Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39243831

RESUMEN

Drug-coated balloons have emerged as a promising therapeutic option in the treatment of cardiovascular disease. This review article provides an overview of the concept of drug-coated balloons and their clinical applications in both de novo and treated coronary artery disease. A summary of key clinical trials and registry studies evaluating drug-coated balloons is presented for reference. Overall, this article aims to provide clinicians and researchers with a comprehensive understanding of the current state of drug-coated balloon technology and its implications in clinical practice.

2.
Eur Heart J Open ; 4(5): oeae061, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39219854

RESUMEN

Aims: Stroke is the most debilitating outcome of atrial fibrillation (AF). The use of implantable loop recorders increases the detection of AF episodes among patients with embolic stroke of undetermined source. The significance of device-detected AF, or subclinical AF, is unknown. This study aimed to compare the incidence of AF detected by implantable loop recorder in patients with and without embolic stroke of undetermined source. Methods and results: We retrospectively studied all patients without known AF who were referred to our institution for implantable loop recorder implantation following embolic stroke of undetermined source, syncope, or palpitations from March 2009 to November 2019. The primary endpoint was any detection of AF or atrial flutter by implantable loop recorder. Seven hundred and fifty patients were included and followed up for a mean duration of 731 days (SD 443). An implantable loop recorder was implanted following embolic stroke of undetermined source in 323 and for assessment of syncope, palpitations, or another reason in 427 patients. The incidence of AF was significantly (P < 0.001) higher among patients with embolic stroke of undetermined source compared with the non-embolic stroke of undetermined source group; 48.6% vs. 13.8% (for any duration of AF) and 32.2% vs. 12.4% (for AF lasting ≥30 s) both P < 0.001. Kaplan-Meier analysis showed significantly higher incidence of AF for incremental durations of AF up to >5.5 h, but not >24 h. This was driven by longest AF durations of <6 min and between 5.5 h and 24 h, suggesting a bimodal distribution. In a multivariable Cox regression analysis, embolic stroke of undetermined source independently conferred an almost 5-fold increase in the hazard for any duration of AF. Conclusion: The incidence of AF is significantly higher amongst embolic stroke of undetermined source vs. non-embolic stroke of undetermined source patients monitored constantly by an implantable loop recorder. A high number of embolic stroke of undetermined source survivors have short-duration AF episodes. Further work is needed to determine the optimal treatment strategy of these AF episodes in embolic stroke of undetermined source.

3.
Open Heart ; 11(2)2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160086

RESUMEN

BACKGROUND: Aortic conduit and reservoir functions can be directly measured by four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR). METHODS: Twenty healthy controls (10 young and 10 age-gender-matched old controls) and 20 patients with heart failure with preserved ejection fraction (HFpEF) were recruited. All had 4D flow CMR. Flow was quantified at the ascending and descending aorta levels. In addition, at the ascending aorta level, we quantified systolic flow displacement (FDs) and systolic flow reversal ratio (sFRR). The aortic conduit function was defined as the relative drop in systolic flow from the ascending to the descending aorta (∆Fs). Aortic reservoir function was defined as descending aortic diastolic stroke volume (DAo SVd). RESULTS: Both ∆Fs (R=0.51, p=0.001) and DAo SVd (R=-0.68, p=0.001) were significantly associated with ageing. Native T1 (R=0.51, p=0.001) and extracellular volume (R=0.51, p=0.001) showed maximum association with ∆Fs. ∆Fs significantly increased in HFpEF versus age-gender-matched controls (41±8% vs 52±12%, p=0.02). In multiple regression, only ∆Fs and DAo SVd were independent predictors of the estimated glomerular filtration rate (model R=0.77, p=0.0001). FDs was significantly associated with ∆Fs (R=0.4, p=0.01) and DAo SVd (R=-0.48, p=0.002), whereas sFRR was mainly associated with DAo SVd (R=-0.46, p=0.003). CONCLUSION: Both aortic conduit and reservoir function decline with age and this decline in aortic function is also independently associated with renal functional decline. Ascending aortic turbulent flow signatures are associated with loss of aortic conduit and reservoir functions. Finally, in HFpEF, aortic conduit and reservoir function demonstrate progressive decline. TRIALS REGISTRATION NUMBER: NCT05114785.


Asunto(s)
Relevancia Clínica , Insuficiencia Cardíaca , Volumen Sistólico , Función Ventricular Izquierda , Femenino , Humanos , Masculino , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología
4.
J Clin Med ; 13(15)2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39124787

RESUMEN

Background/Objectives: The need to determine the safest duration of dual antiplatelet therapy duration after elective angioplasty to reduce bleeding events without an adverse effect on major adverse cardiovascular events (MACE) remains a challenge. Methods: In this investigator-initiated, single-centre cohort study, we identified all patients who underwent PCI for de novo coronary disease for stable angina between January 2015 and November 2019. We compared 1-month and 12-month durations of dual antiplatelet therapy (DAPT) to determine if there was any difference in the primary outcome of major bleeding. The secondary outcome was a patient-oriented composite endpoint of all-cause mortality; any myocardial infarction, stroke, or revascularisation; and the individual components of this composite endpoint. Data were analysed using Cox regression models and cumulative hazard plots. Results: A total of 1025 patients were analysed, of which 340 received 1 month of DAPT and 685 received 12 months of DAPT. There was no difference in major bleeding between the two groups (2.6% vs. 2.5% respectively). On univariable cox regression analysis, no characteristics were predictors of major bleeding. A proportion of 99.7% of patients in the 1-month DAPT arm were treated with a DCB strategy, whilst 93% in the 12-month DAPT group were treated with a DES. There was no difference between the two groups with regards to the composite patient-oriented MACE (11% vs. 12%, respectively) or any individual component of this. These results were unchanged after propensity score matched analysis. Conclusions: A 1-month duration of DAPT, for which 99.7% of patients were treated with a DCB strategy, appears safe and effective when compared with a 12-month duration of DAPT with no difference in major bleeding or MACE.

5.
Eur Radiol Exp ; 8(1): 77, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38992116

RESUMEN

BACKGROUND: Cardiac magnetic resonance (CMR) in the four-chamber plane offers comprehensive insight into the volumetrics of the heart. We aimed to develop an artificial intelligence (AI) model of time-resolved segmentation using the four-chamber cine. METHODS: A fully automated deep learning algorithm was trained using retrospective multicentre and multivendor data of 814 subjects. Validation, reproducibility, and mortality prediction were evaluated on an independent cohort of 101 subjects. RESULTS: The mean age of the validation cohort was 54 years, and 66 (65%) were males. Left and right heart parameters demonstrated strong correlations between automated and manual analysis, with a ρ of 0.91-0.98 and 0.89-0.98, respectively, with minimal bias. All AI four-chamber volumetrics in repeatability analysis demonstrated high correlation (ρ = 0.99-1.00) and no bias. Automated four-chamber analysis underestimated both left ventricular (LV) and right ventricular (RV) volumes compared to ground-truth short-axis cine analysis. Two correction factors for LV and RV four-chamber analysis were proposed based on systematic bias. After applying the correction factors, a strong correlation and minimal bias for LV volumetrics were observed. During a mean follow-up period of 6.75 years, 16 patients died. On stepwise multivariable analysis, left atrial ejection fraction demonstrated an independent association with death in both manual (hazard ratio (HR) = 0.96, p = 0.003) and AI analyses (HR = 0.96, p < 0.001). CONCLUSION: Fully automated four-chamber CMR is feasible, reproducible, and has the same real-world prognostic value as manual analysis. LV volumes by four-chamber segmentation were comparable to short-axis volumetric assessment. TRIALS REGISTRATION: ClinicalTrials.gov: NCT05114785. RELEVANCE STATEMENT: Integrating fully automated AI in CMR promises to revolutionise clinical cardiac assessment, offering efficient, accurate, and prognostically valuable insights for improved patient care and outcomes. KEY POINTS: • Four-chamber cine sequences remain one of the most informative acquisitions in CMR examination. • This deep learning-based, time-resolved, fully automated four-chamber volumetric, functional, and deformation analysis solution. • LV and RV were underestimated by four-chamber analysis compared to ground truth short-axis segmentation. • Correction bias for both LV and RV volumes by four-chamber segmentation, minimises the systematic bias.


Asunto(s)
Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Inteligencia Artificial , Reproducibilidad de los Resultados , Corazón/diagnóstico por imagen , Aprendizaje Profundo
7.
Eur Heart J Cardiovasc Imaging ; 25(8): 1051-1058, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38925103

RESUMEN

AIMS: With an ageing population, the presence of asymptomatic valvular heart disease (VHD) in the community remains unknown. The aim of this study is to determine the prevalence and associated factors of asymptomatic VHD in individuals ≥60 years old and to evaluate the feasibility of echocardiographic screening for VHD in this population. METHODS AND RESULTS: This was a prospective cohort study conducted between 2007 and 2016 in the UK. Asymptomatic patients with no prior indication for echocardiography were invited to participate and evaluated with a health questionnaire, clinical examination, and transthoracic echocardiography. A total of 10,000 individuals were invited through their general practices. A total of 5429 volunteered to participate, of whom 4237 were eligible for inclusion. VHD was diagnosed in more than a quarter of patients (28.2%). The most common types of VHD were regurgitation of the tricuspid (13.8%), mitral (12.8%), and aortic (8.3%) valves (trivial regurgitation was not included). The rate of prevalence of clinically significant VHD was 2.4% (2.2% moderate and 0.2% severe), with mitral and aortic regurgitation being the most common. The only parameter associated with significant VHD was age (odds ratio 1.07 per 1 year increment, 95% confidence interval 1.05-1.09, P < 0.001). The number needed to scan to diagnose one clinically significant case of VHD is 42 for individuals ≥60 and 15 for those ≥75 years old. CONCLUSION: Asymptomatic VHD is present in a significant proportion of otherwise healthy individuals without known VHD over 60 years old. Age is strongly associated with an increased incidence of significant VHD.


Asunto(s)
Enfermedades Asintomáticas , Ecocardiografía , Enfermedades de las Válvulas Cardíacas , Humanos , Femenino , Masculino , Anciano , Estudios Prospectivos , Prevalencia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/epidemiología , Persona de Mediana Edad , Enfermedades Asintomáticas/epidemiología , Reino Unido/epidemiología , Estudios de Cohortes , Anciano de 80 o más Años , Medición de Riesgo , Factores de Edad
8.
J Clin Med ; 13(11)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38893000

RESUMEN

Background: Competitive sports and high-level athletic training result in a constellation of changes in the myocardium that comprise the 'athlete's heart'. With the spread of the COVID-19 pandemic, there have been concerns whether elite athletes would be at higher risk of myocardial involvement after infection with the virus. This systematic review and meta-analysis evaluated the prevalence of abnormal cardiovascular magnetic resonance (CMR) findings in elite athletes recovered from COVID-19 infection. Methods: The PubMed, Cochrane and Web of Science databases were systematically search from inception to 15 November 2023. The primary endpoint was the prevalence of abnormal cardiovascular magnetic resonance findings, including the pathological presence of late gadolinium enhancement (LGE), abnormal T1 and T2 values and pericardial enhancement, in athletes who had recovered from COVID-19 infection. Results: Out of 3890 records, 18 studies with a total of 4446 athletes were included in the meta-analysis. The pooled prevalence of pathological LGE in athletes recovered from COVID-19 was 2.0% (95% CI 0.9% to 4.4%, I2 90%). The prevalence of elevated T1 and T2 values was 1.2% (95% CI 0.4% to 3.6%, I2 87%) and 1.2% (95% CI 0.4% to 3.7%, I2 89%), respectively, and the pooled prevalence of pericardial involvement post COVID-19 infection was 1.1% (95% CI 0.5% to 2.5%, I2 85%). The prevalence of all abnormal CMR findings was much higher among those who had a clinical indication of CMR. Conclusions: Among athletes who have recently recovered from COVID-19 infection, there is a low prevalence of abnormal CMR findings. However, the prevalence is much higher among athletes with symptoms and/or abnormal initial cardiac screening. Further studies and longer follow up are needed to evaluate the clinical relevance of these findings and to ascertain if they are associated with adverse events.

9.
Eur Heart J Open ; 4(3): oeae038, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38751456

RESUMEN

Aims: Heart failure (HF) with preserved ejection fraction disproportionately affects women. There are no validated sex-specific tools for HF diagnosis despite widely reported differences in cardiac structure. This study investigates whether sex, as assigned at birth, influences cardiac magnetic resonance (CMR) assessment of left ventricular filling pressure (LVFP), a hallmark of HF agnostic to ejection fraction. Methods and results: A derivation cohort of patients with suspected pulmonary hypertension and HF from the Sheffield centre underwent invasive right heart catheterization and CMR within 24 h of each other. A sex-specific CMR model to estimate LVFP, measured as pulmonary capillary wedge pressure (PCWP), was developed using multivariable regression. A validation cohort of patients with confirmed HF from the Leeds centre was used to evaluate for the primary endpoints of HF hospitalization and major adverse cardiovascular events (MACEs). Comparison between generic and sex-specific CMR-derived PCWP was undertaken. A total of 835 (60% female) and 454 (36% female) patients were recruited into the derivation and validation cohorts respectively. A sex-specific model incorporating left atrial volume and left ventricular mass was created. The generic CMR PCWP showed significant differences between males and females (14.7 ± 4 vs. 13 ± 3.0 mmHg, P > 0.001), not present with the sex-specific CMR PCWP (14.1 ± 3 vs. 13.8 mmHg, P = 0.3). The sex-specific, but not the generic, CMR PCWP was associated with HF hospitalization (hazard ratio 3.9, P = 0.0002) and MACE (hazard ratio 2.5, P = 0.001) over a mean follow-up period of 2.4 ± 1.2 years. Conclusion: Accounting for sex improves precision and prognostic performance of CMR biomarkers for HF.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38657744

RESUMEN

Patients with cancer have elevated cardiovascular risks compared to those without cancer. As cancer incidence increases and cancer-related mortality decreases, cardiovascular diseases in patients with a history of cancer will become increasingly important. This in turn is reflected by the exponentially increasing amount of cardio-oncology research in recent years. This narrative review aims to summarize the key existing literature in several main areas of cardio-oncology, including the epidemiology, natural history, prevention, management, and determinants of the cardiovascular health of patients with cancer, and identify relevant gaps in evidence for further research.

11.
Open Heart ; 11(1)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38458769

RESUMEN

PURPOSE: The main objective of this study was to develop two-dimensional (2D) phase contrast (PC) methods to quantify the helicity and vorticity of blood flow in the aortic root. METHODS: This proof-of-concept study used four-dimensional (4D) flow cardiovascular MR (4D flow CMR) data of five healthy controls, five patients with heart failure with preserved ejection fraction and five patients with aortic stenosis (AS). A PC through-plane generated by 4D flow data was treated as a 2D PC plane and compared with the original 4D flow. Visual assessment of flow vectors was used to assess helicity and vorticity. We quantified flow displacement (FD), systolic flow reversal ratio (sFRR) and rotational angle (RA) using 2D PC. RESULTS: For visual vortex flow presence near the inner curvature of the ascending aortic root on 4D flow CMR, sFRR demonstrated an area under the curve (AUC) of 0.955, p<0.001. A threshold of >8% for sFRR had a sensitivity of 82% and specificity of 100% for visual vortex presence. In addition, the average late systolic FD, a marker of flow eccentricity, also demonstrated an AUC of 0.909, p<0.001 for visual vortex flow. Manual systolic rotational flow angle change (ΔsRA) demonstrated excellent association with semiautomated ΔsRA (r=0.99, 95% CI 0.9907 to 0.999, p<0.001). In reproducibility testing, average systolic FD (FDsavg) showed a minimal bias at 1.28% with a high intraclass correlation coefficient (ICC=0.92). Similarly, sFRR had a minimal bias of 1.14% with an ICC of 0.96. ΔsRA demonstrated an acceptable bias of 5.72°-and an ICC of 0.99. CONCLUSION: 2D PC flow imaging can possibly quantify blood flow helicity (ΔRA) and vorticity (FRR). These imaging biomarkers of flow helicity and vorticity demonstrate high reproducibility for clinical adoption. TRIALS REGISTRATION NUMBER: NCT05114785.


Asunto(s)
Estenosis de la Válvula Aórtica , Imagen por Resonancia Magnética , Humanos , Corazón , Hemodinámica , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Prueba de Estudio Conceptual
12.
Eur J Prev Cardiol ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38381595

RESUMEN

BACKGROUND: Long COVID syndrome has had a major impact on million patients' lives worldwide. The cardiovascular system is an important aspect of this multifaceted disease that may manifest in many ways. We have hereby performed a narrative review in order to identify the extent of the cardiovascular manifestations of the Long COVID syndrome. METHODS AND RESULTS: An in-depth systematic search of the literature has been conducted for this narrative review. The systematic search of PubMed and Cochrane databases yielded 3,993, of which 629 underwent full text screening. A total of 78 studies were included in the final qualitative synthesis and data evaluation. The pathophysiology of the cardiovascular sequelae of Long COVID syndrome and the cardiac manifestations and complications of Long COVID syndrome are critically evaluated. In addition, potential cardiovascular risk factors are assessed, and preventive methods and treatment options are examined in this review. CONCLUSIONS: This systematic review poignantly summarises the evidence from the available literature regarding the cardiovascular manifestations of Long COVID syndrome and reviews potential mechanistic pathways, diagnostic approaches, preventive measures and treatment options.

13.
Diagnostics (Basel) ; 14(3)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38337816

RESUMEN

Introduction: Cardiac resynchronisation therapy is ineffective in 30-40% of patients with heart failure with reduced ejection fraction. Targeting non-scarred myocardium by selecting the site of latest mechanical activation using echocardiography has been suggested to improve outcomes but at the cost of increased resource utilisation. The interval between the beginning of the QRS complex and the local LV lead electrogram (QLV) might represent an alternative electrical marker. Aims: To determine whether the site of latest myocardial electrical and mechanical activation are concordant. Methods: This was a single-centre, prospective pilot study, enrolling patients between March 2019 and June 2021. Patients underwent speckle-tracking echocardiography (STE) prior to CRT implantation. Intra-procedural QLV measurement and R-wave amplitude were performed in a blinded fashion at all accessible coronary sinus branches. Pearson's correlation coefficient and Cohen's Kappa coefficient were utilised for the comparison of electrical and echocardiographic parameters. Results: A total of 20 subjects had complete data sets. In 15, there was a concordance at the optimal site between the electrically targeted region and the mechanically targeted region; in four, the regions were adjacent (within one segment). There was discordance (≥2 segments away) in only one case between the two methods of targeting. There was a statistically significant increase in procedure time and fluoroscopy duration using the intraprocedural QLV strategy. There was no statistical correlation between the quantitative electrical and echocardiographic data. Conclusions: A QLV-guided approach to targeting LV lead placement appears to be a potential alternative to the established echocardiographic-guided technique. However, it is associated with prolonged fluoroscopy and overall procedure time.

16.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38276656

RESUMEN

BACKGROUND: Recent data have suggested that global longitudinal strain (GLS) could be useful for risk stratification of patients with severe aortic stenosis (AS). In this study, we aimed to investigate the prognostic role of GLS in patients with AS and also its incremental value in relation to left ventricular ejection fraction (LVEF) and late gadolinium enhancement (LGE). METHODS: We analysed all consecutive patients with AS and LGE-CMR in our institution. Survival data were obtained from office of national statistics, a national body where all deaths in England are registered by law. Death certificates were obtained from the general register office. RESULTS: Some 194 consecutive patients with aortic stenosis were investigated with CMR at baseline and followed up for 7.3 ± 4 years. On multivariate Cox regression analysis, only increasing age remained significant for both all-cause and cardiac mortality, while LGE (any pattern) retained significance for all-cause mortality and had a trend to significance for cardiac mortality. Kaplan-Meier survival analysis demonstrated that patients in the best and middle GLS tertiles had significantly better mortality compared to patients in the worst GLS tertiles. Importantly though, sequential Cox proportional-hazard analysis demonstrated that GLS did not have significant incremental prognostic value for all-cause mortality or cardiac mortality in addition to LVEF and LGE. CONCLUSIONS: Our study has demonstrated that age and LGE but not GLS are significant poor prognostic indicators in patients with moderate and severe AS.

17.
PLoS One ; 18(12): e0294746, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38096193

RESUMEN

AIM: Inflammation plays a central role in the pathogenesis of atherosclerosis and in the sequelae of percutaneous coronary intervention (PCI). Previous work demonstrated that intermediate monocytes (CD14++CD16+) are associated with adverse cardiovascular events, yet monocyte subset response following elective PCI has not been described. This article explores the changes in monocyte subset and humoral response after elective PCI. METHODS: This prospective study included 30 patients without inflammatory diseases being referred for elective PCI. We included patients treated with drug coated balloons or 2nd generation drug eluting stents. Patients underwent blood tests at baseline (prior to PCI), four hours, two weeks and two months later. Analyses were performed in terms of monocyte subsets (classical CD14++CD16-, intermediate CD14++CD16+ and non-classical CD14+CD16++), gene expression of CD14+ leucocytes and humoral biomarkers. RESULTS: Intermediate monocytes decreased significantly four hours after PCI, were recovered at two weeks, and increased significantly at two months post elective, uncomplicated PCI. They remain significantly elevated in the DES group but not in the DCB group. Gene expression analysis of CD14+ leucocytes showed IL18 had decreased expression at two weeks, CXCR4 and IL1ß decreased at two months, while pentraxin 3 increased at two weeks and two months. In terms of humoral biomarkers, hsTnI remains elevated up to two weeks post PCI while IL6 and TNFα remain elevated till two months post PCI. CONCLUSION: Intermediate monocytes increase significantly two months following elective, uncomplicated PCI. They remain significantly elevated in the DES group but not in the DCB group suggesting that the PCI strategy could be one of the ways to modulate the inflammatory response post PCI.


Asunto(s)
Monocitos , Intervención Coronaria Percutánea , Humanos , Monocitos/metabolismo , Estudios Prospectivos , Intervención Coronaria Percutánea/efectos adversos , Receptores de Lipopolisacáridos/metabolismo , Biomarcadores/metabolismo , Inflamación/metabolismo , Receptores de IgG/metabolismo , Proteínas Ligadas a GPI/metabolismo
18.
Open Heart ; 10(2)2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38114194

RESUMEN

AIMS: Blood pressure (BP) is a crucial factor in cardiovascular health and can affect cardiac imaging assessments. However, standard outpatient cardiovascular MR (CMR) imaging procedures do not typically include BP measurements prior to image acquisition. This study proposes that brachial systolic BP (SBP) and diastolic BP (DBP) can be modelled using patient characteristics and CMR data. METHODS: In this multicentre study, 57 patients from the PREFER-CMR registry and 163 patients from other registries were used as the derivation cohort. All subjects had their brachial SBP and DBP measured using a sphygmomanometer. Multivariate linear regression analysis was applied to predict brachial BP. The model was subsequently validated in a cohort of 169 healthy individuals. RESULTS: Age and left ventricular ejection fraction were associated with SBP. Aortic forward flow, body surface area and left ventricular mass index were associated with DBP. When applied to the validation cohort, the correlation coefficient between CMR-derived SBP and brachial SBP was (r=0.16, 95% CI 0.011 to 0.305, p=0.03), and CMR-derived DBP and brachial DBP was (r=0.27, 95% CI 0.122 to 0.403, p=0.0004). The area under the curve (AUC) for CMR-derived SBP to predict SBP>120 mmHg was 0.59, p=0.038. Moreover, CMR-derived DBP to predict DBP>80 mmHg had an AUC of 0.64, p=0.002. CONCLUSION: CMR-derived SBP and DBP models can estimate brachial SBP and DBP. Such models may allow efficient prospective collection, as well as retrospective estimation of BP, which should be incorporated into assessments due to its critical effect on load-dependent parameters.


Asunto(s)
Función Ventricular Izquierda , Humanos , Presión Sanguínea/fisiología , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico
19.
J Innov Card Rhythm Manag ; 14(10): 5605-5609, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37927396

RESUMEN

Elevated right ventricular pacing (RVP) burdens are associated with the development of pacing-induced cardiomyopathy. This association is alluded to in the recent European and American pacing guidelines where anticipated pacing burden forms part of the indications for conduction system pacing. Understanding the temporal pattern of RVP burden is important with respect to anticipating future burden and ensuring that the most appropriate pacing modality is selected for patients. To the best of our knowledge, this is the first study to assess how RVP burden changes over time in different pacing indications. A retrospective, single-center, observational study was performed. RVP burdens from pacing checks were extracted and plotted against 6-month time "bins." Graphical plots of RVP burdens for different pacing indications were produced. There was no significant change in the RVP burden across time, independent of the initial pacing indication. Individuals with sinus node disease (SND) and a P-R interval of >250 ms had increased RVP burden. Other than patients with SND and a P-R interval of <250 ms, individuals had pacing burdens higher than those proposed in both the European and American pacing guidelines for conduction system pacing.

20.
J Am Coll Cardiol ; 82(8): 721-734, 2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37587584

RESUMEN

Valvular heart disease (VHD) is common and poses important challenges from the standpoints of diagnosis and therapeutic management. Clinical practice guidelines have been developed to help health care professionals to overcome these challenges and provide optimal management to patients with VHD. The American College of Cardiology, in collaboration with the American Heart Association, and the European Society of Cardiology, in collaboration with the European Association for Cardio-Thoracic Surgery, recently updated their guidelines on the management of VHD. Although these 2 sets of guidelines are generally concordant, there are some substantial differences between these guidelines, which may have significant implications for clinical practice. This review prepared on behalf of the EuroValve Consortium describes the consistencies and discrepancies between the guidelines and highlights the gaps in these guidelines and the future research perspectives to fill these gaps.


Asunto(s)
Cardiología , Enfermedades de las Válvulas Cardíacas , Estados Unidos , Humanos , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/terapia , Corazón , American Heart Association , Personal de Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...