Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 24(1): 58, 2022 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-36352454

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of contrast agent (ferumoxytol vs. gadolinium) may influence 4D Flow CMR accuracy. Thus, we investigated the accuracy of 4D Flow CMR measurements compared to gold standard 2D flow phase contrast (PC) measurements in ferumoxytol vs. gadolinium-enhanced CMR of small CHD patients with shunt lesions. METHODS: This was a retrospective study consisting of CMR studies from complex CHD patients less than 20 kg who had ferumoxytol or gadolinium-enhanced 4D Flow and standard two-dimensional phase contrast (2D-PC) flow collected. 4D Flow clinical software (Arterys) was used to measure flow in great vessels, systemic veins, and pulmonary veins. 4D Flow accuracy was defined as percent difference or correlation against conventional measurements (2D-PC) from the same vessels. Subgroup analysis was performed on two-ventricular vs single-ventricular CHD, arterial vs venous flow, as well as low flows (defined as < 1.5 L/min) in 1V CHD. RESULTS: Twenty-one ferumoxytol-enhanced and 23 gadolinium-enhanced CMR studies were included, with no difference in age (2.1 ± 1.6 vs. 2.3 ± 1.9 years, p = 0.70), patient body surface area (0.50 ± 0.2 vs. 0.52 ± 0.2 m2, p = 0.67), or vessel diameter (11.4 ± 5.2 vs. 12.4 ± 5.6 mm, p = 0.22). Ten CMR studies with single ventricular CHD were included. Overall, ferumoxytol-enhanced 4D flow CMR measurements demonstrated less percent difference to 2D-PC when compared to gadolinium-enhanced 4D Flow CMR studies. In subgroup analyses of arterial vs. venous flows (high velocity vs. low velocity) and low flow in single ventricle CHD, ferumoxytol-enhanced 4D Flow CMR measurements had stronger correlation to 2D-PC CMR. The contrast-to-noise ratio (CNR) in ferumoxytol-enhanced studies was higher than the CNR in gadolinium-enhanced studies. CONCLUSIONS: Ferumoxytol-enhanced 4D Flow CMR has improved accuracy when compared to gadolinium 4D Flow CMR, particularly for infants with small vessels in CHD.


Asunto(s)
Gadolinio , Cardiopatías Congénitas , Niño , Lactante , Humanos , Óxido Ferrosoférrico , Estudios Retrospectivos , Velocidad del Flujo Sanguíneo , Valor Predictivo de las Pruebas , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Ventrículos Cardíacos , Espectroscopía de Resonancia Magnética , Reproducibilidad de los Resultados
2.
Cardiol Young ; 32(6): 855-860, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34986917

RESUMEN

OBJECTIVE: To evaluate the association of systolic blood pressure percentile, race, and body mass index with left ventricular hypertrophy on electrocardiogram and echocardiogram to define populations at risk. STUDY DESIGN: This is a retrospective cross-sectional study design utilising a data analytics tool (Tableau) combining electrocardiogram and echocardiogram databases from 2003 to 2020. Customized queries identified patients aged 2-18 years who had an outpatient electrocardiogram and echocardiogram on the same date with available systolic blood pressure and body measurements. Cases with CHD, cardiomyopathy, or arrhythmia diagnoses were excluded. Echocardiograms with left ventricle mass (indexed to height2.7) were included. The main outcome was left ventricular hypertrophy on echocardiogram defined as Left ventricle mass index greater than the 95th percentile for age. RESULTS: In a cohort of 13,539 patients, 6.7% of studies had left ventricular hypertrophy on echocardiogram. Systolic blood pressure percentile >90% has a sensitivity of 35% and specificity of 82% for left ventricular hypertrophy on echocardiogram. Left ventricular hypertrophy on electrocardiogram was a poor predictor of left ventricular hypertrophy on echocardiogram (9% sensitivity and 92% specificity). African American race (OR 1.31, 95% CI = 1.10, 1.56, p = 0.002), systolic blood pressure percentile >95% (OR = 1.60, 95% CI = 1.34, 1.93, p < 0.001), and higher body mass index (OR = 7.22, 95% CI = 6.23, 8.36, p < 0.001) were independently associated with left ventricular hypertrophy on echocardiogram. CONCLUSIONS: African American race, obesity, and hypertension on outpatient blood pressure measurements are independent risk factors for left ventricular hypertrophy in children. Electrocardiogram has little utility in the screening for left ventricular hypertrophy.


Asunto(s)
Hipertensión , Hipertrofia Ventricular Izquierda , Presión Sanguínea/fisiología , Índice de Masa Corporal , Niño , Estudios Transversales , Humanos , Hipertensión/etiología , Hipertrofia Ventricular Izquierda/etiología , Estudios Retrospectivos
3.
Lancet Child Adolesc Health ; 5(7): 483-490, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34051889

RESUMEN

BACKGROUND: Little is known about geographical variation in infant mortality due to congenital heart disease (CHD) and the social determinants of health that might mediate such variation. We aimed to examine US county-level estimates of infant mortality due to CHD to understand geographical patterns and factors that might influence variation in mortality. METHODS: This US population-based cohort study used linked livebirth-infant death cohort files from the US National Center for Health Statistics from Jan 1, 2006, to Dec 31, 2015. All deaths attributable to congenital heart disease in infants in a given year were included. We used hierarchical Bayesian models to estimate rates of infant mortality due to congenital heart disease for all US counties. We mapped model-based estimates to explore geographical patterns. Covariates included infant sex, gestational age, maternal race and ethnicity, percentage of the county population below the poverty level, and proximity of the county to a US News & World Report 2015 top-50 ranked paediatric cardiac centre. FINDINGS: From 2006 to 2015, 40 847 089 livebirths occurred, of which there were 13 988 infant deaths attributed to congenital heart disease, with an unadjusted infant mortality rate due to CHD of 0·34 per 1000 livebirths (95% CI 0·34-0·35). Kentucky and Mississippi had the greatest proportions of counties with a predicted rate of infant mortality due to CHD above the 95th percentile. All counties in Connecticut, Massachusetts, and Rhode Island had a predicted rate below the fifth percentile. In the model, lower mortality risk correlated with closer proximity to a top-50 ranked paediatric cardiac centre (odds ratio [OR] 0·890, 95% credible interval [CrI] 0·840-0·942), whereas higher mortality risk correlated with higher levels of poverty (OR 1·181, 95% CrI 1·125-1·239). INTERPRETATION: Substantial geographical variation exists in infant mortality due to CHD in the USA, highlighting the potential importance of bolstering care delivery for infants from economically deprived communities and areas remote from top-performing paediatric cardiac centres. FUNDING: None.


Asunto(s)
Cardiopatías Congénitas/mortalidad , Estudios de Cohortes , Demografía , Femenino , Humanos , Lactante , Mortalidad Infantil , Recién Nacido , Masculino , Vigilancia de la Población , Estudios Retrospectivos , Estados Unidos/epidemiología
4.
Cardiol Young ; 27(5): 993-995, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28260542

RESUMEN

Infants of diabetic mothers are at risk for transient hypertrophic cardiomyopathy. These infants are typically asymptomatic, but may develop signs of poor cardiac output from left ventricular outflow tract obstruction. This case illustrates the successful use of extracorporeal membrane oxygenation to support cardiac output in an infant of a diabetic mother with outflow tract obstruction until hypertrophy improved.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/terapia , Oxigenación por Membrana Extracorpórea , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología , Adulto , Gasto Cardíaco , Diabetes Mellitus , Ecocardiografía , Femenino , Humanos , Recién Nacido , Masculino , Madres , Embarazo , Embarazo en Diabéticas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...