Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Neth Heart J ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39164507

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is considered a safe and effective alternative to surgical aortic valve replacement (SAVR) for elderly patients across the operative risk spectrum. In the Netherlands, TAVI is reimbursed only for patients with a high operative risk. Despite this, one fifth of TAVI patients are < 75 years of age. We aim to compare patient characteristics and outcomes of TAVI and SAVR patients < 75 years. METHODS: This study included all patients < 75 years without active endocarditis undergoing TAVI or SAVR for severe aortic stenosis, mixed aortic valve disease or degenerated aortic bioprosthesis between 2015 and 2020 at the Erasmus University Medical Centre. Dutch authority guidelines were used to classify operative risk. RESULTS: TAVI was performed in 292 patients, SAVR in 386 patients. Based on the Dutch risk algorithm, 59.6% of TAVI patients and 19.4% of SAVR patients were at high operative risk. There was no difference in 30-day all-cause mortality between TAVI and SAVR (2.4% vs 0.8%, p = 0.083). One-year and 5­year mortality was higher after TAVI than after SAVR (1-year: 12.5% vs 4.3%, p < 0.001; 5­year: 36.8% vs 12.0%, p < 0.001). Within risk categories we found no difference between treatment strategies. Independent predictors of mortality were cardiovascular comorbidities (left ventricular ejection fraction < 30%, atrial fibrillation, pulmonary hypertension) and the presence of malignancies, liver cirrhosis or immunomodulatory drug use. CONCLUSION: At the Erasmus University Medical Centre, in patients < 75 years, TAVI is selected for higher-risk phenotypes and overall has higher long-term mortality than SAVR. We found no evidence for worse outcome within risk categories.

2.
Am Heart J ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39121916

RESUMEN

BACKGROUND: About half of patients with severe aortic stenosis present with concomitant coronary artery disease. The optimal timing of percutaneous coronary intervention (PCI) and transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and concomitant coronary artery disease remains unknown. STUDY DESIGN: The TAVI PCI trial is a prospective, international, multicenter, randomized, two-arm, open-label study planning to enroll a total of 986 patients. It is designed to investigate whether the strategy "angiography-guided complete revascularization after (within 1-45 days) TAVI" is non-inferior to the strategy "angiography-guided complete revascularization before (within 1-45 days) TAVI" using the Edwards SAPIEN 3 or 3 Ultra Transcatheter Heart Valve™ in patients with severe aortic stenosis and concomitant coronary artery disease. Patients are randomized in a 1:1 ratio to one of the two treatment strategies. The primary end point is a composite of all-cause death, non-fatal myocardial infarction, ischemia-driven revascularization, rehospitalization (valve- or procedure-related including heart failure), or life-threatening/disabling or major bleeding at 1 year. CONCLUSIONS: The TAVI PCI trial tests the hypothesis that the strategy "PCI after TAVI" is non-inferior to the strategy "PCI before TAVI" in patients with severe aortic stenosis and concomitant coronary artery disease.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38970592

RESUMEN

Inter-echocardiography core laboratory (ECL) harmonization is pivotal to consider data from different ECLs interchangeable. On the basis of the experience of the first trans-Atlantic harmonization of 2 established ECLs in the field of transcatheter aortic valve replacement (TAVR) trials, this review describes the harmonized ECL methodology in analyzing and adjudicating the post-TAVR echocardiographic endpoints according to Valve Academic Research Consortium 3 definitions. This review presents the feasibility and intra- and inter-ECL reproducibility, explains the root cause of potential important inter-ECL variability, and formulates ECL recommendations for optimal post-TAVR echocardiographic image acquisition. The implementation of inter-ECL harmonization may further define the best practice of ECLs and have logistic and regulatory implications for the realization of future TAVR trials.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

6.
EuroIntervention ; 20(14): e865-e875, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007832

RESUMEN

BACKGROUND: Complete revascularisation is supported by recent trials in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease (MVD) without cardiogenic shock. However, the optimal timing of non-culprit lesion revascularisation is currently debated. AIMS: This prespecified analysis of the BioVasc trial aims to determine the effect of immediate complete revascularisation (ICR) compared to staged complete revascularisation (SCR) on clinical outcomes in patients with STEMI. METHODS: Patients presenting with STEMI and MVD were randomly assigned to ICR or SCR. The primary endpoint was the composite of all-cause mortality, myocardial infarction, any unplanned ischaemia-driven revascularisation, or cerebrovascular events at 1-year post-index procedure. RESULTS: Between June 2018 and October 2021, 608 (ICR: 305, SCR: 303) STEMI patients were enrolled. No significant differences between ICR and SCR were observed at 1-year follow-up in terms of the primary endpoint (7.0% vs 8.3%, hazard ratio [HR] 0.84, 95% confidence interval [CI]: 0.47-1.50; p=0.55): all-cause mortality (2.3% vs 1.3%, HR 1.77, 95% CI: 0.52-6.04; p=0.36), myocardial infarction (1.7% vs 3.3%, HR 0.50, 95% CI: 0.17-1.47; p=0.21), unplanned ischaemia-driven revascularisation (4.1% vs 5.0%, HR 0.80, 95% CI: 0.38-1.71; p=0.57) and cerebrovascular events (1.4% vs 1.3%, HR 1.01, 95% CI: 0.25-4.03; p=0.99). At 30-day follow-up, a trend towards a reduction of the primary endpoint in the ICR group was observed (ICR: 3.0% vs SCR: 6.0%, HR 0.50, 95% CI: 0.22-1.11; p=0.09). ICR was associated with a reduction in overall hospital stay (ICR: median 3 [interquartile range {IQR} 2-5] days vs SCR: median 4 [IQR 3-6] days; p<0.001). CONCLUSIONS: Clinical outcomes at 1 year were similar for STEMI patients who had undergone ICR and those who had undergone SCR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/terapia , Masculino , Femenino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Anciano , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Factores de Tiempo , Tiempo de Tratamiento , Revascularización Miocárdica/métodos
7.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986659

RESUMEN

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Femenino , Masculino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Readmisión del Paciente , Recuperación de la Función , Europa (Continente) , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Hemodinámica
8.
JAMA Cardiol ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985461

RESUMEN

Importance: In older patients with atrial fibrillation who take anticoagulants for stroke prevention, bleeding is increased compared with younger patients, thus, clinicians frequently prescribe lower than recommended doses in older patients despite limited randomized data. Objective: To evaluate ischemic and bleeding outcomes in patients 80 years and older with atrial fibrillation receiving edoxaban, 60 mg vs 30 mg, and edoxaban, 30 mg vs warfarin. Design, Setting, and Participants: The ENGAGE AF-TIMI 48 trial (Effective Anticoagulation With Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) was a parallel-design, double-blind, global clinical trial that randomized patients with atrial fibrillation to either one of 2 edoxaban dosing regimens or warfarin. This secondary analysis focused on patients 80 years or older without dose-reduction criteria receiving edoxaban, 60 mg vs 30 mg, as well as patients with or without dose-reduction criteria receiving edoxaban, 30 mg, vs warfarin. Study data were analyzed between October 2022 and December 2023. Interventions: Oral edoxaban, 30 mg once daily; edoxaban, 60 mg once daily; or warfarin. Main Outcomes and Measures: Primary net clinical outcome of death, stroke or systemic embolism, and major bleeding and each individual component. Results: The current analysis included 2966 patients 80 years and older (mean [SD] age, 83 [2.7] years; 1671 male [56%]). Among 1138 patients 80 years and older without dose-reduction criteria, those receiving edoxaban, 60 mg vs 30 mg, had more major bleeding events (hazard ratio [HR], 1.57; 95% CI, 1.04-2.38; P = .03), particularly gastrointestinal hemorrhage (HR, 2.24; 95% CI, 1.29-3.90; P = .004), with no significant difference in efficacy end points. Findings were supported by analyses of endogenous factor Xa inhibition, a marker of anticoagulant effect, which was comparable between younger patients receiving edoxaban, 60 mg, and older patients receiving edoxaban, 30 mg. In 2406 patients 80 years and older with or without dose-reduction criteria, patients receiving edoxaban, 30 mg, vs warfarin had lower rates of the primary net clinical outcome (HR, 0.78; 95% CI, 0.68-0.91; P = .001), major bleeding (HR, 0.59; 95% CI, 0.45-0.77; P < .001), and death (HR, 0.83; 95% CI, 0.70-1.00; P = .046), whereas rates of stroke or systemic embolism were comparable. Conclusions and Relevance: In this post hoc analysis of the ENGAGE AF-TIMI 48 randomized clinical trial, in patients 80 years and older with atrial fibrillation, major bleeding events were lower in patients randomized to receive edoxaban, 30 mg per day, compared with either edoxaban, 60 mg per day (in patients without dose-reduction criteria), or warfarin (irrespective of dose-reduction status), without an offsetting increase in ischemic events. These data support the concept that lower-dose anticoagulants, such as edoxaban, 30 mg, may be considered in older patients with atrial fibrillation even in the absence of dose-reduction criteria. Trial Registration: ClinicalTrials.gov Identifier: NCT00781391.

9.
Am J Cardiol ; 227: 98-104, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39032588

RESUMEN

In patients with prevalent or incident atrial fibrillation (AF) after successful transcatheter aortic valve implantation (TAVI) enrolled in the EdoxabaN Versus standard of care and theIr effectS on clinical outcomes in pAtients havinG undergonE Transcatheter Aortic Valve Implantation - in Atrial Fibrillation (ENVISAGE-TAVI AF) trial, the incidence of ischemic stroke (IS) and any stroke was numerically less in the edoxaban group than in the vitamin K antagonist (VKA) group. The present study aimed to identify risk factors associated with IS in an on-treatment subanalysis in patients from ENVISAGE-TAVI AF who received ≥1 dose of edoxaban or VKA. Baseline patient characteristics were compared in patients with and those without IS. Numerical variables were compared using a 1-way analysis of variance; categorical variables were compared using Fisher's exact test. Stepwise Cox regression determined patient characteristics associated with the first IS event. Of 1,377 patients, 41 (3.0%) experienced an IS, and 1,336 (97.0%) did not; baseline demographics and clinical characteristics were well balanced between groups. Most ISs occurred within 180 days of TAVI for edoxaban (57.9%) and VKA (68.2%). The rate of IS was 2.0/100 person-years for edoxaban versus 2.7/100 person-years for VKA. Independently associated with IS were history of systemic embolic events (hazard ratio 2.96, 95% confidence interval 1.26 to 7.00, p = 0.01) and pre-TAVI use of VKAs (hazard ratio 2.17, 95% confidence interval 1.12 to 4.20, p = 0.02). In conclusion, although the overall incidence of IS was small for patients with AF on edoxaban or VKA after successful TAVI, patients with a history of systemic embolic events or pre-TAVI use of VKAs may be at greater risk of IS after TAVI.

10.
Eur Heart J Case Rep ; 8(6): ytae291, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38938469

RESUMEN

Background: Left ventricular assist devices (LVADs) are increasingly utilized in cardiogenic shock and high-risk percutaneous coronary interventions (PCIs). These devices aspirate and expel blood from the left ventricle (LV) into the aorta, consequently reducing left ventricular end-diastolic pressure (LVEDP). We report a case of unexpected LVEDP rise under LV-to-aorta LVAD in the context of transcatheter aortic valve implantation (TAVI) and concomitant multi-vessel PCI. Case summary: A patient with acute heart failure, severely depressed systolic LV function, severe aortic stenosis, and multi-vessel coronary artery disease underwent TAVI and concomitant PCI under pulsatile LVAD. Notably, the patient experienced unexpected shortness of breath and elevated LVEDP while under LVAD, which normalized immediately upon LVAD removal. Discussion: Pulsatile LVAD enhances cardiac output by providing pulsatile support through a percutaneous bi-directional flow catheter. Despite expectations of reduced LVEDP and improved myocardial oxygen supply under LVAD support, we observed high LVEDP and clinical complaints of shortness of breath following TAVI and multi-vessel PCI. This case illustrates that an LVAD across the aortic valve may immobilize aortic leaflets and generate acute aortic regurgitation.

11.
J Clin Med ; 13(11)2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38892807

RESUMEN

Atherosclerosis is the predominant underlying etiopathology of coronary artery disease. Changes in plaque phenotype from stable to high risk may spur future major adverse cardiac events (MACE). Different pharmacological therapies have been implemented to mitigate this risk. Over the last two decades, intravascular imaging modalities have emerged in clinical studies to clarify how these therapies may affect the composition and burden of coronary plaques. Lipid-lowering agents, such as statins, ezetimibe, and proprotein convertase subtilisin/kexin type 9 inhibitors, were shown not only to reduce low-density lipoprotein levels and MACE but also to directly affect features of coronary plaque vulnerability. Studies have demonstrated that lipid-lowering therapy reduces the percentage of atheroma volume and number of macrophages and increases fibrous cap thickness. Future studies should answer the question of whether pharmacological plaque stabilization may be sufficient to mitigate the risk of MACE for selected groups of patients with atherosclerotic coronary disease.

12.
Eur J Heart Fail ; 26(8): 1736-1744, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38825743

RESUMEN

AIMS: Heart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms. METHODS: The BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death. CONCLUSION: Since the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively.


Asunto(s)
Biomarcadores , Insuficiencia Cardíaca , Arteria Pulmonar , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/sangre , Biomarcadores/sangre , Pronóstico , Arteria Pulmonar/fisiopatología , Femenino , Masculino , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Anciano , Presión Esfenoidal Pulmonar/fisiología , Enfermedad Crónica , Persona de Mediana Edad
13.
Eur Heart J Digit Health ; 5(3): 379-383, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38774368

RESUMEN

Aims: Invasive haemodynamic monitoring of heart failure (HF) is used to detect deterioration in an early phase thereby preventing hospitalizations. However, this invasive approach is costly and presently lacks widespread accessibility. Hence, there is a pressing need to identify an alternative non-invasive method that is reliable and more readily available. In this pilot study, we investigated the relation between wrist-derived photoplethysmography (PPG) signals and the invasively measured pulmonary capillary wedge pressure (PCWP). Methods and results: Fourteen patients with aortic valve stenosis who underwent transcatheter aortic valve replacement with concomitant right heart catheterization and PPG measurements were included. Six unique features of the PPG signals [heart rate, heart rate variability, systolic amplitude (SA), diastolic amplitude, crest time (CT), and large artery stiffness index (LASI)] were extracted. These features were used to estimate the continuous PCWP values and the categorized PCWP (low < 12 mmHg vs. high ≥ 12 mmHg). All PPG features resulted in regression models that showed low correlations with the invasively measured PCWP. Classification models resulted in higher performances: the model based on the SA and the model based on the LASI both resulted in an area under the curve (AUC) of 0.86 and the model based on the CT resulted in an AUC of 0.72. Conclusion: These results demonstrate the capability to non-invasively classify patients into clinically meaningful categories of PCWP using PPG signals from a wrist-worn wearable device. To enhance and fully explore its potential, the relationship between PPG and PCWP should be further investigated in a larger cohort of HF patients.

14.
ASAIO J ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38776488

RESUMEN

Patients undergoing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) typically suffer from cardiogenic pulmonary edema and lung atelectasis, which can exacerbate right ventricular (RV) dysfunction through an increase in lung elastance and RV afterload. Invasive mechanical ventilation settings, and positive end-expiratory pressure (PEEP) in particular, can help to improve RV performance by optimizing lung recruitment and minimizing alveolar overdistention. In this report, we present a VA-ECMO supported patient in whom in vivo RV pressure-volume (PV) loops were measured during a decremental PEEP trial, leading to the identification of an optimum PEEP level from a cardio-respiratory viewpoint. This innovative approach of tailoring mechanical ventilation settings according to cardio-respiratory physiology through in vivo RV PV loops may provide a novel way to optimize hemodynamics and patient outcomes.

15.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726720

RESUMEN

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Asunto(s)
Consenso , Hemorragia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Hemorragia/etiología , Medición de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
16.
Am J Cardiol ; 223: 73-80, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-38777210

RESUMEN

Recent trials suggested immediate complete revascularization (ICR) as a safe alternative to staged complete revascularization (SCR), but the impact of the respective percutaneous coronary intervention strategies between on- versus off-hours is unclear. On-hours was defined as an index revascularization performed between 8:00 a.m. and 6:00 p.m., Monday to Friday, or else the procedure was defined as performed during off-hours. The primary end point consisted of a composite of all-cause mortality, myocardial infarction, unplanned ischemia-driven revascularization, and cerebrovascular events at 1-year follow-up. We used Cox regression models to relate randomized treatment with study end points. We evaluated multiplicative and additive interactions between on- versus off-hours and randomized treatment. The BIOVASC (Percutaneous Complete Revascularization Strategies Using Sirolimus Eluting Biodegradable Polymer Coated Stents in Patients Presenting With Acute Coronary Syndromes and Multivessel Disease) trial enrolled 1,097 and 428 patients during on- and off-hours, respectively. Patients randomized during off-hours were more likely to present with ST-segment elevation myocardial infarction (66.4% vs 29.5%, p <0.001). The composite primary outcome occurred in 8.4% and 10.1% of patients randomized to ICR and SCR, respectively, during on-hours (hazard ratio 0.80, 95% confidence interval 0.54 to 1.19). During off-hours, the primary composite outcome occurred in 5.4% and 7.7% in ICR and SCR (0.69, 95% confidence interval 0.32 to 1.46) with no evidence of a differential effect (interaction pmultiplicative = 0.70, padditive = 0.56). No differential effect was found between treatment allocation and on- versus off-hours in any of the secondary outcomes. In conclusion, no differential treatment effect was found when comparing ICR versus SCR in patients presenting with acute coronary syndrome and multivessel disease during on- or off-hours.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Intervención Coronaria Percutánea/métodos , Persona de Mediana Edad , Anciano , Factores de Tiempo , Síndrome Coronario Agudo/cirugía , Síndrome Coronario Agudo/terapia , Infarto del Miocardio con Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/terapia , Revascularización Miocárdica/métodos , Revascularización Miocárdica/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento , Sirolimus/uso terapéutico , Estudios de Seguimiento
17.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38795109

RESUMEN

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Ecocardiografía de Estrés , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Curva ROC , Función Ventricular Izquierda , Área Bajo la Curva , Volumen Sistólico , Hemodinámica
18.
Eur Heart J ; 45(32): 2954-2964, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-38733175

RESUMEN

BACKGROUND AND AIMS: In patients with chronic heart failure (HF), the MONITOR-HF trial demonstrated the efficacy of pulmonary artery (PA)-guided HF therapy over standard of care in improving quality of life and reducing HF hospitalizations and mean PA pressure. This study aimed to evaluate the consistency of these benefits in relation to clinically relevant subgroups. METHODS: The effect of PA-guided HF therapy was evaluated in the MONITOR-HF trial among predefined subgroups based on age, sex, atrial fibrillation, diabetes mellitus, left ventricular ejection fraction, HF aetiology, cardiac resynchronization therapy, and implantable cardioverter defibrillator. Outcome measures were based upon significance in the main trial and included quality of life-, clinical-, and PA pressure endpoints, and were assessed for each subgroup. Differential effects in relation to the subgroups were assessed with interaction terms. Both unadjusted and multiple testing adjusted interaction terms were presented. RESULTS: The effects of PA monitoring on quality of life, clinical events, and PA pressure were consistent in the predefined subgroups, without any clinically relevant heterogeneity within or across all endpoint categories (all adjusted interaction P-values were non-significant). In the unadjusted analysis of the primary endpoint quality-of-life change, weak trends towards a less pronounced effect in older patients (Pinteraction = .03; adjusted Pinteraction = .33) and diabetics (Pinteraction = .01; adjusted Pinteraction = .06) were observed. However, these interaction effects did not persist after adjusting for multiple testing. CONCLUSIONS: This subgroup analysis confirmed the consistent benefits of PA-guided HF therapy observed in the MONITOR-HF trial across clinically relevant subgroups, highlighting its efficacy in improving quality of life, clinical, and PA pressure endpoints in chronic HF patients.


Asunto(s)
Insuficiencia Cardíaca , Arteria Pulmonar , Calidad de Vida , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Femenino , Masculino , Anciano , Persona de Mediana Edad , Arteria Pulmonar/fisiopatología , Enfermedad Crónica , Volumen Sistólico/fisiología , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables
19.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38569793

RESUMEN

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías , Humanos , Valor Predictivo de las Pruebas , Procedimientos Quirúrgicos Cardíacos/métodos , Simulación por Computador , Cardiopatías/diagnóstico por imagen , Cardiopatías/terapia , Programas Informáticos , Impresión Tridimensional
20.
EuroIntervention ; 20(8): e479-e486, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38629415

RESUMEN

BACKGROUND: In patients presenting with acute coronary syndrome (ACS), the number of diseased vessels may affect the efficacy of a complete revascularisation strategy. AIMS: The authors sought to evaluate the safety and efficacy of immediate complete revascularisation (ICR) and staged complete revascularisation (SCR) in patients presenting with ACS stratified by the number of diseased vessels. METHODS: In this prespecified analysis of the BIOVASC trial, ICR was compared with SCR in patients with two-vessel disease (2VD) or three-vessel disease (3VD). The primary endpoint was a composite of all-cause mortality, myocardial infarction (MI), any unplanned ischaemia-driven revascularisation or cerebrovascular events at 1 year after the index procedure. Comparisons were performed using Cox regression. RESULTS: A total of 1,525 patients were enrolled in the BIOVASC trial, of whom 1,177 presented with 2VD and 265 with 3VD. In the 2VD group, 613 patients were assigned to ICR and 564 to SCR. In the 3VD group, 117 patients were assigned to ICR and 148 to SCR. ICR and SCR led to similar results in both the 2VD (hazard ratio [HR] 0.76, 95% confidence interval [CI]: 0.50-1.13; p=0.18) and 3VD groups (HR 0.79, 95% CI: 0.39-1.59; p=0.51) (pinteraction=0.91) in terms of the primary endpoint. ICR was associated with a lower rate of MI in patients with 3VD (HR 0.21, 95% CI: 0.046-0.93; p=0.04) (pinteraction=0.30). CONCLUSIONS: ICR might be an option in patients presenting with extensive 3VD and might be associated with a lower rate of myocardial infarction compared with SCR.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Síndrome Coronario Agudo/cirugía , Resultado del Tratamiento , Puente de Arteria Coronaria/métodos , Procedimientos Quirúrgicos Vasculares , Intervención Coronaria Percutánea/métodos , Enfermedad de la Arteria Coronaria/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...