Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(20)2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37896460

RESUMEN

The fabrication of a zinc hydroxide nitrate-sodium dodecylsulfate bispyribac modified with multi-walled carbon nanotube (ZHN-SDS-BP/MWCNT) paste electrode for uric acid and bisphenol A detection was presented in this study. Electrochemical impedance spectroscopy, chronocoulometry, square-wave voltammetry, and cyclic voltammetry were all used to examine the electrocatalytic activities of modified paste electrodes. The modified electrode's sensitivity and selectivity have been considered in terms of the composition of the modifier in percentages, the types of supporting electrolytes used, the pH of the electrolyte, and square-wave voltammetry parameters like frequency, pulse size, and step increment. Square-wave voltammetry is performed by applying a small amplitude square-wave voltage to a scanning potential from -0.3 V to +1.0 V, demonstrating a quick response time and high sensitivity. The ZHN-SDS-BP/MWCNT sensor demonstrated a linear range for uric acid and bisphenol A from 5.0 µM to 0.7 mM, with a limit of detection of 0.4 µM and 0.8 µM, respectively, with good reproducibility, repeatability, and stability as well. The modified paste electrode was successfully used in the determination of uric acid and bisphenol A in samples of human urine and lake water.


Asunto(s)
Nanocompuestos , Ácido Úrico , Humanos , Ácido Úrico/orina , Dodecil Sulfato de Sodio , Reproducibilidad de los Resultados , Técnicas Electroquímicas/métodos , Electrodos , Nanocompuestos/química , Sodio
2.
Biotechnol Appl Biochem ; 69(3): 1121-1147, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33987922

RESUMEN

Metal phosphides, especially aluminum phosphide, and phosphine (PH3 ) are widely used as insecticides and rodenticides for protection of grains during process of storage and transportation. The main reason of poisoning with this compound is related to the conscious ingestion of salts or accidental inhalation of PH3 . So the early and accurate diagnosis of poisoning can significantly help to the effective clinical treatment or recognition of death cause. PH3 is somewhat unstable due to reaction with oxygen or hemoglobin leading to formation of oxy-acids phosphorous. Here, we critically reviewed the literature introducing the quantitative and qualitative methods for the detection of metal phosphides, PH3 , and its products. This study obviously demonstrates that during past years, different diagnosis methods have been remarkably progressed. Head-space gas chromatography and confirmatory colorimetric methods have been as the most popular techniques. Also, the gas sensors are a promising method that must be more progressed.


Asunto(s)
Insecticidas , Rodenticidas
3.
Materials (Basel) ; 14(13)2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34209933

RESUMEN

The objective of this study is to investigate Napa soil's potential as an alternative additive in producing Portland composite cement. The Napa soil of Tanah Datar district, West Sumatra, Indonesia is a natural material which contains SiO2 and Al2O3 as its major components. The parameters used were the fineness of the cement particles, the amount left on a 45 µm sieve, the setting time, normal consistency, loss on ignition, insoluble parts, compressive strength and chemical composition. The composition of Napa soils (% w/w) used as variables include 4, 8, 12 and 16%. Furthermore, 8% pozzolan was used as a control in this research. The results showed that the compressive strength of Napa soil cement which contained 4% Napa soil was much better compared to that of the control on the 7th and 20th day. Furthermore, all the analyzed Napa soil cements met the standard of cement as stipulated in Indonesian National Standard, SNI 7064, 2016.

4.
Sensors (Basel) ; 20(7)2020 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-32218202

RESUMEN

A DNA micro-optode for dengue virus detection was developed based on the sandwich hybridization strategy of DNAs on succinimide-functionalized poly(n-butyl acrylate) (poly(nBA-NAS)) microspheres. Gold nanoparticles (AuNPs) with an average diameter of ~20 nm were synthesized using a centrifugation-based method and adsorbed on the submicrometer-sized polyelectrolyte-coated poly(styrene-co-acrylic acid) (PSA) latex particles via an electrostatic method. The AuNP-latex spheres were attached to the thiolated reporter probe (rDNA) by Au-thiol binding to functionalize as an optical gold-latex-rDNA label. The one-step sandwich hybridization recognition involved a pair of a DNA probe, i.e., capture probe (pDNA), and AuNP-PSA reporter label that flanked the target DNA (complementary DNA (cDNA)). The concentration of dengue virus cDNA was optically transduced by immobilized AuNP-PSA-rDNA conjugates as the DNA micro-optode exhibited a violet hue upon the DNA sandwich hybridization reaction, which could be monitored by a fiber-optic reflectance spectrophotometer at 637 nm. The optical genosensor showed a linear reflectance response over a wide cDNA concentration range from 1.0 × 10-21 M to 1.0 × 10-12 M cDNA (R2 = 0.9807) with a limit of detection (LOD) of 1 × 10-29 M. The DNA biosensor was reusable for three consecutive applications after regeneration with mild sodium hydroxide. The sandwich-type optical biosensor was well validated with a molecular reverse transcription polymerase chain reaction (RT-PCR) technique for screening of dengue virus in clinical samples, e.g., serum, urine, and saliva from dengue virus-infected patients under informed consent.


Asunto(s)
Técnicas Biosensibles , ADN Viral/aislamiento & purificación , Virus del Dengue/aislamiento & purificación , Dengue/diagnóstico , Acrilatos/química , ADN Viral/química , Dengue/virología , Virus del Dengue/patogenicidad , Oro/química , Humanos , Nanopartículas del Metal/química , Microesferas , Polímeros/química , Succinimidas/química
5.
Sensors (Basel) ; 12(5): 5445-60, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22778594

RESUMEN

An electrochemical microbiosensor for DNA has been fabricated based on new acrylic microspheres modified with reactive N-acryloxysuccinimide (NAS) functional groups. Hydrophobic poly(n-butylacrylate-N-acryloxysuccinimide) microspheres were synthesized in an emulsion form with a simple one-step photopolymerization technique. Aminated DNA probe was attached to the succinimde functional group of the acrylic microspheres via covalent bonding. The hybridization of the immobilized DNA probe with the complementary DNA was studied by differential pulse voltametry using anthraquninone-2-sulfonic acid monohydrate sodium salt (AQMS) as the electroactive hybridization label. The influences of many factors such as duration of DNA probe immobilization and hybridization, pH, type of ions, buffer concentrations, ionic strength, operational temperature and non-complementary DNA on the biosensor performance were evaluated. Under optimized conditions, the DNA microbiosensor demonstrated a linear response range to target DNA over a wide concentration range of 1.0 × 10(-16) and 1.0 × 10(-8) M with a lower limit of detection (LOD) of 9.46 × 10(-17) M (R(2) = 0.97). This DNA microbiosensor showed good reproducibility with 2.84% RSD (relative standard deviation) (n = 3). Application of the NAS-modified acrylic microspheres in the construction of DNA microbiosensor had improved the overall analytical performance of the resultant DNA microbiosensor when compared with other reported DNA biosensors using other nano-materials for membranes and microspheres as DNA immobilization matrices.


Asunto(s)
Técnicas Biosensibles , ADN/análisis , Técnicas Electroquímicas/instrumentación , Succinimidas/química , Secuencia de Bases , Sondas de ADN , Concentración de Iones de Hidrógeno , Microscopía Electrónica de Rastreo , Microesferas , Concentración Osmolar
6.
Sensors (Basel) ; 11(9): 8323-38, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22164078

RESUMEN

New acrylic microspheres were synthesised by photopolymerisation where the succinimide functional group was incorporated during the microsphere preparation. An optical biosensor for urea based on reflectance transduction with a large linear response range to urea was successfully developed using this material. The biosensor utilized succinimide-modified acrylic microspheres immobilized with a Nile blue chromoionophore (ETH 5294) for optical detection and urease enzyme was immobilized on the surface of the microspheres via the succinimide groups. No leaching of the enzyme or chromoionophore was observed. Hydrolysis of the urea by urease changes the pH and leads to a color change of the immobilized chromoionophore. When the color change was monitored by reflectance spectrophotometry, the linear response range of the biosensor to urea was from 0.01 to 1,000 mM (R2 = 0.97) with a limit of detection of 9.97 µM. The biosensor response showed good reproducibility (relative standard deviation = 1.43%, n = 5) with no interference by major cations such as Na+, K+, NH4+ and Mg2+. The use of reflectance as a transduction method led to a large linear response range that is better than that of many urea biosensors based on other optical transduction methods.


Asunto(s)
Técnicas Biosensibles , Microesferas , Succinimidas/química , Urea/química , Enzimas Inmovilizadas/química , Concentración de Iones de Hidrógeno , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados , Espectroscopía Infrarroja por Transformada de Fourier , Ureasa/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...