Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Am J Perinatol ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714205

RESUMEN

OBJECTIVE: This study aimed to assess the viability of implementing a tele-educational training program in neurocritical care for newborns diagnosed with hypoxic-ischemic encephalopathy (HIE) and treated with therapeutic hypothermia (TH), with the goal of reducing practice variation. STUDY DESIGN: Prospective study including newborns with HIE treated with TH from 12 neonatal intensive care units in Brazil conducted from February 2021 to February 2022. An educational intervention consisting of 12 biweekly, 1-hour, live videoconferences was implemented during a 6-month period in all centers. Half of the centers had the assistance of a remote neuromonitoring team. The primary outcome was the rate of deviations from TH protocol, and it was evaluated during a 3-month period before and after the intervention. Logistic regression via generalized estimating equations was performed to compare the primary and secondary outcomes. Protocol deviations were defined as practices not in compliance with the TH protocol provided. A subanalysis evaluated the differences in protocol deviations and clinical variables between centers with and without neuromonitoring. RESULTS: Sixty-six (39.5%) newborns with HIE were treated with TH during the preintervention period, 69 (41.3%) during the intervention period and 32 (19.1%) after intervention. There was not a significant reduction in protocol deviations between the pre- and postintervention periods (37.8 vs. 25%, p = 0.23); however, a decrease in the rates of missing Sarnat examinations within 6 hours after birth was seen between the preintervention (n = 5, 7.6%) and postintervention (n = 2, 6.3%) periods (adjusted odds ratio [aOR]: 0.36 [0.25-0.52], p < 0.001). Centers with remote neuromonitoring support had significantly lower rates of seizures (27.6 vs. 57.5%; aOR: 0.26 [0.12-0.55], p < 0.001) and significant less seizure medication (27.6 vs. 68.7%; aOR: 0.17 [0.07-0.4], p < 0.001). CONCLUSION: This study shows that implementing a tele-educational program in neonatal neurocritical care is feasible and may decrease variability in the delivery of care to patients with HIE treated with TH. KEY POINTS: · Neurocritical care strategies vary widely in low- and middle-income countries.. · Heterogeneity of care may lead to suboptimal efficacy of neuroprotective strategies.. · Tele-education and international collaboration can decrease the variability of neurocritical care provided to infants with HIE..

2.
Pediatr Res ; 94(5): 1810-1816, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37391490

RESUMEN

BACKGROUND: The majority of neonatal NIRS literature recommends target ranges for cerebral saturation (rScO2) based on data using adult sensors. Neonatal sensors are now commonly used in the neonatal intensive care unit (NICU). However, there is limited clinical data correlating these two measurements of cerebral oxygenation. METHODS: A prospective observational study was conducted in two NICUs between November 2019 and May 2021. An adult sensor was placed on infants undergoing routine cerebral NIRS monitoring with a neonatal sensor. Time-synchronized rScO2 measurements from both sensors, heart rate, and systemic oxygen saturation values were collected over 6 h under varying clinical conditions and compared. RESULTS: Time-series data from 44 infants demonstrated higher rScO2 measurements with neonatal sensors than with adult sensors; however, the magnitude of the difference varied depending on the absolute value of rScO2 (Adult = 0.63 × Neonatal + 18.2). While there was an approximately 10% difference when adult sensors read 85%, readings were similar when adult sensors read 55%. CONCLUSION: rScO2 measured by neonatal sensors is typically higher than measured by adult sensors, but the difference is not fixed and is less at the threshold indicative of cerebral hypoxia. Assuming fixed differences between adult and neonatal sensors may lead to overdiagnosis of cerebral hypoxia. IMPACT: In comparison to adult sensors, neonatal sensors rScO2 readings are consistently higher, but the magnitude of the difference varies depending on the absolute value of rScO2. Marked variability during high and low rScO2 readings was noted, with approximately 10% difference when adult sensors read 85%, but nearly similar (58.8%) readings when adult sensors read 55%. Estimating fixed differences of approximately 10% between adult and neonatal probes may lead to an inaccurate diagnosis of cerebral hypoxia and result in subsequent unnecessary interventions.


Asunto(s)
Hipoxia Encefálica , Oxígeno , Recién Nacido , Lactante , Humanos , Adulto , Saturación de Oxígeno , Unidades de Cuidado Intensivo Neonatal , Espectroscopía Infrarroja Corta
3.
Front Pediatr ; 11: 1111347, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37187586

RESUMEN

Continuous neuromonitoring in the neonatal intensive care unit allows for bedside assessment of brain oxygenation and perfusion as well as cerebral function and seizure identification. Near-infrared spectroscopy (NIRS) reflects the balance between oxygen delivery and consumption, and use of multisite monitoring of regional oxygenation provides organ-specific assessment of perfusion. With understanding of the underlying principles of NIRS as well as the physiologic factors which impact oxygenation and perfusion of the brain, kidneys and bowel, changes in neonatal physiology can be more easily recognized by bedside providers, allowing for appropriate, targeted interventions. Amplitude-integrated electroencephalography (aEEG) allows continuous bedside evaluation of cerebral background activity patterns indicative of the level of cerebral function as well as identification of seizure activity. Normal background patterns are reassuring while abnormal background patterns indicate abnormal brain function. Combining brain monitoring information together with continuous vital sign monitoring (blood pressure, pulse oximetry, heart rate and temperature) at the bedside may be described as multi-modality monitoring and facilitates understanding of physiology. We describe 10 cases in critically ill neonates that demonstrate how comprehensive multimodal monitoring provided greater recognition of the hemodynamic status and its impact on cerebral oxygenation and cerebral function thereby informing treatment decisions. We anticipate that there are numerous other uses of NIRS as well as NIRS in conjunction with aEEG which are yet to be reported.

4.
Arch Dis Child Fetal Neonatal Ed ; 108(2): 96-101, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35732482

RESUMEN

As the approach to the patent ductus arteriosus (PDA) in the preterm infant remains controversial, the potential consequences of a significant ductal shunt on the brain should be evaluated. In this population at high risk of adverse outcomes, including intraventricular haemorrhage and white matter injury, as well as longer-term neurodevelopmental impairment, it is challenging to attribute sequelae to the PDA. Moreover, individual patient characteristics including gestational age and timing of PDA intervention factor into risks of brain injury. Haemodynamic assessment of the ductus combined with bedside neuromonitoring techniques improve our understanding of the role of the PDA in neurological injury. Effects of various PDA management strategies on the brain can similarly be investigated. This review incorporates current understanding of how the PDA impacts the developing brain of preterm infants and examines modalities to measure these effects.


Asunto(s)
Lesiones Encefálicas , Conducto Arterioso Permeable , Conducto Arterial , Lactante , Recién Nacido , Humanos , Recien Nacido Prematuro , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/diagnóstico por imagen , Edad Gestacional , Encéfalo/diagnóstico por imagen
5.
Anaerobe ; 61: 102134, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31838318

RESUMEN

The most commonly identified pathogens related to bacterial meningitis are group B streptococcus and gram-negative enteric flora; anaerobic sepsis and meningitis are very rare. We report a case on a preterm and extremely low-birth weight infant who developed meningitis caused by Bacteroides fragilis and his mother who had postpartum sepsis also caused by the same agent.


Asunto(s)
Bacterias Anaerobias , Bacteroides fragilis , Meningitis Bacterianas/diagnóstico , Meningitis Bacterianas/microbiología , Adulto , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Bacteroides fragilis/efectos de los fármacos , Biomarcadores , Femenino , Humanos , Recién Nacido , Meningitis Bacterianas/complicaciones , Meningitis Bacterianas/tratamiento farmacológico , Pruebas de Sensibilidad Microbiana , Evaluación de Síntomas , Resultado del Tratamiento
6.
J Matern Fetal Neonatal Med ; 33(10): 1802-1810, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-30244630

RESUMEN

Near-infrared spectroscopy (NIRS) monitoring provides a noninvasive, bedside measure of cerebral and somatic oxygenation in neonates at risk for hemodynamic instability and brain injury. This technology has been increasingly utilized in the neonatal intensive care unit, however, clinicians perceive a lack of evidence for the added value of NIRS monitoring. We present six clinical scenarios illustrating the value of NIRS monitoring for the diagnosis and management of critically ill newborns.


Asunto(s)
Lesiones Encefálicas/diagnóstico por imagen , Circulación Cerebrovascular , Monitorización Hemodinámica/métodos , Espectroscopía Infrarroja Corta/métodos , Femenino , Humanos , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...