RESUMEN
Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.
RESUMEN
The COVID-19 pandemic led to development of numerous serologic tests. To obviate the need for phlebotomy services, we validated dried blood spots (DBS) for anti-SARS-CoV-2 serologic testing. Immunoglobulins were extracted from 3 mm DBS punches and the extracts were analyzed using the Euroimmun anti-SARS-CoV-2 IgG ELISA. Various pre-analytical factors were studied. Results were favorable for DBS stored for at least 67 days at or below 37°C. Comparison between paired serum and DBS specimens tested by the Euroimmun ELISA showed 96.8% and 81.3% positive and negative agreement, respectively, indicating that confirmatory testing of positive Euroimmun results on DBS extracts is necessary to achieve clinical accuracy. Our findings suggest that any SARS-CoV-2 antibody assay that requires pre-dilution of serum is amenable to DBS as an alternate specimen type that is relatively low cost, self-collectable, stable, can be shipped by standard mail and could be used to establish the seroprevalence of large populations.
Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19 , COVID-19/diagnóstico , Pruebas con Sangre Seca , Inmunoglobulina G/sangre , SARS-CoV-2/aislamiento & purificación , Prueba Serológica para COVID-19/instrumentación , Pruebas con Sangre Seca/instrumentación , Ensayo de Inmunoadsorción Enzimática , Humanos , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Manejo de EspecímenesRESUMEN
BACKGROUND: Dried blood spots (DBS) are an established specimen type for clinical testing given their low cost, ease of collection and storage, and convenient shipping capabilities through the postal system. These attributes are complementary to the expansion of SARS-CoV-2 serologic testing, which may be used to inform community seroprevalence rates. METHODS: The Luminex xMAP SARS-CoV-2 Multi-Antigen assay utilizes magnetic beads labeled with three viral antigens (nucleocapsid [NC], receptor binding domain [RBD], spike S1 subunit) to detect anti-viral IgG-class antibodies, and has Food and Drug Administration (FDA) Emergency Use Authorization (EUA) for use in serum and plasma. This assay was modified for use with DBS and validated against paired sera tested by one of two reference assays: the Roche Diagnostics Elecsys anti-SARS-CoV-2 ECLIA or the Euroimmun anti-SARS-CoV-2 IgG ELISA. RESULTS: 159 paired DBS and serum specimens analyzed using the modified Luminex xMAP assay on DBS and the reference methods on serum showed an overall concordance of 96.9% (154/159). Use of multivariate pattern recognition software (CLIR) for post-analytical interpretation of the Luminex xMAP DBS assay results, instead of manufacturer provided interpretive thresholds, increased overall qualitative result concordance to 99.4% (158/159) between the modified Luminex xMAP DBS and reference results. CONCLUSIONS: Use of DBS for detection of antibodies against SARS-CoV-2 provides comparable results to those obtained using serum. DBS concordance was improved with multivariate pattern recognition software (CLIR). We demonstrate that DBS are a reliable specimen type for SARS-CoV-2 antibody detection using the modified Luminex xMAP assay.
Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19 , COVID-19/sangre , Pruebas con Sangre Seca , Inmunoglobulina G/sangre , SARS-CoV-2 , Adulto , Anciano , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
OBJECTIVE: To estimate the seroprevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in health care personnel. METHODS: The Mayo Clinic Serology Screening Program was created to provide a voluntary, two-stage testing program for SARS-CoV-2 antibodies to health care personnel. The first stage used a dried blood spot screening test initiated on June 15, 2020. Those participants identified as reactive were advised to have confirmatory testing via a venipuncture. Venipuncture results through August 8, 2020, were considered. Consent and authorization for testing was required to participate in the screening program. This report, which was conducted under an institutional review board-approved protocol, only includes employees who have further authorized their records for use in research. RESULTS: A total of 81,113 health care personnel were eligible for the program, and of these 29,606 participated in the screening program. A total of 4284 (14.5%) of the dried blood spot test results were "reactive" and warranted confirmatory testing. Confirmatory testing was completed on 4094 (95.6%) of the screen reactive with an overall seroprevalence rate of 0.60% (95% CI, 0.52% to 0.69%). Significant variation in seroprevalence was observed by region of the country and age group. CONCLUSION: The seroprevalence for SARS-CoV-2 antibodies through August 8, 2020, was found to be lower than previously reported in other health care organizations. There was an observation that seroprevalence may be associated with community disease burden.
Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19 , COVID-19 , Transmisión de Enfermedad Infecciosa/estadística & datos numéricos , Personal de Salud/estadística & datos numéricos , SARS-CoV-2 , Centros Médicos Académicos , Adulto , COVID-19/sangre , COVID-19/epidemiología , COVID-19/terapia , Prueba Serológica para COVID-19/métodos , Prueba Serológica para COVID-19/estadística & datos numéricos , Femenino , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Salud Pública/métodos , SARS-CoV-2/inmunología , SARS-CoV-2/aislamiento & purificación , Estudios Seroepidemiológicos , Análisis Espacio-Temporal , Estados Unidos/epidemiologíaRESUMEN
Glycosylation is a critical post/peri-translational modification required for the appropriate development and function of the immune system. As an example, abnormalities in glycosylation can cause antibody deficiency and reduced lymphocyte signaling, although the phenotype can be complex given the diverse roles of glycosylation. Human MGAT2 encodes N-acetylglucosaminyltransferase II, which is a critical enzyme in the processing of oligomannose to complex N-glycans. Complex N-glycans are essential for immune system functionality, but only one individual with MGAT2-CDG has been described to have an abnormal immunologic evaluation. MGAT2-CDG (CDG-IIa) is a congenital disorder of glycosylation (CDG) associated with profound global developmental disability, hypotonia, early onset epilepsy, and other multisystem manifestations. Here, we report a 4-year old female with MGAT2-CDG due to a novel homozygous pathogenic variant in MGAT2, a 4-base pair deletion, c.1006_1009delGACA. In addition to clinical features previously described in MGAT2-CDG, she experienced episodic asystole, persistent hypogammaglobulinemia, and defective ex vivo mitogen and antigen proliferative responses, but intact specific vaccine antibody titers. Her infection history has been mild despite the testing abnormalities. We compare this patient to the 15 previously reported patients in the literature, thus expanding both the genotypic and phenotypic spectrum for MGAT2-CDG.
Asunto(s)
Arritmias Cardíacas/genética , Trastornos Congénitos de Glicosilación/genética , Enfermedades del Sistema Inmune/genética , N-Acetilglucosaminiltransferasas/genética , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/inmunología , Arritmias Cardíacas/patología , Preescolar , Trastornos Congénitos de Glicosilación/complicaciones , Trastornos Congénitos de Glicosilación/inmunología , Trastornos Congénitos de Glicosilación/patología , Femenino , Glicosilación , Homocigoto , Humanos , Enfermedades del Sistema Inmune/complicaciones , Enfermedades del Sistema Inmune/inmunología , Enfermedades del Sistema Inmune/patología , Mutación/genética , N-Acetilglucosaminiltransferasas/inmunología , FenotipoRESUMEN
BACKGROUND AND AIMS: Altered bile acid (BA) homeostasis is an intrinsic facet of cholestatic liver diseases, but clinical usefulness of plasma BA assessment in primary sclerosing cholangitis (PSC) remains understudied. We performed BA profiling in a large retrospective cohort of patients with PSC and matched healthy controls, hypothesizing that plasma BA profiles vary among patients and have clinical utility. APPROACH AND RESULTS: Plasma BA profiling was performed in the Clinical Biochemical Genetics Laboratory at Mayo Clinic using a mass spectrometry based assay. Cox proportional hazard (univariate) and gradient boosting machines (multivariable) models were used to evaluate whether BA variables predict 5-year risk of hepatic decompensation (HD; defined as ascites, variceal hemorrhage, or encephalopathy). There were 400 patients with PSC and 302 controls in the derivation cohort (Mayo Clinic) and 108 patients with PSC in the validation cohort (Norwegian PSC Research Center). Patients with PSC had increased BA levels, conjugated fraction, and primary-to-secondary BA ratios relative to controls. Ursodeoxycholic acid (UDCA) increased total plasma BA level while lowering cholic acid and chenodeoxycholic acid concentrations. Patients without inflammatory bowel disease (IBD) had primary-to-secondary BA ratios between those of controls and patients with ulcerative colitis. HD risk was associated with increased concentration and conjugated fraction of many BA, whereas higher G:T conjugation ratios were protective. The machine-learning model, PSC-BA profile score (concordance statistic [C-statistic], 0.95), predicted HD better than individual measures, including alkaline phosphatase, and performed well in validation (C-statistic, 0.86). CONCLUSIONS: Patients with PSC demonstrated alterations of plasma BA consistent with known mechanisms of cholestasis, UDCA treatment, and IBD. Notably, BA profiles predicted future HD, establishing the clinical potential of BA profiling, which may be suited for use in clinical trials.
Asunto(s)
Ascitis/epidemiología , Ácidos y Sales Biliares/sangre , Colangitis Esclerosante/complicaciones , Várices Esofágicas y Gástricas/epidemiología , Encefalopatía Hepática/epidemiología , Adulto , Anciano , Ascitis/etiología , Estudios de Casos y Controles , Colangitis Esclerosante/sangre , Colangitis Esclerosante/fisiopatología , Várices Esofágicas y Gástricas/etiología , Estudios de Factibilidad , Femenino , Voluntarios Sanos , Encefalopatía Hepática/etiología , Humanos , Hígado/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo/métodosRESUMEN
Short-chain acyl-CoA dehydrogenase deficiency (SCADD) is a rare autosomal recessive disorder of ß-oxidation caused by pathogenic variants in the ACADS gene. Analyte testing for SCADD in blood and urine, including newborn screening (NBS) using tandem mass spectrometry (MS/MS) on dried blood spots (DBSs), is complicated by the presence of two relatively common ACADS variants (c.625G>A and c.511C>T). Individuals homozygous for these variants or compound heterozygous do not have clinical disease but do have reduced short-chain acyl-CoA dehydrogenase (SCAD) activity, resulting in elevated blood and urine metabolites. As part of a larger study of the potential role of exome sequencing in NBS in California, we reviewed ACADS sequence and MS/MS data from DBSs from a cohort of 74 patients identified to have SCADD. Of this cohort, approximately 60% had one or more of the common variants and did not have the two rare variants, and thus would need no further testing. Retrospective analysis of ethylmalonic acid, glutaric acid, 2-hydroxyglutaric acid, 3-hydroxyglutaric acid, and methylsuccinic acid demonstrated that second-tier testing applied before the release of the newborn screening result could reduce referrals by over 50% and improve the positive predictive value for SCADD to above 75%.
RESUMEN
Newborn screening for one or more lysosomal disorders has been implemented in several US states, Japan and Taiwan by multiplexed enzyme assays using either tandem mass spectrometry or digital microfluidics. Another multiplex assay making use of immunocapture technology has also been proposed. To investigate the potential variability in performance of these analytical approaches, we implemented three high-throughput screening assays for the simultaneous screening for four lysosomal disorders: Fabry disease, Gaucher disease, mucopolysaccharidosis type I, and Pompe disease. These assays were tested in a prospective comparative effectiveness study using nearly 100,000 residual newborn dried blood spot specimens. In addition, 2nd tier enzyme assays and confirmatory molecular genetic testing were employed. Post-analytical interpretive tools were created using the software Collaborative Laboratory Integrated Reports (CLIR) to determine its ability to improve the performance of each assay vs. the traditional result interpretation based on analyte-specific reference ranges and cutoffs. This study showed that all three platforms have high sensitivity, and the application of CLIR tools markedly improves the performance of each platform while reducing the need for 2nd tier testing by 66% to 95%. Moreover, the addition of disease-specific biochemical 2nd tier tests ensures the lowest false positive rates and the highest positive predictive values for any platform.
RESUMEN
Measurement of the absolute concentration of the biomarker psychosine in dried blood spots (DBS) is useful for diagnosis and prognosis of Krabbe disease and to support newborn screening of this leukodystrophy. As for assays for more common diseases, it is important to achieve congruence when multiple clinical laboratories provide testing. Four clinical laboratories, one research laboratory, and a commercial vendor collaborated with the goal to achieve congruence in quantitative psychosine measurement in DBS. A set of DBS calibrators was prepared by a single vendor and used in each reference laboratory to make a standard curve of measured psychosine in DBS versus the stated calibrator psychosine level. Congruence between the participating five laboratories was achieved using the psychosine DBS calibrators. This allowed application of disease-specific reference ranges obtained by the reference laboratory with the most extensive data by the other reference laboratories. Congruence between multiple reference laboratories in the measurement of the absolute concentration of biomarkers in DBS (and by extension other samples) is possible by the use of a common set of DBS calibrators.
RESUMEN
PURPOSE: Newborn screening (NBS) for Krabbe disease (KD) is performed by measurement of galactocerebrosidase (GALC) activity as the primary test. This revealed that GALC activity has poor specificity for KD. Psychosine (PSY) was proposed as a disease marker useful to reduce the false positive rate for NBS and for disease monitoring. We report a highly sensitive PSY assay that allows identification of KD patients with minimal PSY elevations. METHODS: PSY was extracted from dried blood spots or erythrocytes with methanol containing d5-PSY as internal standard, and measured by liquid chromatography-tandem mass spectrometry. RESULTS: Analysis of PSY in samples from controls (N = 209), GALC pseudodeficiency carriers (N = 55), GALC pathogenic variant carriers (N = 27), patients with infantile KD (N = 26), and patients with late-onset KD (N = 11) allowed for the development of an effective laboratory screening and diagnostic algorithm. Additional longitudinal measurements were used to track therapeutic efficacy of hematopoietic stem cell transplantion (HSCT). CONCLUSION: This study supports PSY quantitation as a critical component of NBS for KD. It helps to differentiate infantile from later onset KD variants, as well as from GALC variant and pseudodeficiency carriers. Additionally, this study provides further data that PSY measurement can be useful to monitor KD progression before and after treatment.
Asunto(s)
Leucodistrofia de Células Globoides , Psicosina , Pruebas con Sangre Seca , Galactosilceramidasa/genética , Humanos , Recién Nacido , Leucodistrofia de Células Globoides/diagnóstico , Leucodistrofia de Células Globoides/genética , Tamizaje NeonatalRESUMEN
The conserved oligomeric Golgi (COG) complex is involved in intracellular vesicular transport, and is composed of eight subunits distributed in two lobes, lobe A (COG1-4) and lobe B (COG5-8). We describe fourteen individuals with Saul-Wilson syndrome, a rare form of primordial dwarfism with characteristic facial and radiographic features. All affected subjects harbored heterozygous de novo variants in COG4, giving rise to the same recurrent amino acid substitution (p.Gly516Arg). Affected individuals' fibroblasts, whose COG4 mRNA and protein were not decreased, exhibited delayed anterograde vesicular trafficking from the ER to the Golgi and accelerated retrograde vesicular recycling from the Golgi to the ER. This altered steady-state equilibrium led to a decrease in Golgi volume, as well as morphologic abnormalities with collapse of the Golgi stacks. Despite these abnormalities of the Golgi apparatus, protein glycosylation in sera and fibroblasts from affected subjects was not notably altered, but decorin, a proteoglycan secreted into the extracellular matrix, showed altered Golgi-dependent glycosylation. In summary, we define a specific heterozygous COG4 substitution as the molecular basis of Saul-Wilson syndrome, a rare skeletal dysplasia distinct from biallelic COG4-CDG.
Asunto(s)
Síndrome del Cromosoma X Frágil/genética , Transporte de Proteínas/genética , Proteoglicanos/genética , Proteínas de Transporte Vesicular/genética , Adulto , Sustitución de Aminoácidos/genética , Animales , Animales Modificados Genéticamente/genética , Línea Celular , Niño , Preescolar , Retículo Endoplásmico/genética , Matriz Extracelular/genética , Femenino , Fibroblastos/patología , Glicosilación , Aparato de Golgi/genética , Heterocigoto , Humanos , Lactante , Masculino , Pez CebraRESUMEN
PURPOSE: The implementation of newborn screening for lysosomal disorders has uncovered overall poor specificity, psychosocial harm experienced by caregivers, and costly follow-up testing of false-positive cases. We report an informatics solution proven to minimize these issues. METHODS: The Kentucky Department for Public Health outsourced testing for mucopolysaccharidosis type I (MPS I) and Pompe disease, conditions recently added to the recommended uniform screening panel, plus Krabbe disease, which was added by legislative mandate. A total of 55,161 specimens were collected from infants born over 1 year starting from February 2016. Testing by tandem mass spectrometry was integrated with multivariate pattern recognition software (Collaborative Laboratory Integrated Reports), which is freely available to newborn screening programs for selection of cases for which a biochemical second-tier test is needed. RESULTS: Of five presumptive positive cases, one was affected with infantile Krabbe disease, two with Pompe disease, and one with MPS I. The remaining case was a heterozygote for the latter condition. The false-positive rate was 0.0018% and the positive predictive value was 80%. CONCLUSION: Postanalytical interpretive tools can drastically reduce false-positive outcomes, with preliminary evidence of no greater risk of false-negative events, still to be verified by long-term surveillance.
Asunto(s)
Enfermedades por Almacenamiento Lisosomal/diagnóstico , Tamizaje Neonatal/métodos , Pruebas con Sangre Seca , Femenino , Enfermedad del Almacenamiento de Glucógeno Tipo II/diagnóstico , Humanos , Lactante , Recién Nacido , Leucodistrofia de Células Globoides/diagnóstico , Masculino , Mucopolisacaridosis I/diagnóstico , Reconocimiento de Normas Patrones Automatizadas , Sensibilidad y Especificidad , Programas Informáticos , Espectrometría de Masas en Tándem/métodosRESUMEN
BACKGROUND: Newborn screening for lysosomal storage disorders (LSD) has revealed that late-onset variants of these conditions are unexpectedly frequent and therefore may evade diagnosis. We developed an efficient and cost-effective multiplex assay to diagnose six LSDs and several peroxisomal disorders in patients presenting with diverse phenotypes at any age. METHODS: Three 3-mm dried blood spot (DBS) punches were placed into individual microtiter plates. One disc was treated with a cocktail containing acid sphingomyelinase-specific substrate and internal standard (IS). To the second DBS we added a cocktail containing substrate and IS for ß-glucosidase, acid α-glucosidase, α-galactosidase A, galactocerebrosidase, and α-L-iduronidase. The third DBS was extracted with methanol containing d4-C26 lysophosphatidylcholine as IS and stored until the enzyme plates were combined and purified by liquid-liquid and solid-phase extraction. The extracts were evaporated, reconstituted with the extract from the lysophosphatidylcholine plate, and analyzed by flow injection tandem mass spectrometry. RESULTS: Reference intervals were determined by analysis of 550 samples from healthy controls. DBS from confirmed patients with 1 of the 6 LSDs (n = 33), X-adrenoleukodystrophy (n = 9), or a peroxisomal biogenesis disorder (n = 5), as well as carriers for Fabry disease (n = 17) and X-adrenoleukodystrophy (n = 5), were analyzed for assay validation. Prospective clinical testing of 578 samples revealed 25 patients affected with 1 of the detectable conditions. CONCLUSIONS: Our flow injection tandem mass spectrometry approach is amenable to high-throughput population screening for Hurler disease, Gaucher disease, Niemann-Pick A/B disease, Pompe disease, Krabbe disease, Fabry disease, X-adrenoleukodystrophy, and peroxisomal biogenesis disorder in DBS.
Asunto(s)
Adrenoleucodistrofia/sangre , Pruebas con Sangre Seca , Enfermedades por Almacenamiento Lisosomal/sangre , Adrenoleucodistrofia/diagnóstico , Humanos , Enfermedades por Almacenamiento Lisosomal/diagnóstico , Espectrometría de Masas en TándemRESUMEN
BACKGROUND: Newborn screening (NBS) for Krabbe disease (KD) in New York and Missouri is conducted by measuring galactocerebrosidase (GALC) activity using tandem mass spectrometry (MS/MS). These NBS efforts have shown that the incidence of KD is unexpectedly low (1:400,000) while many individuals (ca. 1:6000) with reduced GALC activity and genotypes of uncertain significance are detected and subjected to follow up testing. Psychosine (PSY) is a putative marker of KD progression and can be measured in dried blood spots (DBS). We sought to determine the role that PSY levels play in NBS for KD, follow up, and treatment monitoring. METHODS: PSY was eluted from DBS with methanol containing N,N-dimethyl-D-erythro-sphingosine as internal standard (IS). Liquid chromatography-MS/MS was conducted over 17 minutes in the multiple reaction monitoring positive mode to follow the precursor to product species transitions for PSY and IS. Separation of the structural isomers PSY and glucosylsphingosine was accomplished by hydrophilic interaction liquid chromatography. RESULTS: Pre-analytical and analytical factors were studied and revealed satisfactory results. PSY was also measured in DBS collected from controls (range: <8 nmol/L, N = 220), KD patients at various disease stages (range: 8-112, N = 26), and GALC mutation carriers (range: <15 nmol/L, N = 18). CONCLUSIONS: PSY measurement in DBS could serve as a 2nd tier assay in NBS for KD, simplify and reduce the cost of follow up protocols, help determine disease progression, and be used to monitor KD patients following hematopoietic stem cell transplantation. However, additional chronological measurements of PSY in KD patients are required to confirm these possibilities.
Asunto(s)
Pruebas con Sangre Seca , Leucodistrofia de Células Globoides/diagnóstico , Tamizaje Neonatal/métodos , Psicosina/sangre , Adolescente , Adulto , Anciano , Niño , Preescolar , Pruebas con Sangre Seca/normas , Humanos , Lactante , Recién Nacido , Leucodistrofia de Células Globoides/sangre , Límite de Detección , Persona de Mediana Edad , Tamizaje Neonatal/normas , Psicosina/análisis , Mejoramiento de la Calidad , Valores de Referencia , Reproducibilidad de los Resultados , Adulto JovenRESUMEN
BACKGROUND: Pre-symptomatic hematopoietic stem cell transplantation is essential to achieve best possible outcomes for patients with the childhood cerebral form of X-linked adrenoleukodystrophy (X-ALD). We describe a high-throughput method for measurement of C20-C26 lysophosphatidylcholines (LPCs) and biochemical diagnosis of X-ALD using the same dried blood spots (DBS) routinely used for newborn screening. METHODS: LPCs are extracted from 3-mm DBS punch with methanol containing an isotopically labeled LPC as internal standard. This extract is transferred to a 96-well plate, evaporated and then reconstituted in mobile phase for flow injection analysis tandem mass spectrometry (FIA-MS/MS) in selected reaction monitoring mode for measurement of four different LPCs (C20, C22, C24, C26) and the internal standard (d4-C26-LPC). Analysis time is 1.5min per sample. RESULTS: The mean CVs from the intra- and inter-assay experiments for LPCs were 6.3-15.1% for C20-LPC, 4.4-18.6% for C22-LPC and 4.5-14.3% for C24-LPC. Limits of detection were determined for C20-LPC (LOD=0.03µg/mL), C22-LPC (0.03µg/mL), C24-LPC (0.03µg/mL) and C26-LPC (0.01µg/mL). Reference ranges were established from DBS of 130 newborns and 20 adults. Samples of patients with X-ALD (n=16), peroxisomal biogenesis disorders (n=8), and X-ALD carriers (n=12) were analyzed blindly and all were correctly identified. CONCLUSION: Analysis of LPC species by FIA-MS/MS is a fast, simple and reliable method to screen for X-ALD and other peroxisomal disorders in DBS. To maximize specificity, abnormal results can be verified by a 2nd tier assay using LC-MS/MS.
Asunto(s)
Adrenoleucodistrofia/sangre , Pruebas con Sangre Seca , Lisofosfatidilcolinas/sangre , Tamizaje Neonatal/métodos , Adulto , Cromatografía Liquida , Ensayos Analíticos de Alto Rendimiento , Humanos , Recién Nacido , Límite de Detección , Trastorno Peroxisomal/sangre , Valores de Referencia , Espectrometría de Masas en Tándem/métodosRESUMEN
PURPOSE: To improve quality of newborn screening by tandem mass spectrometry with a novel approach made possible by the collaboration of 154 laboratories in 49 countries. METHODS: A database of 767,464 results from 12,721 cases affected with 60 conditions was used to build multivariate pattern recognition software that generates tools integrating multiple clinically significant results into a single score. This score is determined by the overlap between normal and disease ranges, penetration within the disease range, differences between conditions, and weighted correction factors. RESULTS: Ninety tools target either a single condition or the differential diagnosis between multiple conditions. Scores are expressed as the percentile rank among all cases with the same condition and are compared to interpretation guidelines. Retrospective evaluation of past cases suggests that these tools could have avoided at least half of 279 false-positive outcomes caused by carrier status for fatty-acid oxidation disorders and could have prevented 88% of known false-negative events. CONCLUSION: Application of this computational approach to raw data is independent from single analyte cutoff values. In Minnesota, the tools have been a major contributing factor to the sustained achievement of a false-positive rate below 0.1% and a positive predictive value above 60%.
Asunto(s)
Tamizaje Neonatal/métodos , Programas Informáticos , Espectrometría de Masas en Tándem/métodos , Biología Computacional , Interpretación Estadística de Datos , Bases de Datos Factuales , Diagnóstico Diferencial , Reacciones Falso Positivas , Humanos , Recién Nacido , Cooperación Internacional , Metaboloma , Minnesota , Análisis Multivariante , Reconocimiento de Normas Patrones Automatizadas , Valor Predictivo de las Pruebas , Estudios RetrospectivosRESUMEN
BACKGROUND: Newborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: The analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d(3)-MMA, d(3)-MCA, d(8)-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening. RESULTS: The 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 µmol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants. CONCLUSIONS: Application of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations.
Asunto(s)
Citratos/sangre , Homocisteína/sangre , Ácido Metilmalónico/sangre , Recolección de Muestras de Sangre , Cromatografía Liquida , Reacciones Falso Positivas , Humanos , Recién Nacido , Límite de Detección , Tamizaje Neonatal , Valor Predictivo de las Pruebas , Valores de Referencia , Espectrometría de Masas en TándemRESUMEN
OBJECTIVE: To validate a 2-tier approach for newborn screening (NBS) of remethylation defects. STUDY DESIGN: The original NBS dried blood spots of 5 patients with a proven diagnosis of a remethylation disorder and 1 patient with biochemical evidence of such disorder were analyzed retrospectively to determine disease ranges for methionine (Met; 4.7-8.1 micromol/L; 1 percentile of healthy population, 11.1 micromol/L), the methionine/phenylalanine ratio (Met/Phe; 0.09-0.16; 1 percentile of healthy population, 0.22), and total homocysteine (tHcy; 42-157 micromol/L; 99 percentile of normal population, 14.7 micromol/L). These preliminary disease ranges showed a sufficient degree of segregation from healthy population data, allowing the selection of cutoff values. A simple algorithm was then developed to reflex cases to a second-tier testing for tHcy, which has been applied prospectively for 14 months. RESULTS: A total of 86 333 NBS samples were tested between January 2007 and March 2008, and 233 of them (0.27%) met the criteria for second-tier testing of tHcy. All cases revealed concentrations of tHcy <15 micromol/L and were considered unaffected. No false-negative results have been reported with a state-wide system based on 2 combined metabolic clinics and laboratories that cover the entire Minnesota population and border areas of neighboring states. CONCLUSIONS: Pending more conclusive evidence from the prospective identification of additional true-positive cases, NBS for remethylation disorders appears to be feasible with existing methodologies, with only a marginal increase of the laboratory workload.
Asunto(s)
Errores Innatos del Metabolismo/sangre , Metilenotetrahidrofolato Reductasa (NADPH2)/deficiencia , Tamizaje Neonatal/métodos , Espectrometría de Masas en Tándem/métodos , Algoritmos , Homocisteína/sangre , Humanos , Recién Nacido , Errores Innatos del Metabolismo/diagnóstico , Metionina/sangre , Mutación , Fenilalanina/sangre , Valores de Referencia , Reproducibilidad de los Resultados , Estudios RetrospectivosRESUMEN
Newborn screening for X-linked adrenoleukodystrophy (X-ALD) has until now been limited in implementation because of the lack of an accepted standard methodology. We have previously reported a technique using LC-MS/MS analysis that could provide the basis for screening of newborns for X-ALD. The target analyte diagnostic for X-ALD and other peroxisomal disorders of peroxisomal beta-oxidation is 1-hexacosanoyl-2-lyso-sn-3-glycero-phosphorylcholine (26:0-lyso-PC). We report here the validation of the analytical method using an authentic standard of the target compound. The method possesses sensitivity of <1.0fmole injected on column with a correlation coefficient (R(2)) of 0.9987. A tetradeuterated analog of 26:0-lyso-PC served as the internal standard. The sensitivity of this clinical method was confirmed using 17 newborn samples of individuals with peroxisomal disorders retrieved from state newborn screening programs. These samples were run masked with over 1000 newborn samples. All affected individuals were identified with one exception. One sample which was retrieved as an affected did not have the biochemical or genetic abnormality of X-ALD and thus is considered an error in sample identity. These studies clearly show that the method is highly sensitive and accurate in identifying individuals with a defect in peroxisomal beta-oxidation such as X-ALD.