Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Methods Mol Biol ; 2271: 57-71, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33907999

RESUMEN

Immunoglobulins G (IgG) are proteins produced by the immune system of higher life forms that play a central role in the defense against microbial pathogens. IgG bind pathogens with the hypervariable Fab component and mediate a diversity of effector functions by binding to immune effector cells via their crystallizable (Fc) component. All IgG Fc carry a polymorphic N-glycan that regulates its binding properties and thereby its effector functions. The glycosylation profile of IgG Fc is modulated by physiological and pathological conditions, including infectious diseases and inflammatory disorders. Characterization of IgG Fc glycosylation profiles is a promising approach to understand the pathogenesis of diseases involving the immune system and to develop novel biomarkers of disease activity. Measuring the proportion of the different IgG Fc glycoforms remains an analytical challenge, that requires a sensitive and reproducible analytical approach.This chapter describes an optimized approach for the preparation and the analysis of Fc N-glycans from total serum or plasma IgG using magnetic beads, RapiFluor MS label©, and LC-MS.


Asunto(s)
Cromatografía Liquida , Fragmentos Fc de Inmunoglobulinas/sangre , Inmunoglobulina G/sangre , Procesamiento Proteico-Postraduccional , Espectrometría de Masa por Ionización de Electrospray , Animales , Glicosilación , Humanos , Proyectos de Investigación , Flujo de Trabajo
2.
Artículo en Inglés | MEDLINE | ID: mdl-30642937

RESUMEN

Accumulating evidence suggests that the bactericidal activity of some antibiotics may not be directly initiated by target inhibition. The activity of isoniazid (INH), a key first-line bactericidal antituberculosis drug currently known to inhibit mycolic acid synthesis, becomes extremely poor under stress conditions, such as hypoxia and starvation. This suggests that the target inhibition may not fully explain the bactericidal activity of the drug. Here, we report that INH rapidly increased Mycobacterium bovis BCG cellular ATP levels and enhanced oxygen consumption. The INH-triggered ATP increase and bactericidal activity were strongly compromised by Q203 and bedaquiline, which inhibit mycobacterial cytochrome bc1 and FoF1 ATP synthase, respectively. Moreover, the antioxidant N-acetylcysteine (NAC) but not 4-hydroxy-2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPOL) abrogated the INH-triggered ATP increase and killing. These results reveal a link between the energetic (ATP) perturbation and INH's killing. Furthermore, the INH-induced energetic perturbation and killing were also abrogated by chemical inhibition of NADH dehydrogenases (NDHs) and succinate dehydrogenases (SDHs), linking INH's bactericidal activity further to the electron transport chain (ETC) perturbation. This notion was also supported by the observation that INH dissipated mycobacterial membrane potential. Importantly, inhibition of cytochrome bd oxidase significantly reduced cell recovery during INH challenge in a culture settling model, suggesting that the respiratory reprogramming to the cytochrome bd oxidase contributes to the escape of INH killing. This study implicates mycobacterial ETC perturbation through NDHs, SDHs, cytochrome bc1, and FoF1 ATP synthase in INH's bactericidal activity and pinpoints the participation of the cytochrome bd oxidase in protection against this drug under stress conditions.


Asunto(s)
Antituberculosos/farmacología , Proteínas del Complejo de Cadena de Transporte de Electrón/antagonistas & inhibidores , Transporte de Electrón/efectos de los fármacos , Isoniazida/farmacología , Mycobacterium bovis/efectos de los fármacos , Mycobacterium tuberculosis/efectos de los fármacos , Adenosina Trifosfato/metabolismo , Grupo Citocromo b/antagonistas & inhibidores , Diarilquinolinas/farmacología , Complejo IV de Transporte de Electrones/metabolismo , Imidazoles/farmacología , Potenciales de la Membrana/efectos de los fármacos , Mycobacterium bovis/metabolismo , Mycobacterium tuberculosis/metabolismo , Oxidación-Reducción/efectos de los fármacos , Consumo de Oxígeno/efectos de los fármacos , Piperidinas/farmacología , Piridinas/farmacología
3.
Talanta ; 177: 157-162, 2018 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-29108570

RESUMEN

Ethoxyquin (EQ) is widely used as a synthetic antioxidant in animal feed, an antiscalding agent in apples and pears and as a color preservative in some spices. Since the presence of EQ in food products could cause negative health effects it is necessary to develop reliable analytical methods to evaluate the risk of human exposure. In this work, a sensitive, selective and accurate method based on solid-liquid extraction followed by clean-up with solid sorbent and liquid chromatography-electrochemical detection analysis with boron doped diamond electrode (LC-EC) for the determination of ethoxyquin and its dimer (EQDM) in pear skin and salmon samples, was developed. The method was validated according to the European Commission guidelines. The main variables of extraction were accurately optimized. The amounts of solid sorbents for clean-up procedure were optimized by using experimental design. A Box-Behnken design to obtain the optimum conditions was applied. For validation, a matrix-matched calibration was established and a recovery assay with spiked samples was carried out. The limits of detection (LODs) found were 0.05 and 0.1mgkg-1 for EQ and its dimer, respectively. The precision (as relative standard deviation, RSD) was lower than 15% with recoveries of compounds close to 100% in spiked samples.


Asunto(s)
Etoxiquina/análisis , Análisis de los Alimentos/métodos , Contaminación de Alimentos/análisis , Pyrus/química , Salmón , Animales , Cromatografía Liquida , Electroquímica , Etoxiquina/química , Límite de Detección , Alimentos Marinos/análisis , Solventes/química
4.
Curr Med Chem ; 25(33): 4050-4065, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28595548

RESUMEN

Liquid chromatography (LC) coupled to an electrochemical (EC) detector is a complementary analytical tool compared to LC coupled with optical or mass spectrometry detectors (LC-MS). LC-EC can be applied to the determination of molecules difficult to be analyzed by other commercially available detectors. New EC detector design and new working electrode material have extended the scope of application in the field of pharmaceutical compounds analysis. Combining EC with LC-MS offers additional advantages compared to optical detectors in terms of drug stability and drug metabolism mimicry studies. Selected literature devoted to pharmacologically active compounds in their dosage forms, herbal drugs in natural products, drug residues in feed and/or in biological samples are reported in this review.


Asunto(s)
Cromatografía Liquida/instrumentación , Técnicas Electroquímicas/instrumentación , Preparaciones Farmacéuticas/análisis , Electrodos , Espectrometría de Masas/métodos , Preparaciones Farmacéuticas/metabolismo
5.
Curr Drug Deliv ; 13(3): 371-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26521653

RESUMEN

All analytical techniques have experienced major progress since the last ten years and electroanalysis is also involved in this trend. The unique characteristics of phenomena occurring at the electrode-solution interface along with the variety of electrochemical methods currently available allow for a broad spectrum of applications. Potentiometric, conductometric, voltammetric and amperometric methods are briefly reviewed with a critical view in terms of performance of the developed instrumentation with special emphasis on pharmaceutical and biomedical applications.


Asunto(s)
Técnicas de Química Analítica , Técnicas Electroquímicas , Investigación Biomédica , Electroquímica , Farmacia
6.
Biosens Bioelectron ; 77: 457-63, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26454827

RESUMEN

An immunoassay for the determination of anti-tetani antibodies has been developed using a screen printed electrode (SPE) as solid support for toxoid (antigen) immobilization. The assay was performed in guinea pig serum. The immunoreaction and the subsequent amperometric detection occurred directly onto the SPE surface. The assay consisted of spiking the anti-tetani sample directly onto the toxoid modified SPE, and then a second antibody, i.e. a HRP-labeled anti-immunoglobulin G, was deposited onto the biosensor. Subsequent amperometric detection was realized by spiking 10 µL of a hydroquinone (HQ) solution into 40 µL of buffer solution containing hydrogen peroxide. An experimental design approach was implemented for the optimization of the immunoassay. The variables of interest, such as bovine serum albumin (BSA) concentration, incubation times and labeled antibody dilution, were optimized with the aid of the response surface methodology using a circumscribed central composite design (CCCD). It was observed that two factors exhibited the greatest impact on the response, i.e. the anti-tetani incubation time and the dilution factor of the labeled antibody. It was discovered that in order to maximize the response, the dilution factor should be small, while the anti-tetani antibody incubation time should be long. The BSA concentration and the HRP-anti-IgG incubation had very limited influence. Under the optimized conditions, the immunoassay had a limit of detection of 0.011 IU/mL and a limit of quantification of 0.012 IU/mL. These values were below the protective human antibody limit of 0.06 IU/mL.


Asunto(s)
Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Clostridium tetani/inmunología , Conductometría/instrumentación , Electrodos , Inmunoensayo/instrumentación , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Cobayas , Fotograbar/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Anal Chem ; 87(13): 6730-5, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-26024436

RESUMEN

A silver amperometric detector coupled to liquid chromatography (LC) was used for the determination of 6-thioguanine (6-TG) and two of its metabolites, thiouric acid (TU) and 2-amino-6-mercaptopurine riboside (6-TGR). The silver detector coupled to LC operated at a low applied potential (0.08 V vs Ag/AgCl) and offered a chromatogram with peak responses corresponding to molecules interacting with silver, namely, chloride ions and small soluble biothiols in addition to the organothiol drug compounds investigated. Online electrochemical surface cleaning permitted the improvement of the repeatability and peak shape of the recorded signal compared to direct current amperometric detection (AD) when operating in chloride containing media. The studied molecules were eluted isocratically within 5 min on a reversed-phase C18 column without interference from endogenous biothiols present in urine samples. Diluted urine samples (1:1) were directly injected in the LC setup; a linear calibration curve was obtained between peak area and analyte concentration between 0.1 and 10 µM for all the studied molecules. Limits of detection (LODs) were 0.03, 0.008, and 0.01 µM, and the limits of quantification (LOQs) were 0.1, 0.02, and 0.03 µM for TU, 6-TG, and 6-TGR, respectively. Within-day RSDs were 2%, 0.8%, and 1% and between-day RSDs were 2%, 0.9%, 2% for TU, 6-TG, and 6-TGR, respectively. Recoveries in spiked urine were 99.8%, 99.9%, and 99.0% for TU, 6-TG, and 6-TGR, respectively.


Asunto(s)
Cromatografía Liquida/métodos , Técnicas Electroquímicas/métodos , Purinas/orina , Plata/química , Compuestos de Sulfhidrilo/análisis
8.
J Pharm Biomed Anal ; 102: 267-75, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25459923

RESUMEN

A commercially available thin-layer flow-through amperometric detector, with the sensing block customized in an original design, was applied to the screening of drug compounds known as acetylcholinesterase (AChE) inhibitors. AChE from electric eel was covalently immobilized onto a cysteamine modified gold disk adjacent to a silver disk working electrode. On-line studies were performed by flow injection analysis (FIA) in PBS buffer pH 7.4. Seven commercially available AChE inhibitors used in the medical field, namely neostigmine, eserine, tacrine, donepezil, rivastigmine, pyridostigmine and galantamine as well as two natural compounds, quercetin and berberine, were investigated. The same trend of inhibitory potency as described in the literature was observed. Of particular interest and in addition to the determination of the IC50 values, this flow-through system allowed the study of both, the stability of the enzyme-inhibitor complex and the kinetic of the enzyme activity recovery.


Asunto(s)
Inhibidores de la Colinesterasa/análisis , Técnicas Electroquímicas/instrumentación , Enzimas Inmovilizadas/química , Análisis de Inyección de Flujo/métodos , Electrodos , Concentración de Iones de Hidrógeno , Reproducibilidad de los Resultados , Factores de Tiempo
9.
Talanta ; 130: 164-70, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25159394

RESUMEN

A chip format sandwich-type immunoassay based on Nanobodies(®) (Nbs) with the Human Epidermal Growth Factor Receptor (HER2) extracellular domain as antigen model has been developed. The HER2 is considered as an important biomarker because its overexpression causes an aggressive type of breast cancer. Nbs are single domain antigen-binding fragments derived from camelid heavy-chain antibodies. The strategy of the presently developed sandwich immunoassay takes advantage of the small size of Nbs for the detection of the electroactive redox tracer onto the screen printed electrode (SPE). A capture anti HER2 Nb was covalently immobilized onto the SPE, and the detection Nb, raised against another epitope of HER2, was labeled with horseradish peroxidase (HRP). The biosensor signal corresponded to the electroreduction of para-quinone generated at the SPE by the HRP in the presence of hydroquinone and hydrogen peroxide. The best performing and optimized immunoassay conditions consisted of 2 and 20 min for the first and the second incubation times, respectively. The amperometric signal obtained was proportional to the logarithm of HER2 concentration between 1 and 200 µg/mL and the modified SPE storage stability lasted for at least three weeks. Determination of HER2 in human cells has been realized.


Asunto(s)
Biomarcadores de Tumor/análisis , Técnicas Biosensibles , Neoplasias de la Mama/diagnóstico , Electrodos , Inmunoensayo/métodos , Receptor ErbB-2/análisis , Anticuerpos de Dominio Único/química , Neoplasias de la Mama/metabolismo , Electroquímica , Electroforesis en Gel de Poliacrilamida , Femenino , Peroxidasa de Rábano Silvestre/metabolismo , Humanos , Peróxido de Hidrógeno/química , Células MCF-7 , Nanotecnología , Receptor ErbB-2/química , Resonancia por Plasmón de Superficie
SELECCIÓN DE REFERENCIAS