Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Semin Arthritis Rheum ; 66: 152437, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38564998

RESUMEN

Inter-reader reliability of a new scoring system for evaluating joint inflammation and enthesitis in whole body MRI (WBMRI) in juvenile idiopathic arthritis was tested. The scoring system grades 732 item-region combinations of bone marrow and soft tissue changes for commonly involved joints and entheseal sites. Five radiologists rated 17 WBMRI scans through an online rating platform. Item-wise reliability was calculated for 117 items with non-zero scores in >10 % of readings. Interquartile ranges of the five-reader Kappa reliability coefficients were 0.58-0.73 (range: 0.36-0.88) for the joints, 0.65-0.81 (range: 0.39-0.95) for the entheses, and 0.62-0.75 (range: 0.60-0.76) for chronic nonbacterial osteomyelitis-like lesions.


Asunto(s)
Artritis Juvenil , Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Humanos , Artritis Juvenil/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Niño , Imagen de Cuerpo Entero/métodos , Masculino , Índice de Severidad de la Enfermedad , Femenino , Adolescente , Articulaciones/diagnóstico por imagen , Preescolar
2.
Semin Arthritis Rheum ; 64: 152299, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38039747

RESUMEN

OBJECTIVE: To determine whether systematic calibration enhances scoring proficiency of the OMERACT juvenile idiopathic arthritis MRI-Sacroiliac Joint score (JAMRIS-SIJ) and whether contrast-enhancement enhances its performance. METHODS: MRI SIJ scans of 50 cases with juvenile spondyloarthritis were scored by 7 raters after calibration with 3 different knowledge transfer tools. RESULTS: Calibrated readers achieved greater reliability for scoring certain inflammatory and structural lesions. Sensitivity and reliability for scoring inflammatory lesions was greater on fluid-sensitive compared to contrast-enhanced sequences. CONCLUSION: Systematic calibration should be implemented prior to the use of JAMRIS-SIJ for clinical trials. It is unlikely that contrast-enhanced MRI will improve the performance of this method.


Asunto(s)
Artritis Juvenil , Articulación Sacroiliaca , Humanos , Articulación Sacroiliaca/diagnóstico por imagen , Artritis Juvenil/diagnóstico por imagen , Reproducibilidad de los Resultados , Calibración , Imagen por Resonancia Magnética/métodos
3.
J Med Imaging Radiat Oncol ; 68(2): 141-149, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38146085

RESUMEN

INTRODUCTION: To compare diagnostic accuracy of contrast-enhanced mammography (CEM) with standard 2D digital mammography (equivalent to low-energy image; LEM) for detection of multifocal and multicentric breast cancer and evaluation of tumour size and disease extent for preoperative planning. METHODS: Biopsy proven breast cancer patients who underwent CEM preoperatively between January 2021 and January 2023 were included in this study. CEM and LEM images were independently reviewed by at least two blinded readers. Lesion location, number, size (maximal diameter) and extension across the midline and/or nipple invasion were recorded. Tumour number and size estimated on imaging were compared with final operative histology, which served as the gold standard. RESULTS: Forty-nine patients (48 females and 1 male) and 50 cases (one patient had bilateral breast lesions) were included in the analysis. Median patient age was 60 (IQR 51, 69). CEM had significantly higher lesion detection rate compared with LEM, with sensitivities of 78% for LEM and 92% for CEM for the index tumour and 15% for LEM and 100% for CEM for multicentric and multifocal cancer. We found no statistically significant difference in median tumour size measurements on CEM and final surgical specimen (P value = 0.97); however, a significant difference was identified in the tumour size measured on LEM and surgical specimen (P value < 0.001). CONCLUSION: CEM is superior to standard 2D digital mammography for detection of multifocal and multicentric breast cancer and is a reliable and more accurate method for estimating tumour size.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Masculino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mamografía/métodos , Mama/patología , Medios de Contraste , Imagen por Resonancia Magnética
4.
Neuromuscul Disord ; 33(1): 15-23, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36522253

RESUMEN

Symptoms and severity of facioscapulohumeral muscular dystrophy (FSHD) can vary greatly, even within the same family. Clinical trial readiness requires accurate and reliable methods of assessing disease stage and progression. MRI has not previously been assessed as a disease biomarker in paediatric FSHD. Eleven patients with FSHD1 underwent whole body muscle MRI. Pre-selected muscles were analysed by a paediatric radiologist using the semi-quantitative Mercuri/Kim method. Within each domain (oedema, fat replacement, atrophy) scores for each muscle were then summated to give each participant three cumulative domain scores. The same participants had functional measures scored: FSHD-CSS (Ricci), FSHD-CS (Lamperti), FSHD-COM, PUL2.0, MFM-32, 6MWT, myometry and manual muscle testing. Pearson coefficient was calculated to determine strength of correlation. The scores for atrophy and fat replacement showed strong correlation with functional outcome measures, particularly FSHD-CSS, FSHD-CS and FSHD-COM. In contrast, muscle oedema correlated poorly with all functional outcome measures, with no relationship seen to the 6MWT. This study of eleven children suggests that semi-quantitative visual Mercuri score utilising fat replacement or atrophy on whole body muscle MRI correlates strongly with disease-specific functional measures and may be a useful measure of disease severity in paediatric FSHD.


Asunto(s)
Distrofia Muscular Facioescapulohumeral , Humanos , Niño , Distrofia Muscular Facioescapulohumeral/diagnóstico por imagen , Músculo Esquelético/patología , Imagen por Resonancia Magnética/métodos , Atrofia , Edema/patología
5.
Epilepsy Behav ; 10(2): 250-4, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17218155

RESUMEN

We examined current employment status, reasons for unemployment, and related psychosocial concerns of 202 persons with epilepsy from the south Indian state of Kerala. Compared with 19% of the general population, 58% of persons with epilepsy were unemployed. Seizure remission for > or = 2 years, monotherapy, better education, ability to travel alone, and ability to drive were significantly associated with being employed. More than three-fourths of the persons with epilepsy had disclosed their epilepsy to their employers and co-workers, which did not adversely affect employment for the majority. The unemployed perceived fear of having seizures and seizure-related falls in the workplace, inadequate education, and antiepileptic drug-induced fatigue as reasons for unemployment. We conclude that unemployment is a major concern of people with epilepsy in this developing region. In addition to optimum seizure control, persons with epilepsy need support in job seeking, in reducing fear of seizures and falls in the workplace, and in identifying their individual abilities and limitations.


Asunto(s)
Empleo/estadística & datos numéricos , Epilepsia/epidemiología , Adolescente , Adulto , Factores de Edad , Anticonvulsivantes/uso terapéutico , Actitud , Conducción de Automóvil , Recolección de Datos , Epilepsia/clasificación , Femenino , Humanos , India/epidemiología , Masculino , Persona de Mediana Edad , Factores Sexuales , Factores Socioeconómicos , Desempleo/estadística & datos numéricos , Lugar de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...