Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Egypt Heart J ; 76(1): 10, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38285096

RESUMEN

BACKGROUND: Diagnostic delay (DD) can be lethal when patients with type A acute aortic dissection (TAAAD). We report 3 cases of DD associated with TAAAD. CASE PRESENTATION: Case 1 is a female in her sixties presenting with severe back pain. A CT scan was taken, and TAAAD with a thrombosed false lumen was suspected by the radiology technician. He did not successfully transfer his concern to the physicians and the patient was sent home. The next day, she was transferred to another hospital with a recurrence of the symptom, and the diagnosis of TAAAD was made with a CT scan there. Case 2 was an 87-year-old female who was transferred to our hospital because of a loss of consciousness and bruises on the forehead. CT scan was taken and the displaced intimal flap in her aortic arch was overlooked by the part-time physician almost at the end of his shift. The diagnosis of TAAAD was made by the radiologist. Case 3 was the 44-year-old male who did not have health insurance and experienced severe back pain a few days before the visit to our clinic. On that day, he went to the nearby hospital's emergency room, and only pain medication was prescribed. A few days later, a CT scan was taken at our hospital to investigate the cause of pyuria and the diagnosis of TAAAD was made. CONCLUSION: DD may be common and multifactorial in our practice. Physicians need to take every step to improve diagnostic accuracy.

3.
J Cardiothorac Surg ; 17(1): 95, 2022 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-35505355

RESUMEN

BACKGROUND: The optimal treatment for aortic thrombus remains to be determined, but surgical treatment is indicated when there is a risk for thromboembolism. CASE PRESENTATION: A 47-year-old male presented with weakness in his left arm upon awakening. Contrast-enhanced computed tomography and transesophageal echocardiography revealed a mobile pedunculated object suggestive of a thrombus arising from the ascending aorta and extending to the left common carotid artery. It was removed under hypothermic circulatory arrest and direct cannulation of the left carotid artery to avoid carotid thromboembolism. Histopathological examination revealed that the object was a thrombus. The patient had an uneventful postoperative course and was discharged 9 days after surgery. CONCLUSION: When a thrombus in the aortic arch extends to the neck arteries, direct cannulation of the neck arteries with selective cerebral perfusion via cervical incision is a useful technique.


Asunto(s)
Tromboembolia , Trombosis , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/cirugía , Humanos , Masculino , Persona de Mediana Edad , Perfusión/métodos , Trombosis/diagnóstico por imagen , Trombosis/cirugía
4.
J Card Surg ; 36(12): 4618-4622, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34618983

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Coronary artery fistula (CAF) is a relatively rare cardiac anomaly. We investigated long-term outcomes following surgical repair of CAF in adults. METHODS: We retrospectively investigated 13 consecutive patients undergoing surgical repair of CAF in our institution between 2008 and 2019 (67.3 ± 10.4 years old, 38% male). CAF types were coronary artery-pulmonary artery fistula (77%), coronary artery-coronary sinus fistula (15%), and both (8%). CAFs originated from the left coronary artery (38%), right coronary artery (8%), and bilateral coronary arteries (38%). Pulmonary and systemic flow (Qp/Qs) was measured in seven patients (54%), with a mean value of 1.52. Seven patients underwent surgery for CAFs alone, and others simultaneously underwent surgery for comorbid cardiac diseases. RESULTS: All procedures were conducted under cardiopulmonary bypass. Surgical procedures were direct epicardial ligation of fistula (92%), direct closure of CAF through pulmonary artery incision (38%), direct closure of CAF through coronary sinus incision (8%), or patch closure of CAF through coronary artery incision (8%). Myocardial perfusion scintigraphy showed asymptomatic myocardial ischemia in the right coronary area after surgery in one patient. There were no deaths perioperatively or during follow-up (mean: 66.6 months). There were no coronary or other CAF-related events. CONCLUSIONS: Several anatomical variations in CAF were observed which coexist with cardiac disease. Long-term outcomes following surgical repair were satisfactory, and the concurrent intervention of CAFs during surgery for comorbid cardiac disease is useful to prevent future complications related CAFs in adults.


Asunto(s)
Fístula Arteriovenosa , Anomalías de los Vasos Coronarios , Cardiopatías Congénitas , Fístula Vascular , Adulto , Anciano , Angiografía Coronaria , Anomalías de los Vasos Coronarios/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
5.
Interact Cardiovasc Thorac Surg ; 33(3): 348-353, 2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-33961031

RESUMEN

OBJECTIVES: To determine the incidence of bioprosthetic structural valve deterioration in dialysis patients undergoing aortic valve replacement compared to that in patients without dialysis. METHODS: This single-centre retrospective observational study included 1159 patients who underwent aortic valve replacement using bioprosthetic valves for aortic stenosis and/or regurgitation at our institution between 2007 and 2017 [patients with dialysis (group D, n = 134, 12%) or without dialysis (group N, n = 1025, 88%)]. To adjust for potential differences between groups in terms of initial preoperative characteristics or selection bias, a propensity score analysis was conducted. The final sample that was used in the comparison included 258 patients, as follows: 129 patients with dialysis (group D) and 129 patients without dialysis (group N). The cumulative incidences of all-cause death, cardiac death and moderate or severe structural valve deterioration were estimated using the Kaplan-Meier method. RESULTS: Operative mortality was significantly higher in group D than group N (9% vs 0%, P = 0.001). Kaplan-Meier analysis revealed that in group D, the incidence was significantly higher for all-cause death (P < 0.001, 50% vs 18% at 5 years), cardiac death (P = 0.001, 18% vs 5% at 5 years) and moderate or severe structural valve deterioration (P < 0.001, 29% vs 5% at 5 years) compared with group N. CONCLUSIONS: The incidence of structural valve deterioration in dialysis patients undergoing aortic valve replacement was higher than that in patients without dialysis. Bioprosthetic valves should be carefully selected in dialysis patients undergoing aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Diálisis Renal , Estudios Retrospectivos , Resultado del Tratamiento
6.
Circ J ; 85(6): 850-856, 2021 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-33342917

RESUMEN

BACKGROUND: The effect of multiple prior percutaneous coronary interventions (PCIs) before subsequent coronary artery bypass grafting (CABG) on long-term outcomes has not been well elucidated.Methods and Results:Between 2007 and 2016, 1,154 patients undergoing primary isolated CABG in our institution had no prior PCI (Group N), 225 had a single prior PCI (Group S), and 272 had multiple prior PCIs (Group M). Cumulative incidences of all-cause death, cardiac death and myocardial infarction (MI) at 10 years post-CABG were highest in Group M. After adjusting for confounders, the risk of all-cause death was higher in Group M than in Group N (hazard ratio [HR] 1.45; 95% confidence interval [CI], 1.10-1.91; P<0.01). Between Groups N and S, however, the risk of all-cause death was not different. The risks of cardiac death and MI were likewise higher in Group M than in Group N (HR, 2.39; 95% CI, 1.55-3.71; P<0.01 and HR, 3.65; 95% CI, 1.16-11.5; P=0.03, respectively), but not different between Groups N and S. The risk of repeat revascularization was not different among any of the groups. CONCLUSIONS: Multiple prior PCIs was associated with higher risks of long-term death and cardiovascular events. The incidence of repeat revascularization after CABG was low regardless of the history of single/multiple PCIs.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Humanos , Infarto del Miocardio , Factores de Riesgo , Accidente Cerebrovascular , Factores de Tiempo , Resultado del Tratamiento
7.
J Vasc Surg ; 68(4): 1209-1215, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29242072

RESUMEN

OBJECTIVE: Recent studies demonstrate that microRNAs show promising potential, including angiogenesis, in therapeutic intervention. MicroRNA-126 (miR-126) is reported to regulate angiogenesis by blocking Sprouty-related EVH1 domain-containing protein 1 (SPRED1), an endogenous inhibitor of vascular endothelial cell growth factor. In this study, we investigated the angiogenic effects of the sustained release of miR-126 loaded with poly lactic-co-glycolic acid (PLGA) nanoparticles (NPs) in a murine hindlimb ischemia model. METHODS: We induced mice hindlimb ischemia through femoral artery excision. We randomly assigned the mice to two groups and performed an intramuscular injection of miR-126-loaded PLGA NPs (miR-126) or scrambled miR-loaded PLGA NPs (control) shortly after induction of ischemia. RESULTS: The miR-126 expression levels in the ischemic limb at 3 days after treatment were significantly higher in mice treated with miR-126-loaded PLGA NPs than in those with scrambled miR, indicating the fair efficiency of local miR transduction (control vs miR-126: 0.33 ± 0.12 vs 0.74 ± 0.42; P < .05; n = 6). Laser Doppler perfusion imaging revealed that limb blood flow in mice treated with miR-126-loaded PLGA NPs was significantly higher at 14 days after treatment (sham vs control vs miR-126: 0.62 ± 0.09 vs 0.58 ± 0.05 vs 0.72 ± 0.07; P < .001; n = 12). Immunohistochemical analysis indicated that CD31-positive cell density and α-smooth muscle actin-positive vessel density were significantly higher in miR-126-treated mice (control vs miR-126: 0.33 ± 0.12 vs 0.74 ± 0.42; P < .05; n = 6). SPRED1 messenger RNA expression levels were significantly lower in miR-126-treated mice (control vs miR-126: 1.00 ± 0.05 vs 0.81 ± 0.07; P < .05; n = 6). Western blotting indicated that protein levels of pERK/ERK mediated by SPRED1 were significantly higher in miR-126-treated mice (control vs miR-126: 0.29 ± 0.10 vs 0.54 ± 0.21; P < .05; n = 6). CONCLUSIONS: This study suggests that sustained release of miR-126-loaded PLGA NPs might be an effective method in therapeutic angiogenesis for hindlimb ischemia.


Asunto(s)
Isquemia/terapia , MicroARNs/administración & dosificación , Músculo Esquelético/irrigación sanguínea , Nanopartículas , Neovascularización Fisiológica , Copolímero de Ácido Poliláctico-Ácido Poliglicólico/química , Actinas/metabolismo , Proteínas Adaptadoras Transductoras de Señales , Animales , Velocidad del Flujo Sanguíneo , Modelos Animales de Enfermedad , Quinasas MAP Reguladas por Señal Extracelular/metabolismo , Miembro Posterior , Inyecciones Intramusculares , Isquemia/genética , Isquemia/metabolismo , Isquemia/fisiopatología , Masculino , Ratones Endogámicos C57BL , MicroARNs/genética , MicroARNs/metabolismo , Fosforilación , Molécula-1 de Adhesión Celular Endotelial de Plaqueta/metabolismo , Flujo Sanguíneo Regional , Proteínas Represoras/genética , Proteínas Represoras/metabolismo , Transducción de Señal , Factores de Tiempo
9.
J Cardiol Cases ; 10(6): 213-215, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30534246

RESUMEN

We present two cases of aortic valve replacement (AVR) in patients with protruding coronary artery stents from the coronary ostia. In the first case, an 87-year-old female was referred for AVR due to severe aortic stenosis (AS). During the operation, we found stents protruding from the left and the right coronary ostia into the aortic root. We performed AVR with a mechanical valve and coronary artery bypass grafting with the saphenous vein to the left anterior descending artery. In the second case, a 77-year-old female was referred for AVR due to severe AS with a history of healed infective endocarditis. During surgery on the second patient, we found a stent protruding 7 mm from the left coronary ostium into the aortic root. The edge of the stent was trimmed, and AVR with a mechanical valve was performed. In both patients, we decided to use a mechanical prosthesis instead of a bioprosthesis because of the risk of leaflet injury. Herein, we discuss some issues regarding patients with AS requiring AVR with prior history of coronary stenting in the coronary ostia. .

10.
Kyobu Geka ; 66(9): 837-40, 2013 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-23917239

RESUMEN

We encountered a case of total anomalous pulmonary venous connection with a drainage vein following an unusual course. The drainage vein, after emerging from the right lung, crossed the midline and drained into the innominate vein. Along the course of this vein, severe stenosis was present in the region wedged between the aortic arch and pulmonary artery, leading to severe pulmonary congestion. The common pulmonary vein was well developed. There was no other intracardiac malformation except atrial septal defect. No heterotaxy syndrome associated. Because echocardiography was unable to provide a complete picture of the pulmonary veins and drainage veins, multidetector-row computed tomography was performed to ascertain the anatomy. Emergency surgical intervention was carried out and anastomosis of the common pulmonary vein to the left atrium was performed. The postoperative course was favorable.


Asunto(s)
Anomalías Múltiples , Venas Braquiocefálicas/anomalías , Venas Pulmonares/anomalías , Síndrome de Cimitarra , Anastomosis Quirúrgica , Procedimientos Quirúrgicos Cardiovasculares , Urgencias Médicas , Humanos , Recién Nacido , Masculino , Tomografía Computarizada Multidetector , Venas Pulmonares/cirugía , Síndrome de Cimitarra/diagnóstico por imagen , Síndrome de Cimitarra/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...