Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
In Vivo ; 38(4): 1712-1718, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38936930

RESUMEN

BACKGROUND/AIM: Intensity-modulated radiation therapy can deliver a highly conformal dose to a target while minimizing the dose to the organs at risk (OARs). Delineating the contours of OARs is time-consuming, and various automatic contouring software programs have been employed to reduce the delineation time. However, some software operations are manual, and further reduction in time is possible. This study aimed to automate running atlas-based auto-segmentation (ABAS) and software operations using a scripting function, thereby reducing work time. MATERIALS AND METHODS: Dice coefficient and Hausdorff distance were used to determine geometric accuracy. The manual delineation, automatic delineation, and modification times were measured. While modifying the contours, the degree of subjective correction was rated on a four-point scale. RESULTS: The model exhibited generally good geometric accuracy. However, some OARs, such as the chiasm, optic nerve, retina, lens, and brain require improvement. The average contour delineation time was reduced from 57 to 29 min (p<0.05). The subjective revision degree results indicated that all OARs required minor modifications; only the submandibular gland, thyroid, and esophagus were rated as modified from scratch. CONCLUSION: The ABAS model and scripted automation in head and neck cancer reduced the work time and software operations. The time can be further reduced by improving contour accuracy.


Asunto(s)
Neoplasias de Cabeza y Cuello , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Programas Informáticos , Humanos , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Dosificación Radioterapéutica , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
2.
J Appl Clin Med Phys ; : e14408, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38863310

RESUMEN

PURPOSE: The study aimed to investigate the optimal isodose line (IDL) in linear accelerator-based stereotactic radiotherapy for single brain metastasis, using HyperArc. We compared the dosimetric parameters for target and normal brain tissue among six plans with different IDLs. METHODS: This study included 30 patients with single brain metastasis. We retrospectively generated six plans for each tumor with different IDLs (80%, 70%, 60%, 50%, 40%, and 33%) using HyperArc. All treatment plans were normalized to the prescription dose of 35 Gy in five fractions which was covered by 95% of the planning target volume (PTV), defined by adding a 1.0 mm margin to the gross tumor volume (GTV). The dosimetric parameters were compared among the six plans. RESULTS: For GTV > 0.1 cm3, the ratio of brain-GTV volumes receiving 25 Gy to PTV (V25Gy/PTV) was significantly lower at IDL 40%-70% than at IDL 80% and 33% (p < 0.01, retrospectively). For GTV < 0.1 cm3, V25Gy/PTV decreased continuously as IDL decreased. The values of D99% and D80% for GTV increased with decreasing IDL. An IDL of 50% or less was required to achieve D99% of greater than 43 Gy and D80% of greater than 50 Gy. The mean values of D99% and D80% for IDL 50% were 44.3 and 51.9 Gy. CONCLUSION: The optimal IDL is 40%-50% for GTV > 0.1 cm3. These lower IDLs could increase D99% and D80% of GTV while lowering V25Gy of normal brain tissue, which may help reduce the risk of radiation necrosis and improve local control.

3.
J Appl Clin Med Phys ; : e14413, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38923786

RESUMEN

PURPOSE: This study aimed to find descriptors that correlates with normal brain dose to determine the feasibility of performing fractionated stereotactic radiosurgery (SRS) for multiple brain metastases (BMs) using five linac machines. METHODS: Thirty-two patients with 1-30 BMs were enrolled. Treatment plans were created using TrueBeam, Novalis Tx, TrueBeam Edge, Halcyon, and Tomotherapy linacs. The sum of all planning target volumes (PTVs) was defined as PTVall, and the brain region excluding PTVall was defined as normal brain. The total surface area (TSA) of the PTV was calculated from the sum of the surface areas of the equivalent spheres for each PTV. Volumes receiving more than 5, 12, and 18 Gy (V5Gy, V12Gy, and V18Gy, respectively) were used for evaluation of normal brain dose. Correlations between normal brain dose and each tumor characteristic (number, PTVall, and TSA) were investigated using the Spearman rank correlation coefficient. RESULTS: Correlations between each characteristic and normal brain dose were statistically significant (p < 0.05) across all machines. The correlation coefficients between each characteristic and V18Gy for the five machines were as follows: tumor number, 0.39-0.60; PTVall, 0.79-0.93; TSA, 0.93-0.99. The fit equations between TSA and V18Gy exhibited high coefficients of determination, ranging from 0.92 to 0.99 across five machines. CONCLUSION: This study devised fractionated SRS plans using for 1-30 BMs across five linac machines to find descriptors for determining SRS feasibility based on normal brain dose. TSA proved to be a promising descriptor of SRS feasibility for treating multiple BMs.

4.
Br J Radiol ; 97(1158): 1162-1168, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38648776

RESUMEN

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (gyroscope respiratory training system [GRTS]) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing expiratory breath-hold radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.0%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 96.1% for free breathing and 88.2% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portable, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.


Asunto(s)
Estudios de Factibilidad , Humanos , Reproducibilidad de los Resultados , Masculino , Adulto , Fantasmas de Imagen , Femenino , Contencion de la Respiración , Ejercicios Respiratorios/instrumentación , Ejercicios Respiratorios/métodos , Persona de Mediana Edad , Respiración , Diseño de Equipo
5.
Phys Eng Sci Med ; 47(2): 597-609, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38353926

RESUMEN

In linear accelerator-based stereotactic irradiation (STI) for brain metastasis, cone-beam computed tomography (CBCT) image quality is essential for ensuring precise patient setup and tumor localization. However, CBCT images may be degraded by the deviation of the CBCT isocenter from the brain center. This study aims to investigate the effects of the distance from the brain center to the CBCT isocenter (DBI) on the image quality in STI. An anthropomorphic phantom was scanned with varying DBI in right, anterior, superior, and inferior directions. Thirty patients undergoing STI were prospectively recruited. Objective metrics, utilizing regions of interest included contrast-to-noise ratio (CNR) at the centrum semiovale, lateral ventricle, and basal ganglia levels, gray and white matter noise at the basal ganglia level, artifact index (AI), and nonuniformity (NU). Two radiation oncologists assessed subjective metrics. In this phantom study, objective measures indicated a degradation in image quality for non-zero DBI. In this patient study, there were significant correlations between the CNR at the centrum semiovale and lateral ventricle levels (rs = - 0.79 and - 0.77, respectively), gray matter noise (rs = 0.52), AI (rs = 0.72), and NU (rs = 0.91) and DBI. However, no significant correlations were observed between the CNR at the basal ganglia level, white matter noise, and subjective metrics and DBI (rs < ± 0.3). Our results demonstrate the effects of DBI on contrast, noise, artifacts in the posterior fossa, and uniformity of CBCT images in STI. Aligning the CBCT isocenter with the brain center can aid in improving image quality.


Asunto(s)
Encéfalo , Tomografía Computarizada de Haz Cónico , Fantasmas de Imagen , Radiocirugia , Humanos , Encéfalo/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Anciano , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador , Adulto , Artefactos
6.
J Radiat Res ; 64(6): 940-947, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37839063

RESUMEN

To explore predictors of the histopathological response to preoperative chemoradiotherapy (CRT) in patients with pancreatic cancer (PC) using dual-energy computed tomography-reconstructed images. This retrospective study divided 40 patients who had undergone preoperative CRT (50-60 Gy in 25 fractions) followed by surgical resection into two groups: the response group (Grades II, III and IV, evaluated from surgical specimens) and the nonresponse group (Grades Ia and Ib). The computed tomography number [in Hounsfield units (HUs)] and iodine concentration (IC) were measured at the locations of the aorta, PC and pancreatic parenchyma (PP) in the contrast-enhanced 4D dual-energy computed tomography images. Logistic regression analysis was performed to identify predictors of histopathological response. Univariate analysis did not reveal a significant relation between any parameter and patient characteristics or dosimetric parameters of the treatment plan. The HU and IC values in PP and the differences in HU and IC between the PP and PC (ΔHU and ΔIC, respectively) were significant predictors for distinguishing the response (n = 24) and nonresponse (n = 16) groups (P < 0.05). The IC in PP and ΔIC had a higher area under curve values [0.797 (95% confidence interval, 0.659-0.935) and 0.789 (0.650-0.928), respectively] than HU in PP and ΔHU [0.734 (0.580-0.889) and 0.721 (0.562-0.881), respectively]. The IC value could potentially be used for predicting the histopathological response in patients who have undergone preoperative CRT.


Asunto(s)
Yodo , Neoplasias Pancreáticas , Humanos , Estudios Retrospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/terapia , Quimioradioterapia/métodos , Neoplasias Pancreáticas
7.
Front Immunol ; 14: 1234747, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37545505

RESUMEN

Rap1-GTPase activates integrins and plays an indispensable role in lymphocyte trafficking, but the importance of Rap1 inactivation in this process remains unknown. Here we identified the Rap1-inactivating proteins Rasa3 and Sipa1 as critical regulators of lymphocyte trafficking. The loss of Rasa3 and Sipa1 in T cells induced spontaneous Rap1 activation and adhesion. As a consequence, T cells deficient in Rasa3 and Sipa1 were trapped in the lung due to firm attachment to capillary beds, while administration of LFA1 antibodies or loss of talin1 or Rap1 rescued lung sequestration. Unexpectedly, mutant T cells exhibited normal extravasation into lymph nodes, fast interstitial migration, even greater chemotactic responses to chemokines and sphingosine-1-phosphate, and entrance into lymphatic sinuses but severely delayed exit: mutant T cells retained high motility in lymphatic sinuses and frequently returned to the lymph node parenchyma, resulting in defective egress. These results reveal the critical trafficking processes that require Rap1 inactivation.


Asunto(s)
Integrinas , Linfocitos T , Adhesión Celular , Integrinas/metabolismo , Proteínas Activadoras de GTPasa/fisiología , Ganglios Linfáticos/metabolismo , Pulmón/metabolismo
8.
Int J Mol Sci ; 24(14)2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37511462

RESUMEN

Immune responses in humanized mice are generally inefficient without co-transplantation of human thymus or HLA transgenes. Previously, we generated humanized mice via the intra-bone marrow injection of CD133+ cord blood cells into irradiated adult immunodeficient mice (IBMI-huNSG mice), which could mount functional immune responses against HTLV-1, although the underlying mechanisms were still unknown. Here, we investigated thymocyte development in IBMI-huNSG mice, focusing on the roles of human and mouse MHC restriction. IBMI-huNSG mice had normal developmental profiles but aberrant thymic structures. Surprisingly, the thymic medulla-like regions expanded after immunization due to enhanced thymocyte expansion in association with the increase in HLA-DR+ cells, including CD205+ dendritic cells (DCs). The organ culture of thymus from immunized IBMI-huNSG mice with a neutralizing antibody to HLA-DR showed the HLA-DR-dependent expansion of CD4 single positive thymocytes. Mature peripheral T-cells exhibited alloreactive proliferation when co-cultured with human peripheral blood mononuclear cells. Live imaging of the thymus from immunized IBMI-huNSG mice revealed dynamic adhesive contacts of human-derived thymocytes and DCs accompanied by Rap1 activation. These findings demonstrate that an increase in HLA-DR+ cells by immunization promotes HLA-restricted thymocyte expansion in humanized mice, offering a unique opportunity to generate humanized mice with ease.


Asunto(s)
Leucocitos Mononucleares , Timocitos , Humanos , Ratones , Animales , Células Presentadoras de Antígenos , Timo , Antígenos HLA-DR , Inmunización
9.
iScience ; 26(8): 107292, 2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37520697

RESUMEN

Lymphocyte trafficking requires fine-tuning of chemokine-mediated cell migration. This process depends on cytoskeletal dynamics and polarity, but its regulation remains elusive. We quantitatively measured cell polarity and revealed critical roles performed by integrin activator Rap1 in this process, independent of substrate adhesion. Rap1-deficient naive T cells exhibited impaired abilities to reorganize the actin cytoskeleton into pseudopods and actomyosin-rich uropods. Rap1-GTPase activating proteins (GAPs), Rasa3 and Sipa1, maintained an unpolarized shape; deletion of these GAPs spontaneously induced cell polarization, indicative of the polarizing effect of Rap1. Rap1 activation required F-actin scaffolds, and stimulated RhoA activation and actomyosin contractility at the rear. Furthermore, talin1 acted on Rap1 downstream effectors to promote actomyosin contractility in the uropod, which occurred independently of substrate adhesion and talin1 binding to integrins. These findings indicate that Rap1 signaling to RhoA and talin1 regulates chemokine-stimulated lymphocyte polarization and chemotaxis in a manner independent of adhesion.

10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(9): 932-940, 2023 Sep 20.
Artículo en Japonés | MEDLINE | ID: mdl-37495539

RESUMEN

The purpose of this study was to evaluate the effectiveness of a hands-on seminar using a Web conferencing system, based on the post-event questionnaires of the face-to-face and online seminars of the hands-on seminar. For participants to feel realistic training in the online seminars, four educational videos explaining the procedure of the practical skill were created. We compared results of questionnaires acquired from participants after the face-to-face and online seminars. The questions about expectation, comprehension, satisfaction level, and lecture time for the seminars were graded on a 5-point scale. The higher the scores, the higher the rating, except for lecture time. A score of 3 was appropriate for the lecture time, with a higher score indicating that the seminar felt longer and a lower score indicating that the seminar felt shorter. In the evaluation of classroom lectures, such as expectation, comprehension, and satisfaction level for the seminars, there were no significant differences between the face-to-face and online seminars, and both achieved high scores of 4 or more. There was a significant difference in the evaluation of lecture time for classroom lectures, with participants feeling that it was too short in the face-to-face but just right in the online. In all evaluations for hands-on training and discussion, there were no significant differences between the face-to-face and online seminars, and both achieved high scores of 4 or more and time was short. It was concluded that our proposed online seminar approach could achieve a high level of evaluation as face-to-face seminars.


Asunto(s)
COVID-19 , Pandemias , Humanos , COVID-19/epidemiología , Encuestas y Cuestionarios
11.
J Radiat Res ; 64(4): 644-650, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37280131

RESUMEN

In volumetric modulated arc therapy (VMAT), the effect of an increase in skin surface dose due to topical agents might be negligible. We investigated the bolus effects of three types of topical agents in VMAT for head and neck cancer (HNC). Topical agents of different thicknesses (0.1, 0.5 and 2 mm) were prepared. When each topical agent was set, the surface doses were measured for the anterior static field and VMAT, with and without a thermoplastic mask. No significant differences were observed among the three topical agents. For topical agent thicknesses of 0.1, 0.5 and 2 mm, the increases in surface dose for the anterior static field without the thermoplastic mask were 7-9, 30-31 and 81-84%, respectively. With the thermoplastic mask, the corresponding increases were 5, 12-15 and 41-43%, respectively. The increases in surface dose for VMAT without the thermoplastic mask were 5-8, 16-19 and 36-39%, respectively, and those with the thermoplastic mask were 4, 7-10 and 15-19%, respectively. The rate of increase in surface dose with the thermoplastic mask was smaller than that without the thermoplastic mask. The increase in surface dose with topical agents of clinical standard thickness (0.02 mm) was estimated to be 2% with the thermoplastic mask. The increase in surface dose with topical agents in dosimetric simulation, compared with control situation, is not significant in clinical conditions for HNC patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias de Cabeza y Cuello/radioterapia , Radiometría
12.
Cell Rep ; 42(6): 112580, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37267105

RESUMEN

Bidirectional control of integrin activation plays crucial roles in cell adhesive behaviors, but how integrins are specifically regulated by inside-out and outside-in signaling has not been fully understood. Here, we report distinct bidirectional regulation of major lymphocyte homing receptors LFA1 and α4ß7 in primary T cells. A small increase of Rap1 activation in L-selectin-mediated tether/rolling was boosted by the outside-in signaling from ICAM1-interacting LFA1 through subsecond, simultaneous activation of Rap1 GTPase and talin1, but not kindlin-3, resulting in increased capture and slowing. In contrast, none of them were required for tether/rolling by α4ß7 on MAdCAM1. High Rap1 activation with chemokines or the loss of Rap1-inactivating proteins Rasa3 and Sipa1 increased talin1/kindlin-3-dependent arrest with high-affinity binding of LFA1 to membrane-anchored ICAM1. However, despite increased affinity of α4ß7, activated Rap1 severely suppressed adhesion on MAdCAM1 under shear flow, indicating the critical importance of a sequential outside-in/inside-out signaling for α4ß7.


Asunto(s)
Integrinas , Antígeno-1 Asociado a Función de Linfocito , Linfocitos T , Adhesión Celular/fisiología , Quimiocinas/metabolismo , Integrinas/metabolismo , Transducción de Señal/fisiología , Linfocitos T/metabolismo
13.
Anticancer Res ; 43(7): 3079-3087, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37351970

RESUMEN

BACKGROUND/AIM: Angiosarcoma of the scalp (AS) is a rare tumor that has often been treated by total scalp irradiation (TSI). TSI has technical and dosimetric challenges. This study aimed to compare the dosimetric performance of helical tomotherapy (HT) plans with that of HyperArc (HA) plans for TSI in AS. PATIENTS AND METHODS: A planning study was conducted for 11 patients with AS (70 Gy/35 fr). HT and HA planning was performed using TomoHDA and TrueBeam Edge systems, respectively. The performance of three different plans were compared: HT, HA, and HA with half-field beams (HF-HA). The dose distribution and dosimetric parameters for each plan were evaluated. RESULTS: All constraint parameters for the target and organs at risk (OARs) met the goals within acceptable limits for the three techniques. The HA and HF-HA plans provided significantly lower mean brain dose (12.46±2.48 Gy and 8.02±1.48 Gy) than did the HT plan (17.59±3.47 Gy). The doses receiving 0.1 cc of the volume for brainstem and chiasm were significantly lower in the HA and HF-HA plans than those in the HT plan. The HA and HF-HA plans provided a shorter beam-on time (155±3 s and 181±14 s) than did the HT plan (962±221 s). CONCLUSION: The HA plan provided significantly better OARs sparing than the HT plan for TSI in AS and had an advantage to using half-field beams.


Asunto(s)
Hemangiosarcoma , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Cuero Cabelludo , Hemangiosarcoma/radioterapia , Órganos en Riesgo/efectos de la radiación
14.
Angew Chem Int Ed Engl ; 62(30): e202303078, 2023 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-37199344

RESUMEN

A method for rotaxane synthesis by enlargement of the size of the terminal phenol group of the axle component by aromatic bromination has been developed. This method may be regarded as an end-capping strategy involving the swelling of the phenol group at the axle terminal. The advantages of the present strategy include: ready availability of axle components with a variety of swelling precursors, wide product scope (19 examples given including a [3]rotaxane), mild conditions for the swelling process, rich potential for the derivatization of the brominated rotaxanes, and possible release of the axle component by degradative dethreading of the thermally stable brominated rotaxanes under the basic conditions.

15.
Med Dosim ; 48(3): 197-201, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37202230

RESUMEN

This study aimed to compare dosimetric parameters for targets and organs at risk (OARs) between volumetric modulated arc therapy (VMAT) and automated VMAT (HyperArc, HA) plans in stereotactic radiotherapy for patients with cervical metastatic spine tumors. VMAT plans were generated for 11 metastases using the simultaneous integrated boost technique to deliver 35 to 40 and 20 to 25 Gy for high dose and elective dose planning target volume (PTVHD and PTVED), respectively. The HA plans were retrospectively generated using 1 coplanar and 2 noncoplanar arcs. Subsequently, the doses to the targets and OARs were compared. The HA plans provided significantly higher (p < 0.05) Dmin (77.4 ± 13.1%), D99% (89.3 ± 8.9%), and D98% (92.5 ± 7.7%) for gross tumor volume (GTV) than those of the VMAT plans (73.4 ± 12.2%, 84.2 ± 9.6 and 87.3 ± 8.8% for Dmin, D99% and D98%, respectively). In addition, D99% and D98% for PTVHD were significantly higher in the HA plans, whereas dosimetric parameters were comparable between the HA and VMAT plans for PTVED. The Dmax values for the brachial plexus, esophagus, and spinal cord were comparable, and no significant difference was observed in the Dmean for the larynx, pharyngeal constrictor, thyroid, parotid grand (left and right), and Submandibular gland (left and right). The HA plans provided significantly higher target coverage of GTV and PTVHD, with a comparable dose for OARs with VMAT plans. The results of this study may contribute to the improvement of local control in clinical practice.

16.
Phys Eng Sci Med ; 46(3): 1091-1100, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37247102

RESUMEN

PURPOSE: To evaluate whether knowledge-based volumetric modulated arc therapy plans for prostate cancer with a multi-institution model (broad model) are clinically useful and effective as a standardization method. METHODS: A knowledge-based planning (KBP) model was trained with 561 prostate VMAT plans from five institutions with different contouring and planning policies. Five clinical plans at each institution were reoptimized with the broad and single institution model, and the dosimetric parameters and relationship between Dmean and the overlapping volume (rectum or bladder and target) were compared. RESULTS: The differences between the broad and single institution models in the dosimetric parameters for V50, V80, V90, and Dmean were: rectum; 9.5% ± 10.3%, 3.3% ± 1.5%, 1.7% ± 1.6%, and 3.6% ± 3.6%, (p < 0.001), bladder; 8.7% ± 12.8%, 1.5% ± 2.6%, 0.7% ± 2.4%, and 2.7% ± 4.6% (p < 0.02), respectively. The differences between the broad model and clinical plans were: rectum; 2.4% ± 4.6%, 1.7% ± 1.7%, 0.7% ± 2.4%, and 1.5% ± 2.0%, (p = 0.004, 0.015, 0.112, and 0.009) bladder; 2.9% ± 5.8%, 1.6% ± 1.9%, 0.9% ± 1.7%, and 1.1% ± 4.8%, (p < 0.018), respectively. Positive values indicate that the broad model has a lower value. Strong correlations were observed (p < 0.001) in the relationship between Dmean and the rectal and bladder volume overlapping with the target in the broad model (R = 0.815 and 0.891, respectively). The broad model had the smallest R2 of the three plans. CONCLUSIONS: KBP with the broad model is clinically effective and applicable as a standardization method at multiple institutions.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estándares de Referencia
17.
Angew Chem Int Ed Engl ; 62(25): e202303750, 2023 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-37042088

RESUMEN

We propose a de novo glycan display approach that combines metabolic labeling and a glycan-caging strategy as a facile editing method for cell-surface glycans. This method enables the introduction of antigen glycans onto cancer cells to induce immune responses through antibody recruiting. The caging strategy prevents the capture of α-rhamnose (an antigen glycan) by endogenous antibodies during the introduction of the glycan to the targeted cell surface, and subsequent uncaging successfully induces immune responses. Therefore, this study proposes a practical method for editing the cell-surface glycocalyx under promiscuous conditions, such as those in vivo, which paves the way for the development of glycan function analysis and regulation.


Asunto(s)
Anticuerpos , Polisacáridos , Polisacáridos/metabolismo , Membrana Celular/metabolismo , Ramnosa
18.
Radiol Phys Technol ; 16(2): 310-318, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37093409

RESUMEN

To compare the dosimetric parameters of automated noncoplanar volumetric modulated arc therapy plans using single-isocentric (SIC) and multi-isocentric (MIC) techniques for patients with two brain metastases (BMs) in stereotactic irradiation and to evaluate the robustness of rotational errors. The SIC and MIC plans were retrospectively generated (35 Gy/five fractions) for 58 patients. Subsequently, a receiver operating characteristic curve analysis between the tumor surface distance (TSD) and V25Gy was performed to determine the thresholds for the brain tissue. The SIC and MIC plans were recalculated based on the rotational images to evaluate the dosimetric impact of rotational error. The MIC plans showed better brain tissue sparing for TSD > 6.6 cm. The SIC plans provided a significantly better conformity index for TSD ≤ 6.6 cm, while significantly lower gradient index was obtained (3.22 ± 0.56vs. 3.30 ± 0.57, p < 0.05) in the MIC plans with TSD > 6.6 cm. For organs at risk (OARs) (brainstem, chiasm, lens, optic nerves, and retinas), D0.1 cc was significantly lower (p < 0.05) in the MIC plans than in the SIC plans. The prescription dose could be delivered (D99%) to the gross tumor volume (GTV) for patients with TSD ≤ 6.6 cm when the rotational error was < 1°, whereas 31% of the D99% of GTV fell below the prescription dose with TSD > 6.6 cm. MIC plans can be an optimal approach for reducing doses to OARs and providing robustness against rotational errors in BMs with TSD > 6.6 cm.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/patología , Órganos en Riesgo , Radiocirugia/métodos
19.
In Vivo ; 37(1): 417-423, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36593035

RESUMEN

BACKGROUND/AIM: Dosimetric parameters in volumetric modulated arc therapy (VMAT), non-coplanar VMAT (NC-VMAT), and automated NC-VMAT (HyperArc, HA) were compared for patients with maxillary sinus carcinoma (MSC). PATIENTS AND METHODS: Twenty HA plans were generated to deliver 70.4, 64, and 46 Gy for planning target volumes with high (PTV1), intermediate (PTV2), and low risk (PTV3), respectively. The VMAT and NC-VMAT plans were retrospectively generated using the same optimized parameters as those used in the HA plans. RESULTS: For PTV1, the three treatment plans provided comparable target coverages. For PTV2, the D95%, D99%, and Dmin in the HA plans (64.7±1.2, 62.7±2.1 and 54.6±6.2 Gy, respectively) were significantly higher (p<0.05) than those in the VMAT plans (64.3±1.7, 61.9±2.4 and 52.9±6.4 Gy, respectively). The NC-VMAT and HA plans provided significantly higher (p<0.05) dosimetric parameters for PTV3 than those in the VMAT plans, and D99% in the HA was significantly higher than that in the NC-VMAT plans (52.5±3.0 vs. 51.8±2.7 Gy, p<0.05). The doses to the brain and brainstem were lowest in the HA plans (p<0.05). Moreover, dosimetric parameters of the contralateral organs (lens, optic nerve, retina, and parotid) were lower in the HA plans than in the VMAT and NC-VMAT plans. CONCLUSION: The HA plans provided the best target coverage and OAR sparing compared with VMAT and NC-VMAT plans for patients with MSC.


Asunto(s)
Carcinoma , Radioterapia de Intensidad Modulada , Humanos , Seno Maxilar , Dosificación Radioterapéutica , Órganos en Riesgo , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador
20.
Angew Chem Int Ed Engl ; 62(13): e202218655, 2023 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-36719065

RESUMEN

Asparagine-linked protein glycosylations (N-glycosylations) are one of the most abundant post-translational modifications and are essential for various biological phenomena. Herein, we describe the isolation, structural determination, and chemical synthesis of the N-glycan from the hyperthermophilic archaeon Thermococcus kodakarensis. The N-glycan from the organism possesses a unique structure including myo-inositol, which has not been found in previously characterized N-glycans. In this structure, myo-inositol is highly glycosylated and linked with a disaccharide unit through a phosphodiester. The straightforward synthesis of this glycan was accomplished through diastereoselective phosphorylation and phosphodiester construction by SN 2 coupling. Considering the early divergence of hyperthermophilic organisms in evolution, this study can be expected to open the door to approaching the primitive function of glycan modification at the molecular level.


Asunto(s)
Thermococcus , Inositol/metabolismo , Polisacáridos/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...