RESUMEN
BACKGROUND: Previous studies have demonstrated the safety of pulmonary endarterectomy (PEA) across body mass index (BMI) strata. However, long-term survival and patient-reported outcome measures by BMI strata remain unknown. We examined the impact of preoperative BMI on long-term survival, QOL, and functional outcomes for patients undergoing PEA for chronic thromboembolic pulmonary hypertension (CTEPH). METHODS: Retrospective review of 2,004 patients from the UK National Cohort between 2007 and 2021 undergoing PEA for CTEPH (mean pulmonary artery pressure >20 mm Hg and pulmonary vascular resistance >160 dynes). Patients were stratified into BMI<20, 20 to 29, 30 to 39, 40 to 49, and 50+. All-cause mortality was the primary outcome measure. Secondary outcome measures were 3- to 6-month postoperative hemodynamics, 6-minute walk distance (6MWD), New York Heart Association (NYHA) class, and Cambridge Pulmonary Hypertension Outcome Review (CAMPHOR) scores. RESULTS: Hemodynamics and 6MWD at 3 to 6 months were similar across BMI strata. Patients with BMI 50+ reported the highest incidence of postoperative NYHA III/IV limitation (53.3%, p < 0.001) and the highest residual symptom burden by CAMPHOR (p < 0.001). Five-year survival was lowest in patients with BMI 50+ (70.2%) and BMI<20 (73.4%), while highest in BMI 30 to 39 (88.2%, p = 0.008). Ten-year Kaplan-Meier estimates predicted the lowest survival in BMI 50+ and BMI<20. CONCLUSIONS: PEA remains safe and effective for all patients regardless of BMI. Despite similar hemodynamic outcomes, patients with BMI 50+ are at the greatest risk of long-term all-cause mortality, and patients with BMI 50+ experience residual symptomatic limitation.
RESUMEN
OBJECTIVES: This study aims to explore characteristics and clinical outcomes of patients with congenital heart disease (CHD) in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). METHODS: This is a retrospective study of EUROMACS participants receiving MCS as bridge-to-transplant, possible bridge-to-transplant, or rescue therapy/bridge-to-recovery from 2011 to 2023 (n = 5340). Adult and paediatric cohorts were analysed separately. The primary outcome was mortality on MCS; secondary outcomes included recovery, transplant and complications including bleeding, cerebrovascular events, and sepsis. RESULTS: Among adult patients, mortality at 1-year was 33.3% among the CHD cohort vs 22.1% in the non-CHD cohort. Adult CHD patients had higher hazards of mortality within the first year after MCS implantation [hazard ratios 1.98, 95% confidence interval (CI) 1.35-2.91, P < 0.001] and bleeding events (subdistribution hazard ratios 2.10, 95% CI 1.40-3.16, P < 0.001) compared with non-CHD patients. Both associations remained significant after accounting for multiple mediators. Among paediatric patients, mortality at 1 year was 22.1% in the CHD cohort vs 17.3% in the non-CHD cohort (hazard ratios 1.39, 95% CI 0.83-2.32, P = 0.213). CONCLUSIONS: Adult and paediatric patients with CHD on MCS have higher adverse event risk compared with non-CHD MCS patients, though children did not have greater risk of mortality. As the number of CHD patients requiring advanced heart failure management continues to grow, these findings can enhance informed decision-making. CLINICAL TRIAL REGISTRATION NUMBER: Registry name: EUROMACS.
Asunto(s)
Cardiopatías Congénitas , Corazón Auxiliar , Sistema de Registros , Humanos , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Adulto , Europa (Continente)/epidemiología , Niño , Corazón Auxiliar/estadística & datos numéricos , Corazón Auxiliar/efectos adversos , Adolescente , Preescolar , Lactante , Trasplante de Corazón/estadística & datos numéricos , Adulto Joven , Persona de Mediana EdadRESUMEN
An implantable left ventricular assist device (LVAD) is indicated as a bridge to transplantation or recovery in the United Kingdom (UK). The mechanism of action of the LVAD results in a unique state of haemodynamic stability with diminished arterial pulsatility. The clinical assessment of an LVAD recipient can be challenging because non-invasive blood pressure, pulse and oxygen saturation measurements may be hard to obtain. As a result of this unusual situation and complex interplay between the device and the native circulation, resuscitation of LVAD recipients requires bespoke guidelines. Through collaboration with key UK stakeholders, we assessed the current evidence base and developed guidelines for the recognition of clinical deterioration, inadequate circulation and time-critical interventions. Such guidelines, intended for use in transplant centres, are designed to be deployed by those providing immediate care of LVAD patients under conditions of precipitous clinical deterioration. In summary, the Joint British Societies and Transplant Centres LVAD Working Group present the UK guideline on management of emergencies in implantable LVAD recipients for use in advanced heart failure centres. These recommendations have been made with a UK resuscitation focus but are widely applicable to professionals regularly managing patients with implantable LVADs.
Asunto(s)
Deterioro Clínico , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Urgencias Médicas , Insuficiencia Cardíaca/terapiaRESUMEN
BACKGROUND: Pulmonary endarterectomy (PEA) is the guideline-recommended treatment for patients with chronic thromboembolic pulmonary hypertension (CTEPH). However, some patients develop severe cardiopulmonary compromise before surgery, intraoperatively, or early postoperatively. This may result from advanced CTEPH, reperfusion pulmonary edema, massive endobronchial bleeding, or right ventricular (RV) failure secondary to residual pulmonary hypertension. Conventional cardiorespiratory support is ineffective when these complications are severe. Since 2005, we used extracorporeal membrane oxygenation (ECMO) as a rescue therapy for this group. We review our experience with ECMO support in these patients. METHODS: This study was a retrospective analysis of patients who received perioperative ECMO for PEA from a single national center from August 2005 to July 2022. Data were prospectively collected. RESULTS: One hundred and ten patients (4.7%) had extreme cardiorespiratory compromise requiring perioperative ECMO. Nine were established on ECMO before PEA. Of those who received ECMO postoperatively, 39 were for refractory reperfusion lung injury, 20 for RV failure, 31 for endobronchial bleeding, and the remaining 11 were for "other" reasons, such as cardiopulmonary resuscitation following late tamponade and aspiration pneumonitis. Sixty-two (56.4%) were successfully weaned from ECMO. Fifty-seven patients left the hospital alive, giving a salvage rate of 51.8%. Distal disease (Jamieson Type III) and significant residual pulmonary hypertension were also predictors of mortality on ECMO support. Overall, 5- and 10-year survival in patients who were discharged alive following ECMO support was 73.9% (SE: 6.1%) and 58.2% (SE: 9.5%), respectively. CONCLUSIONS: Perioperative ECMO support has an appropriate role as rescue therapy for this group. Over 50% survived to hospital discharge. These patients had satisfactory longer-term survival.
Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Hipertensión Pulmonar , Daño por Reperfusión , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Hipertensión Pulmonar/cirugía , Hipertensión Pulmonar/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Hemorragia/etiología , Insuficiencia Cardíaca/terapia , Endarterectomía/efectos adversos , Daño por Reperfusión/complicaciones , Reino Unido/epidemiologíaAsunto(s)
Hipertensión Pulmonar , Embolia Pulmonar , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Imagen por Resonancia Magnética , Circulación Pulmonar , Radiografía , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Enfermedad Crónica , Arteria Pulmonar/diagnóstico por imagenRESUMEN
Left ventricular assist device outflow graft obstruction is an uncommon but serious complication. The causes of left ventricular assist device outflow graft obstruction include thrombus, outflow graft kink or torsion and external compression. The HeartMate 3 left ventricular assist device was reported to have a low risk of thromboembolic events. However, the deposition of bio-debris between the semi-permeable left ventricular assist device outflow graft and the impermeable bend relief has been increasingly recognized as a cause of external compression. The potential treatment options include percutaneous insertion of a stent, surgical removal of the bio-debris, change of left ventricular assist device, and an urgent heart transplant. We report a case of left ventricular assist device outflow graft compression successfully treated by removal of the bio-debris via a subxiphoid approach.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Trombosis , Humanos , Corazón Auxiliar/efectos adversos , Ventrículos Cardíacos/cirugía , Stents/efectos adversos , Trombosis/etiología , Trombosis/cirugía , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugíaRESUMEN
Pulmonary endarterectomy (PEA) may not achieve full clearance of vascular obstructions in patients with more distal chronic thromboembolic pulmonary hypertension (CTEPH). Balloon pulmonary angioplasty (BPA) may be indicated to treat these residual vascular lesions. We compared whether patients post-PEA (PP) treated by BPA derived similar benefit to those who had inoperable CTEPH (IC), and assessed predictors of BPA response after surgery. We treated 109 patients with BPA-89 with IC and 20 PP. Serial right heart catheterization performed at baseline (immediately before BPA) and 3 months after completing BPA, compared pulmonary vascular resistance (PVR), mean pulmonary artery pressure (mPAP) as well as change in WHO functional class and 6-minute walk distance. We also assessed the impact of total thrombus tail length (TTTL) from photographed PEA surgical specimens and PP computed tomography pulmonary angiography (CTPA)-quantified residual disease burden on BPA response. PP and IC groups did not differ significantly in terms of demographics, baseline hemodynamics or procedural characteristics. However, IC derived greater hemodynamic benefit from BPA: ΔPVR (-27.9 ± 20.2% vs. -13.9 ± 23.9%, p < 0.05) and ΔmPAP (-17.1 ± 14.4% vs. -8.5 ± 18.0%, p < 0.05). There was a negative correlation between pre-BPA PVR and TTTL (r = -0.47, p < 0.05) which persisted post-BPA. PVR, mPAP, WHO FC and 6MWD were not improved significantly post-BPA in PP patients. BPA response was not related to TTTL terciles or CTPA-quantified residual disease burden. Patients PP experienced inferior response to BPA, despite similar baseline and procedural characteristics to IC. BPA does not abolish the relationship between TTTL and postsurgical PVR in PP patients, suggesting that BPA is less effective in treating residual PH after surgery in an experienced surgical center.
RESUMEN
Experience in donation after circulatory-determined death (DCD) heart transplantation (HTx) is expanding. There is limited information on the functional outcomes of DCD HTx recipients. We sought to evaluate functional outcomes in our cohort of DCD recipients. We performed a single-center, retrospective, observational cohort study comparing outcomes in consecutive DCD and donation after brain death (DBD) HTx recipients between 2015 and 2019. Primary outcome was allograft function by echocardiography at 12 and 24 months. Secondary outcomes included incidence of cardiac allograft vasculopathy, treated rejection, renal function, and survival. Seventy-seven DCD and 153 DBD recipients were included. There was no difference in left ventricular ejection fraction at 12 months (59% vs 59%, P = .57) and 24 months (58% vs 58%, P = .87). There was no significant difference in right ventricular function at 12 and 24 months. Unadjusted survival between DCD and DBD recipients at 5 years (85.7% DCD and 81% DBD recipients; P = .45) was similar. There were no significant differences in incidence of cardiac allograft vasculopathy (odds ratio 1.59, P = .21, 95% confidence interval 0.77-3.3) or treated rejection (odds ratio 0.60, P = .12, 95% confidence interval 0.32-1.15) between DBD and DCD recipients. Post-transplant renal function was similar at 1 and 2 years. In conclusion, cardiac allografts from DCD donors perform similarly to a contemporary population of DBD allografts in the medium term.
Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Humanos , Supervivencia de Injerto , Estudios Retrospectivos , Incidencia , Volumen Sistólico , Función Ventricular Izquierda , Donantes de Tejidos , Muerte Encefálica , Trasplante de Corazón/efectos adversos , Aloinjertos , MuerteRESUMEN
INTRODUCTION: A new UK Lung Allocation Scheme (UKLAS) was introduced in 2017, replacing the previous geographic allocation system. Patients are prioritised according to predefined clinical criteria into a three-tier system: the super-urgent lung allocation scheme (SULAS), the urgent lung allocation scheme (ULAS) and the non-urgent lung allocation scheme (NULAS). This study assessed the early impact of this scheme on waiting-list and post-transplant outcomes. METHODS: A cohort study of adult lung transplant registrations between March 2015 and November 2016 (era-1) and between May 2017 and January 2019 (era-2). Outcomes from registration were compared between eras and stratified by urgency tier and diagnostic group. RESULTS: During era-1, 461 patients were registered. In era-2, 471 patients were registered (19 (4.0%) SULAS, 82 (17.4%) ULAS and 370 (78.6%) NULAS). SULAS patients were younger (median age 35 vs 50 and 55 for urgent and non-urgent, respectively, p=0.0015) and predominantly suffered from cystic fibrosis (53%) or pulmonary fibrosis (37%). Between eras 1 and 2, the odds of transplantation within 6 months of registration were increased (OR=1.41, 95% CI 1.07 to 1.85, p=0.0142) despite only a 5% increase in transplant activity. Median time-to-transplantation during era-1 was 427 days compared with waiting times in era-2 of 8 days for SULAS, 15 days for ULAS and 585 days for NULAS patients. Waiting-list mortality (15% era-1 vs 13% era-2; p=0.5441) and post-transplant survival at 1 year (81.3% era-1 vs 83.3% era-2; p=0.6065) were similar between eras. CONCLUSION: The UKLAS scheme prioritises the critically ill and improves transplantation odds. The true impact on waiting-list mortality and post-transplant survival requires further follow-up.
Asunto(s)
Fibrosis Quística , Trasplante de Pulmón , Adulto , Humanos , Estudios de Cohortes , Pulmón , Reino Unido/epidemiología , Estudios RetrospectivosRESUMEN
BACKGROUND: The United Kingdom (UK) was one of the first countries to pioneer heart transplantation from donation after circulatory death (DCD) donors. To facilitate equity of access to DCD hearts by all UK heart transplant centers and expand the retrieval zone nationwide, a Joint Innovation Fund (JIF) pilot was provided by NHS Blood and Transplant (NHSBT) and NHS England (NHSE). The activity and outcomes of this national DCD heart pilot program are reported. METHODS: This is a national multi-center, retrospective cohort study examining early outcomes of DCD heart transplants performed across 7 heart transplant centers, adult and pediatric, throughout the UK. Hearts were retrieved using the direct procurement and perfusion (DPP) technique by 3 specialist retrieval teams trained in ex-situ normothermic machine perfusion. Outcomes were compared against DCD heart transplants before the national pilot era and against contemporaneous donation after brain death (DBD) heart transplants, and analyzed using Kaplan-Meier analysis, chi-square test, and Wilcoxon's rank-sum. RESULTS: From September 7, 2020 to February 28, 2022, 215 potential DCD hearts were offered of which 98 (46%) were accepted and attended. There were 77 potential donors (36%) which proceeded to death within 2 hours, with 57 (27%) donor hearts successfully retrieved and perfused ex situ and 50 (23%) DCD hearts going on to be transplanted. During this same period, 179 DBD hearts were transplanted. Overall, there was no difference in the 30-day survival rate between DCD and DBD (94% vs 93%) or 90 day survival (90% vs 90%) respectively. There was a higher rate of ECMO use post-DCD heart transplants compared to DBD (40% vs 16%, p = 0.0006), and DCD hearts in the pre pilot era, (17%, p = 0.002). There was no difference in length of ICU stay (9 DCD vs 8 days DBD, p = 0.13) nor hospital stay (28 DCD vs 27 DBD days, p = 0.46). CONCLUSION: During this pilot study, 3 specialist retrieval teams were able to retrieve DCD hearts nationally for all 7 UK heart transplant centers. DCD donors increased overall heart transplantation in the UK by 28% with equivalent early posttransplant survival compared with DBD donors.
Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Adulto , Humanos , Niño , Donantes de Tejidos , Estudios Retrospectivos , Proyectos Piloto , Muerte Encefálica , Reino Unido/epidemiología , Supervivencia de Injerto , MuerteRESUMEN
Chronic thromboembolic pulmonary hypertension occurs in a proportion of patients with prior acute pulmonary embolism and is characterised by breathlessness, persistently raised pulmonary pressures and right heart failure. Surgical pulmonary endarterectomy (PEA) offers significant prognostic and symptomatic benefits for patients with proximal disease distribution. For those with inoperable disease, management options include balloon pulmonary angioplasty (BPA) and medical therapy. Current clinical practice relies on the evaluation of pulmonary haemodynamics to assess disease severity, timing of and response to treatment. However, pulmonary haemodynamics correlate poorly with patient symptoms, which are influenced by right ventricular tolerance of the increased afterload. How best to manage symptomatic patients with chronic thromboembolic pulmonary disease (CTEPD) in the absence of pulmonary hypertension is not resolved.Right ventricular-pulmonary artery coupling (RV-PAC) describes the energy transfer within the whole cardiopulmonary unit. Thus, it can identify the earliest signs of decompensation even before pulmonary hypertension is overt. Invasive measurement of coupling using pressure volume loop technology is well established in research settings. The development of efficient and less invasive measurement methods has revived interest in coupling as a viable clinical tool. Significant improvement in RV-PAC has been demonstrated after both PEA and BPA. Further studies are required to understand its clinical utility and prognostic value, in particular, its potential to guide management in patients with CTEPD. Finally, given the reported differences in coupling between sexes in pulmonary arterial hypertension, further work is required to understand the applicability of proposed thresholds for decoupling in therapeutic decision making.
Asunto(s)
Angioplastia de Balón , Hipertensión Pulmonar , Embolia Pulmonar , Humanos , Arteria Pulmonar/cirugía , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/terapia , Resultado del Tratamiento , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Corazón , Enfermedad Crónica , Función Ventricular Derecha/fisiología , EndarterectomíaRESUMEN
BACKGROUND: Heart transplantation (HTx) after donation after circulatory death (DCD) is an expanding practice but is associated with increased warm ischemic time. The impact of DCD HTx on cardiac mechanics and myocardial fibrosis has not been reported. We aimed to compare cardiac mechanics and myocardial fibrosis using cardiovascular magnetic resonance (CMR) imaging in donation after brain death (DBD) and DCD HTx recipients and healthy controls. METHODS AND RESULTS: Consecutive HTx recipients between March 2015 and March 2021 who underwent routine surveillance CMR imaging were included. Cardiac mechanics were assessed using CMR feature tracking to compute global longitudinal strain, global circumferential strain, and right ventricular free-wall longitudinal myocardial strain. Fibrosis was assessed using late gadolinium enhancement imaging and estimation of extracellular volume. There were 82 (DBD nâ¯=â¯42, DCD nâ¯=â¯40) HTx recipients (aged 53 years, interquartile range 41-59 years, 24% female) who underwent CMR imaging at median of 9 months (interquartile range 6-14 months) after transplantation. HTx recipients had increased extracellular volume (29.7 ± 3.6%) compared with normal ranges (25.9%, interquartile range 25.4-26.5). Myocardial strain was impaired after transplantation compared with controls (global longitudinal strain -12.6 ± 3.1% vs -17.2 ± 1.8%, P < .0001; global circumferential strain -16.9 ± 3.1% vs -19.2 ± 2.0%, Pâ¯=â¯.002; right ventricular free-wall longitudinal strain -15.7 ± 4.5% vs -21.6 ± 4.7%, P < .0001). There were no differences in fibrosis burden (extracellular volume 30.6 ± 4.4% vs 29.2 ± 3.2%; Pâ¯=â¯.39) or cardiac mechanics (global longitudinal strain -13.1 ± 3.0% vs -12.1 ± 3.1%, Pâ¯=â¯.14; global circumferential strain -17.3 ± 2.9% vs -16.6 ± 3.1%, Pâ¯=â¯.27; right ventricular free-wall longitudinal strain -15.9 ± 4.9% vs -15.5 ± 4.1%, Pâ¯=â¯.71) between DCD and DBD HTx. CONCLUSIONS: HTx recipients have impaired cardiac mechanics compared with controls, with increased myocardial fibrosis. There were no differences in early CMR imaging characteristics between DBD and DCD heart transplants, providing further evidence that DCD and DBD HTx outcomes are comparable.
Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Trasplante de Corazón , Humanos , Femenino , Masculino , Medios de Contraste , Gadolinio , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Fibrosis , Estudios Retrospectivos , Donantes de TejidosRESUMEN
The proposed donor heart selection guidelines provide evidence-based and expert-consensus recommendations for the selection of donor hearts following brain death. These recommendations were compiled by an international panel of experts based on an extensive literature review.
Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Humanos , Selección de Donante , Muerte Encefálica , ConsensoRESUMEN
INTRODUCTION: The Carpentier-Edwards PERIMOUNT Magna Ease valve is a third-generation bioprosthesis for aortic valve replacement (AVR). This is a postapproval study reporting on its 8-year outcomes. METHODS: Adults undergoing AVR with the Magna Ease valve between October 2007 and December 2012 were enrolled for this prospective, nonrandomized, single-arm, and multicenter study. Assessments occurred preoperatively, at hospital discharge, 6 months, 1 year, and annually thereafter for up to 8 years. Outcomes included safety endpoints, hemodynamic performance, and New York Heart Association (NYHA) functional class. RESULTS: Of the 258 study patients, 67.5% were in NYHA Class I or II, and 32.5% were in NYHA Class III or IV at baseline. Concomitant procedures were performed in 44.2%. Total follow-up was 1597.6 patient-years, and median follow-up was 7 years (interquartile range: 5.5-8.0 years). Eight years following AVR, the functional class remained improved from baseline with 93.9% in NYHA Class I/II and 6.1% in NYHA Class III; 38 deaths had occurred, 8 of which were valve related; freedom from all-cause mortality was 80.7% (95% confidence intervals: 74.9, 86.4); freedom from valve-related mortality was 95.8% (92.8, 98.8); freedom from reintervention, explant, major bleeding events, and structural valve deterioration was 89.8% (85.1, 94.6), 94.8% (91.7, 97.9), 85.1% (80.0, 90.1), and 90.1% (84.7, 95.4), respectively; effective orifice area was 1.5 ± 0.5 cm2 , the mean gradient was 14.8 ± 8.3 mmHg, and 88.6% of patients had no or trivial aortic regurgitation. CONCLUSIONS: This study demonstrated satisfactory safety and sustained hemodynamic and functional improvements at 8 years following AVR with the Magna Ease valve.
Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Humanos , Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Estudios de Seguimiento , Estudios RetrospectivosRESUMEN
BACKGROUND: Ex-situ heart perfusion (ESHP) is commonly used for the reanimation and preservation of hearts following donation after circulatory determined death (DCD). The only commercially available existing ESHP device promotes perfusate lactate levels for assessment of heart viability. The reliability of this marker is yet to be confirmed for DCD heart transplantation. METHODS: This is a single center, retrospective study examining DCD heart transplants from March 1, 2015 to June 30, 2020. Recipients were divided into 2 groups dependent upon their requirement for or absence of mechanical circulatory support post-transplant. Lactate profiles obtained during ESHP were analyzed. Hearts were procured using the direct procurement and perfusion (DPP) method. RESULTS: Fifty-one DCD heart transplant recipients were studied, of which 20 (39%) were dependent on mechanical circulatory support (MCS) following transplantation, (2% Ventricular Assist Device (VAD), 16% Extra Corporeal Membrane Oxygenation (ECMO) and 21% Intra-aortic balloon pumps (IABP). There was no difference in arterial lactate profiles on ESHP at any time point for those dependent upon MCS support (MCS) and those that were not (no MCS) post-transplant. After 3 hours of ESHP, the arterial lactate was >5mmol/L in 80% upon MCS vs 62% no MCS, p = .30. There was also no difference in ESHP rising arterial lactate concentrations, (15% MCS vs 13% non MCS, p = 1.00). CONCLUSION: For DCD hearts transplants retrieved using the DPP technique, lactate profiles do not seem to be a reliable predictor of mechanical circulatory support requirement post-transplant.
Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Trasplante de Corazón/métodos , Humanos , Ácido Láctico , Perfusión/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Donantes de TejidosRESUMEN
Predicted heart mass (PHM) equations may be used in donor-recipient size matching in heart transplantation. We compared PHM and actual heart mass in 25 consecutive DBD heart transplants. There was a moderate positive correlation between actual heart mass and PHM. There was a similar moderate correlation between actual heart mass and donor weight or donor body surface area but not donor height. PHM was lower than actual heart mass for all donor hearts. Bland-Altman analysis showed a systematic bias between PHM and actual heart mass, with a mean difference of 190.9 ± 66.4 g. The utility of PHM equations is likely to be part of a multi-parametric assessment of the relative differences between donor and recipient, so the absolute difference is likely to be unimportant.
Asunto(s)
Trasplante de Corazón , Peso Corporal , Humanos , Estudios Retrospectivos , Donantes de TejidosRESUMEN
BACKGROUND: Thoracoabdominal normothermic regional perfusion (NRP) is a new method for in situ reperfusion and reanimation of potential donor organs in donation after circulatory death by reperfusion of the thoracic and abdominal organs with oxygenated blood. We investigated effects of high oxygenation (HOX) versus low oxygenation (LOX) during NRP on donor heart function in a porcine model. METHODS: Pigs (80 kg) underwent a 15-min anoxic cardiac arrest followed by cardiac reanimation on NRP using a heart-lung bypass machine with subsequent assessment 180 min post-NRP. The animals were randomized to HOX (FiO2 1.0) or LOX (FiO2 0.21 increased to 0.40 during NRP). Hemodynamic data were obtained by invasive blood pressure and biventricular pressure-volume measurements. Blood gases, biomarkers of inflammation, and oxidative stress were measured. RESULTS: Eight of 9 animals in the HOX group and 7 of 10 in the LOX group were successfully weaned from NRP. Right ventricular end-systole elastance was significantly improved in the HOX group compared with the LOX group, whereas left ventricular end-systole elastance was preserved at baseline levels. Post-NRP cardiac output, mean arterial, central venous, and pulmonary capillary wedge pressure were all comparable to baseline. Creatinine kinase-MB increased more in the LOX group than the HOX group, whereas proinflammatory cytokines increased more in the HOX group than the LOX group. No difference was found in oxidative stress between groups. CONCLUSIONS: All hearts weaned from NRP showed acceptable hemodynamic function for transplantation. Hearts exposed to LOX showed more myocardial damage and showed poorer contractile performance than hearts reperfused with high oxygen.
Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Animales , Muerte , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/métodos , Humanos , Preservación de Órganos/métodos , Oxígeno , Perfusión/métodos , PorcinosRESUMEN
Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of -2.0% (1-sided 97.5% CI, -∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
Background: Pulmonary thromboendarterectomy (PTE) was first introduced to the UK 25 years ago, and the UK national service is provided by a single hospital. The aim of this work is to summarize our experience and review activity and outcomes by era at a high-volume PTE center. During this period the understanding of chronic thromboembolic pulmonary hypertension (CTEPH) increased and drug treatments and balloon angioplasty were developed. We also review our contribution to the better understanding of this surgery and CTEPH. Methods: We retrospectively reviewed all patients undergoing PTE for CTEPH at our center between Jan 1997 and Sept 2019, dividing them into four equal cohorts. Pre-operative characteristics and post-operative outcomes are described by era. A MEDLINE search was performed and original scientific clinical publications from this unit were reviewed. Their contemporary relevance and influence to the evolution of the clinical service are discussed. Results: Over this 23-year period from the commencement of our program, 2,116 consecutive PTE were performed. The mean patient age was 57.8 years (range, 11-89 years). The first 25% of our PTE were performed over 12 years whilst the most recent 25% were performed in less than three years. Over time, the average pre-operative mean pulmonary artery pressure has not changed significantly. The 30-day mortality by era quartile has progressively fallen from 12.3% to 1.9% most recently (P<0.001). Overall, one year survival exceeded 90%. 17 publications influenced our practice development during this period. Conclusions: There was a consistent increase in activity and significant improvement in outcomes between the first and last quartiles of activity studied.
RESUMEN
The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a signiï¬cantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices. (J Thorac Cardiovasc Surg 2022;-:1-8).