Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Blood Purif ; 41(1-3): 177-87, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26765143

RESUMEN

When kidney failure occurs, patients are at risk for fluid overload states, which can cause pulmonary edema, pleural effusions, and upper airway obstruction. Kidney disease is also associated with impaired respiratory function, as in central sleep apnea or chronic obstructive pulmonary disease. Hence, respiratory and renal diseases are frequently coexisting. Hypoxemia is the terminal pathway of a multitude of respiratory pathologies. The measurement of oxygen saturation (SO2) is a basic and commonly used tool in clinical practice. Both arterial oxygen saturation (SaO2) and central venous oxygen saturation (ScvO2) can be easily obtained in hemodialysis (HD) patients, SaO2 from an arteriovenous access and ScvO2 from a central catheter. Here, we give a brief overview of the anatomy and physiology of the respiratory system, and the different technologies that are currently available to measure oxygen status in dialysis patients. We then focus on literature regarding intradialytic SaO2 and ScvO2. Lastly, we present clinical vignettes of intradialytic drops in SaO2 and ScvO2 in association with different symptoms and clinical scenarios with an emphasis on the pathophysiology of these cases. Given the fact that in the general population hypoxemia is associated with adverse outcomes, including increased mortality, cardiac arrhythmias and cardiovascular events, we posit that intradialytic SO2 may serve as a potential marker to identify HD patients at increased risk for morbidity and mortality.


Asunto(s)
Síndrome Cardiorrenal/terapia , Hipoxia/fisiopatología , Fallo Renal Crónico/terapia , Oxígeno/sangre , Insuficiencia Renal Crónica/terapia , Biomarcadores/sangre , Síndrome Cardiorrenal/sangre , Síndrome Cardiorrenal/mortalidad , Síndrome Cardiorrenal/fisiopatología , Cateterismo Venoso Central , Fluidoterapia/efectos adversos , Humanos , Hipoxia/sangre , Hipoxia/etiología , Hipoxia/mortalidad , Fallo Renal Crónico/sangre , Fallo Renal Crónico/mortalidad , Fallo Renal Crónico/fisiopatología , Diálisis Renal/efectos adversos , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/mortalidad , Insuficiencia Renal Crónica/fisiopatología , Factores de Riesgo , Análisis de Supervivencia
2.
Gastrointest Endosc ; 63(7): 1055-8, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16733125

RESUMEN

BACKGROUND: Localization of the proximal jejunum is important for creation of gastrojejunal anastomosis to palliate gastric outlet obstruction or for treatment of obesity with gastric bypass. OBJECTIVE: To facilitate identification of the proximal jejunum during transgastric endoscopic gastrojejunostomy with the use of an endoscopic transilluminator (ET). DESIGN AND SETTING: Acute experiments in a live porcine model. INTERVENTIONS: The ET is a 3500-mm long, 6F radio-opaque tube with a fiberoptic core that lights up at its distal end. When situated in the intestinal lumen, it transilluminates the bowel wall. With the animal under general anesthesia with endotracheal intubation, a colonoscope was advanced to the proximal jejunum. A plastic tube (3500-mm long, 3.5 mm in diameter) was passed through the biopsy channel and placed into the small bowel. The colonoscope was withdrawn, leaving the tube in place. The ET was introduced into the jejunum through the tube. A gastric wall incision was made and the endoscope was advanced to the peritoneal cavity. The transilluminated loop of the proximal jejunum was identified and gastrojejunal anastomosis was made by use of a previously reported endoscopic technique. MAIN OUTCOME MEASUREMENTS: Identification of the proximal jejunum. RESULTS: Eleven pigs (average weight 55 kg) had ET placement. In all of the pigs, placement of the ET was performed easily to the proximal small bowel, and the proximal jejunum was successfully localized by either direct visualization of the transilluminated loop only or with the aid of fluoroscopy. The tip of the ET was usually located about 50 to 70 cm distal to the ligament of Treitz. There were no complications related to the use of ET. LIMITATIONS: The device has not yet been evaluated in humans. CONCLUSIONS: The ET is a safe instrument and can be used to identify the proximal jejunum to facilitate endoscopic gastrojejunostomy.


Asunto(s)
Endoscopios Gastrointestinales , Gastrostomía/instrumentación , Yeyunostomía/instrumentación , Transiluminación/instrumentación , Animales , Endoscopía Gastrointestinal , Diseño de Equipo , Laparoscopía , Porcinos
3.
Gastrointest Endosc ; 62(2): 287-92, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16046997

RESUMEN

BACKGROUND: We have previously reported the feasibility and the safety of an endoscopic transgastric approach to the peritoneal cavity in a porcine model. We now report successful performance of endoscopic gastrojejunostomy with survival. METHODS: All procedures were performed on 50-kg pigs, with the pigs under general anesthesia, in aseptic conditions with sterilized endoscopes and accessories. The stomach was irrigated with antibiotic solution, and a gastric incision was performed with a needle-knife and a sphincterotome. A standard upper endoscope was advanced through a sterile overtube into the peritoneal cavity. A loop of jejunum was identified, was retracted into the stomach, and was secured with sutures while using a prototype endoscopic suturing device. An incision was made into the jejunal loop with a needle-knife, and the filet-opened ends of the jejunal wall were secured to the gastric wall with a second line of sutures, completing the gastrojejunostomy. OBSERVATIONS: Two pigs survived for 2 weeks. Endoscopy and a radiographic contrast study performed after gastrojejunostomy revealed a patent anastomosis with normal-appearing gastric and jejunal mucosa. Postmortem examination demonstrated a well-healed anastomosis without infection or adhesions. CONCLUSIONS: The endoscopic transgastric approach to create a gastrojejunostomy is technically feasible and can be performed, with survival, in a porcine model.


Asunto(s)
Endoscopía Gastrointestinal/métodos , Gastrostomía/métodos , Yeyunostomía/métodos , Animales , Modelos Animales de Enfermedad , Estudios de Factibilidad , Gastrostomía/mortalidad , Yeyunostomía/mortalidad , Seguridad , Porcinos
4.
Gastrointest Endosc ; 61(3): 449-53, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15758923

RESUMEN

BACKGROUND: We have previously reported the feasibility and safety of the peroral transgastric endoscopic approach for diagnostic peritoneoscopy, liver biopsy, and gastrojejunostomy with long-term survival in a porcine model. This approach eliminates incisions of the abdominal wall, providing a less invasive alternative to diagnostic and therapeutic laparoscopy. We now report successful performance of peroral endoscopic transgastric ligation of Fallopian tubes with long-term survival in a porcine model. METHODS: Six female 50-kg pigs had general anesthesia and irrigation of the stomach with an antibiotic solution. Gastric puncture was performed with needleknife electrocautery followed by balloon dilatation of the tract with 20-mm TTS dilating balloon (Microvasive). A standard upper endoscope that underwent high-level disinfection and gas sterilzation was advanced into the peritoneal cavity through a sterile overtube. Both Fallopian tubes were identified and one was ligated using Olympus Endoloops. The other patent tube served as a control. Tubal patency was evaluated by hysterosalpingogram before and after ligation. After a follow-up period of 2-3 weeks, the pigs were sacrificed for postmortem examination. RESULTS: The Fallopian tubes were easily accessed, identified and ligated in all 6 pigs. In each pig, fluoroscopy confirmed complete obstruction of the ligated tube with preserved patency of the other tube. All pigs survived well and ate heartily without any ill-effects. Postmortem examination did not reveal any peritonitis or intra-abdominal adhesions. The Endoloops were in place with complete obstruction of the ligated tubes and patency of the controls. Histopathologic examination of the tubes showed chronic inflammatory infiltrates without abscesses. CONCLUSIONS: The peroral endoscopic transgastric approach to ligation of the Fallopian tubes with long-term survival is technically feasible and safe in a porcine model. The endoscopic transgastric approach to the peritoneal cavity has potential for a wide array of diagnostic and therapeutic procedures.


Asunto(s)
Endoscopía/métodos , Trompas Uterinas , Animales , Femenino , Ligadura/métodos , Tasa de Supervivencia , Porcinos , Factores de Tiempo
5.
Gastrointest Endosc ; 60(1): 114-7, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15229442

RESUMEN

BACKGROUND: A novel endoscopic peroral transgastric approach to the peritoneal cavity was tested in a porcine model in acute and long-term survival experiments. METHODS: Transgastric peritoneoscopy was evaluated in 50-kg pigs. After upper endoscopy, the peritoneal cavity was accessed by needle-knife puncture of the gastric wall, followed by extension of the incision either with a pull-type sphincterotome or by balloon dilation. The peritoneal cavity was examined, and a liver biopsy specimen was obtained. The gastric wall incision was closed with clips. OBSERVATIONS: Twelve acute and 5 survival experiments were performed. Both techniques of gastric wall incision were without complication. The acute experiments demonstrated the technical feasibility of the approach. In the survival experiments, all pigs recovered and gained weight. CONCLUSIONS: The peroral transgastric approach to peritoneal cavity technically is feasible and has the potential to be an alternative to laparoscopy and laparotomy.


Asunto(s)
Laparoscopía/métodos , Animales , Cateterismo , Estudios de Factibilidad , Sus scrofa , Porcinos
6.
Gastrointest Endosc ; 57(3): 403-6, 2003 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12612530

RESUMEN

BACKGROUND: Thermal therapy is the cornerstone of endoscopic treatment of bleeding mucosal lesions of the GI tract. However, there is a 20% failure rate and contact devices may be cumbersome in the treatment of large bleeding areas. A pilot study was conducted to evaluate the safety and efficacy of endoscopic cryotherapy for bleeding mucosal vascular lesions. METHODS: Patients with recurrent bleeding from diffuse mucosal vascular lesions were treated with cryotherapy and had endoscopic and clinical follow-up. RESULTS: Twenty-six patients with gastric and duodenal arteriovenous malformations (n = 7), watermelon stomach (n = 7), radiation-induced gastritis (n = 5), and radiation-induced proctitis (n = 7) were treated with mean of 3.4 (1.6) sessions. The best results were achieved in patients with radiation-induced proctitis, with cessation of bleeding in all 7 patients. Cryotherapy was also effective in patients with multiple arteriovenous malformations (86%) and watermelon stomach (71%). It was less effective in patients with radiation-induced damage to stomach and duodenum, although all patients in this group were debilitated because of disseminated malignancy. CONCLUSIONS: Cryotherapy is a safe and effective treatment for bleeding from diffuse mucosal lesions of the GI tract. Bleeding from radiation-induced proctitis and multiple arteriovenous malformations is particularly responsive to endoscopic cryotherapy.


Asunto(s)
Crioterapia , Hemorragia Gastrointestinal/terapia , Hemostasis Endoscópica , Anciano , Malformaciones Arteriovenosas/complicaciones , Malformaciones Arteriovenosas/terapia , Femenino , Ectasia Vascular Antral Gástrica/complicaciones , Ectasia Vascular Antral Gástrica/terapia , Gastritis/complicaciones , Gastritis/terapia , Hemorragia Gastrointestinal/etiología , Humanos , Masculino , Proyectos Piloto , Proctitis/complicaciones , Proctitis/terapia , Traumatismos por Radiación/complicaciones , Traumatismos por Radiación/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...