Spine J ; 2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39343239

RESUMEN

BACKGROUND CONTEXT: Stabilization of the occipitocervical (OC) junction with posterior instrumentation plays a vital role in addressing a spectrum of pathologies. Due to limited bone surfaces of the occiput and C1 lamina, achieving union across the OC junction is challenging. PURPOSE: To explore the biomechanics and a clinical series of patients treated with multi-rod constructs across the OC junction using a novel occipital plate with single- and dual-headed, modular tulip heads. STUDY DESIGN/SETTING: Biomechanical analysis and retrospective case series. PATIENT SAMPLE: Adults at a single institution who underwent posterior cervical multi-rod constructs across the OC junction. OUTCOME MEASURES: OC-C4 range of motion (ROM), maximum von Mises stress on the rods, and adjacent segment ROMs and intradiscal parameters. Patient demographics, revision operations, rod breakages, wound complications. METHODS: A validated occiput-cervical finite element (FE) model was used to simulate OC-C4 cervical fixation under multi-directional pure moment loading. A total of 4 rod configurations were simulated: (A) 2-rod-Ti (4.0 mm titanium rods); (B) 2-rod-CoCr (3.5 mm cobalt chrome rods); (C) 3-rods (4.0 mm titanium rods); (D) 4-rods (4.0 mm titanium rods). The aforementioned measures were compared. A retrospective analysis was also performed of adults at a single institution who underwent posterior cervical multi-rod constructs across the OC junction. RESULTS: Biomechanically, lowest primary rod stresses were observed for 3- and 4-rod constructs. Compared to 2-rod-Ti (121.8 MPa), 2-rod-CoCr showed a 43.2% stress increase in the rods, while 3- and 4-rods experienced rod stress reductions of 20% and 23.2%, respectively. No appreciable differences in OC-C4 ROM, C4-5 ROM, and C4-5 discal stresses were found between multi-rod and 2-rod constructs. Maximum occipital and C4 screw stresses were decreased in multi-rod constructs compared to 2-rods, with least stresses noted in the 4-rod construct. Maximum plate stresses were slightly increased in the 4-rod construct compared to 2- and 3-rod fixation, though the forces were largely similar among the constructs. Ten patients (average age 66.4 ± 10.6 years; 8 males) were assessed clinically. Nine of the ten operations were for primary stabilization of pathological fractures and associated craniocervical and/or atlantoaxial instability using 4-rods across the OC junction. At an average follow-up time of 1.58 ± 0.5 years (range, 1 - 2.3 years), there were no instrumentation failures, no adjacent segment failures, and no wound complications. CONCLUSIONS: In this proof-of-concept investigation, multiple rods (3- and 4-rods) across the OC junction using a novel occipital plate with single- and dual-headed, modular tulips was safe and effective in stabilizing the OC junction. Accompanying FE analysis demonstrated that multi-rod constructs decreased primary rod stresses and had lower stresses on occipital and C4 screws compared to 2-rod constructs, while occipital plate stresses were largely similar. Additional clinical studies are needed to confirm these findings and to determine the ultimate utility of multi-rod constructs across the OC junction.

3.
Global Spine J ; 9(2): 162-168, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30984495

RESUMEN

STUDY DESIGN: Cadaveric biomechanical study. OBJECTIVES: Medial-to-lateral trajectory cortical screws are of clinical interest due to the ability to place them through a less disruptive, medialized exposure compared with conventional pedicle screws. In this study, cortical and pedicle screw trajectory stability was investigated in single-level transforaminal lumbar interbody fusion (TLIF), posterior lumbar interbody fusion (PLIF), and extreme lateral interbody fusion (XLIF) constructs. METHODS: Eight lumbar spinal units were used for each interbody/screw trajectory combination. The following constructs were tested: TLIF + unilateral facetectomy (UF) + bilateral pedicle screws (BPS), TLIF + UF + bilateral cortical screws (BCS), PLIF + medial facetectomy (MF) + BPS, PLIF + bilateral facetectomy (BF) + BPS, PLIF + MF + BCS, PLIF + BF + BCS, XLIF + BPS, XLIF + BCS, and XLIF + bilateral laminotomy + BCS. Range of motion (ROM) in flexion-extension, lateral bending, and axial rotation was assessed using pure moments. RESULTS: All instrumented constructs were significantly more rigid than intact (P < .05) in all test directions except TLIF + UF + BCS, PLIF + MF + BCS, and PLIF + BF + BCS in axial rotation. In general, XLIF and PLIF + MF constructs were more rigid (lowest ROM) than TLIF + UF and PLIF + BF constructs. In the presence of substantial iatrogenic destabilization (TLIF + UF and PLIF + BF), cortical screw constructs tended to be less rigid (higher ROM) than the same pedicle screw constructs in lateral bending and axial rotation; however, no statistically significant differences were found when comparing pedicle and cortical fixation for the same interbody procedures. CONCLUSIONS: Both cortical and pedicle trajectory screw fixation provided stability to the 1-level interbody constructs. Constructs with the least iatrogenic destabilization were most rigid. The more destabilized constructs showed less lateral bending and axial rotation rigidity with cortical screws compared with pedicle screws. Further investigation is warranted to understand the clinical implications of differences between constructs.

4.
Eur Spine J ; 27(2): 433-441, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28501956

RESUMEN

PURPOSE: Cervical spine malalignment can develop as a consequence of degenerative disc disease or following spinal surgery. When normal sagittal alignment of the spine is disrupted, further degeneration may occur adjacent to the deformity. The purpose of this study was to investigate changes in lordosis and sagittal alignment in the cervical spine after insertion of supraphysiologic lordotic implants. METHODS: Eight cadaveric cervical spines (Occiput-T1) were tested. The occiput was free to translate horizontally and vertically but constrained from angular rotation. The T1 vertebra was rigidly fixed with a T1 tilt of 23°. Implants with varying degrees of lordosis were inserted starting with single-level constructs (C5-C6), followed by two (C5-C7), and three-level (C4-C7) constructs. Changes in sagittal alignment, Occ-C2 angle, cervical lordosis (C2-7), and segmental lordosis were measured. RESULTS: Increasing cage lordosis led to global increases in cervical lordosis. As implanted segmental lordosis increased, the axial levels compensated by decreasing in lordosis to maintain horizontal gaze. An increase in cage lordosis also corresponded with larger changes in SVA. CONCLUSION: Reciprocal compensation was observed in the axial and sub-axial cervical spine, with the Occ-C2 segment undergoing the largest compensation. Adding more implant lordosis led to larger reciprocal changes and changes in SVA. Implants with supraphysiologic lordosis may allow for additional capabilities in correcting cervical sagittal plane deformity, following further clinical evaluation.


Asunto(s)
Vértebras Cervicales/cirugía , Lordosis/patología , Prótesis e Implantes , Adulto , Anciano , Fenómenos Biomecánicos , Cadáver , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/patología , Femenino , Humanos , Lordosis/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiografía , Rotación , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/patología , Vértebras Torácicas/cirugía
5.
Oper Neurosurg (Hagerstown) ; 13(6): 718-723, 2017 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29186600

RESUMEN

BACKGROUND: The optimum pattern of pedicle screw (PS) fixation during long-segment thoracic fixation has not been determined. OBJECTIVE: To evaluate rod stress and construct stability with minimal, alternating, skipped, and bilateral PS constructs in the iatrogenically destabilized thoracic spine. METHODS: Eight cadaveric thoracic specimens (T3-T12) were initially tested intact to ±5 Nm using a custom 6 degree-of-freedom spine testing apparatus in flexion-extension (FE), lateral bending (LB), and axial rotation. Specimens were instrumented with T4-T10 bilateral PS, with Ponte osteotomies to introduce instability. Rods were bent to fit the PS and then spines were tested with the minimal, alternating, skipped, and bilateral fixation patterns. Range of motion (ROM) was calculated from T4-T10 and segmentally. In addition, strain gauges fixed to the spinal rods measured rod stress under FE and LB. Results were compared using ANOVA and post hoc Holm Sidak tests. RESULTS: All fixation patterns provided significant reductions in ROM with respect to the intact spine. In all motion planes, minimal provided the least amount of rigidity, while bilateral provide the greatest; however, no statistically significant differences were detected in FE. In LB and axial rotation, skipped, alternating, and bilateral were all significantly more rigid than minimal (P < .01). Rod strains were greatest under LB and correlated with overall construct ROM, where bilateral had significantly lower strain than the other patterns (P < .05). CONCLUSION: All constructs effectively decreased thoracic ROM. There was significant improvement in stabilization and decreased rod stress when more fixation points beyond the minimal construct were included.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Fijadores Internos , Tornillos Pediculares , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Vértebras Torácicas/cirugía , Adulto , Biofisica , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular
6.
Surg Neurol Int ; 8: 207, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28966814

RESUMEN

BACKGROUND: In an effort to minimize rod fractures and nonunion in pedicle subtraction osteotomy (PSO) constructs, surgeons have adopted multirod constructs and interbody cages. Anterior column realignment (ACR) with posterior column osteotomies is a minimally invasive alternative to PSO in sagittal balance correction, however, there is a paucity of evidence with respect to rod survival. METHODS: Three-dimensional (3D) finite-element-model of a T12-sacrum spine segment was used to compare a 25° PSO at L3 and an ACR with a posterior column osteotomy and 30° hyperlordotic interbody cage at L3-4. The amount of overall T12-S1 lordosis correction was the same for each condition. Each simulation included cobalt chromium alloy primary rods with: (1) PSO; (2) PSO with an interbody cage (IB) at L2-3 (PSO+IB); (3) PSO with accessory (A) rods and IB at L2-3 (PSO+IB+A); (4) PSO with satellite (S) rods and IB at L2-3 (PSO+IB+2S); (5) ACR; 6) ACR with satellite rods (ACR + 2S). A 400 N follower preload was simulated for each condition. RESULTS: PSO condition had the largest rod stress of 286 MPa in flexion. Adding interbody support reduced the rod stress by 15%. The 4-rod constructs further reduced rod stress, with the satellite rod condition facilitating the largest reduction. The rod stress in the ACR+2S was equivalent to the PSO+2S, with 50% reduction in rod stress. CONCLUSION: The rod stress with an ACR was comparable to a PSO coupled with interbody support. These results suggest an ACR is a viable MIS alternative to a PSO without the need for a large posterior osteotomy.

7.
J Neurosurg Spine ; 26(1): 125-133, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27611508

RESUMEN

OBJECTIVE Proximal junctional kyphosis (PJK) remains problematic following multilevel instrumented spine surgery. Previous biomechanical studies indicate that providing less rigid fixation at the cranial aspect of a long posterior instrumented construct, via transition rods or hooks at the upper instrumented vertebra (UIV), may provide a gradual transition to normal motion and prevent PJK. The purpose of this study was to evaluate the ability of posterior anchored polyethylene tethers to distribute proximal motion segment stiffness in long instrumented spine constructs. METHODS A finite element model of a T7-L5 spine segment was created to evaluate range of motion (ROM), intradiscal pressure, pedicle screw loads, and forces in the posterior ligament complex within and adjacent to the proximal terminus of an instrumented spine construct. Six models were tested: 1) intact spine; 2) bilateral, segmental pedicle screws (PS) at all levels from T-11 through L-5; 3) bilateral pedicle screws from T-12 to L-5 and transverse process hooks (TPH) at T-11 (the UIV); 4) pedicle screws from T-11 to L5 and 1-level tethers from T-10 to T-11 (TE-UIV+1); 5) pedicle screws from T-11 to L-5 and 2-level tethers from T-9 to T-11 (TE-UIV+2); and 6) pedicle screws and 3-level tethers from T-8 to T-11 (TE-UIV+3). RESULTS Proximal-segment range of motion (ROM) for the PS construct increased from 16% at UIV-1 to 91% at UIV. Proximal-segment ROM for the TPH construct increased from 27% at UIV-1 to 92% at UIV. Posterior tether constructs distributed ROM at the UIV and cranial adjacent segments most effectively; ROM for TE-UIV+1 was 14% of the intact model at UIV-1, 76% at UIV, and 98% at UIV+1. ROM for TE-UIV+2 was 10% at UIV-1, 51% at UIV, 69% at UIV+1, and 97% at UIV+2. ROM for TE-UIV+3 was 7% at UIV-1, 33% at UIV, 45% at UIV+1, and 64% at UIV+2. Proximal segment intradiscal pressures, pedicle screw loads, and ligament forces in the posterior ligament complex were progressively reduced with increasing number of posterior tethers used. CONCLUSIONS Finite element analysis of long instrumented spine constructs demonstrated that posterior tethers created a more gradual transition in ROM and adjacent-segment stress from the instrumented to the noninstrumented spine compared with all PS and TPH constructs. Posterior tethers may limit the biomechanical risk factor for PJK; however, further clinical research is needed to evaluate clinical efficacy.


Asunto(s)
Cifosis/fisiopatología , Modelos Biológicos , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Cifosis/cirugía , Ligamentos Longitudinales , Vértebras Lumbares/fisiopatología , Tornillos Pediculares , Presión , Rango del Movimiento Articular , Estrés Fisiológico , Vértebras Torácicas/fisiopatología
8.
Spine (Phila Pa 1976) ; 41 Suppl 8: S44-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26825792

RESUMEN

STUDY DESIGN: Biomechanical study and review of literature on expandable lumbar interbody fusion constructs. OBJECTIVE: To evaluate the biomechanical stability of expandable interbody devices. SUMMARY OF BACKGROUND DATA: Lumbar interbody implants placed from an anterior or lateral approach are desirable due to their large size, providing a stable fusion environment. Posterior implants are typically limited by their access corridor. Expandable footprint transforaminal lumbar interbody fusion (TLIF) interbodies may allow for a minimally invasive TLIF approach with the biomechanical benefits of an anterior lumbar interbody fusion (ALIF)-sized graft; however, this requires experimental investigation. METHODS: Six cadaveric L1-sacrum segments were tested intact with pure moments of  ± 7.5  N m in flexion-extension, lateral bending, and axial rotation. Specimens received at L4-5 either a medial-lateral expandable TLIF cage (MLX-TLIF) or a conventional polyether ether ketone (PEEK) banana-shaped TLIF cage (Conv-TLIF) first. Both were tested with unilateral and bilateral pedicle screw (PS) fixation. Testing was repeated with the alternate cage and fixation. Motion marker arrays were fixed to L4 and L5 to assess range of motion. Results were compared with published data for a PEEK ALIF cage with anterior plate and a PEEK ALIF cage with bilateral PS fixation, tested under the same conditions. RESULTS: The most rigid construct was ALIF with bilateral PS fixation in flexion-extension and axial rotation, whereas MLX with bilateral PS was most rigid in lateral bending. Conv-TLIF with unilateral PS was the least rigid construct. MLX-TLIF with unilateral PS provided similar range of motion to Conv-TLIF with bilateral PS in flexion-extension and lateral bending, and ALIF with anterior plate in lateral bending. CONCLUSION: The MLX-TLIF cage with unilateral PS fixation provided comparable stability to conventional TLIF with bilateral PS fixation and ALIF with anterior plate treatments. The large footprint of the expandable cage may reduce the TLIF supplemental fixation demands and facilitate minimally invasive single-position surgery. If needed, additional stability may be achieved by using bilateral PS. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Vértebras Lumbares/cirugía , Región Lumbosacra/cirugía , Prótesis e Implantes , Fusión Vertebral/instrumentación , Adulto , Fenómenos Biomecánicos , Diseño de Equipo , Humanos , Persona de Mediana Edad , Tornillos Pediculares , Rango del Movimiento Articular , Adulto Joven
9.
Int J Spine Surg ; 9: 53, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26609508

RESUMEN

BACKGROUND: Expandable cages are gaining popularity in anterior reconstruction of the thoracolumbar spine following corpectomy as they can provide adjustable distraction and deformity correction. Rectangular, rather than circular, endcaps provide increased resistance to subsidence by spanning the apophyseal ring; however their impact on construct stability is not known. The objective of this study was to investigate the contribution of expandable corpectomy cage endcap shape (round vs. rectangular) and fixation method (anterior plate vs. posterior pedicle screws) to the stability of an L1 sub-total corpectomy construct. METHODS: Eight fresh-frozen cadaveric specimens (T11-L3) were subjected to multi-directional flexibility testing to 6 N·m with a custom spine simulator. Test conditions were: intact, L1 sub-total corpectomy defect, expandable cage (round endcap) alone, expandable cage (round endcap) with anterior plate, expandable cage (round endcap) with bilateral pedicle screws, expandable cage (rectangular endcap) alone, expandable cage (rectangular endcap) with anterior plate, expandable cage (rectangular endcap) with bilateral pedicle screws. Range-of-motion across T12-L2 was measured with an optoelectronic system. RESULTS: The expandable cage alone with either endcap provided significant stability to the corpectomy defect, reducing motion to intact levels in flexion-extension with both endcap types, and in lateral bending with rectangular endcaps. Round endcaps allowed greater motion than intact in lateral bending, and axial rotation ROM was greater than intact for both endcaps. Supplemental fixation provided the most rigid constructs, although there were no significant differences between instrumentation or endcap types. CONCLUSIONS: These results suggest anterior-only fixation may be adequate when using an expandable cage in a sub-total corpectomy application and choice of endcap type may be driven by other factors such as subsidence resistance.

11.
J Spinal Disord Tech ; 28(4): E181-5, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25905801

RESUMEN

STUDY DESIGN: This is a cadaveric biomechanical study evaluating the biomechanical properties of a novel spinopelvic fixation technique with percutaneous lumbo-sacro-iliac (LSI) screws in an unstable total sacrectomy model. OBJECTIVE: To compare standard posterior dual rod spinopelvic fixation alone with dual rod fixation supplemented with LSI screw fixation. SUMMARY OF BACKGROUND DATA: Primary or metastatic tumors of the sacrum requiring a total sacrectomy can result in spinopelvic instability if inadequate fixation is achieved. Many fixation techniques have been proposed to address this instability. However, to date, an optimal fixation technique has not been established. MATERIALS AND METHODS: Ten fresh-frozen cadaveric spinopelvic specimens were randomized according to bone mineral density (BMD) to either posterior rod fixation (control group) or posterior rod fixation with supplemental LSI screws (LSI group). After fixation, a total sacrectomy of each specimen was performed. Specimens where then potted and axially loaded in a caudal direction. Stiffness, yield load, energy absorbed at yield load, ultimate load, and energy absorbed at ultimate load were computed. A Student t test was used for statistical analysis with significance set at P<0.05. RESULTS: The average age and BMD were not significantly different between the control and LSI groups (age: P=0.255; BMD: P=0.810). After normalizing for BMD, there were no significant differences detected for any of the biomechanical parameters measured between the 2 fixation techniques: stiffness (P=0.857), yield load (P=0.219), energy at yield load (P=0.293), ultimate load (P=0.407), and energy at ultimate load (P=0.773). However, both fixation techniques were able to withstand physiological loads. CONCLUSIONS: Our study did not demonstrate any biomechanical advantage for supplemental LSI screw fixation in our axial loading model. However, given the theoretical advantage of this percutaneous technique, further studies are warranted that take into account forward bending and sagittal stability.


Asunto(s)
Tornillos Óseos/efectos adversos , Ilion/cirugía , Región Lumbosacra/cirugía , Dispositivos de Fijación Ortopédica/efectos adversos , Procedimientos Ortopédicos/métodos , Sacro/cirugía , Adulto , Anciano , Fenómenos Biomecánicos , Densidad Ósea , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fusión Vertebral/métodos
12.
Eur Spine J ; 24 Suppl 3: 420-6, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25772093

RESUMEN

PURPOSE: Restoring sagittal alignment is an important factor in the treatment of spinal deformities. Recent investigations have determined that releasing the anterior longitudinal ligament (ALL) and placing hyperlordotic cages can increase lordosis, while minimizing need for 3 column osteotomies. The influences of parameters such as cage height and angle have not been determined. Finite element analysis was employed to assess the extent of lordosis achievable after placement of different sized lordotic cages. METHODS: A 3-dimensional model of a L3-4 segment was used. Disc distraction was simulated by inserting interbody cages mid-body in the disc space. Analyses were performed in the following conditions: (1) intact, (2) ALL release, (3) ALL release + facetectomy, and (4) ALL release + posterior column osteotomy. Changes in segmental lordosis, disc height, foraminal height, and foraminal area were measured. RESULTS: After ALL resection and insertion of hyperlordotic cages, lordosis was increased in all cases. The lordosis achieved by the shorter cages was less due to posterior disc height maintained by the facet joints. A facetectomy increased segmental lordosis, but led to contact between the spinous processes. For some configurations, a posterior column osteotomy was required if the end goal was to match cage angle to intradiscal angle. CONCLUSION: Increased segmental lumbar lordosis is achievable with hyperlordotic cages after ALL resection. Increased cage height tended to increase the amount of lordosis achieved, although in some cases additional posterior bone resection was required to maximize lordosis. Further studies are needed to evaluate the impact on regional lumbar lordosis.


Asunto(s)
Ligamentos Longitudinales/cirugía , Lordosis/cirugía , Fusión Vertebral/métodos , Análisis de Elementos Finitos , Humanos , Disco Intervertebral/patología , Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Dispositivos de Fijación Ortopédica
13.
Spine (Phila Pa 1976) ; 39(19): E1138-46, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-24979274

RESUMEN

STUDY DESIGN: In vitro cadaveric biomechanical study of lateral interbody cages and supplemental fixation in a degenerative spondylolisthesis (DS) model. OBJECTIVE: To investigate changes in shear and flexion-extension stability of lateral interbody fusion constructs. SUMMARY OF BACKGROUND DATA: Instability associated with DS may increase postoperative treatment complications. Several groups have investigated DS in cadaveric spines. Extreme lateral interbody fusion (XLIF) cages with supplemental fixation have not previously been examined using a DS model. METHODS: Seven human cadaveric L4-L5 motion segments were evaluated using flexion-extension moments to ±7.5 N·m and anterior-posterior (A-P) shear loading of 150 N with a static axial compressive load of 300 N. Conditions were: (1) intact segment, (2) DS simulation with facet resection and lateral discectomy, (3) standalone XLIF cage, (4) XLIF cage with (1) lateral plate, (2) lateral plate and unilateral pedicle screws contralateral to the plate (PS), (3) unilateral PS, (4) bilateral PS, (5) spinous process plate, and (6) lateral plate and spinous process plate. Flexion-extension range of motion (ROM) data were compared between conditions and with results from a previous study without DS simulation. A-P shear displacements were compared between conditions. RESULTS: Flexion-extension ROM after DS destabilization increased significantly by 181% of intact ROM. With the XLIF cage alone, ROM decreased to 77% of intact. All conditions were less stable than corresponding conditions with intact posterior elements except those including the spinous process plate. Under shear loading, A-P displacement with the XLIF cage alone increased by 2.2 times intact. Bilateral PS provided the largest reduction of A-P displacement, whereas the spinous process plate alone provided the least. CONCLUSION: This is the first in vitro shear load testing of XLIF cages with supplemental fixation in a cadaveric DS model. The variability in sagittal plane construct stability, including significantly increased flexion-extension ROM found with most fixation conditions including bilateral PS may explain some clinical treatment complications in DS with residual instability. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Discectomía/instrumentación , Fijadores Internos , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Espondilolistesis/cirugía , Adulto , Anciano , Placas Óseas , Tornillos Óseos , Fuerza Compresiva , Humanos , Inestabilidad de la Articulación , Persona de Mediana Edad , Resistencia al Corte , Soporte de Peso
14.
J Clin Neurosci ; 21(9): 1632-6, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24831343

RESUMEN

Corpectomy cages with rectangular endcaps utilize the stronger peripheral part of the endplate, potentially decreasing subsidence risk. The authors evaluated cage subsidence during cyclic biomechanical testing, comparing rectangular versus round endcaps. Fourteen cadaveric spinal segments (T12-L2) were dissected and potted at T12 and L2, then assigned to a rectangular (n=7) or round (n=7) endcap group. An L1 corpectomy was performed and under uniform conditions a cage/plate construct was cyclically tested in a servo-hydraulic frame with increasing load magnitude. Testing was terminated if the test machine actuator displacement exceeded 6mm, or the specimen completed cyclic loading at 2400 N. Number of cycles, compressive force and force-cycles product at test completion were all greater in the rectangular endcap group compared with the round endcap group (cycles: 3027 versus 2092 cycles; force: 1943 N versus 1533 N; force-cycles product: 6162kN·cycles versus 3973 kN·cycles), however these differences were not statistically significant (p ⩾ 0.076). After normalizing for individual specimen bone mineral density, the same measures increased to a greater extent with the rectangular endcaps (cycles: 3014 versus 1855 cycles; force: 1944 N versus 1444 N; force-cycles product: 6040 kN·cycles versus 2980 kN·cycles), and all differences were significant (p⩽0.030). The rectangular endcap expandable corpectomy cage displayed increased resistance to subsidence over the round endcap cage under cyclic loading as demonstrated by the larger number of cycles, maximum load and force-cycles product at test completion. This suggests rectangular endcaps will be less susceptible to subsidence than the round endcap design.


Asunto(s)
Fijadores Internos , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Densidad Ósea , Fluoroscopía , Humanos , Vértebras Lumbares/fisiología , Fenómenos Mecánicos , Diseño de Prótesis
15.
J Neurosurg Spine ; 20(3): 291-7, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24405464

RESUMEN

OBJECT: Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro stability of the interbody cage with a combination of lateral and spinous process plate fixation and compare this method to the established bilateral pedicle screw fixation technique. METHODS: Ten L1-5 specimens were evaluated using multidirectional nondestructive moments (± 7.5 N · m), with a custom 6 degrees-of-freedom spine simulator. Intervertebral motions (ROM) were measured optoelectronically. Each spine was evaluated under the following conditions at the L3-4 level: intact; interbody cage alone (stand-alone); cage supplemented with lateral plate; cage supplemented with ipsilateral pedicle screws; cage supplemented with bilateral pedicle screws; cage supplemented with spinous process plate; and cage supplemented with a combination of lateral plate and spinous process plate. Intervertebral rotations were calculated, and ROM data were normalized to the intact ROM data. RESULTS: The stand-alone laterally inserted interbody cage significantly reduced ROM with respect to the intact state in flexion-extension (31.6% intact ROM, p < 0.001), lateral bending (32.5%, p < 0.001), and axial rotation (69.4%, p = 0.002). Compared with the stand-alone condition, addition of a lateral plate to the interbody cage did not significantly alter the ROM in flexion-extension (p = 0.904); however, it was significantly decreased in lateral bending and axial rotation (p < 0.001). The cage supplemented with a lateral plate was not statistically different from bilateral pedicle screws in lateral bending (p = 0.579). Supplemental fixation using a spinous process plate was not significantly different from bilateral pedicle screws in flexion-extension (p = 0.476). The combination of lateral plate and spinous process plate was not statistically different from the cage supplemented with bilateral pedicle screws in all the loading modes (p ≥ 0.365). CONCLUSIONS: A combination of lateral and spinous process plate fixation to supplement a laterally inserted interbody cage helps achieve rigidity in all motion planes similar to that achieved with bilateral pedicle screws.


Asunto(s)
Placas Óseas , Tornillos Óseos , Vértebras Lumbares/fisiología , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Adulto , Anciano , Fenómenos Biomecánicos , Cadáver , Discectomía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Fusión Vertebral/instrumentación
16.
Spine (Phila Pa 1976) ; 39(1): 33-8, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24108277

RESUMEN

STUDY DESIGN: Anatomic studies have demonstrated that nerves and blood vessels have excursion with extremity range of motion. We have measured femoral nerve excursion with the lateral lumbar transpsoas interbody fusion (LLIF) procedure with changes in table flexion and ipsilateral hip flexion on both sides of 5 cadavers. OBJECTIVE: To determine the effect of hip range of motion on femoral nerve strain near the L4-L5 disc space because it pertains to the LLIF procedure. SUMMARY OF BACKGROUND DATA: Postoperative thigh symptoms are common after the LLIF procedure. Although nerve strain in general has been shown to impair function, it has not been tested specifically with LLIF. METHODS: Five cadavers were placed in the lateral position as though undergoing the L4-L5 LLIF procedure. Radiographical markers were implanted into the femoral nerve. Lateral and anteroposterior fluoroscopic images were recorded with 0° initial table flexion and the hip at 0, 20, 40, and 60° flexion. The table was flexed to 40°, and the process repeated. Examination was repeated on the contralateral side and nerve strain and excursion were calculated. RESULTS: Table flexion results in preloading the femoral nerve when approaching L4-L5. Nerve strain was highest with the table flexed to 40° and the hip at 0° (average, 6%-7%). Strain in the femoral nerve decreased with increasing hip flexion for both table flexion angles. Anterior displacement of the nerve by approximately 1.5 mm was noted at 40° table flexion compared with 0°. CONCLUSION: Strain values with table flexion of 40° approached those associated with reduced neural blood flow in animal studies. Table flexion should be minimized to the extent possible when performing L4-L5 LLIF. Additionally, hip flexion to 60° can neutralize the neural strain that occurs with aggressive table flexion. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Nervio Femoral/cirugía , Vértebras Lumbares/cirugía , Rango del Movimiento Articular , Fusión Vertebral/métodos , Anciano , Femenino , Nervio Femoral/diagnóstico por imagen , Fluoroscopía , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad
17.
Spine J ; 13(1): 77-84, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23295035

RESUMEN

BACKGROUND CONTEXT: Stand-alone interbody cages with integrated screws potentially provide a biomechanically stable solution for anterior lumbar interbody fusion (ALIF) that alleviates the need for additional exposure for supplemental fixation, thereby reducing the chance of additional complications and morbidity. PURPOSE: To compare the stability of a stand-alone anterior interbody fusion system with integrated fixation screws against traditional supplemental fixation methods and to evaluate the difference between three and four fixation screws in the stand-alone cage. STUDY DESIGN: In vitro cadaveric biomechanical study. METHODS: Eight cadaveric lumbar spines (L2-sacrum) were tested using a flexibility protocol consisting of three cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The conditions evaluated were intact spine; polyether-ether-ketone cage (zero integrated screws) at L4-L5; cage (zero screws)+bilateral pedicle screws (PS); cage (three screws); cage (four screws); cage (zero screws)+anterior plate; and cage (three screws)+spinous process plate. Motion at the index level was assessed using an optoelectronic system. RESULTS: The cage without integrated screws reduced the motion in flexion-extension and lateral bending (p<.001) compared with that in the intact spine. In axial rotation, mean range of motion (ROM) was 8% greater than in intact spine (p>.962). The addition of three integrated screws reduced ROM significantly compared with the cage without screws in all motion planes (p<.001). A fourth screw had no statistically significant effect on the ROM, although there was a trend toward less motion with four screws compared with three. In flexion-extension, the cage with three integrated screws and the spinous process plate was the most rigid condition. There was no significant difference from the bilateral PS (p=.537); however, this was more rigid than all other conditions (p<.024). The most stable condition in lateral bending and axial rotation was the cage with bilateral PS. In lateral bending, the cage (three or four screws) was not significantly different from the cage with anterior plate or the cage (three screws) with spinous process plate fixation; however, only the latter condition was statistically comparable with bilateral PS. In axial rotation, there were no significant differences between the conditions that included integrated screws or supplemental fixation (p>.081). CONCLUSIONS: Biomechanical testing revealed that the stand-alone cage with integrated screws provides more immediate stability than a cage alone and provides equivalent stability to ALIF constructs with supplemental fixation in lateral bending and axial rotation. Additional flexion-extension rigidity of the anterior cage maybe realized by the addition of a spinous process plate that was found to be as stable as supplemental bilateral PS.


Asunto(s)
Cetonas/uso terapéutico , Vértebras Lumbares/fisiología , Vértebras Lumbares/cirugía , Polietilenglicoles/uso terapéutico , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Benzofenonas , Materiales Biocompatibles/uso terapéutico , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Humanos , Fijadores Internos , Vértebras Lumbares/diagnóstico por imagen , Movimiento/fisiología , Polímeros , Radiografía , Rango del Movimiento Articular/fisiología
18.
ScientificWorldJournal ; 2012: 381814, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23213284

RESUMEN

This study investigates the biomechanical stability of a large interbody spacer inserted by a lateral approach and compares the biomechanical differences with the more conventional transforaminal interbody fusion (TLIF), with and without supplemental pedicle screw (PS) fixation. Twenty-four L2-L3 functional spinal units (FSUs) were tested with three interbody cage options: (i) 18 mm XLIF cage, (ii) 26 mm XLIF cage, and (iii) 11 mm TLIF cage. Each spacer was tested without supplemental fixation, and with unilateral and bilateral PS fixation. Specimens were subjected to multidirectional nondestructive flexibility tests to 7.5 N·m. The range of motion (ROM) differences were first examined within the same group (per cage) using repeated-measures ANOVA, and then compared between cage groups. The 26 mm XLIF cage provided greater stability than the 18 mm XLIF cage with unilateral PS and 11 mm TLIF cage with bilateral PS. The 18 mm XLIF cage with unilateral PS provided greater stability than the 11 mm TLIF cage with bilateral PS. This study suggests that wider lateral spacers are biomechanically stable and offer the option to be used with less or even no supplemental fixation for interbody lumbar fusion.


Asunto(s)
Placas Óseas , Tornillos Óseos , Vértebras Lumbares/fisiopatología , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Adulto , Anciano , Fuerza Compresiva , Módulo de Elasticidad , Análisis de Falla de Equipo , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Rango del Movimiento Articular , Rotación , Resistencia a la Tracción , Resultado del Tratamiento , Soporte de Peso , Adulto Joven
19.
J Neurosurg Spine ; 17(5): 476-85, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22938554

RESUMEN

OBJECT: In the surgical treatment of spinal deformities, the importance of restoring lumbar lordosis is well recognized. Smith-Petersen osteotomies (SPOs) yield approximately 10° of lordosis per level, whereas pedicle subtraction osteotomies result in as much as 30° increased lumbar lordosis. Recently, selective release of the anterior longitudinal ligament (ALL) and placement of lordotic interbody grafts using the minimally invasive lateral retroperitoneal transpsoas approach (XLIF) has been performed as an attempt to increase lumbar lordosis while avoiding the morbidity of osteotomy. The objective of the present study was to measure the effect of the selective release of the ALL and varying degrees of lordotic implants placed using the XLIF approach on segmental lumbar lordosis in cadaveric specimens between L-1 and L-5. METHODS: Nine adult fresh-frozen cadaveric specimens were placed in the lateral decubitus position. Lateral radiographs were obtained at baseline and after 4 interventions at each level as follows: 1) placement of a standard 10° lordotic cage, 2) ALL release and placement of a 10° lordotic cage, 3) ALL release and placement of a 20° lordotic cage, and 4) ALL release and placement of a 30° lordotic cage. All four cages were implanted sequentially at each interbody level between L-1 and L-5. Before and after each intervention, segmental lumbar lordosis was measured in all specimens at each interbody level between L-1 and L-5 using the Cobb method on lateral radiography. RESULTS: The mean baseline segmental lordotic angles at L1-2, L2-3, L3-4, and L4-5 were -3.8°, 3.8°, 7.8°, and 22.6°, respectively. The mean lumbar lordosis was 29.4°. Compared with baseline, the mean postimplantation increase in segmental lordosis in all levels combined was 0.9° in Intervention 1 (10° cage without ALL release); 4.1° in Intervention 2 (ALL release with 10° cage); 9.5° in Intervention 3 (ALL release with 20° cage); and 11.6° in Intervention 4 (ALL release with 30° cage). Foraminal height in the same sequence of conditions increased by 6.3%, 4.6%, 8.8% and 10.4%, respectively, while central disc height increased by 16.1%, 22.3%, 52.0% and 66.7%, respectively. Following ALL release and placement of lordotic cages at all 4 lumbar levels, the average global lumbar lordosis increase from preoperative lordosis was 3.2° using 10° cages, 12.0° using 20° cages, and 20.3° using 30° cages. Global lumbar lordosis with the cages at 4 levels exhibited a negative correlation with preoperative global lordosis (10°, R = -0.756; 20°, -0.730; and 30°, R = -0.437). CONCLUSIONS: Combined ALL release and placement of increasingly lordotic lateral interbody cages leads to progressive gains in segmental lordosis in the lumbar spine. Mean global lumbar lordosis similarly increased with increasingly lordotic cages, although the effect with a single cage could not be evaluated. Greater global lordosis was achieved with smaller preoperative lordosis. The mean maximum increase in segmental lordosis of 11.6° followed ALL release and placement of the 30° cage.


Asunto(s)
Fijadores Internos , Ligamentos Longitudinales/cirugía , Lordosis , Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fusión Vertebral/métodos , Anciano , Anciano de 80 o más Años , Cadáver , Humanos , Ligamentos Longitudinales/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Radiografía , Fusión Vertebral/instrumentación
20.
J Neurosurg Spine ; 16(6): 585-93, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22519928

RESUMEN

OBJECT: Traditional posterior pedicle screw fixation is well established as the standard for spinal stabilization following posterior or posterolateral lumbar fusion. In patients with lumbar spinal stenosis requiring segmental posterior instrumented fusion and decompression, interlaminar lumbar instrumented fusion (ILIF) is a potentially less invasive alternative with reduced morbidity and includes direct decompression assisted by an interlaminar allograft spacer stabilized by a spinous process plate. To date, there has been no biomechanical study on this technique. In the present study the biomechanical properties of the ILIF construct were evaluated using an in vitro cadaveric biomechanical analysis, and the results are presented in comparison with other posterior fixation techniques. METHODS: Eight L1-5 cadaveric specimens were subjected to nondestructive multidirectional testing. After testing the intact spine, the following conditions were evaluated at L3-4: bilateral pedicle screws, bilateral laminotomy, ILIF, partial laminectomy, partial laminectomy plus unilateral pedicle screws, and partial laminectomy plus bilateral screws. Intervertebral motions were measured at the index and adjacent levels. RESULTS: Bilateral pedicle screws without any destabilization provided the most rigid construct. In flexion and extension, ILIF resulted in significantly less motion than the intact spine (p < 0.05) and no significant difference from the laminectomy with bilateral pedicle screws (p = 0.76). In lateral bending, there was no statistical difference between ILIF and laminectomy with unilateral pedicle screws (p = 0.11); however, the bilateral screw constructs were more rigid (p < 0.05). Under axial rotation, ILIF was not statistically different from laminectomy with unilateral or bilateral pedicle screws or from the intact spine (p > 0.05). Intervertebral motions adjacent to ILIF were typically lower than those adjacent to laminectomy with bilateral pedicle screws. CONCLUSIONS: Stability of the ILIF construct was not statistically different from bilateral pedicle screw fixation following laminectomy in the flexion and extension and axial rotation directions, while adjacent segment motions were decreased. The ILIF construct may allow surgeons to perform a minimally invasive, single-approach posterior decompression and instrumented fusion without the added morbidity of traditional pedicle screw fixation and posterolateral fusion.


Asunto(s)
Trasplante Óseo/métodos , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Estenosis Espinal/cirugía , Fenómenos Biomecánicos , Tornillos Óseos , Trasplante Óseo/instrumentación , Humanos , Fijadores Internos , Persona de Mediana Edad , Rango del Movimiento Articular , Fusión Vertebral/instrumentación , Trasplante Autólogo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...