J Interv Card Electrophysiol ; 67(1): 193-201, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37490133

RESUMEN

BACKGROUND: Confluent inferior pulmonary veins (CIPV) is a rare anatomical variant. There is few evidence in the literature regarding anatomic landmarks consideration to guide radiofrequency application in avoiding complications in the esophagus in CIPV cases. METHODS: Of 986 consecutive patients undergoing atrial fibrillation (AF) ablation from July 2020 to June 2022, seven (0.7%) had CIPV with a common trunk connecting to the LA diagnosed by 3-dimensional contrast-enhanced computed tomography. Using intracardiac echocardiography (ICE) performed from the left atrium (LA), we measured the posterior wall thickness (PWT) of the CIPV adjacent to the esophagus and compared the measurement with the LA posterior wall thickness (LAPWT) at the left inferior PV level of 25 controls without CIPV. For ablation in CIPV patients, each superior PV was individually isolated, and box isolation of CIPV without ablating the CIPV posterior wall was added (tri-circle ablation technique). RESULTS: The CIPV PWT was 0.7 ± 0.1 mm, while non-CIPV LAPWT was 2.0 ± 0.4 mm (P < 0.001). In the CIPV group, upper and lower portions of the CIPV were both apart from the esophagus (mean distances, 6.7 ± 3.4 mm and 7.9 ± 2.7 mm, respectively). Individual superior PV isolation and box CIPV isolation resulted in complete isolation of all PVs, with no complications. All CIPV patients except one remained AF recurrence-free for 376 ± 52 days. CONCLUSIONS: Although CIPV frequency is low, CIPV PWT is very thin and special care is needed during ablation. A "tri-circle" ablation strategy avoids ablating in the thinnest portion of the posterior wall. Further studies are warranted to assess the safety.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ecocardiografía/métodos , Ablación por Catéter/métodos , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 34(12): 2452-2460, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37787003

RESUMEN

INTRODUCTION: Although first-pass isolation (FPI) of the pulmonary vein (PV) has been suggested as a marker for PV isolation (PVI) durability, it has not been confirmed. Non-PV atrial fibrillation (AF) triggers were the main target in patients without PV reconnection in the second ablation procedure, but the outcome was unclear. We aimed to validate FPI as a marker of PVI durability and evaluate the outcome after the second procedure in patients without PV reconnection by comparing it to those with reconnection. METHODS: Among the 2087 patients undergoing the first ablation index-guided radiofrequency AF ablation, 309 with atrial tachyarrhythmias (ATs) recurrence and undergoing the second procedure were studied. Clinical characteristics and outcomes were compared between the patients without PV reconnection (PV non-reconnection group, n = 142) and with reconnection (PV reconnection group, n = 167). RESULTS: FPI in both PV sides in the first ablation procedure was significantly more frequent in the PV non-reconnection group (77.5%) than in the PV reconnection group (45.5%) (p < .001). Multivariate logistic regression analysis revealed that FPI (odds ratio, 3.71 [95% confidence interval, 2.23-6.19], p < .001) was the only predictor of PV non-reconnection. Radiofrequency applications for non-PV AF triggers were more frequently performed in the PV non-reconnection group (40.8% vs. 24.6%, respectively, p < .001). Kaplan-Meier analysis revealed that AT recurrence-free rate was significantly lower in the PV non-reconnection group (1-year recurrence-free rate, 62.7% vs. 75.4%, respectively; p = .01 by log-rank test). CONCLUSION: FPI was the only independent predictor of PV non-reconnection. Despite aggressive ablation for non-PV triggers, AT recurrence was more frequent in patients with PV non-reconnection.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
4.
Clin Cardiol ; 46(7): 794-800, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37199002

RESUMEN

BACKGROUND: Limited data on the efficacy and safety of atrial fibrillation (AF) ablation using an ablation index (AI) for octogenarians is available. We aimed to compare the efficacy and safety of AI-guided AF ablation between AF patients aged ≥80 years (Group 1) and <80 (Group 2). HYPOTHESIS: We hypothesized that AI-guided AF ablation could complete the procedure with comparable efficiency and safety in patients aged ≥80 years and <80. METHODS: We retrospectively reviewed 2087 AF patients undergoing their first AI-guided AF ablation in our hospital. We compared the atrial tachyarrhythmia (AT) recurrence and procedure-related complication rate between Group 1 (n = 193) and Group 2 (n = 1894). RESULTS: The mean age was 83.0 (interquartile range [IQR] 81.0, 84.0) years in Group 1 and 67.0 (IQR 60.0, 72.0) in Group 2. AF type was significantly different between the two groups: Of Group 1 patients, 120 (62.2%) had paroxysmal AF, 61 (31.6%) persistent AF, and 12 (6.2%) long-standing persistent AF, while of Group 2 patients, 1016 (53.6%) paroxysmal AF, 582 (30.7%) persistent AF, and 296 (15.6%) long-standing persistent AF (p = .001). Unadjusted AT recurrence-free survival curves showed similar AT recurrence-free survival between the two groups (p = .67 by log-rank test). After the adjustment for AF type, the survival curve was similar between them (hazard ratio, 1.24; 95% CI [0.92-1.65]; p = .15, Group 1 vs. Group 2). The rate of procedure-related complications was similar between the two groups (3.1% vs. 3.0%, respectively, p = .83). CONCLUSION: Catheter ablation guided by AI achieved similar AT recurrence and complication rates between elderly AF patients aged ≥80 years and patients <80 years.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Anciano de 80 o más Años , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios Retrospectivos , Octogenarios , Resultado del Tratamiento , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía
6.
J Interv Card Electrophysiol ; 63(3): 629-637, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34791606

RESUMEN

PURPOSE: Localization of the esophagus and the left atrium (LA) posterior wall thickness (LAPWT) should be taken into account when delivering radiofrequency energy. To validate the visualization of the esophagus and analyze LAPWT by ICE advanced into the LA in patients with atrial fibrillation (AF) undergoing ablation index (AI)-guided pulmonary vein (PV) isolation. METHODS: In 73 patients (mean age, 68 ± 12; paroxysmal AF in 45), a 3-dimensional (3D) esophagus image was created with CARTO SoundstarⓇ and its location was compared with contrast esophagography saved in Carto UNIVU™. LAPWT adjacent to the esophagus was measured at 4 levels: left superior PV (LSPV), intervenous carina (IC), left inferior PV (LIPV), and LIPV bottom. A target AI value was 260 (25 W power) on the esophagus demonstrated by ICE. RESULTS: All patients had the esophagus posterior to the left PV antrum. Creating a 3D esophagus and measurement of LAPWT with ICE was done without any complications. ICE esophagus image was completely overlapped with contrast esophagography. LAPWT (mm) was 2.8 (interquartile range, 2.5-3.2), 2.2 (1.9-2.5), 1.9 (1.8-2.1), and 2.1 (1.9-2.4) for LSPV, IC, LIPV, and LIPV bottom, respectively, while LA roof thickness was 3.2 (2.9-3.6) (P < 0.0001 by ANOVA). No residual conduction gap on the esophagus after the first circumferential PV isolation was found in 64 of 73 (88%) patients. CONCLUSIONS: ICE inserted into the LA can reliably locate and display the esophagus and its relationship to the LA. LAPWT was the thinnest at the LIPV level. AI-guided ablation targeting at AI value 260 on the esophagus seemed to be effective.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía/métodos , Esófago/diagnóstico por imagen , Esófago/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía
7.
Circ Rep ; 3(10): 559-568, 2021 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-34703933

RESUMEN

Background: The impact of high-power radiofrequency (RF) application in ablation index (AI)-guided atrial fibrillation (AF) ablation has not been elucidated. Methods and Results: We investigated 1,333 patients undergoing first AF ablation (median age 68 years; interquartile range [IQR] 61-73 years). The first 301 patients underwent AI-guided conventional power RF application (CP group), whereas the following 1,032 patients underwent high-power RF application (HP group). The minimum AI target values were 400, 360, and 260 at the left atrial anterior wall, posterior wall, and esophagus, respectively. RF power in the CP group was 30-40, 20-25, and 20 W at the anterior wall, posterior wall, and esophagus, respectively, compared with 50, 40, and 25, respectively, in the HP group. Procedure time was shorter in the HP than CP group (median 153 [IQR 129-190] vs. 180 (IQR 152-229) min; P<0.0001). The percentage of first-pass pulmonary vein isolation (69% vs. 73%; P=0.07) and all procedure-related complications (2.0% vs. 3.4%; P=0.19) was similar. Kaplan-Meier analysis showed similar recurrence-free survival (RFS) for all AF types. Respective 1-year RFS in the CP and HP groups was 82% and 87% in paroxysmal AF, 78% and 82% in persistent AF, and 59% and 58% in long-standing persistent AF. Conclusions: In AI-guided AF ablation, high-power RF application shortens the procedure time without increasing complications and with similar outcomes.

9.
J Interv Card Electrophysiol ; 58(3): 289-297, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31367961

RESUMEN

PURPOSE: Cryoenergy has been demonstrated to be a safe alternative to radiofrequency ablation for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT). This study aimed to evaluate the safety and efficacy of cryoablation in patients with AVNRT. METHODS: A multicenter retrospective study was performed. Two hundred eighty-three consecutive patients with AVNRT underwent cryoablation. Cryomapping at - 30 °C and - 80 °C was performed to predict cryoablation outcome and ascertain antegrade conduction. Cryoenergy was delivered subsequently at the same spot (cryoablation at - 80 °C) for 240 s. RESULTS: Ablation procedure was acutely successful in 281 out of 283 patients (99.3%). Of note, 22 patients (10.1%) had transient AV block during the cryoablation, but no injurious effects on AV conduction were provoked during cryomapping. During a follow-up period of 367 ± 35 days, the recurrence rate was 3.9% (11 out of 281). There were no significant differences among the patients with a complete elimination of slow pathway conduction, AH jump without an echo beat, and AH jump with a single echo beat, in terms of the long-term recurrence of AVNRT. CONCLUSIONS: Cryoablation of AVNRT appears to be effective both acutely and during the long-term with a minimal risk of unwanted injuries to the conduction system. It seems to be important to monitor the antegrade conduction during cryoenergy applications, even when cryomapping demonstrates a safe location for cryoablation. The recurrence rate of AVNRT did not differ according to the properties of the residual slow pathway conduction.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Japón/epidemiología , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 30(12): 2751-2758, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31600006

RESUMEN

BACKGROUNDS: Ablation index (AI) is useful to complete circumferential pulmonary vein isolation (CPVI) for atrial fibrillation (AF), but the role of radiofrequency power in AI-guided CPVI remains to be elucidated. METHODS: We investigated 60 patients with AF undergoing AI-guided CPVI (mean age, 66 ± 9 years; nonparoxysmal AF in 16). The first 40 patients were randomly assigned to low-power (LP; n = 20) and medium-power (MP; n = 20) groups and the following 20 patients to high-power (HP). In LP, radiofrequency (RF) application was done at 30 W at the anterior and 20 W at the posterior left atrial (LA) wall, while in MP, it was at 40 W at the anterior and 30 W at the posterior LA wall. In HP, 50 W was applied at the anterior, 40 W at posterior LA wall and 30 W on the esophagus. At each ablation point, target AI was 400 at the anterior, 360 at the posterior LA wall, and 260 on the esophagus. RESULTS: The time to complete both-side CPVI was shortest in HP (median, 40 minutes, interquartile range [IQR], 28-63) followed by MP (58 [49-83] minutes, P = .008 vs HP) and LP (84 [72-93] minutes, P = .002 vs MP). Higher RF power application significantly increased first-pass isolation rate (55% in LP, 80% in MP and 85% in HP, P = .002) and decreased LA-PV reconnection rate (10% in LP, 8% in MP, and 0% in HP, P = .03). CONCLUSION: In AI-guided PVI, the HP RF application can shorten the time to complete PVI with a high rate of first-pass isolation and a low rate of LA-PV reconnection.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Tempo Operativo , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Circ J ; 82(6): 1546-1551, 2018 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-29643282

RESUMEN

BACKGROUND: The entirely subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced as a new alternative to conventional transvenous ICD (TV-ICD) in Japan in February 2016, but its safety and efficacy are unclear.Methods and Results:A total of 60 patients (48 men, median age, 60 years; IQR, 44-67 years; primary prevention, n=24) underwent S-ICD implantation between February 2016 and August 2017. The device pocket was formed in the intermuscular space between the serratus anterior muscle and the latissimus dorsi muscle, and the parasternal S-ICD lead was placed according to pre-implant screening. Defibrillation test was performed in 56 patients (93%). Ventricular fibrillation (VF) was induced in 55 patients and terminated by a single 65-J shock in all patients. The median time to shock therapy was 13.4 s (IQR, 12.1-14.9 s) and the median post-shock impedance of the S-ICD lead was 64 Ω (IQR, 58-77 Ω). There were no operation-related complications or subsequent infectious complications. During follow-up (median, 275 days; IQR, 107-421 days), 1 patient (1.7%) had appropriate shock for VF with successful termination, whereas 5 patients (8.3%) had inappropriate shock due to oversensing of myopotential (n=3) or T-wave (n=1), and detection of supraventricular tachycardia (n=1). CONCLUSIONS: S-ICD is a safe and effective alternative to conventional TV-ICD. The long-term safety and efficacy of the S-ICD need further investigation.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/normas , Fibrilación Ventricular/terapia , Adulto , Anciano , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/métodos , Cardioversión Eléctrica/normas , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Prevención Primaria/métodos , Prevención Primaria/normas , Prevención Secundaria/métodos , Prevención Secundaria/normas , Taquicardia/diagnóstico , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico
12.
Europace ; 17(6): 909-14, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25825455

RESUMEN

AIMS: An electrical short circuit is a rare complication in a high-voltage implantable cardioverter-defibrillator (ICD). However, the inability of an ICD to deliver appropriate shock therapy can be life-threatening. METHODS AND RESULTS: During the last 2 years, four cases of serious complications related to an electrical short circuit have been reported in Japan. A spark due to an electrical short circuit resulted in the failure of an ICD shock to terminate ventricular tachycardia and total damage to the ICD generator in three of four cases. Two of the four patients died from an electrical short circuit between the right ventricle and superior vena cava (SVC) leads. The others had audible sounds from the ICD generator site and were diagnosed with a lead-to-can abrasion, which was manifested by the arc mark on the surface of the can. CONCLUSION: It is still difficult to predict the occurrence of an electrical short circuit in current ICD systems. To reduce the probability of an electrical short circuit, we suggest the following: (i) avoid lead stress at ICD implantation, (ii) select a single-coil lead instead of a dual-coil lead, or (iii) use a unique algorithm which automatically disconnect can or SVC lead from shock deliver circuit when excessive current was detected.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Falla de Equipo , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Adulto , Impedancia Eléctrica , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad
13.
Life Sci ; 84(11-12): 380-7, 2009 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-19167409

RESUMEN

AIMS: In the type 3 long QT syndrome (LQT3), shortening of the QT interval by overdrive pacing is used to prevent life-threatening arrhythmias. However, it is unclear whether accelerated heart rate induced by beta-adrenergic agents produces similar effects on the late sodium current (I(Na)) to those by overdrive pacing therapy. We analyzed the beta-adrenergic-like effects of protein kinase A and fluoride on I(Na) in R1623Q mutant channels. MAIN METHODS: cDNA encoding either wild-type (WT) or R1623Q mutant of hNa(v)1.5 was stably transfected into HEK293 cells. I(Na) was recorded using a whole-cell patch-clamp technique at 23 degrees C. KEY FINDINGS: In R1623Q channels, 2 mM pCPT-AMP and 120 mM fluoride significantly delayed macroscopic current decay and increased relative amplitude of the late I(Na) in a time-dependent manner. Modulations of peak I(Na) gating kinetics (activation, inactivation, recovery from inactivation) by fluoride were similar in WT and R1623Q channels. The effects of fluoride were almost completely abolished by concomitant dialysis with a protein kinase inhibitor. We also compared the effect of pacing with that of beta-adrenergic stimulation by analyzing the frequency-dependence of the late I(Na). Fluoride augmented frequency-dependent reduction of the late I(Na), which was due to preferential delay of recovery of late I(Na). However, the increase in late I(Na) by fluoride at steady-state was more potent than the frequency-dependent reduction of late I(Na). SIGNIFICANCE: Different basic mechanisms participate in the QT interval shortening by pacing and beta-adrenergic stimulation in the LQT3.


Asunto(s)
Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Activación del Canal Iónico , Síndrome de QT Prolongado/metabolismo , Proteínas Musculares/genética , Canales de Sodio/genética , Potenciales de Acción/efectos de los fármacos , Línea Celular , Clonación Molecular , AMP Cíclico/análogos & derivados , AMP Cíclico/farmacología , Proteínas Quinasas Dependientes de AMP Cíclico/antagonistas & inhibidores , Fluoruros/farmacología , Humanos , Activación del Canal Iónico/efectos de los fármacos , Síndrome de QT Prolongado/enzimología , Síndrome de QT Prolongado/genética , Mutación , Canal de Sodio Activado por Voltaje NAV1.5 , Técnicas de Placa-Clamp , Inhibidores de Proteínas Quinasas/farmacología , Tionucleótidos/farmacología , Transfección
14.
J Cardiovasc Electrophysiol ; 19(7): 702-7, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18284495

RESUMEN

OBJECTIVES: We compared, in patients with sick sinus syndrome, the effects of various pacing modes on baroreceptor (BR)-stroke volume (SV) reflex sensitivity, a method we have closely correlated with BR-heart rate (HR) reflex sensitivity. BACKGROUND: Impaired autonomic nervous function, such as decreased BR-HR reflex sensitivity, predicts sudden cardiac death. However, in patients with sick sinus syndrome, the effects of various pacing modes on autonomic function are unknown, since chronotropic incompetence precludes its evaluation by measurements of BR-HR reflex sensitivity. METHODS: We studied 12 recipients of dual-chamber pacemakers with sick sinus syndrome (mean age = 73 +/- 8 years; 8 men). Beat-by-beat blood pressure (BP) and SV were measured during 5-minute runs of AAI, DDD, and VVI pacing, and spectrally analyzed to assess BR-SV reflex sensitivity. RESULTS: Systolic BP was significantly lower (P < 0.01) during VVI (109 +/- 24 mmHg) than during DDD (124 +/- 22 mmHg) or AAI (125 +/- 41 mmHg) pacing. SV was significantly smaller during VVI (36 +/- 23 mL) than during DDD (49 +/- 31 mL) pacing (P < 0.05). BR-SV reflex sensitivity was significantly lower (P < 0.05) during VVI (9.3 +/- 5.7% per mmHg) than during DDD (15.0 +/- 6.5% per mmHg) or AAI (15.5 +/- 6.2% per mmHg) pacing. CONCLUSIONS: BR-SV reflex sensitivity was significantly lower during VVI than during AAI or DDD pacing. Atrioventricular synchrony plays an important role in the preservation of BR-SV reflex sensitivity in pacemaker recipients.


Asunto(s)
Barorreflejo , Presión Sanguínea , Estimulación Cardíaca Artificial/métodos , Frecuencia Cardíaca , Marcapaso Artificial , Síndrome del Seno Enfermo/prevención & control , Síndrome del Seno Enfermo/fisiopatología , Volumen Sistólico , Anciano , Femenino , Humanos , Masculino , Resultado del Tratamiento
15.
Heart Vessels ; 22(3): 193-8, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17533524

RESUMEN

Upper-extremity central venous obstruction is often first recognized when an arteriovenous fistula is made for hemodialysis at an ipsilateral site. We encountered a case of markedly expanded edema after making an arteriovenous fistula in the left forearm. Systemic venography showed that the bilateral brachiocephalic veins and right subclavian vein were occluded. Implantation of a self-expandable stent in the left brachiocephalic vein relieved the edema. However, recurrence of similar edema and occlusion of the left brachiocephalic vein were noted after 1.5 years. The left brachiocephalic vein was then recanalized by ballooning and additional stent implantation, and a stent was implanted between the superior vena cava and right subclavian vein. Simultaneous reconstruction of the bilateral central venous obstruction by percutaneous intervention rather than surgical repair was suitable for this patient because of previous thoracoplasty. We also believe that this method can provide an opportunity to select the suitable forearm for making an arteriovenous fistula, in which the ipsilateral central vein will exhibit little restenosis.


Asunto(s)
Cateterismo Venoso Central/efectos adversos , Catéteres de Permanencia/efectos adversos , Oclusión de Injerto Vascular/etiología , Diálisis Renal , Stents , Anciano , Derivación Arteriovenosa Quirúrgica , Remoción de Dispositivos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/terapia , Humanos , Fallo Renal Crónico/terapia , Masculino , Flebografía
16.
J Cardiovasc Electrophysiol ; 17(5): 526-31, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16684027

RESUMEN

INTRODUCTION: Conventional baroreceptor-heart rate (HR) reflex sensitivity cannot be examined in chronotropically incompetent patients or in pacemaker recipients. However, cardiac baroreceptor reflex sensitivity (BRS)-stroke volume (SV), which is closely and linearly correlated with BRS-HR, may be an alternative in that population. The aim of this study was to compare the BRS-SV in pacemaker recipients with a fixed HR paced in VVI versus DDD modes in the supine and upright positions. METHODS: The pacing mode was set randomly to DDD or VVI with complete atrial and/or ventricular capture, then crossed over to the alternate mode in 9 recipients of dual-chamber pacemakers with atrioventricular (AV) block. Beat-to-beat mean blood pressure and SV were measured in the supine and upright positions, using a tilt table. The BRS-SV, expressed in %/mmHg, was the ratio of low-frequency (LF) power to total power (TP) of SV variability, measured by spectral analysis of spontaneous variations in mean blood pressure and SV. RESULTS: BRS-SV was significantly lower in the VVI than in the DDD mode in the supine (37.2 +/- 26.7 vs 14.5 +/- 7.7%/mmHg) and upright (22.9 +/- 16.9 vs 10.6 +/- 6.6%/mmHg) positions (P < 0.05 for both comparisons). CONCLUSIONS: VVI pacing is adverse from the standpoint of cardiac autonomic baroreflex function. A decreased BRS-SV may be one of the factors involved in the hemodynamic intolerance associated with VVI pacing.


Asunto(s)
Fibrilación Atrial/prevención & control , Fibrilación Atrial/fisiopatología , Barorreflejo , Presión Sanguínea , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco/fisiopatología , Volumen Sistólico , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad