Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
AJR Am J Roentgenol ; 220(1): 73-85, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35731096

RESUMEN

BACKGROUND. Anatomic redundancy between phases can be used to achieve denoising of multiphase CT examinations. A limitation of iterative reconstruction (IR) techniques is that they generally require use of CT projection data. A frequency-split multi-band-filtration algorithm applies denoising to the multiphase CT images themselves. This method does not require knowledge of the acquisition process or integration into the reconstruction system of the scanner, and it can be implemented as a supplement to commercially available IR algorithms. OBJECTIVE. The purpose of the present study is to compare radiologists' performance for low-contrast and high-contrast diagnostic tasks (i.e., tasks for which differences in CT attenuation between the imaging target and its anatomic background are subtle or large, respectively) evaluated on multiphase abdominal CT between routine-dose images and radiation dose-reduced images processed by a frequency-split multiband-filtration denoising algorithm. METHODS. This retrospective single-center study included 47 patients who underwent multiphase contrast-enhanced CT for known or suspected liver metastases (a low-contrast task) and 45 patients who underwent multiphase contrast-enhanced CT for pancreatic cancer staging (a high-contrast task). Radiation dose-reduced images corresponding to dose reduction of 50% or more were created using a validated noise insertion technique and then underwent denoising using the frequency-split multi-band-filtration algorithm. Images were independently evaluated in multiple sessions by different groups of abdominal radiologists for each task (three readers in the low-contrast arm and four readers in the high-contrast arm). The noninferiority of denoised radiation dose-reduced images to routine-dose images was assessed using the jackknife alternative free-response ROC (JAFROC) figure-of-merit (FOM; limit of noninferiority, -0.10) for liver metastases detection and using the Cohen kappa statistic and reader confidence scores (100-point scale) for pancreatic cancer vascular invasion. RESULTS. For liver metastases detection, the JAFROC FOM for denoised radiation dose-reduced images was 0.644 (95% CI, 0.510-0.778), and that for routine-dose images was 0.668 (95% CI, 0.543-0.792; estimated difference, -0.024 [95% CI, -0.084 to 0.037]). Intraobserver agreement for pancreatic cancer vascular invasion was substantial to near perfect when the two image sets were compared (κ = 0.53-1.00); the 95% CIs of all differences in confidence scores between image sets contained zero. CONCLUSION. Multiphase contrast-enhanced abdominal CT images with a radiation dose reduction of 50% or greater that undergo denoising by a frequency-split multiband-filtration algorithm yield performance similar to that of routine-dose images for detection of liver metastases and vascular staging of pancreatic cancer. CLINICAL IMPACT. The image-based denoising algorithm facilitates radiation dose reduction of multiphase examinations for both low- and high-contrast diagnostic tasks without requiring manufacturer-specific hardware or software.


Asunto(s)
Neoplasias Hepáticas , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
2.
Vascular ; 29(6): 927-937, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33459205

RESUMEN

OBJECTIVE: This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. METHODS: After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into "not opacified", "<50% stenosis", " 50 ̶70% stenosis", ">70% stenosis", and "occluded" for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. RESULTS: Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8-32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively (p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus (p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) (p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients (p = 0.319), respectively. CONCLUSION: Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste/administración & dosificación , Yohexol/administración & dosificación , Extremidad Inferior/irrigación sanguínea , Enfermedad Arterial Periférica/diagnóstico por imagen , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Índice de Severidad de la Enfermedad
3.
Abdom Radiol (NY) ; 45(1): 45-54, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31705250

RESUMEN

PURPOSE: Prior iterative reconstruction (PIR) spatially registers CT image data from multiple phases of enhancement to reduce image noise. We evaluated PIR in contrast-enhanced multiphase liver CT. METHODS: Patients with archived projection CT data with proven malignant or benign liver lesions, or without lesions, by reference criteria were included. Lower-dose PIR images were reconstructed using validated noise insertion from multiphase CT exams (50% dose in 2 phases, 25% dose in 1 phase). The phase of enhancement most relevant to the diagnostic task was selected for evaluation. Four radiologists reviewed routine-dose and lower-dose PIR images, circumscribing liver lesions and rating confidence for malignancy (0 to 100) and image quality. JAFROC Figures of Merit (FOM) were calculated. RESULTS: 31 patients had 60 liver lesions (28 primary hepatic malignancies, 6 hepatic metastases, 26 benign lesions). Pooled JAFROC FOM for malignancy for routine-dose CT was 0.615 (95% CI 0.464, 0.767) compared to 0.662 for PIR (95% CI 0.527, 0.797). The estimated FOM difference between the routine-dose and lower-dose PIR images was + 0.047 (95% CI - 0.023, + 0.116). Pooled sensitivity/specificity for routine-dose images was 70%/68% compared to 73%/66% for lower-dose PIR. Lower-dose PIR had lower diagnostic image quality (mean 3.8 vs. 4.2, p = 0.0009) and sharpness (mean 2.3 vs. 2.0, p = 0.0071). CONCLUSIONS: PIR is a promising method to reduce radiation dose for multiphase abdominal CT, preserving observer performance despite small reductions in image quality. Further work is warranted.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Neoplasias Hepáticas/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Proyectos Piloto , Intensificación de Imagen Radiográfica/métodos , Sensibilidad y Especificidad
4.
AJR Am J Roentgenol ; 208(3): 552-563, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28225687

RESUMEN

OBJECTIVE: The purpose of this study is to determine whether image quality was maintained when a weight-based protocol incorporating tube potential selection was used to select lower iodine contrast volumes for aortic CT angiography (CTA). MATERIALS AND METHODS: Patients with potentially decreased renal function underwent CTA performed with the iodinated contrast volume determined using a table incorporating different tube potentials and patient weights. The image quality of CTA examinations performed with a reduced iodine volume (hereafter known as "low-iodine CTA examinations"), internal control CTA examinations (i.e., prior examinations), and size-matched control CTA examinations was evaluated in separate reading sessions conducted by three vascular radiologists who were blinded as to the contrast volume and tube potential used. Side-by-side unblinded comparison of the examinations was also performed. Aortic attenuation and the contrast-to-noise ratio were measured. Comparisons were performed using the Wilcoxon signed rank test. RESULTS: Fifty low-iodine CTA examinations, 36 internal control CTA examinations, and 50 size-matched control CTA examinations were performed. Contrast volumes were 63% lower when the protocol based on tube potential and patient weight was used (mean contrast volume, 49 mL for low-iodine CTA vs 133 mL for internal control CTA and 138 mL for size-matched control CTA). The mean volume CT dose index was 15.1 mGy for low-iodine CTA versus 18.8 mGy for internal control CTA (p < 0.001), and 15.3 mGy for low-iodine CTA versus 17.1 mGy for size-matched control CTA (p = 0.11). Of the image quality and diagnostic confidence evaluations for low-iodine CTA examinations, over 97% had acceptable image quality and diagnostic confidence for blinded (50/50) and unblinded (35/36) comparisons. Aortic attenuation was similar between groups (p = 0.13-0.71). CONCLUSION: A weight-based protocol that incorporates tube potential selection allows the use of substantially lower volumes of iodinated contrast material in aortic CTA while maintaining acceptable image quality.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada/métodos , Yodo/administración & dosificación , Intensificación de Imagen Radiográfica/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Medios de Contraste/administración & dosificación , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Integración de Sistemas , Adulto Joven
5.
Abdom Radiol (NY) ; 42(2): 389-395, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28084545

RESUMEN

PURPOSE: The purpose of this study is to identify unique imaging findings of refractory celiac disease (RCD) including Type I RCD, Type II RCD versus healed celiac disease (CD). METHODS: A retrospective study of patients with known CD and refractory symptoms with cross-sectional imaging was performed. We included patients who underwent T cell receptor rearrangement or T-cell immunophenotyping studies on small bowel (SB) biopsies to classify patients into: healed CD, Type I RCD, or Type II RCD. GI radiologists performed a blinded review of the imaging studies. RESULTS: One-hundred eighteen patients (32 healed; 67 Type I RCD; 19 Type II RCD) were included (mean age 53 ± 6 years; 62% female). The presence of any fold pattern abnormality was more likely to be found in Type II and Type I RCD than healed CD (53% vs. 43% vs.16%; p = 0.009). Type II RCD patients were more likely than Type I RCD and healed CD to have imaging findings of ulcerative jejunitis (26% vs. 6% vs. 3%; p = 0.009), SB wall thickening (37% vs. 16% vs. 0%; p = 0.002) and SB dilation (26% vs. 7% vs. 6%; p = 0.04). Type II RCD demonstrated non-significant trends for decreased number of jejunal folds only, SB mass, mesenteric lymphadenopathy, localized peri-mural edema, and intramural duodenal edema. CONCLUSIONS: Fold pattern abnormalities, ulcerative jejunitis, SB wall thickening, and SB dilation are more likely to be identified in cross-sectional imaging of RCD than healed CD. SB dilatation and ulcerative jejunitis are more likely to be found in Type II than Type I RCD.


Asunto(s)
Enfermedad Celíaca/diagnóstico por imagen , Biopsia , Enfermedad Celíaca/patología , Femenino , Humanos , Inmunofenotipificación , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
6.
Abdom Radiol (NY) ; 42(5): 1365-1373, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28058449

RESUMEN

OBJECTIVE: Our purpose is to determine the impact of CT enterography on small bowel gastrointestinal stromal tumor (GIST) detection and biologic aggressiveness, and to identify any imaging findings that correlate with biologic aggressiveness. METHODS: Records of patients with histologically confirmed small bowel GISTs who underwent CT imaging were reviewed. Biologic aggressiveness was based on initial histologic grading (very low, low, intermediate, high grade; or malignant), with upgrade to malignant category if local or distant metastases developed during clinical follow-up. Imaging indications, findings, and type of CT exam were compared with the biologic aggressiveness. RESULTS: 111 small bowel GISTs were identified, with suspected small bowel bleeding being the most common indication (45/111; 40.5%). While the number of malignant GISTs diagnosed by CT remained relatively constant (2-3 per year), the number of non-malignant GISTs increased substantially (mean 1.5/year, 1998-2005; 8.4/year, 2006-2013). In patients with suspected small bowel bleeding, CT enterography identified 33 GISTs (7/33, 21% malignant) compared to 12 GISTs by abdominopelvic CT (6/12, 50% malignant; p < 0.03). Tumor size (p < 0.0001), internal necrosis (p = 0.005), internal air or enteric contrast (p ≤ 0.021), and ulceration (p ≤ 0.021) were significantly associated with high-grade and malignant tumors, and irregular or invasive tumor borders (p < 0.01) was associated with malignant tumors. CONCLUSION: The detection of small bowel GISTs can increase due to the use of CT enterography in patients with suspected small bowel bleeding. The large majority of small bowel GISTs detected by CT enterography are not malignant.


Asunto(s)
Tumores del Estroma Gastrointestinal/diagnóstico por imagen , Intestino Delgado , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Tumores del Estroma Gastrointestinal/patología , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Retrospectivos
7.
Rev Bras Ginecol Obstet ; 35(7): 331-5, 2013 Jul.
Artículo en Portugués | MEDLINE | ID: mdl-24080846

RESUMEN

The sclerosing stromal tumor of the ovary is an extremely rare benign tumor more common in young women and without specific symptoms in most cases. Less than 150 cases have been described, of which 8 were diagnosed during pregnancy. In this report, we describe the association between sclerosing stromal tumor of the ovary, Meigs' syndrome and elevated levels of CA-125 in term pregnancy.


Asunto(s)
Síndrome de Meigs/complicaciones , Síndrome de Meigs/diagnóstico , Neoplasias Ováricas/complicaciones , Neoplasias Ováricas/diagnóstico , Complicaciones del Embarazo/diagnóstico , Tumores de los Cordones Sexuales y Estroma de las Gónadas/complicaciones , Tumores de los Cordones Sexuales y Estroma de las Gónadas/diagnóstico , Adolescente , Antígeno Ca-125/sangre , Femenino , Humanos , Síndrome de Meigs/sangre , Neoplasias Ováricas/sangre , Embarazo , Complicaciones del Embarazo/sangre , Tumores de los Cordones Sexuales y Estroma de las Gónadas/sangre
8.
Rev. bras. ginecol. obstet ; 35(7): 331-335, July 2013. ilus
Artículo en Portugués | LILACS | ID: lil-687376

RESUMEN

O tumor estromal esclerosante de ovário é uma neoplasia benigna extremamente rara, mais frequente em mulheres jovens e sem sintomas específicos na maioria dos casos. Menos de 150 casos foram descritos, dos quais 8 diagnosticados durante a gestação. Neste relato, documentamos a associação entre tumor estromal esclerosante de ovário, síndrome de Meigs e elevação dos níveis de CA-125 em gravidez a termo.


The sclerosing stromal tumor of the ovary is an extremely rare benign tumor more common in young women and without specific symptoms in most cases. Less than 150 cases have been described, of which 8 were diagnosed during pregnancy. In this report, we describe the association between sclerosing stromal tumor of the ovary, Meigs' syndrome and elevated levels of CA-125 in term pregnancy.


Asunto(s)
Adolescente , Femenino , Humanos , Embarazo , Síndrome de Meigs/complicaciones , Síndrome de Meigs/diagnóstico , Neoplasias Ováricas/complicaciones , Neoplasias Ováricas/diagnóstico , Complicaciones del Embarazo/diagnóstico , Tumores de los Cordones Sexuales y Estroma de las Gónadas/complicaciones , Tumores de los Cordones Sexuales y Estroma de las Gónadas/diagnóstico , /sangre , Síndrome de Meigs/sangre , Neoplasias Ováricas/sangre , Complicaciones del Embarazo/sangre , Tumores de los Cordones Sexuales y Estroma de las Gónadas/sangre
9.
Comun. ciênc. saúde ; 22(sup. espc. 1): 129-140, 2011.
Artículo en Portugués | LILACS | ID: lil-619065

RESUMEN

A ultrassonografia mamária ganhou destaque na conduta dos mastologistasapós o desenvolvimento tecnológico dos aparelhos modernos. Seu uso é difundido principalmente na complementação de mamografias inconclusivas, em mulheres com mamas densas ou com fatores de risco importantes para câncer de mama, porém, não é indicada no uso do rastreamento de câncer de mama em mulheres assintomáticas. Outras indicações que se tornaram importantes são o monitoramento de procedimentos invasivos e a avaliação de nódulos mamários. A ecografia é um método aparelho e examinador dependente e depois da criaçãodo BI-RADS® ultrassonográfico diminuíram os índices de variabilidade entre observadores. Publicado em 2003 foi adaptado da classificação mamográfica mantendo as características semelhantes, contendouma nomenclatura padronizada, classificação de risco de malignidade eorientação da conduta a ser realizada. O léxico BI-RADS® é completoe bem aceito entre os examinadores, entretanto, pelo fato de conter algunspontos controversos é motivo de crítica de autores. Este artigo se propõe a colocar de maneira crítica a atual situação do uso da ecografia mamária na pratica clínica para os mastologistas e para os ecografistas, revisando também aspectos técnicos deste exame.


The breast ultrasound has gained prominence in the conduct of mastologists after the development of technological gadgets. Its use is particularly widespread in complementing inconclusive mammograms inwomen with dense breasts or with significant risk factors for breast cancer, however, is not indicated in the use for breast cancer screeningin asymptomatic women. Other important indications are the monitoringof invasive procedures and evaluation of invasive breast nodules. Ultrasound is a method examiner and device dependent, however, after the creation of sonographic BI-RADS® have decreased the levels of variability among observers. The sonographic BI-RADS® was published in 2003, adapted from the mammographic BI-RADS® itself, maintaining similar characteristics, with a standardized nomenclature and malignancy risk classification and guiding the conduct to be performed. The BI-RADS ® lexical is complete and well accepted amongthe examiners, however, because it contains some controversial points,it is a matter of critic of some authors. This article proposes to discusscritically the current situation of breast ultrasound use in the clinical practice of mastologists and radiologists, also reviewing the technical aspects of this examination.


Asunto(s)
Humanos , Femenino , Mama , Neoplasias de la Mama/prevención & control , Ultrasonografía , Ultrasonografía Mamaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA