RESUMEN
OBJECTIVE: To evaluate the effects of cigarette smoke inhalation on the immune-inflammatory profile of experimental apical periodontitis in rats. METHODOLOGY: In total, 32 male Wistar rats were divided into four groups (n = 8): AP-induced apical periodontitis; S-cigarette smoke inhalation; APS-induced AP and cigarette smoke inhalation; and C (control)-neither AP nor cigarette smoke inhalation. To induce cigarette smoke inhalation, the animals were kept in a chamber filled with tobacco smoke for 8 min thrice a day for 50 days. AP was induced 20 days after inhalation initiation by exposing their coronary pulp to their oral environment for 30 days. After animals were euthanized, their right hemimaxillae were removed for histopathological, semi-quantitative and immunohistochemical (F4/80, CD206 and iNOS) analyses. RESULTS: Quantitative data showed a moderate number of inflammatory infiltrates in AP and an intense number in APS (p < .05). Comparing F4/80+ cells showed no statistically significant differences among groups, but we found more CD206+ cells in AP than in C and S (p > .05). INOS+ immunostaining showed a significant increase in AP and APS, when compared with C and S (p < .05). APS had more iNOS+ cells than AP (p < .05). CONCLUSION: Cigarette smoke inhalation worsened AP, leading to a predominantly pro- inflammatory profile in our experimental model.
Asunto(s)
Fumar Cigarrillos , Periodontitis Periapical , Ratas , Masculino , Animales , Ratas Wistar , Periodontitis Periapical/patologíaRESUMEN
Biocompatibility and biomineralization of root canal dressings are important requirements for periapical healing. This study evaluated the inflammatory response, biomineralization and tissue repair by collagen fiber maturation in the subcutaneous tissue of rats. Eighteen Wistar rats (n = 6) received subcutaneous implants: calcium hydroxide + propylene glycol [CH+P], calcium hydroxide + propylene glycol + iodoform [CH+P+I], iodoform + carbowax [I+Cwax] and carbowax [Cwax]. Extra empty tubes were used as a control [C]. After 7, 15 and 30 days, the implants were removed with surrounding tissue for staining of hematoxylin-eosin, Von Kossa, picrosirius red and without staining for analysis under polarized light. Results were analyzed via Kruskal-Wallis followed by Dunn testing for nonparametric data and ANOVA followed by a Tukey post hoc test for parametric data (p < 5%). At 7 days, all groups showed a moderate inflammatory reaction and thick fibrous capsule, except the [Cwax] group, with a severe inflammatory infiltrate (p < 0.05). After 15 days, all groups but control had a decrease in inflammatory response. At 30 days, all groups presented a mild reaction and thin fibrous capsule (p > 0.05). Only groups containing calcium hydroxide were found to be positive using Von Kossa staining and polarized light in all periods. At 7 days, all groups showed a higher proportion of immature fibers. At 15 days, the [CH+P] and [Cwax] groups increased their proportion of mature/immature fibers. At 30 days, only the [CH+P] group presented a significant prevalence of mature collagen fibers (p < 0.05). All groups showed biocompatibility, but only groups containing calcium hydroxide induced biomineralization. The addition of iodoform delayed tissue healing.
RESUMEN
The purpose of this study was to evaluate, in vivo, the biocompatibility, biomineralization, collagen maturation and the in vitro antibacterial and cytotoxicity of resinous endodontic sealers containing calcium hydroxide. Forty rats were implanted with polyethylene tubes containing Sealer 26, Sealer Plus, Dia-ProSeal and an empty tube, examined after 7, 15, 30 and 60 days. Antimicrobial activity was evaluated against Enterococcus faecalis by Agar Diffusion Test (ADT) through inhibition zones. For cytotoxicity, undifferentiated pulp cells (OD-21) were cultured and assessed using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, exposed to dilution of serial extracts at 6, 24, 48h. Cytotoxicity was analyzed by two-way ANOVA and Bonferroni correction. Kruskal-Wallis test followed by Dunn test was performed for nonparametric data (p<0.05). MTT assay revealed cell proliferation affected by sealers extract in all periods (p<0.0001), except for Dia-Proseal and Sealer Plus â dilution. Subcutaneous analysis showed at day 7th moderate inflammatory infiltration. After 30 days, Sealer 26 still showed moderate inflammatory infiltrate compared to mild inflammation from control and Dia-ProSeal (p = 0.006). At day 60th, all groups showed similar mild inflammatory infiltrate (p>0.05). Sealer 26 induced more biomineralization than other sealers in all periods. At 7 and 15 days, all sealers had significant percentage of immature collagen fibers. After 60 days Sealer 26 showed more mature fibers compared to other sealers (p<0.001). All sealers had a smaller zone of inhibition than chlorhexidine, but with no significant difference among any group (p>0.05). All sealers showed satisfactory biological responses with in vitro/in vivo biocompatibility and antimicrobial activity against planktonic bacteria. Sealer 26 induced more biomineralization than Sealer Plus and Dia-ProSeal.
Asunto(s)
Hidróxido de Calcio , Materiales de Obturación del Conducto Radicular , Ratas , Animales , Hidróxido de Calcio/farmacología , Materiales de Obturación del Conducto Radicular/farmacología , Resinas Epoxi , Ensayo de Materiales , Resinas de Plantas , Antibacterianos/farmacologíaRESUMEN
AIM: The aim of this study was to evaluate the effects of cigarette smoke inhalation (CSI) on inflammation, pro-inflammatory mediators and haematological parameters in rats with induced apical periodontitis (AP). METHODOLOGY: Thirty-two 3-month-old male Wistar rats were divided into four experimental groups (n = 8): C-Control; S-rats with CSI; AP-rats with AP; and SAP-rats with CSI + AP. Animals in groups S and SAP inhaled cigarette smoke by remaining inside a smoking chamber for 8 min, three times daily, for 50 days. After 20 days of smoke inhalation, animals in AP and SAP groups had the pulps of the lower right first molar exposed to oral environment for 30 days to induce AP. In these subsequent 30 days, animals in group S and SAP continued with CSI. On Day 50, animals were euthanized and mandibles were histologically processed to assess inflammatory infiltrate, immunohistochemical interleukins (IL-1ß, IL-6 and TNF-α), and blood samples collected for laboratory analysis. The Mann-Whitney test was performed for non-parametric data and the pairwise analyses of Student's t-test for parametric data, with a significance level of p < .050. RESULTS: Inflammatory infiltrate was moderate in AP group and more severe in the SAP (p = .010). The interleukins IL-6, IL-1ß and TNF-α were higher in SAP group (p < .001) when compared to the AP group. A greater number of red blood cells (p = .010), haemoglobin (p = .007) and neutrophils (p = .014) were observed in the SAP group in comparison with the AP group. CONCLUSION: Cigarette smoke inhalation induced a more severe inflammatory infiltrate, with increased levels of pro-inflammatory cytokines and changes in haematological parameters in rats with induced AP. Thus, CSI aggravated AP, exacerbating the inflammatory response.
Asunto(s)
Fumar Cigarrillos , Periodontitis Periapical , Ratas , Masculino , Animales , Ratas Wistar , Interleucina-6 , Factor de Necrosis Tumoral alfa , Periodontitis Periapical/patologíaRESUMEN
A infecção endodôntica ocorre a após contaminação do tecido pulpar levando à uma colonização bacteriana dos canais radiculares resultando em uma resposta inflamatória dos tecidos periapicais e formação de uma lesão periapical, a periodontite apical (PA). O tabagismo, por sua vez, tem impactos prejudiciais à saúde oral e sistêmica sendo considerado um importante fator de risco para as doenças periodontais. Este trabalho tem por finalidade investigar a influência do tabagismo no desenvolvimento da periodontite apical em ratos. Trinta e dois ratos machos Wistar foram divididos em 4 grupos experimentais (n=8): Controle (sem periodontite apical induzida e sem inalação da fumaça do cigarro); FU (com inalação a fumaça do cigarro); PA (com periodontite apical induzida); FU+PA (com inalação a fumaça do cigarro e periodontite apical induzida). Para a inalar a fumaça do cigarro, grupo de cinco animais permaneceram em uma câmara de tabagismo inalando a fumaça de 10 cigarros por 8 minutos, três vezes ao dia, durante 50 dias. Decorridos 20 dias de inalação de fumaça do cigarro, foi realizada a cirurgia para indução da periodontite apical nos animais do grupo PA e FU+PA, no primeiro molar inferior direto, o qual permaneceu aberto na cavidade bucal por 30 dias. Nesses 30 dias subsequentes da indução da PA, os animais do grupo FU+PA e FU continuaram com a inalação a fumaça do cigarro. No 50º dia, os animais foram eutanasiados e coletados amostras de tecido hematológico para avalição dos níveis séricos de nicotina, cotinina, fosfatase alcalina, cálcio, fósforo, série vermelha e série branca. As hemimandibula removidas foram escaneadas em microtomógrafo para avaliar o volume da destruição óssea e processadas histologicamente para avaliação do perfil inflamatório e expressão das citocinas IL-6, IL-1ß, TNF-α e dos marcadores do metabolismo ósseo RANKL e OPG. Os dados foram tabulados e aplicados os testes estatísticos de Mann-Whitney para os dados não paramétricos e teste t para os dados paramétricos, a um nível de significância de P< 0.05. Com relação a análise histológica o grupo FU+PA apresentou infiltrado inflamatório mais intenso em relação aos demais grupos (P< 0,05). As citocinas pró-inflamatórias IL-6, IL-1ß, TNF-α apresentaram alto padrão de imunomarcação para o grupo FU+PA (P< 0,05). A análise histométrica mostrou maior área de reabsorção óssea no grupo FU+PA, assim como na análise microtomográfica (P< 0,05). As citocinas RANKL esteve mais expressa no grupo FU+PA (P< 0,05) e OPG teve maior expressão no grupo PA (P< 0,05). Na análise hematológica houve um aumento na concentração de hemácias, hemoglobina e leucócitos para o FU+PA (P< 0,05). Os níveis séricos de cálcio foram menores no FU+PA (P> 0,05), a fosfatase alcalina e o cálcio se manteve constante em todos os grupos experimentais (P> 0,05). A concentração sérica de nicotina e cotinina no grupo FU e FU+PA foram compatíveis com fumante humano(AU)
Endodontic infection occurs mainly after pulp tissue contamination by a carious process, leading to bacterial colonization of root canal system and inflammatory response of periapical tissues, followed by formation of apical periodontitis (AP). It is widely known that smoking has harmful impacts on oral and systemic health and is considered a risk factor for periodontal diseases. The objective of this research was to investigate the influence of smoking on the development of AP in rats. Thirty-two male Wistar rats were divided into 4 experimental groups (n = 8): C - Control (no induced AP and no cigarette smoke inhalation); CSI (cigarette smoke inhalation); AP (induced apical periodontitis); CSI + AP (cigarette smoke inhalation and induced apical periodontitis). To inhale cigarette smoke, group with five animals remained in a smoking chamber inhaling smoke from 10 cigarettes for 8 minutes, three times daily, for 50 days. After 20 days of cigarette smoke inhalation, pulp chamber access was performed to induce apical periodontitis in the first mandibular right molar, which remained with pulp chamber exposed to oral cavity for 30 days in animals in the AP and CSI + AP group. During these 30 days after the AP induction, animals in the CSI + AP and CSI group continued to inhale cigarette smoke. On the 50th day, animals were euthanized and blood sample collected to assess serum levels of nicotine, cotinine, alkaline phosphatase, calcium, phosphorus, red series and white series. The hemimandibles were removed and scanned in microtomograph to assess bone volume and histologically processed to assess inflammatory profile and expression of cytokines IL-6, IL-1ß, TNF-α and bone metabolism markers RANKL and OPG. Data were tabulated and statistically analyzed using Mann-Whitney tests for nonparametric data and analysis of variation test for parametric data, with a significance level of P< 0.05. Regarding histological analysis, CSI+AP group showed more intense inflammatory infiltrate compared to other groups (P < 0.05). Histometric analysis showed a larger area of bone resorption in the CSI + AP group, also observed in the microtomographic analysis (P< 0.05). Group CSI+AP had elevated pro-inflammatory cytokines IL-6, IL-1ß, TNF-α expression (P< 0.05). The RANKL cytokines were also more expressed in the CSI+AP group (P< 0.05), while OPG was more expressed in the AP group (P< 0.05). The hematological analysis revealed an increase in the concentration of red blood cells, hemoglobin, and leukocytes for CSI+AP (P< 0.05). Serum calcium levels were lower in CSI+AP (P> 0.05), and alkaline phosphatase and calcium remained constant in all experimental groups (P> 0.05). The serum concentrations of nicotine and cotinine in the CSI and CSI+AP group were compatible with human smokers(AU)
Asunto(s)
Animales , Ratas , Fósforo , Calcio , Salud Bucal , Interleucina-6 , Factor de Necrosis Tumoral alfa , Cotinina , Fosfatasa Alcalina , Interleucina-1beta , NicotinaRESUMEN
BACKGROUND: This study aimed to track the toxic ions released by MTA Fillapex, BioRoot RCS, and an experimental tricalcium silicate-based sealer (CEO) into local and distant tissues as well as to investigate their potential adverse effects. In addition, the chemical constituents of the sealers were also evaluated. The main components of the dry powders, pastes, and mixed sealers were characterized. MATERIAL AND METHODS: Dry powder and sealer discs were each set for 72 h and their main components were characterized by energy dispersive X-ray spectroscopy. Polyethylene tubes filled with sealers were used to measure silicon and calcium ions. Polyethylene tubes filled with sealers or empty tubes were implanted into the dorsal connective tissue of Wistar rats. On days 7, 15, 30, and 45, the animals were euthanized and their brains, livers, kidneys, and subcutaneous tissues were removed and processed to determine the concentrations of chromium, cobalt, copper, lead, iron, magnesium and nickel using an inductively coupled plasma optical emission spectrometer. RESULTS: The main compounds in all sealers were carbon, oxygen, silicon, and calcium. MTA Fillapex release more Si while highest levels of Si were found in presence of BioRoot. The release of Si and Ca ions promoted by MTA Fillapex raise by time. No traces of cobalt, chromium, or magnesium were detected in any tissue. Irrespective of the sealer, no traces of copper and lead were found in the subcutaneous tissue; however, they were observed in the organs. The highest concentration of iron was identified in the liver. All sealers exhibited similar nickel traces in the brain, kidney, and liver except for MTA Fillapex, which demonstrated levels higher than CEO in the subcutaneous tissue on day 7. Tracing nickel ions over time revealed that lowest concentrations were found in subcutaneous tissue. CONCLUSION: Taken together, our data demonstrate that CEOs have chemical compositions similar to those of other commercial sealers. Furthermore, none of them exhibited a threat to systemic health. Moreover, the minimal amounts of iron and nickel detected were not related to the sealers.
Asunto(s)
Materiales de Obturación del Conducto Radicular , Animales , Ratas , Calcio , Compuestos de Calcio , Cromo , Cobalto , Cobre , Resinas Epoxi , Hierro , Magnesio , Ensayo de Materiales , Níquel , Óxidos/toxicidad , Polietilenos , Ratas Wistar , Materiales de Obturación del Conducto Radicular/toxicidad , Silicatos , SilicioRESUMEN
This research evaluated, in vivo, the accuracy of three electronic apex locators - EALs (Root ZXII, E-PEX and FIND) in teeth with vital pulp submitted to biopulpectomy, preserving the periodontal stump. For this study, 90 single-rooted teeth with extraction indication were selected. After positive pulpal cold sensitivity test, pulp chamber access was performed. The cervical and middle thirds of root canals were instrumented with Reciproc R25, and the K#15 file was used as a standard instrument to determine working length, forming 2 groups: Constriction (insertion of the instrument until the apical constriction limit) and Foramen (insertion of the instrument until the foramen and then repositioning at constriction, without removing the file from the canal). The hand file was stabilized with a light-cured flow resin. After extraction, the samples were analyzed through microCT SkyScan 1272, with CTAN software, which evaluated the proximity between the tip of the file to the apical constriction, providing data for comparative analysis using Kruskal-Wallis and Dunn tests (p<0.05). There was a statistically significant difference in the abilities of the EALs to detect the apical constriction after reaching the foramen with Root ZX II showing higher accuracy (89%). However, there was no difference in the accuracy of the three EALs in detecting the apical constriction without reaching the foramen. Based on the present results, we conclude that EALs may show accurate measures in detecting apical constriction and foramen, even without damaging the periodontal stump in biopulpectomy.
Asunto(s)
Cavidad Pulpar , Ápice del Diente , Odontometría , Preparación del Conducto Radicular , Ápice del Diente/diagnóstico por imagen , Raíz del Diente , Microtomografía por Rayos XRESUMEN
Abstract: This research evaluated, in vivo, the accuracy of three electronic apex locators - EALs (Root ZXII, E-PEX and FIND) in teeth with vital pulp submitted to biopulpectomy, preserving the periodontal stump. For this study, 90 single-rooted teeth with extraction indication were selected. After positive pulpal cold sensitivity test, pulp chamber access was performed. The cervical and middle thirds of root canals were instrumented with Reciproc R25, and the K#15 file was used as a standard instrument to determine working length, forming 2 groups: Constriction (insertion of the instrument until the apical constriction limit) and Foramen (insertion of the instrument until the foramen and then repositioning at constriction, without removing the file from the canal). The hand file was stabilized with a light-cured flow resin. After extraction, the samples were analyzed through microCT SkyScan 1272, with CTAN software, which evaluated the proximity between the tip of the file to the apical constriction, providing data for comparative analysis using Kruskal-Wallis and Dunn tests (p<0.05). There was a statistically significant difference in the abilities of the EALs to detect the apical constriction after reaching the foramen with Root ZX II showing higher accuracy (89%). However, there was no difference in the accuracy of the three EALs in detecting the apical constriction without reaching the foramen. Based on the present results, we conclude that EALs may show accurate measures in detecting apical constriction and foramen, even without damaging the periodontal stump in biopulpectomy.
Asunto(s)
Ápice del Diente/diagnóstico por imagen , Cavidad Pulpar , Raíz del Diente , Preparación del Conducto Radicular , Microtomografía por Rayos X , OdontometríaRESUMEN
This study aimed to assess the cyclic fatigue resistance of Genius and EdgeFile X1 reciprocating instruments compared with WaveOne Gold Primary. Twenty Genius (Ultradent) 25.04, 20 Genius 30.04, 20 EdgeFile X1 (EdgeEndo) and 20 WaveOne Gold Primary (Dentsply Maillefer) instruments were included in this study and tested in a static cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated in reciprocation mode until fracture occurred. The number of cycles to failure (NCF) was calculated and time to fracture (TF) was recorded in seconds using a digital chronometer. The mean and standard deviations of NCF and TF were calculated for each reciprocating system and the data were subjected to Kruskal-Wallis one-way analysis of variance and to Dunn's test (p < .05) using SigmaPlot software (Systat software, CA, USA). The fractured surfaces of five instruments from each brand were randomly examined and microphotographed by a low-vacuum environmental scanning electron microscopy - SEM (Tabletop Microscope TM3030, Hitachi, Japan) to confirm the cyclic fatigue fracture. EdgeFile exhibited the highest cyclic fatigue resistance, followed by both Genius files (p < .05). Within the limitations of this in vitro study, EdgeFile X1 instruments had significantly higher cyclic fatigue resistance than did Genius and WaveOne Gold Primary instruments. The cyclic fatigue resistance of both Genius files was higher than that of WaveOne Gold Primary.
Asunto(s)
Instrumentos Dentales/normas , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Diseño de Equipo , Análisis de Falla de Equipo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Valores de Referencia , Estadísticas no Paramétricas , Estrés Mecánico , Propiedades de Superficie , Factores de TiempoRESUMEN
In endodontic treatment, regardless of the instrumentation technique, the presence of a smear layer covering contaminated dentin walls is always a concern. Thus, irrigation plays an essential role in reducing bacterial load. To enhance irrigation effectiveness, different ultrasonic activation methods and the use of different tips have been studied. This study assessed the cleaning capacity of the novel NiTi ultrasonic tip for smear layer removal using ultrasonically activated irrigation (UAI) with passive or continuous ultrasonic irrigation (PUI or CUI, respectively), compared with conventional irrigation. Forty-five single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Instrumentation was performed using the Genius system up to size 50.04 and irrigated with 3% NaOCl. The specimens were divided into three groups (n = 15) according to the final irrigation activation technique: conventional irrigation (CI), as control group; PUI; and CUI, following the manufacturer's protocol. The samples were longitudinally cleaved and analyzed under a scanning electron microscope for smear layer removal according to a cleanliness score for the cervical, middle, and apical thirds. Data were evaluated by means of the Kruskal-Wallis and Tukey's tests, with a 5% level of significance. UAI enhanced cleaning compared to conventional irrigation, mainly at the apical third. CUI showed the best results, with statistically significant lower scores than PUI and CI (p < 0.05). Final irrigant activation with the NiTi tip showed better cleaning capacity than conventional irrigation. In addition, CUI resulted in better smear layer removal than PUI.
Asunto(s)
Profilaxis Dental/métodos , Cavidad Pulpar , Níquel , Irrigantes del Conducto Radicular/uso terapéutico , Titanio , Terapia por Ultrasonido/métodos , Humanos , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodosRESUMEN
OBJECTIVE: Evaluate, in vivo, the biocompatibility via subcutaneous inflammatory tissue response and mineralization ability of the new MTA Flow compared to MTA Angelus and ProRoot MTA. MATERIALS AND METHODS: Forty male Wistar rats were assigned and received subcutaneous polyethylene tube implants containing the test materials and a control group with empty tube (n = 10 animals/group). After days 7, 15, 30, and 60, the animals were euthanized and the polyethylene tubes were removed with the surrounding tissues. Inflammatory infiltrate and thickness of the fibrous capsule were histologically evaluated. Mineralization was analyzed by Von Kossa staining and under polarized light. Data were analyzed via Kruskal-Wallis and Dunn's test with a significance level of 5%. RESULTS: MTA Angelus induced the mildest reaction after 7 (P > .05) and 15 days (P < .05) followed by MTA Flow, both cements achieving mild inflammatory reaction after 15 days. ProRoot MTA induced a severe inflammation on day 7 and was reducing after day 15 (P > .05). No difference was observed after days 30 or 60 (P > .05). Von Kossa staining and birefringent structures were positive to all materials. CONCLUSIONS: At the end of the experiment, the novel MTA Flow showed biocompatibility and induced biomineralization in all time periods. CLINICAL RELEVANCE: The final consistence obtained in MTA Flow may facilitate several procedures, indicating that the MTA Flow has a promising application in endodontics.
Asunto(s)
Compuestos de Aluminio/farmacología , Materiales Biocompatibles/farmacología , Biomineralización , Compuestos de Calcio/farmacología , Óxidos/farmacología , Silicatos/farmacología , Tejido Subcutáneo/efectos de los fármacos , Animales , Bismuto , Combinación de Medicamentos , Implantes de Medicamentos , Masculino , Ratas , Ratas Wistar , Materiales de Obturación del Conducto RadicularRESUMEN
Abstract In endodontic treatment, regardless of the instrumentation technique, the presence of a smear layer covering contaminated dentin walls is always a concern. Thus, irrigation plays an essential role in reducing bacterial load. To enhance irrigation effectiveness, different ultrasonic activation methods and the use of different tips have been studied. This study assessed the cleaning capacity of the novel NiTi ultrasonic tip for smear layer removal using ultrasonically activated irrigation (UAI) with passive or continuous ultrasonic irrigation (PUI or CUI, respectively), compared with conventional irrigation. Forty-five single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Instrumentation was performed using the Genius system up to size 50.04 and irrigated with 3% NaOCl. The specimens were divided into three groups (n = 15) according to the final irrigation activation technique: conventional irrigation (CI), as control group; PUI; and CUI, following the manufacturer's protocol. The samples were longitudinally cleaved and analyzed under a scanning electron microscope for smear layer removal according to a cleanliness score for the cervical, middle, and apical thirds. Data were evaluated by means of the Kruskal-Wallis and Tukey's tests, with a 5% level of significance. UAI enhanced cleaning compared to conventional irrigation, mainly at the apical third. CUI showed the best results, with statistically significant lower scores than PUI and CI (p < 0.05). Final irrigant activation with the NiTi tip showed better cleaning capacity than conventional irrigation. In addition, CUI resulted in better smear layer removal than PUI.
Asunto(s)
Humanos , Irrigantes del Conducto Radicular/uso terapéutico , Terapéutica/métodos , Titanio , Profilaxis Dental/métodos , Cavidad Pulpar , Níquel , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodosRESUMEN
The aim of this study was to evaluate edemogenic activity and subcutaneous inflammatory reaction induced by Psidium cattleianum leaf extracts associated with Ca(OH)2. Thirty male Wistar rats, split equally into three groups [aqueous extract + Ca(OH)2; ethanolic extract + Ca(OH)2; and propylene glycol + Ca(OH)2], were assessed every 3 h or 6 h (five animals in each period). Under general anesthesia, 0.2 mL of 1% Evans blue per 100 g of body weight was injected into the penile vein and each combination to be evaluated was subcutaneously injected into the dorsal region 30 min thereafter. Edemogenic activity was analyzed by spectrophotometry (λ=630 nm). For inflammatory reaction analysis, 50 rats received four polyethylene tubes (three experimental groups) and an empty tube (control group). The assessments were made at 7, 15, 30, 60, and 90 days, followed by hematoxylin-eosin staining and by the assignment of scores for evaluation of tissue response intensity. Ethanolic extract + Ca(OH)2 yielded the largest edemogenic activity at 3 h. Intergroup differences at 6 h were not significant. The histological analysis showed progressive repair over time (p<0.05) and aqueous and ethanolic extracts produced similar responses to those of the control and Ca(OH)2 + propylene glycol groups. Psidium cattleianum leaf extracts used as Ca(OH)2 vehicles evoked similar tissue response when compared to Ca(OH)2 associated with propylene glycol.
Asunto(s)
Hidróxido de Calcio/farmacología , Extractos Vegetales/farmacología , Psidium/química , Tejido Subcutáneo/efectos de los fármacos , Animales , Antiinfecciosos/farmacología , Portadores de Fármacos , Evaluación Preclínica de Medicamentos , Etanol/farmacología , Inflamación/tratamiento farmacológico , Inflamación/patología , Masculino , Ensayo de Materiales , Vehículos Farmacéuticos/química , Vehículos Farmacéuticos/farmacología , Hojas de la Planta/química , Propilenglicol/farmacología , Ratas Wistar , Reproducibilidad de los Resultados , Tejido Subcutáneo/patología , Factores de Tiempo , Agua/químicaRESUMEN
Objectives: Evaluate, in vivo, the influence of mixing failures on endodontic sealers. Material and Methods: To alveolus analysis, 80 rats were divided into Sealapex® and AH Plus® groups. Within each group, the sealer was subjected to either partial (incomplete homogenization simulating handling failures) or total mixing (complete homogenization) over two periods of 7 and 30 days (n = 20). The maxillary incisor was extracted and a polyethylene tube containing the sealer was inserted. To quantify edema, 40 male rats were divided into four groups (n = 10). The animals received 2% Evans Blue intravenously, and either AH Plus® or Sealapex® was injected subcutaneously. The rats were euthanized after 3 or 6 hours and analyzed in a spectrophotometer (630 Æm). To analyze the subcutaneous tissue, 20 rats received polyethylene tube implants with the sealers in the dorsal area (n=10), then euthanized after either 7 or 30 days, and inflammation was evaluated according to an inflammatory cells score. Results: In the alveolar 7-day group, control group presented an inflammation score 1, while all other groups presented a score 2, except AH plus® total mix group (3). After 30 days, all groups presented a score 1. The edemogenic test showed less edema in Sealapex® groups (p < 0.5). In subcutaneous 7-day period, all groups presented score 2. In 30 days, all groups revealed score 1, except AH Plus® partial mix group (2). Conclusion: Regarding mixing of the sealers, there were no significant differences among the groups (AU)
Objetivo: Avaliar, in vivo, a influência das falhas de espatulação de cimentos endodônticos. Material e Métodos: Para análise alveolar, 80 ratos foram divididos nos grupos Sealapex® e AH Plus®. Em cada grupo, o cimento foi espatulado de forma parcial (homogeneização incompleta, simulando falhas) ou total (homogeneização completa) em dois períodos de 7 e 30 dias (n=20). O incisivo superior foi extraído e um tubo de polietileno contendo o cimento foi inserido. Para quantificar edema, 40 ratos foram divididos em quatro grupos (n = 10). Os animais receberam Azul de Evans 2% intravenoso, e AH Plus® ou Sealapex® injetados no tecido subcutâneo. Após 3 ou 6 horas foram eutanasiados e analisados em espectrofotômetro (630 Æm). Para analisar a resposta subcutânea, 20 ratos receberam implantes de tubo de polietileno com os cimentos na região dorsal (n = 10), eutanasiados após 7 ou 30 dias, e a inflamação foi avaliada de acordo com um escore de células inflamatórias. Resultados: Na análise alveolar em 7 dias, o grupo controle apresentou escore 1 de inflamação, enquanto que todos os outros grupos apresentaram 2, com exceção do AH plus® espatulação total (3). Após 30 dias, todos os grupos apresentaram escore 1. O teste edemogênico mostrou menor edema nos grupos Sealapex® (p < 0,5). No período subcutâneo de 7 dias, todos os grupos apresentaram escore 2. Em 30 dias, todos os grupos revelaram escore 1, exceto AH Plus® espatulação parcial (2). Conclusão: Não houve diferença estatística significante entre os cimentos quanto à espatulação. (AU)
Asunto(s)
Animales , Ratas , Cementos Dentales/farmacología , Ensayo de Materiales/métodos , Obturadores Palatinos , Fracaso de la Restauración Dental , InflamaciónRESUMEN
Abstract The aim of this study was to evaluate edemogenic activity and subcutaneous inflammatory reaction induced by Psidium cattleianum leaf extracts associated with Ca(OH)2. Thirty male Wistar rats, split equally into three groups [aqueous extract + Ca(OH)2; ethanolic extract + Ca(OH)2; and propylene glycol + Ca(OH)2], were assessed every 3 h or 6 h (five animals in each period). Under general anesthesia, 0.2 mL of 1% Evans blue per 100 g of body weight was injected into the penile vein and each combination to be evaluated was subcutaneously injected into the dorsal region 30 min thereafter. Edemogenic activity was analyzed by spectrophotometry (λ=630 nm). For inflammatory reaction analysis, 50 rats received four polyethylene tubes (three experimental groups) and an empty tube (control group). The assessments were made at 7, 15, 30, 60, and 90 days, followed by hematoxylin-eosin staining and by the assignment of scores for evaluation of tissue response intensity. Ethanolic extract + Ca(OH)2 yielded the largest edemogenic activity at 3 h. Intergroup differences at 6 h were not significant. The histological analysis showed progressive repair over time (p<0.05) and aqueous and ethanolic extracts produced similar responses to those of the control and Ca(OH)2 + propylene glycol groups. Psidium cattleianum leaf extracts used as Ca(OH)2 vehicles evoked similar tissue response when compared to Ca(OH)2 associated with propylene glycol.