Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37605804

RESUMEN

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Calidad de Vida , Anticoagulantes/uso terapéutico , Hemorragia , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
2.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480891

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Incidencia , Bloqueo de Rama , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36649387

RESUMEN

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Tiempo , Resultado del Tratamiento , Sistema de Registros , Diseño de Prótesis , Factores de Riesgo
4.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-32865376

RESUMEN

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Asunto(s)
Aspirina/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Aspirina/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Femenino , Hemorragia/epidemiología , Humanos , Incidencia , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Periodo Posoperatorio , Trombosis/epidemiología
5.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-32223116

RESUMEN

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Asunto(s)
Anticoagulantes/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Hemorragia/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
6.
Am J Cardiol ; 125(9): 1369-1377, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32098656

RESUMEN

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on pre-BAV was available for 1,262 patients (99.9%). Primary end points were pre-discharge moderate-to-severe paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation, and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n = 1,051) or without predilatation (n = 211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs 3.4%, p = 0.214; 30-day permanent pacemaker implantation 9.0% vs 8.0%, p = 0.660; 30-day death or stroke 4.9% vs 4.4%, p = 0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/instrumentación , Dilatación/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Humanos , Masculino , Periodo Preoperatorio , Sistema de Registros , Estudios Retrospectivos
7.
Curr Cardiol Rep ; 21(5): 37, 2019 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-30924027

RESUMEN

PURPOSE OF REVIEW: This review aims to provide an updated overview and a clinical perspective on novel transcatheter tricuspid valve interventions (TTVI), highlighting potential challenges and future directions. RECENT FINDINGS: Severe tricuspid regurgitation (TR) is a predictor of mortality. However, a sizeable number of patients remain untreated until the end-stage when cardiac surgery presents a prohibitive risk. The emergent need in finding a treatment for patients with TR, deemed for surgery options, has encouraged the development of TTVI. These procedures mimic classical surgery techniques and are mainly divided in four categories: annuloplasty and coaptation devices, edge-to-edge techniques and transcatheter tricuspid valve replacement. Early studies showed promising results, but long-term follow-up data are not available. For patients with severe TR and high surgical risk, several percutaneous options are available. However, these therapies are in a growing phase and bigger studies and long term follow-up are needed to prove their efficacy.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Humanos , Resultado del Tratamiento
8.
JACC Cardiovasc Interv ; 12(5): 433-443, 2019 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-30846081

RESUMEN

OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Puntaje de Propensión , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
Int J Cardiol ; 283: 84-87, 2019 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-30449693

RESUMEN

Percutaneous recanalization of coronary chronic total occlusions (CTOs) traditionally relies on the use of dual access and large bore catheters, with trans-femoral approach adoption in most of the cases. Aim of this manuscript is to describe an alternative algorithm, that we called "Minimalistic Hybrid Algorithm", in order to minimize the use of double access, large bore catheters, and femoral approach thus reducing patient's discomfort and possibly procedural complications. This algorithm can be interpreted as an evolution of the classic "Hybrid Algorithm" and requires the operator to be confident with all techniques known in this conventional algorithm. Indeed, all possible techniques and approaches of the conventional hybrid approach to treat CTOs are included in a novel diagram for procedural strategy, which offers an alternative sequence of steps to limit, whenever possible, the invasiveness of the procedure. After dividing the cases in "simple" or "complex" CTO lesions according to the available complexity scores and to the "feeling", knowledge and expertise of the operator, a systematic description of the procedural steps is provided. This includes antegrade and retrograde approaches, as well as sub-intimal and intra-luminal techniques, in order to maintain the simpler single-catheter transradial strategies in the first line for the simple CTO, and the adoption of more complex, double access and transfemoral ones in the further steps. The minimalistic hybrid algorithm herein described is a possible alternative sequence of steps in the setting of CTO recanalization, with the potential of limiting the use of double access, large bore catheters, and femoral approach.


Asunto(s)
Algoritmos , Oclusión Coronaria/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Intervención Coronaria Percutánea/métodos , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Arteria Femoral , Humanos , Arteria Radial
10.
Catheter Cardiovasc Interv ; 93(6): 1097-1105, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30461187

RESUMEN

OBJECTIVE: The aim of this study was to describe the early use of dedicated patient specific computer modeling in patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve implantation (TAVI), in predicting procedure feasibility and patient related outcome. BACKGROUND: Dedicated patient specific computer modeling, used for optimizing TAVI procedures, is currently validated for the prediction of contact pressure, valve morphology and paravalvular leakage (PVL). The simulation of TAVI procedures is increasingly used in patients with tricuspid aortic valve stenosis. Currently, BAV disease is considered as a relative contra-indication for TAVI due to its specific anatomical characteristics. METHODS: This single center study consisted of seven patients with BAV undergoing TAVI. A patient specific computer simulation was performed based on multislice computer tomography images. The model advised the best fitting prosthetic valve size or sizes and simulated this valve on different implantation depths with the corresponding presence and severity of PVL and prosthetic valve morphology. The simulation results were compared with the procedural outcomes using transesophageal echocardiography (TEE) and fluoroscopy. RESULTS: The patient specific computer modeling predicted accurately the outcome (PVL and valve morphology) of TAVI in all cases. In one case, the TAVI procedure was unsuccessful and retrospectively not suitable for TAVI, which was correctly predicted by the model. CONCLUSION: The patient specific computer modeling adequately predicts feasibility and outcome of TAVI in patients with BAV disease and may extend the applicability of TAVI. Moreover, it improves decision-making and therefore individual procedural outcomes in this difficult patient population.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/complicaciones , Modelos Cardiovasculares , Modelación Específica para el Paciente , Cirugía Asistida por Computador , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Toma de Decisiones Clínicas , Técnicas de Apoyo para la Decisión , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Humanos , Masculino , Tomografía Computarizada Multidetector , Selección de Paciente , Diseño de Prótesis , Estudios Retrospectivos , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
12.
Am J Cardiol ; 121(10): 1239-1245, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29525062

RESUMEN

Transcatheter aortic valve implantation (TAVI) is associated with acute kidney injury (AKI), but can also improve the kidney function (IKF). We assessed the effects of kidney function changes in relation to baseline kidney function on 2-year clinical outcomes after TAVI. In total, 639 consecutive patients with aortic stenosis who underwent TAVI were stratified into 3 groups according to the ratio of serum creatinine post- to pre-TAVI: IKF (≤0.80; n = 95 [15%]), stable kidney function (0.80 to 1.5; n = 477 [75%]), and AKI (≥1.5; n = 67 [10%]). Different AKI risk scores were compared using receiving-operator characteristics. Median follow-up was 24 (8 to 44) months. At 3 months, the increase in estimated glomerular filtration rate in the IKF group remained, and the decreased estimated glomerular filtration rate in the AKI group recovered. Compared with a stable kidney function, AKI showed a higher 2-year mortality rate (adjusted hazard ratio [HR] 3.69, 95% confidence interval [CI] 2.43 to 5.62) and IKF a lower mortality rate (adjusted hazard ratio 0.53, 95% CI 0.30 to 0.93). AKI also predicted major and life-threatening bleeding (adjusted odds ratio 2.94, 95% CI 1.27 to 6.78). Independent predictors of AKI were chronic kidney disease and pulmonary hypertension. Independent predictors of IKF were female gender, a preserved kidney function, absence of atrial fibrillation, and hemoglobin level. Established AKI risk scores performed moderately and did not differentiate between AKI and IKF. In conclusion, AKI is transient and is independently associated with a higher mortality rate, whereas IKF is sustained and is associated with a lower mortality rate. These effects are independent of baseline kidney function. Further studies are warranted to investigate the role of IKF and generate a dedicated prediction model.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Creatinina/metabolismo , Tasa de Filtración Glomerular , Insuficiencia Renal Crónica/metabolismo , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/epidemiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Comorbilidad , Femenino , Hemorragia/epidemiología , Humanos , Hipertensión Pulmonar/epidemiología , Modelos Lineales , Modelos Logísticos , Masculino , Mortalidad , Oportunidad Relativa , Complicaciones Posoperatorias/epidemiología , Pronóstico , Modelos de Riesgos Proporcionales , Insuficiencia Renal Crónica/epidemiología , Estudios Retrospectivos , Factores Sexuales , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 92(5): E299-E307, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29411523

RESUMEN

BACKGROUND: Coronary chronic total occlusions (CTO) usually coexist with diffusely diseased coronary segments proximal and/or distal to the CTO segment. During percutaneous treatment of CTO, multiple overlapping stents are often needed to treat these long lesions. OBJECTIVES: Aim of this study is to report the first use of long, tapered coronary sirolimus-eluting stents (SES) in this setting. METHODS AND RESULTS: This is a retrospective analysis of 100 consecutive patients undergoing CTO recanalization following the hybrid algorithm. Procedural success rate was 89% (11 failures). Among the successful cases, "conventional" drug-eluting stents(DES) were used in 40(44.9%) patients, while in 49(55%) patients long-tapered SES were attempted with a success rate of 98% (1 cross-over to regular stents). Total stent length in the long-tapered DES group was higher compared to the "conventional" stenting group (76 ± 28 mm vs 46 ± 22 mm, P < .001), with a similar total number of stent (1.6 ± 0.8 vs 1.9 ± 0.8). At quantitative coronary analysis, proximal and distal segment involvement was more extended in patients undergoing long-tapered stenting, with longer overall lesion length. No differences in periprocedural complications and clinical outcomes at a mean follow-up of 303 ± 179 days were observed. CONCLUSIONS: The use of long tapered coronary DES is technically feasible and safe for the percutaneous treatment of CTOs, especially for patients presenting with long lesions.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Oclusión Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad Crónica , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
14.
Am J Cardiol ; 120(11): 2035-2040, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29033048

RESUMEN

Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is available. The aim of the current study was to compare the clinical outcome after MitraClip treatment in patients with versus without atrial fibrillation. Between January 2009 and January 2016, all consecutive patients treated with a MitraClip in 5 Dutch centers were included. Outcome measures were survival, symptoms, MR grade, and stroke incidence. In total, 618 patients were treated with a MitraClip. Patients with AF were older, had higher N-terminal B-type natriuretic peptide levels, more tricuspid regurgitation, less often coronary artery disease and a better left ventricular function. Survival of patients treated with the MitraClip was similar for patients with AF (82%) and without AF (non-AF; 85%) after 1 year (p = 0.30), but significantly different after 5-year follow-up (AF 34%; non-AF 47%; p = 0.006). After 1 month, 64% of the patients with AF were in New York Heart Association class I or II, in contrast to 77% of the patients without AF (p = 0.001). The stroke incidence appeared not to be significantly different (AF 1.8%; non-AF 1.0%; p = 0.40). In conclusion, patients with AF had similar 1-year survival, MR reduction, and stroke incidence compared with non-AF patients. However, MitraClip patients with AF had reduced long-term survival and remained more symptomatic compared with those without AF.


Asunto(s)
Fibrilación Atrial/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Complicaciones Posoperatorias/epidemiología , Función Ventricular Izquierda/fisiología , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Ecocardiografía Transesofágica , Electrocardiografía , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/mortalidad , Países Bajos/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
17.
Cardiovasc Diagn Ther ; 6(2): 160-5, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27054105

RESUMEN

Percutaneous edge-to-edge mitral valve (MV) repair is a relatively new treatment option for mitral regurgitation (MR). After the feasibility and safety having been proved in low-surgical-risk patients, the use of this procedure has shifted more to the treatment of high-risk patients. With the absence of randomized controlled trials (RCT) for this particular subgroup, observational studies try to add evidence to the safety aspect of this procedure. These also provide short- and mid-term mortality figures. Several mortality predictors have been identified, which may help the optimal selection of patients who will benefit most from this technique. In this article we provide an overview of the literature about mortality and its predictors in patients treated with the percutaneous edge-to-edge device.

18.
Catheter Cardiovasc Interv ; 87(3): 467-75, 2016 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-26268819

RESUMEN

OBJECTIVES: To evaluate long-term survival in high surgical risk patients undergoing percutaneous mitral valve repair (MVR) using the MitraClip(®) system and to identify preprocedural predictors of long-term mortality. BACKGROUND: Data for long-term survival and preprocedural predictors of mortality after percutaneous MVR in high surgical risk patients are sporadic. METHODS: From January 2009 to April 2013, 136 consecutive high surgical risk patients, with symptomatic moderate-to-severe or severe mitral regurgitation (MR), underwent percutaneous MVR using the MitraClip system. Cardiac and overall survival was determined at one and 2 years postprocedure. Univariate and multivariate analysis was performed to identify preprocedural predictors of long-term mortality. RESULTS: One year postprocedure, cardiac and overall survival was 86.7% and 84.6%, respectively and at 2 years cardiac and overall survival was 77.7% and 74.8%, respectively. In univariate analysis advanced age, lower body mass index, impaired renal function, elevated levels of log-N-terminal-pro-brain-natriuretic-peptide (log-NTproBNP), poor performance in functional tests (New York Heart Association (NYHA) class) and high logistic Euroscore (LES) and Society of Thoracic Surgeons (STS) score were identified as preprocedural predictors of long-term cardiac mortality. In multivariate analysis preoperative NYHA class III and IV, elevated levels of log-NTproBNP and advanced age predicted long-term cardiac mortality. CONCLUSIONS: Percutaneous MVR using the MitraClip system has favorable long-term survival rates in high surgical risk patients. Preprocedural NYHA functional class III and IV, elevated log-NTproBNP levels and advanced age predict higher long-term cardiac mortality and should be considered during patient selection.


Asunto(s)
Cateterismo Cardíaco/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Análisis Multivariante , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 86 Suppl 1: S28-33, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25754236

RESUMEN

AIMS: We sought to evaluate the procedural and clinical performances of the MGuard Prime Embolic Protection Stent (EPS) in a "real-world" population with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). METHODS AND RESULTS: Consecutive STEMI patients meeting the inclusion criteria and undergoing PPCI were enrolled. The primary endpoint was major adverse cardiac events (MACE) at 30 days, defined as the composite of cardiac death, myocardial infarction (Q wave and non-Q wave) or target lesion revascularization (PCI or coronary artery bypass graft). Secondary endpoints included device success, lesion success, and postprocedural reperfusion outcomes: thrombolysis in myocardial infarction (TIMI) flow and ST-segment elevation resolution (STR). A total of 97 patients (62 years, 77% men) were included. Symptom to cathlab time was 238 min. Device and lesion success were 100%. Final TIMI-3 flow was achieved in 91.8%, and STR > 50% in 87% of the patients. MACE at 30 days was 2.2%, which consisted of one case each of target vessel (TV)-myocardial infarction (MI), and non-TV-MI. CONCLUSIONS: The use of the MGuard Prime EPS stent is feasible and safe and could be also effective in achieving myocardial reperfusion in STEMI patients undergoing PPCI.


Asunto(s)
Electrocardiografía , Dispositivos de Protección Embólica , Embolia/prevención & control , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/métodos , Vigilancia de Productos Comercializados/métodos , Stents , Angiografía Coronaria , Estudios de Seguimiento , Humanos , Infarto del Miocardio/diagnóstico por imagen , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA