Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Clin Endosc ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38919059

RESUMEN

Background/Aims: Dilation of the tract before stent deployment is a challenging step in endoscopic ultrasound-guided pancreatic duct drainage (EUS-PDD). In this study, we examined the effectiveness and safety of a novel spiral dilator, Tornus ES (Asahi Intec), for EUS-PDD. Methods: This was a retrospective, single-arm, observational study at Aichi Cancer Center Hospital. The punctured tract was dilated using a Tornus ES dilator in all EUS-PDD cases. Our primary endpoint was the technical success rate of initial tract dilation. Technical success was defined as successful fistula dilation using Tornus ES followed by successful stent insertion. Secondary endpoints were procedure times and early adverse events. Results: A total of 12 patients were included between December 2021 and March 2023. EUS-PDD was performed in 11 patients for post-pancreaticoduodenectomy anastomotic strictures and one patient with pancreatitis with duodenal perforation. The technical success rates of stent insertion and fistula dilation using Tornus ES dilator was 100%. The median procedure time was 24 minutes. No remarkable adverse events related to the procedure were observed, apart from fever, which occurred in 2 patients. Conclusions: Tract dilation in EUS-PDD using Tornus ES is effective and safe.

3.
Intern Med ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38403760

RESUMEN

Objective Adverse events such as bile leakage and bleeding are among the issues that need to be resolved in EUS-guided choledochoduodenostomy (EUS-CDS). To overcome this problem, we developed a new EUS-CDS technique using a 19-G Franseen needle without tract dilation. This study aimed to evaluate the safety and efficacy of the new EUS-CDS technique. Methods This single-center retrospective study included 20 consecutive patients who underwent EUS-CDS for primary drainage using a 19-G Franseen needle between March 2020 and May 2023. The primary endpoint was the technical success rate of EUS-CDS without tract dilation. Results The technical success rate of EUS-CDS was 20/20 (100%). None of the patients required any additional tract dilation, such as by using a balloon or electric cautery. The median procedure time was 7.8 (range, 3.2-19.4) min. No early adverse events were observed. Conclusion The 19-G Franseen needle appeared to have a sufficient dilatory effect during puncturing. This EUS-CDS technique appears to be safe and effective and has the advantages of no adverse events and it is also a simplified procedure, which suggests its potential for widespread use in primary drainage.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...