Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Med Dosim ; 49(3): 271-275, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38556402

RESUMEN

The increase in high-precision radiation therapy, particularly volumetric-modulated arc therapy (VMAT), has increased patient numbers and expanded treatment sites. However, a significant challenge in VMAT treatment planning is the inconsistent plan quality among different planners and facilities. This study explored the use of dose-volume histogram (DVH) prediction tools to address these disparities, specifically focusing on RapidPlan (Varian Medical Systems) and PlanIQ (Sun Nuclear). RapidPlan predicts achievable DVHs and automatically generates optimization objectives. While it has demonstrated organ-at-risk (OAR) dose reduction benefits, the quality of the plan used to build its model significantly affects its predictions. On the other hand, PlanIQ offers ease of use and does not require prior model-building. Five planners participated in this study, each creating two treatment plans: one referencing RapidPlan and the other using PlanIQ. The planners had the freedom to adjust parameters while referencing the DVH predictions. The plans were evaluated using "Plan Quality Metric" (PQM) scores to assess the planning target volume excluding the rectum and OARs. The results revealed that RapidPlan-referenced plans often outperformed PlanIQ-based plans, with less interplanner variability. PlanIQ played a pivotal role in the construction of the RapidPlan model. This study is the first to compare plans generated by multiple planners using both tools. This study provides insights into optimizing treatment planning by considering the characteristics of both RapidPlan and PlanIQ.


Asunto(s)
Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Humanos , Órganos en Riesgo
2.
Rep Pract Oncol Radiother ; 28(5): 671-680, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38179286

RESUMEN

Background: The quality of treatment planning for stage III non-small cell lung cancer varies within and between facilities due to the different professions involved in planning. Dose estimation parameters were calculated using a feasibility dose-volume histogram (FDVH) implemented in the treatment planning quality assurance software PlanIQ. This study aimed to evaluate differences in treatment planning between occupations using manual FDVH-referenced treatment planning to identify their characteristics. Materials and methods: The study included ten patients with stage III non-small cell lung cancer, and volumetric-modulated arc therapy was used as the treatment planning technique. Fifteen planners, comprising five radiation oncologists, five medical physicists, and five radiological technologists, developed treatment strategies after referring to the FDVH. Results: Medical physicists had a higher mean dose at D98% of the planning target volume (PTV) and a lower mean dose at D2% of the PTV than those in other occupations. Medical physicists had the lowest irradiation lung volumes (V5 Gy and V13 Gy) compared to other professions, and radiation oncologists had the lowest V20 Gy and mean lung dose. Radiological technologists had the highest irradiation volumes for dose constraints at all indexes on the normal lung volume. Conclusions: The quality of the treatment plans developed in this study differed between occupations due to their background expertise, even when an FDVH was used as a reference. Therefore, discussing and sharing knowledge and treatment planning techniques among professionals is essential to determine the optimal treatment plan for each facility and patient.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...