1.
J Orthop Res ; 35(9): 2007-2016, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27813260

RESUMEN

To reduce the production of wear particles and subsequent aseptic loosening, we created a human articular cartilage-mimicked surface for a highly cross-linked polyethylene liner, whose surface grafted layer consisted of a biocompatible phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine). Although our previous in vitro findings showed that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted particles were biologically inert and caused no subsequent bone resorptive responses, and poly(2-methacryloyloxyethyl phosphorylcholine) grafting markedly decreased wear in hip joint simulator tests, the clinical safety, and in vivo wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners remained open to question. Therefore, in the present study, we evaluated clinical and radiographic outcomes of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners 5 years subsequent to total hip replacement in 68 consecutive patients. No reoperation was required for any reason, and no adverse events were associated with the implanted liners. The average Harris Hip Score increased from 38.6 preoperatively to 96.5 5 years postoperatively, and health-related quality of life, as indicated by the Short Form 36 Health Survey, improved. Radiographic analyses showed no periprosthetic osteolysis or implant migration. Between 1 and 5 years postoperatively, the mean steady-state wear rate was 0.002 mm/year, which represented a marked reduction relative to other highly cross-linked polyethylene liners, and appeared to be unaffected by patient-related or surgical factors. Although longer follow up is required, poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners improved mid-term clinical outcomes. The clinical safety and wear-resistance results are encouraging with respect to the improvement of long-term clinical outcomes with poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2007-2016, 2017.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/estadística & datos numéricos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polietileno , Diseño de Prótesis , Calidad de Vida , Radiografía , Estudios Retrospectivos
2.
Mod Rheumatol ; 25(2): 286-91, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25109744

RESUMEN

OBJECTIVES: This study aimed to evaluate the clinical safety and wear-resistance of the novel highly cross-linked polyethylene (HXLPE) acetabular liner with surface grafting of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) at 3 years after total hip replacement (THR). METHODS: Eighty consecutive patients underwent cementless THR using a 26-mm diameter cobalt-chromium-molybdenum alloy femoral head and a PMPC-grafted HXLPE liner for the bearing couplings. We evaluated the clinical and radiographic outcomes of 76 patients at 3 years after the index surgery. RESULTS: The clinical results at 3 years were equivalent to a Harris hip score of 95.6 points. No adverse events were associated with the implanted PMPC-grafted HXLPE liner, and no periprosthetic osteolysis was detected. The mean femoral head penetration rate was 0.002 mm/year, representing marked reduction compared with other HXLPE liners. CONCLUSIONS: A PMPC-grafted HXLPE liner is a safe option in THR and probably reduces the generation of wear particles.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Necrosis de la Cabeza Femoral/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Fosforilcolina/análogos & derivados , Ácidos Polimetacrílicos , Adulto , Anciano , Femenino , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Estudios Prospectivos , Radiografía , Resultado del Tratamiento
3.
J Artif Organs ; 16(2): 170-5, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23238557

RESUMEN

To control particle-induced osteolysis in total hip replacement (THR), we developed a new technique to graft poly(2-methacryloyloxyethyl phosphorylcholine) onto the surface of polyethylene liners. A prospective cohort study was conducted to investigate the clinical safety of this novel bearing surface. Between April 2007 and September 2008, we recruited a prospective consecutive series of 80 patients in five participating hospitals. These patients received a cementless THR; a 26-mm-diameter cobalt-chromium-molybdenum alloy ball and a poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liner were used for the bearing couplings. These individuals were followed a year postoperatively. An evaluation of clinical performance was conducted through an assessment of hip joint function based on the evaluation chart authorized by the Japanese Orthopaedic Association. No patients were lost to follow-up. No adverse events were found to be correlated with the implanted liners. The average hip joint function score improved from 43.2 preoperatively to 91.7 postoperatively at 1 year. There was no implant migration nor periprosthetic osteolysis detected on radiographic analysis. On the basis of our results, we conclude that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liners are a safe implant option for hip replacement surgery for short-term clinical use.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Metacrilatos , Fosforilcolina/análogos & derivados , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polietilenos , Ácidos Polimetacrílicos , Complicaciones Posoperatorias , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
4.
J Orthop Sci ; 7(4): 467-71, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12181661

RESUMEN

We studied the radiographic results of bipolar revision hip arthroplasty in 25 patients (25 hips). These patients had suffered from osteoarthrosis of the hip due to acetabular dysplasia and had undergone total hip replacement using smooth threaded acetabular components. In the revision surgery, these components were replaced by bipolar cups; autografts were implanted in 23 patients and hydroxyapatite grains were added in 7. At the time of follow-up, the severity of migration was radiographically graded from I to IV: grade I, 5 mm or less; grade II, 6 to 10 mm; grade III, 11 to 15 mm; and grade IV, 16 mm or more. Five to 11 years (average, 7.0 years) after surgery, 9 patients were classified as grade I, 6 as grade II, 4 as grade III, and 6 as grade IV. Among the 6 individuals with grade IV migration, hydroxyapatite grains had been used in 5. There was a significant negative correlation between the distance of migration and the increase in size of the threaded acetabular components used in the primary total hip replacement and the bipolar cups in the revision surgery. Because of the tendency to migrate, we concluded that this procedure has a limited role in revision surgery.


Asunto(s)
Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Osteoartritis de la Cadera/cirugía , Reoperación/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Durapatita/farmacología , Femenino , Estudios de Seguimiento , Humanos , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico , Diseño de Prótesis , Radiografía , Rango del Movimiento Articular/fisiología , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...