Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Vascular ; 30(5): 867-873, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34320878

RESUMEN

OBJECTIVES: Current diagnostic modalities for patients with peripheral artery disease (PAD) mainly focus on the macrovascular level. For assessment of tissue perfusion, near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) seems promising. In this prospective cohort study, ICG NIR fluorescence imaging was performed pre- and post-revascularization to assess changes in foot perfusion. METHODS: ICG NIR fluorescence imaging was performed in 36 patients with PAD pre- and post-intervention. After intravenous bolus injection of 0.1 mg/kg ICG, the camera registered the NIR fluorescence intensity over time on the dorsum of the feet for 15 min using the Quest Spectrum Platform®. Time-intensity curves were plotted for three regions of interest (ROI): (1) the dorsum of the foot, (2) the forefoot, and (3) the hallux. Time-intensity curves were normalized for maximum fluorescence intensity. Extracted parameters were the maximum slope, area under the curve (AUC) for the ingress, and the AUC for the egress. The non-treated contralateral leg was used as a control group. RESULTS: Successful revascularization was performed in 32 patients. There was a significant increase for the maximum slope and AUC egress in all three ROIs. The most significant difference was seen for the maximum slope in ROI 3 (3.7%/s to 6.6%/s, p < 0.001). In the control group, no significant differences were seen for the maximum slope and AUC egress in all ROIs. CONCLUSIONS: This study shows the potential of ICG NIR fluorescence imaging in assessing the effect of revascularization procedures on foot perfusion. Future studies should focus on the use of this technique in predicting favorable outcome of revascularization procedures.


Asunto(s)
Verde de Indocianina , Enfermedad Arterial Periférica , Humanos , Imagen Óptica/métodos , Perfusión , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Estudios Prospectivos , Procedimientos Quirúrgicos Vasculares
2.
Ann Vasc Surg ; 78: 281-287, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34182113

RESUMEN

BACKGROUND: Patients with chronic limb threatening ischemia have a risk of undergoing a major amputation within 1 year of nearly 30% with a substantial risk of re-amputation since wound healing is often impaired. Quantitative assessment of regional tissue viability following amputation surgery can identify patients at risk for impaired wound healing. In quantification of regional tissue perfusion, near-infrared (NIR) fluorescence imaging using Indocyanine Green (ICG) seems promising. METHODS: This pilot study included adult patients undergoing lower extremity amputation surgery due to peripheral artery disease or diabetes mellitus. ICG NIR fluorescence imaging was performed within 5 days following amputation surgery using the Quest Spectrum PlatformⓇ. Following intravenous administration of ICG, the NIR fluorescence intensity of the amputation wound was recorded for 10 minutes. The NIR fluorescence intensity videos were analyzed and if a fluorescence deficit was observed, this region was marked as "low fluorescence." All other regions were marked as "normal fluorescence." RESULTS: Successful ICG NIR fluorescence imaging was performed in 10 patients undergoing a total of 15 amputations. No "low fluorescence" regions were observed in 11 out of 15 amputation wounds. In 10 out of these 11 amputations, no wound healing problems occurred during follow-up. Regions with "low fluorescence" were observed in 4 amputation wounds. Impaired wound healing corresponding to these regions was observed in all wounds and a re-amputation was necessary in 3 out of 4. When observing time-related parameters, regions with low fluorescence had a significantly longer time to maximum intensity (113 seconds vs. 32 seconds, P = 0.003) and a significantly lesser decline in outflow after five minutes (80.3% vs. 57.0%, P = 0.003). CONCLUSIONS: ICG NIR fluorescence imaging was able to predict postoperative skin necrosis in all four cases. Quantitative assessment of regional perfusion remains challenging due toinfluencing factors on the NIR fluorescence intensity signal, including camera angle, camera distance and ICG dosage. This was also observed in this study, contributing to a large variety in fluorescence intensity parameters among patients. To provide surgeons with reliable NIR fluorescence cut-off values for prediction of wound healing, prospective studies on the intra-operative use of this technique are required. The potential prediction of wound healing using ICG NIR fluorescence imaging will have a huge impact on patient mortality, morbidity as well as the burden of amputation surgery on health care.


Asunto(s)
Amputación Quirúrgica , Angiopatías Diabéticas/cirugía , Colorantes Fluorescentes/administración & dosificación , Verde de Indocianina/administración & dosificación , Isquemia/cirugía , Imagen de Perfusión , Enfermedad Arterial Periférica/cirugía , Piel/irrigación sanguínea , Espectroscopía Infrarroja Corta , Anciano , Enfermedad Crónica , Angiopatías Diabéticas/diagnóstico por imagen , Angiopatías Diabéticas/fisiopatología , Femenino , Humanos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Necrosis , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Piel/patología , Supervivencia Tisular , Resultado del Tratamiento , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...