pulmonary vein (PV) potential (PVP) disappearance patterns during encircling ipsilateral pulmonary vein isolation (EIPVI) of atrial fibrillation (AF), and outcome was examined. METHODS AND RESULTS: A total of 352 consecutive AF patients (age, 61±12 years; 269 men, 76.4%; paroxysmal AF, n=239; persistent AF, n=73; and long-standing persistent AF, n=40) who underwent initial AF ablation were studied. After EIPVI with a double Lasso technique, pacing was performed from the PV carina to confirm isolation of the carina. PVP disappearance patterns were classified into 3 types: A, both superior and inferior PVP disappeared simultaneously; B, superior and inferior PVP disappeared separately; and C, additional RF applications were required inside the encircling lesions to eliminate the PVP after creating anatomical encircling lesions. The relationship between these patterns and outcome was examined. Six groups were defined according to the combination of right and left ipsilateral PVP disappearance patterns. The incidence of A-A, A-B, B-B, A-C, B-C, and C-C was 7.1%, 14.2%, 16.2%, 15.3%, 27.3%, and 19.9%, respectively. AF recurrence-free rate at 2 years for these 6 groups was 96%, 81%, 78%, 64%, 64%, and 59%, respectively (P<0.02). The incidence of a carina isolation was 153/154 (99.4%) for type A, 221/259 (85.3%) for type B, and 145/290 (50.0%) for type C. CONCLUSIONS: PVP disappearance pattern during EIPVI was significantly associated with the incidence of residual PV carina conduction and AF recurrence.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Venas Pulmonares/fisiopatología , Anciano , Fibrilación Atrial/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/patología , Estudios Retrospectivos
12.
Europace ; 15(1): 33-40, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22941967

RESUMEN

AIMS: Encircling ipsilateral pulmonary veins (PVs) isolation (EIPVsI) with the double-Lasso technique has proven to be effective to cure atrial fibrillation (AF). However, in this technique, PV mapping with circular catheters may miss a non-isolation of the PV carina. The purpose of this study was to reveal the incidence and clinical significance of a non-isolation of the PV carina after EIPVsI. METHODS AND RESULTS: We studied 81 consecutive paroxysmal AF patients (age 61 ± 12 years, 56 men), in whom EIPVsI was successfully performed in one encircling line with the endpoint of the demonstration of bidirectional conduction block between the PVs and left atrium (LA) with the double-Lasso technique. After a successful EIPVsI, pacing from the PV carina was performed and it captured the LA in 17 (21.0%) patients. During a mean follow-up period of 19 ± 13 months, AF recurred in 13 (16.0%) patients. A multivariate Cox proportional analysis revealed that a non-isolation of the PV carina after the EIPVsI was a significant predictor (hazard ratio = 3.91, 95% confidence interval = 1.13-14.16, P = 0.03) of AF recurrence. CONCLUSIONS: Pulmonary vein mapping with the double-Lasso technique did miss the non-isolation of the PV carina after a successful EIPVsI, which was an independent predictor of AF recurrence after the EIPVsI. Pacing from the PV carina may be required to confirm the electrical isolation of the PV carina after EIPVsI with the double-Lasso technique.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Ablación por Catéter/estadística & datos numéricos , Sistema de Conducción Cardíaco/cirugía , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Fibrilación Atrial/prevención & control , Mapeo del Potencial de Superficie Corporal/métodos , Femenino , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Factores de Riesgo , Prevención Secundaria , Insuficiencia del Tratamiento , Resultado del Tratamiento
13.
J Renin Angiotensin Aldosterone Syst ; 13(4): 487-95, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22634400

RESUMEN

INTRODUCTION: The purpose of this study was to investigate whether the effects of renin-angiotensin system inhibitors (RASIs) after encircling ipsilateral pulmonary veins isolation (EIPVsI) for atrial fibrillation (AF) differed between patients with non-dilated and dilated left atria. MATERIALS AND METHODS: We retrospectively studied 292 consecutive patients (mean age=61±11 years, 75% males) who underwent successful EIPVsI for paroxysmal or persistent AF. RASIs' effects were compared between the patients with a non-dilated left atrium of <40 mm (n=178) and dilated left atrium of ≥40 mm (n=114). RESULTS: During a mean follow-up period of 18.9±12.7 months, AF recurred in 38 (21.4%) and 45 (39.5%) patients with non-dilated and dilated left atria, respectively. A multivariate Cox proportional analysis revealed that treatment with RASIs (hazard ratio (HR) 0.30, 95% confidence interval (CI) =0.13-0.66, p=0.003), the duration of AF (HR 1.08/year, 95% CI=1.01-1.16, p=0.03), a history of hypertension (HR 2.86, 95% CI=1.21-6.85, p=0.02) and the left ventricular ejection fraction (HR 0.54/10%↑, 95% CI=0.34-0.87, p=0.01) were associated with AF recurrences in patients with a non-dilated left atrium. On the other hand, only the duration of AF (HR 1.11/year, 95% CI=1.01-1.21, p=0.03) was associated with AF recurrences in those with a dilated LA, and RASIs had no effect on AF recurrences (p=0.65). CONCLUSIONS: RASIs suppressed AF recurrences after EIPVsI only in patients with a non-dilated left atrium.


Asunto(s)
Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Atrios Cardíacos/fisiopatología , Venas Pulmonares/cirugía , Sistema Renina-Angiotensina/efectos de los fármacos , Antagonistas de Receptores de Angiotensina/farmacología , Inhibidores de la Enzima Convertidora de Angiotensina/farmacología , Fibrilación Atrial/fisiopatología , Procedimientos Quirúrgicos Cardiovasculares , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Atrios Cardíacos/efectos de los fármacos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Venas Pulmonares/efectos de los fármacos , Venas Pulmonares/fisiopatología , Recurrencia , Vasodilatación/efectos de los fármacos
15.
Europace ; 14(6): 915-7, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22199147

RESUMEN

A 56-year-old man with atrial fibrillation and complete left bundle branch block (CLBBB) developed heart failure refractory to the initial medical treatment. Both the CLBBB and cardiac dysfunction completely recovered only with an advanced medical regimen for rate control and heart failure. This report describes a case with reversible CLBBB following tachycardia-induced cardiomyopathy, who was not a candidate for cardiac resynchronization therapy.


Asunto(s)
Bloqueo de Rama/fisiopatología , Cardiomiopatías/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Taquicardia/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Bloqueo de Rama/diagnóstico , Cardiomiopatías/tratamiento farmacológico , Electrocardiografía , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Remisión Espontánea , Taquicardia/tratamiento farmacológico
16.
Pacing Clin Electrophysiol ; 34(3): 296-303, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21091729

RESUMEN

INTRODUCTION: An additional approach may be essential to reduce recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI). We examined the efficacy of renin-angiotensin system blockers (RAS-B) in suppressing AF recurrences after PVI. METHODS AND RESULTS: We retrospectively studied 264 consecutive patients (195 male, median age: 63 years) who underwent successful PVI of paroxysmal (n = 94) or persistent AF (n = 170). RAS-B treatment was performed in 145 patients (angiotensin-converting enzyme inhibitors; n = 13, angiotensin receptor blockers; n = 129, both; n = 3). Echocardiography was performed before and 3 months after the ablation to examine the occurrence of left atrial structural reverse remodeling (LA-RR). After a median follow-up of 195 (interquartile range: 95-316) days, AF recurred in 51 (19.3%) patients. A Cox regression analysis revealed that AF recurrence was significantly lower in the patients with RAS-B than in those without (hazard ratio [HR] = 0.41 [95% confidence interval (CI): 0.23-0.71], P = 0.002). After a multivariate adjustment for potential confounders, the use of RAS-B (HR = 0.39 [95% CI: 0.19-0.77], P = 0.007) and type of AF (HR = 0.30 [95% CI: 0.13-0.66], P = 0.003) were the independent predictors for AF recurrence during the entire follow-up. Although effect of RAS-B was not significant during the early follow-up (<3 month), it was the only independent predictor during the late follow-up (>3 months) (HR = 0.21 [95% CI: 0.08-0.53], P = 0.001). There were no significant differences in LA-RR occurrence regarding RAS-B medication. The use of RAS-B was an independent predictor of late AF recurrences irrespective of an early LA-RR occurrence. CONCLUSIONS: Treatment with RAS-B significantly reduced the AF recurrence after PVI. This benefit became more prominent 3 months after the PVI.


Asunto(s)
Inhibidores de la Enzima Convertidora de Angiotensina/administración & dosificación , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/epidemiología , Fibrilación Atrial/prevención & control , Ablación por Catéter/estadística & datos numéricos , Venas Pulmonares/cirugía , Anciano , Terapia Combinada/estadística & datos numéricos , Femenino , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Prevención Secundaria , Resultado del Tratamiento
17.
Clin Cardiol ; 33(12): E18-23, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21184541

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) has been reported to improve cardiac performance. However, CRT in patients with advanced heart failure is not always accompanied by an improvement in survival rates. We investigated the association between hemodynamic studies and long-term prognosis after CRT. METHODS: A total of 68 consecutive patients receiving CRT devices due to advanced heart failure were assessed by hemodynamic study and long-term outcome after implantation of the device. Hemodynamic parameters were measured both with the CRT on and off. RESULTS: Patients demonstrated significant improvement in the maximum first derivative of left ventricular (LV) pressure (LV dP/dt(max) ) and QRS duration after periods with the CRT on. During the follow-up period of 34.9 ± 17.6 months, basal LV dP/dt(max) and isovolemic LV pressure half-time (T½), but not percent change in LV dP/dt(max) , were independent predictors of cardiac mortality or hospitalization due to heart failure after multivariate Cox regression analysis. The Kaplan-Meier survival analysis revealed that patients in the lowest basal LV dP/dt(max) tertile or the longest basal T½ tertile exhibited a significantly higher cardiac-caused mortality or heart failure hospitalization. CONCLUSIONS: Lower LV dP/dt(max) or longer T½ independently predicts cardiac mortality or heart failure hospitalization in patients receiving CRT. The assessment of the basal LV dP/dt(max) and T½ could provide useful information in long-term prognosis after CRT.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda , Presión Ventricular , Anciano , Ecocardiografía Doppler , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Hospitalización/estadística & datos numéricos , Humanos , Japón , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
Europace ; 12(1): 96-102, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19762332

RESUMEN

AIMS: Managed ventricular pacing (MVP) and Search AV+ are representative dual-chamber pacing algorithms for minimizing ventricular pacing (VP). This randomized, crossover study aimed to examine the difference in ability to reduce percentage of VP (%VP) between these two algorithms. METHODS AND RESULTS: Symptomatic bradyarrhythmia patients implanted with a pacemaker equipped with both algorithms (Adapta DR, Medtronic) were enrolled. The %VPs of the patients during two periods were compared: 1 month operation of either one of the two algorithms for each period. All patients were categorized into subgroups according to the atrioventricular block (AVB) status at baseline: no AVB (nAVB), first-degree AVB (1AVB), second-degree AVB (2AVB), episodic third-degree AVB (e3AVB), and persistent third-degree AVB (p3AVB). Data were available from 127 patients for the analysis. For all patient subgroups, except for p3AVB category, the median %VPs were lower during the MVP operation than those during the Search AV+ (nAVB: 0.2 vs. 0.8%, P < 0.0001; 1AVB: 2.3 vs. 27.4%, P = 0.001; 2AVB: 16.4% vs. 91.9%, P = 0.0052; e3AVB: 37.7% vs. 92.7%, P = 0.0003). CONCLUSION: Managed ventricular pacing algorithm, when compared with Search AV+, offers further %VP reduction in patients implanted with a dual-chamber pacemaker, except for patients diagnosed with persistent loss of atrioventricular conduction.


Asunto(s)
Algoritmos , Bradicardia/diagnóstico , Bradicardia/prevención & control , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Terapia Asistida por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/prevención & control , Anciano , Bradicardia/complicaciones , Estudios Cruzados , Femenino , Humanos , Japón , Masculino , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología
19.
Circ J ; 73(4): 632-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19225201

RESUMEN

BACKGROUND: The relationship between vagal modification and paroxysmal atrial fibrillation (PAF) recurrence after segmental pulmonary vein (PV) isolation (S-PVI) was investigated. METHODS AND RESULTS: S-PVI was performed in 77 PAF patients using a multielectrode basket or circular catheter to achieve electrical disconnection of all 4 PVs independent of eliminating vagal reflexes. Serial Holter-recordings were obtained at baseline, immediately and 1, 3, 6, and 12 months after S-PVI to analyze the heart rate variability. Fifty-one patients were free from symptomatic PAF (Group A) and 26 had late PAF recurrences (Group B) at 12-month follow-up. Immediately after S-PVI, the root mean square of the successive differences (rMSSD) and high-frequency (HF) power, which reflected parasympathetic nervous activity, were significantly lower in Group A than in Group B (rMSSD: 33.6+/-26.0 vs 60.6+/-23.2 ms, P<0.05; ln HF: 8.73+/-0.84 vs 9.31+/-0.95 ms2, P<0.05). There were no significant differences in the average heart rate or ratio of the low-frequency to HF powers between the 2 groups. By multivariate analysis, only the HF immediately after S-PVI was an independent predictor of PAF recurrence (hazard ratio 1.707, 95% confidence interval 1.057-2.756, P<0.05). CONCLUSIONS: Vagal modification after S-PVI could also help prevent late recurrence of PAF.


Asunto(s)
Fibrilación Atrial/prevención & control , Ablación por Catéter , Venas Pulmonares , Nervio Vago , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Factores de Tiempo
20.
J Am Coll Cardiol ; 52(2): 139-47, 2008 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-18598894

RESUMEN

OBJECTIVES: This study investigated the prevalence and electrocardiographic and electrophysiologic characteristics of aortic root ventricular arrhythmias (VAs). BACKGROUND: Idiopathic VAs originating from the ostium of the left ventricle may be ablated at the base of the aortic cusps. METHODS: We studied 265 patients with idiopathic VAs with an inferior QRS-axis morphology. RESULTS: The successful ablation site was within (or below) the aortic cusps in 44 patients (16.6%). The site of the origin was the left coronary cusp (LCC) in 24 (54.5%), the right coronary cusp (RCC) in 14 (31.8%), the noncoronary cusp (NCC) in 1 (2.3%), and at the junction between the LCC and RCC (L-RCC) in 5 (11.4%) cases. The maximum amplitude of the R-wave in the inferior leads was significantly greater with an LCC than with an RCC origin (p < 0.05). The ratio of the R-wave amplitude in leads II and III was significantly greater with an LCC than with an RCC origin (p < 0.01) and was significantly smaller in the NCC than in the other sites (p < 0.0001). The ventricular deflection in the His bundle electrogram was significantly later relative to the surface QRS with an LCC or L-RCC origin than with an RCC or NCC origin (p < 0.0001). The ratio of the atrial-to-ventricular deflection amplitude was significantly greater in the NCC than in the other sites (p < 0.0001). No other factors predicted the site of origin. CONCLUSIONS: Idiopathic VAs are more common in the LCC than in the RCC and rarely arise from the NCC. The electrocardiogram is useful for differentiating the site of origin.


Asunto(s)
Enfermedades de la Aorta/fisiopatología , Arritmias Cardíacas/fisiopatología , Ablación por Catéter , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aorta/patología , Enfermedades de la Aorta/patología , Enfermedades de la Aorta/terapia , Arritmias Cardíacas/patología , Arritmias Cardíacas/terapia , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS